Tender For Extension Modification Of Existing 440 V Ohl From Qry 1 Extension To Qry 1 Mines For Providing Proper Lighting In Haul Road New Pumping Site And In Mines Rocp
Tender Overview
Project Description
Extension Modification Of Existing 440 V Ohl From Qry 1 Extension To Qry 1 Mines For Providing Proper Lighting In Haul Road New Pumping Site And In Mines Rocp Extension Modification Of Existing 440 V Ohl From Qry 1 Extension To Qry 1 Mines For Providing Proper Lighting In Haul Road New Pumping Site And In Mines Of Rajhara Ocp Under Rajhara Area
BOQ
| Sl. No. | Item Description |
| 1 | Erection of metallic pole of above 10 mtr. And upto 12 mtr. In cement concrete 1:3:6 (1 cement:3 corse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required |
| 2 | Erection of metallic pole of above 8 mtr. And upto 10 mtr. In cement concrete 1:3:6 (1 cement:3 corse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required |
| 3 | Supplying and erction of stay set complete (galvanised) with 19/20 mm dia x 1.8 mtr. Long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm , thimble , stay clamps , turn buckle (20 mm x 60 cm), 7/4.00 mm dia G.I. stay wire and strain insulator etc. in cement concrete1:3:6 (1 cement:3 corse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and also with 0.6 mtr. long brace of size 50 mm x 50 mm x 6 mm angle iron with 50 mm dia pulley fixed at one end of the braceas required |
| 4 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg permetre) cross arm for 4 wire over head line complete with clamps,bolts, nuts and washer etc including drilling of holes for insulatorpins etc (as per drawing) and painting with primer and finishedpaint as required . |
| 5 | Erection of angle iron/channel iron cross arm on wood/RCC/PCC/ steel tubular/ rail pole etc. as required. |
| 6 | Supplying and erection of galvanised D iron clamps complete with shackle insulator (100 mm x 110 mm) , GI bolts , nuts and washers , coach screw etc. as required |
| 7 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 8 | Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required. |
| 9 | Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required. |
| 10 | Supplying and erection of 100 mm x 80 mm pin insulator with GI bolt , nuts and straps etc. as required |
| 11 | Erection of ACSR conductorof 7/1.96mm to 7/3.10 mm dia and includingbinding etc. as required |
| 12 | Coolie ( for transporting of poles, conductor, iron material etc. from store/outside to mines) |
| 13 | 8 SWG GI wire |
| 14 | Erection of GI wire no. 8 SWG including binding etc. as required |
| 15 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 16 | Providing and fixing 4.00mmdiacopperwireonsurfaceor in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 17 | Supplying and fixing MV horn gap lightening arrestor as required. |
| 18 | 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 19 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminium paint of approved brand and manufacture over a priming coat of ready mixed zinc chromate yellow primer on new work : 150 mm diameter pipes |
| 20 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminium paint of approved brand and manufacture over a priming coat of ready mixed zinc chromate yellow primer on new work : 100 mm diameter pipes |
| 21 | Total impact of GST for the purpose of CTC |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender