Tender For Supply Of Nucleonic Level Instruments For Msb Unit As Per Technical Specifications For Numaligarh Refinery Limited
Tender Overview
Project Description
Supply Of Nucleonic Level Instruments For Msb Unit As Per Technical Specifications For Numaligarh Refinery Limited Supply Of Nucleonic Level Instruments For Msb Unit As Per Technical Specifications For Numaligarh Refinery Limited , Supply Of Nucleonic Level Instruments For Nrep Project Design, Detail Engineering, Procurement, Manufacturing, Assembly, Testing & Inspection At Manufacturer’S Works, Packing, Forwarding, Transportation, Route Survey ( If Required ) , And Supply Till Site Including Commissioning Spares, Special Tools & Tackles, Consumables & Third Part Inspection Charges For Following Nuclear Level Detector / Transmitter For Msb Unit As Specified In Material Requisition. , Supply Of Nucleonic Level Instruments For Nrep Project • 1P23- Lt -632101 Nuclear Level Detector / Transmitter • 1P23- Lt -632102 Nuclear Level Detector / Transmitter • 1P23- Lt -273901 Nuclear Level Detector / Transmitter • 1P23- Lsll -273902 Nuclear Level Switch • 1P23- Lsll -273801 Nuclear Level Switch • 1P23- Lt -273802 Nuclear Level Detector / Transmitter • 1P23- Lsll -274001 Nuclear Level Switch • 1P23- Lt -274002 Nuclear Level Detector / Transmitter • 1P23- Lsh -823201 Nuclear Level Switch • 1P23- Lsl -823202 Nuclear Level Switch • 1P23- Lsll -083201 Nuclear Level Switch • 1P23- Lt -823101 Nuclear Level Detector / Transmitter • 1P23- Lsll -823301 Nuclear Level Switch • 1P23- Lt -823302 Nuclear Level Detector / Transmitter • 1P25 Lt -262613 Nuclear Level Detector / Transmitter Including - Personal Dose Rate Meter Cum Leakage Detector Fornucleonic Level Instruments - Total 03 Nos. ( 2 Nos ( For Ccr Unit ) + 1 Nos ( For Pfcc Unit ) ) , Charges For Site Supervision Of Erection / Installation And Testing For Nucleonic Level Transmitters For Nrep Project Same Rate Is Also Applicable For 2 Mandatory Visits During Maintenance Support / Supervisory Service During Warranty / Defect Liability Period , Per Diem Charges For Upto 8 Hours Work On Normal Working Days. , Overtime Rate / Hour Beyond Normal 8 Hours Work On Normal Working Days. , Overtime Rate / Hour For Work On Weekly Off Days / Holidays ( As Applicable To Refinery Site ) .
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Apr-2023 | Addendum_1_TechClar1 | Other | 25-May-2023 |
| 2 | 25-May-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-Jun-2023 |
| 3 | 02-Jun-2023 | Addendum_3_Nucleonic_Ext2 | Date | 12-Jun-2023 |
| 4 | 13-Jun-2023 | Addendum_4_Nucleonic_Ext3 | Date | 22-Jun-2023 |
| 5 | 23-Jun-2023 | Addendum_5_Nucleonic_Ext6 | Date | 29-Jun-2023 |
| 6 | 30-Jun-2023 | Addendum_6_Ext4 | Date | 10-Jul-2023 |
| 7 | 11-Jul-2023 | Addendum_7_Ext6 | Date | 19-Jul-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | SUPPLY OF NUCLEONIC LEVEL INSTRUMENTS FOR NREP PROJECTDesign, detail engineering, procurement, manufacturing, assembly, testing & inspection at manufacturer’s works, packing, forwarding, transportation, route survey (if required), and supply till site including Commissioning spares, Special Tools & Tackles, Consumables & Third Part Inspection Charges for following NUCLEAR LEVEL DETECTOR /TRANSMITTER for MSB Unit as specified in Material Requisition. |
| 2 | SUPPLY OF NUCLEONIC LEVEL INSTRUMENTS FOR NREP PROJECT• 1P23- LT -632101 Nuclear Level Detector / Transmitter• 1P23- LT -632102 Nuclear Level Detector / Transmitter • 1P23- LT -273901 Nuclear Level Detector / Transmitter• 1P23- LSLL -273902 Nuclear Level Switch • 1P23- LSLL -273801 Nuclear Level Switch • 1P23- LT -273802 Nuclear Level Detector / Transmitter• 1P23- LSLL -274001 Nuclear Level Switch • 1P23- LT -274002 Nuclear Level Detector / Transmitter • 1P23- LSH -823201 Nuclear Level Switch • 1P23- LSL -823202 Nuclear Level Switch • 1P23- LSLL -083201 Nuclear Level Switch • 1P23- LT -823101 Nuclear Level Detector / Transmitter • 1P23- LSLL -823301 Nuclear Level Switch • 1P23- LT -823302 Nuclear Level Detector / Transmitter • 1P25 LT -262613 Nuclear Level Detector / Transmitter Including - Personal Dose rate meter cum leakage detector forNUCLEONIC LEVEL INSTRUMENTS - Total 03 Nos. (2 nos (For CCR unit) + 1 nos (For PFCC unit)) |
| 3 | Charges for SITE Supervision of Erection / Installation and Testing for NUCLEONIC LEVEL TRANSMITTERS FOR NREP PROJECTSame rate is also applicable for 2 mandatory visits during MAINTENANCE SUPPORT/ SUPERVISORY SERVICE DURING WARRANTY/ DEFECT LIABILITY PERIOD |
| 4 | Per diem charges for upto 8 hours work on normal working days. |
| 5 | Overtime rate / hour beyond normal 8 hours work on normal working days. |
| 6 | Overtime rate / hour for work on weekly off days / holidays (as applicable to Refinery site). |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-7 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender