Tender For Repair Replacement Of Summer Cooling Appliances And Maintenance Of Ac Plant Alongwith Connected Items Under Ge Nagrota, Jammu-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair Replacement Of Summer Cooling Appliances And Maintenance Of Ac Plant Alongwith Connected Items Under Ge Nagrota. Submission Date for this Tender is 17-05-2023. Air Conditioner Tenders in Jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37315549
Corrigendum : Tender For Repair Replacement Of Summer Cooling Appliances And Maintenance Of Ac Plant Alongwith Connected Items Under Ge Nagrota
Open Tender
Indian
Jammu And Kashmir
Jammu
17-05-2023

Tender Details

Repair Replacement Of Summer Cooling Appliances And Maintenance Of Ac Plant Alongwith Connected Items Under Ge Nagrota

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-May-2023 REVISED BOQ BOQ 10-05-2023
2 10-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

REPAIR/REPLACEMENT OF AC PLANT WITH CONNECTED ITEMS AT GE NAGROTA
Sl. No. Item Description
1M&L forcleaning of shell and tube water cooled condensersof the A/C plants of followingcapacities afterdismantling the water lines and headers and cleaning with suitable wire brush and washing soda to remove the dirt andwater scaling and refixing the water lines and headers including provision of new gaskets, in every 04 moths etc complete all as directed byEngr-in-Charge.
252 TR capacity at Signal Center
352 TR capacity at OPS Room
415 TR capacity at 4 ASD
5Supply and charging compressor oil Servo manufacturedby Indian Oil Corporation or Equivalventapproved make including flushing/cleaning of oil chamber etc complete all asdirected by Engr-in-Charge.
6Nitrogen testingfor the ANY capacity of compressorsincluding condensing unit and gas piping completeas per the manufacturer instructiions and entire satisfaction of the Engineer in Charge.Note :- (i)Nitrozen pressure should be held with out any dropin pressure inside the unit continue for 24 hrs after leakage testiing reqired gas will be fill andsatisfaction of the Engineer in Charge.
7Supply and fillingNitrogen Gas Cyllinder of 61 Kg Each cyllinder complete
8Supply and fillingRefrigerant gas R-407 of 61 Kg Each Cyllinder for AC plant compressor
9Supply and fillingRefrigerant gas R-22 of 61 Kg Each Cyllinder for AC plant compressor
10M&L for servicing monoblock pumps including dismantling and openingthe pump, repair/replacement of defective Ball Bearing,Roller Bearing .impeller,replace the worn out bearing impeller,stuffing box, back plates, gland packing mechincal seal and rusted nut, bolts etcassembling property , greasing all movable parts, fixing in position, testing and commissioning all as directed for uo To 5HP pumps.
11Same as Ser No 7 but upto 7.5 to 10 HP
12Same as Ser No 7 but upto 10 to 15 HP
13Supply and fixing in repair power assembly expansion valve for up 52 TR AC palntat EHU / ERS Model SVE 42 Make –SPORLAN or equivalent as per the existing.
14Supply and fixing in repair MVPD for up to 52 TR TR capacity at OldAC plant Modelequivalent as per the existing.
15Suuply and fix ofV-beltsize C 2650/ C-102 including taking down old belt .
16All as per item No-11 as above but of size B-112 .
17All as per item No-11 as above but of size B- 82.
18Realignment of compressor and motor of anycapacity on existing foundation.
19Supply and fixing of CI butterfly valves with matching flanges,gaskets,hardware duly insulated with preformed pipe section fabricated to shape and bonded with adhesive. removable cover is required valves in 26swg aluminium sheet,cover should be divided in to portions quick release toggles shall be used for assembly of covers.
2050 mm bore.
2165mm bore.
22Supply and fixHigh pressure control switch type MP-5 including taking down old switch. AS per existing make
23Supply and fixoil pressure control switch type MP-55 including taking down old switch. AS per existing make
24Supply and fixlow pressure control switch type MP-01 including taking down old switch.AS per existing make
25Supply and fixLP/HP cut out type MP-15 inlcuding taking down old cutout.AS per existing make
26All as per item No - 18 but type ML-4Make –AS per existing make
27All as per item No - 18but type ML-3Make – AS per existing make
28All as per item No - 18but type ML-2Make –AS per existing make
29All as per item No - 18but type ML-1.5 Make –AS per existing make
30Supply and fixing power contract assemblycomplete MNX-25 as per cat No CS 94110 Make – L & T or equivalent makeincluding taking down old contactor
31Supply and fixing power contract assemblycomplete MNX-12with one NO and NCas per Exixting Make – L & T or equivalent make aas Schneiderincluding taking down old contactor
32Supply and fixing power contract assemblycomplete MNX 32 Make – AS per existing make including taking down old contactor
33Supply andfixing spare Kit wihtout coil type MU-1 including taking down old kit. Make – AS per existing make
34All as per item No - 26buttype ML-1.5 as per cat No SS91851 . Make – AS per existing make
35All as per item No - 26but type ML-2 as per AS per existing make .
36All as per item No - 26type ML-3 as perexisting make
37All as per item No - 26but type ML-4 as per existing make
38Supply andfixing Overvload relay range 9-15 amps . Make –AS per existing make suitable for ML-1/ML-1.5 contactor
39Supply andfixing Overvload relay range 20-33 amps . Make –AS per existing make suitable for ML-2/ML-3 contactor
40Supply andfixing Overvload relay range upto 7.5 amps. Make –AS per existing make suitable for MNX contactor
41Supply and fixing electronic timer ST 100 (3 to 10 Sec) 240V or as per existing .Make –AS per existing make including taking down of old one.
42Supply and fixing electronic timer ST 100 ST 100 (3 to 30 Sec) 415 Volts AC 50 HZ . Make- L Make –AS per existing makeas GIC suitable to the existing panel board inlcuding taking down of old one.
43Supply and fixing indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly Make – Mimic control/AEC/C&S.
44Supply and fixing in repair of MCCB3 pole415 volts AC , 250 Amps breaking capcity 25 KA, Make –L &T , or equivalent
45Supply and fixing in repair of MCCB3 pole415 volts AC , 40 Amps breaking capcity 25 KA, Make –L &T , or equivalent
46Supply and fixing in repair of MCCB3 pole415 volts AC , 32 Amps breaking capcity 25 KA, Make –L &T , or equivalent
47Dismantling the unserviceable electric motor any type or of any capacity and transporting to reputed workshop, taking out old and burnt winding wire and rewinding with super enameled copper winding wire of existing gauge andsize with insulating materials, varnishing andbaking etc,re-fixing the same at site andre-alignment,testing and commissioning complete all as directed by Engr-in-Charge
48Taking out old and unserviceable PVC fins of cooling tower of anycapacity AC plant and replacing with new one includingsetting complete .Make:Mihir or equivalent
49Supply and fix in repair in repair DOL starter suitable for 5HP motor capacity 9 to 14 Ampcomplete with over load relay , single phasing preventer under volt release etc .Make L&T or equivalent in Schneider / Havells.
50Supply and fix in repair in repair DOL starter suitable for 10 HP motor capacity 14 to 23 Ampcomplete with over load relay , single phasing preventer under volt release etc .Make L&Tor equivalent make as Schneider / Havells.
51Preparation of old painted surfaces by removing dust,rust etc and, applying two coats of synthetic enamel paint with spray gun of approved make and colour for cooling tower,condensing pipe line condenser water pumps including all pipe line valves etc. of 5 TR to 60 TR Capacity Plant.
52Supply and fix CT fan (with hub and fan blade) of capasity 5 to10 HPfor colling tower all as specified and directed by Engr-in-Charge
53S & F in repair chilled water sensor for AC Plants ofup to 52 TR capacity
54S & F solenoid valve assembly complete for compressor of capacity upto 15 TR.
55S & F solenoid valve assembly complete for compressor of capacity fromupto 52 TR.
56S & F loading/unloading switch assembly for compressor of capacity upto 15 TR.
57S & F loading/unloading switch assembly for compressor of capacity fromupto 52 TR.
58S & F microprocessor for compressor of capacity upto 15 TRof existing model
59S & F microprocessor for compressor of capacity from 52 TRof existing model
60S & F cooling tower nozzles 1/4"" size of existing model
61S & F block bearing for air handling unit existing sizeof existing model
62Dismantling the compresor and taking out the shaft from the compressing unit and taking to the reputed workshop for necessary lathe/ machining work to match the bearing size, cleaning inside the compresing unit and necessary overhauling complete as directed .Installation of compressor and connect with motor , alingmentand carrying out of testing to the entire satisfaction of Engr-in-charge for the following compressor model :-Note : defective Spares required to be replaced shall be measured and paid seperately under appropriatre items of this schedule.
633 X 7.5 TR capacity at 4ASD
64Supply in replacement for 3 X 7.5 TR capacity at 4ASD
65Main bearing ( U/S upto 0.5 mm) for both ends
66Connecting rod bearing
67C R bush
68pistons
69Pistons pin
70Piston ring set
71Piston circlips
72C R Nuts & bolts
73S V Reeds
74D V Reeds
75S VSprings
76D V Spring
77Suction filter drayer.
78Oil pump
79Linear o ring
80Gasket set
81Thurst washer
82Aluminium Gasket set
83Rocker arm with cup & washer
84Oil pressure regulating valve
85Rocker arm spring
86Suction and discharge valve O ring set
87S & F in repair water Flow Gauge Meter for AC Plants ofany capacity
88S & F in repair Oil Pressure Gauge Meter for AC Plants ofany capacity
89S & F in repairRefrigerant Gas Pressure Gauge Meter for AC Plants ofany capacity
90Supply and fixing in repairof 13 TRsemisealed/sealed compressor with modification to existing system including testing complete all as specified and directed by Engr-in Charge.Make Kirloskar, Brite,
91Repair and maintenance of Ac plant heater incliding internal wiring and replace of any part of internal body all as specified and as directed by Engr-in-charge.
92Material andLabour for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for the following capacity of water cooler / refrigerator :-
93Water coolers 40 to 150 ltrs cooling capacity.
94Refrigerator of 165 to 310 ltrs capacity.
95Deep Freezers any capacity
96Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge.
97Water coolers of capacity up to 150liters.
98Refrigerators of capacity 210 to 310 ltrs.
99Deep freezers 200 to 300 ltrs capacity.
100Supply and replace starting relay suitable for :- Make : as per exiting make
101Water coolers 40 to 150 ltrs cooling capacity
102Refrigerator of 165 to 310 liters capacity.
103Deep freezers of 200 to 425 ltrs capacity.
104Supply and replace thermostats of :-Make : as per exiting make
105Water coolers 40 to 150 ltrs cooling capacity.
106Refrigerator of 165 to 310 ltrs capacity.
107Deep freezers of 200 to 325 ltrs capacity.
108Supply andcharging refrigerant gas R-22/R-134 (A)up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas including leakage testing if any complete all as specified and directed by Engr-in-Charge
109Water cooler 40 ltr cooling cap.
110Water cooler 80 ltr cooling cap.
111Water cooler 150 ltrs cooling cap
112Deep freezers ofany capacity.
113Refrigerators of any capacity.
114Supply and replace condenser unit of the following appliances including making of all connections as specified and directed by Engr-in-Charge. Make : as per exiting make
115Water coolers 40/60 ltrs capacity.
116Refrigerator r of 165 to 195 ltrs capacity.
117Deep freezers of 200 to 300 ltrs capacity.
118Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity.
119Supply and replace overload protector of :-Make : as per exiting make
120Water coolers/ Refrigarator upto 150 ltrs cooling capacity.
121Deep freezers of upto 425 ltrs capacity.
122Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames for :-Make : as per exiting make
123Water coolers of any make and cap 40 to 150 ltrs capacity.
124Deep freezers of any make & cap 200 to 300 ltrs capacity.
125Supply andcharging refrigerant gas R-22/R-134 (A)up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas complete all as specified and directed by Engr-in-Charge. Make Paragon,Mefron(Note : Above secondfloor contractor willarrange crain / scaffolding with safety device)
126Window type room air conditioners of capacity 1.5 Ton.
127Split type AC 1.5/2.0 Ton capacity
128M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :-(Note : Above secondfloor contractor willarrange crain / scaffolding with safety device)
129Window type room air conditioners of capacity 1.5 Ton cap.
130Split type AC 1.5/2 Ton capacity.
131Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge.
132Window type air conditioners of capacity 1.5 /1 Ton.
133Split type AC 1.5/2.0 Ton capacity.
134Supply and replace capacitors of the following capacities for ACs Make :Siemens,epcos
1353.15 ,4 & 6 Mfd
13610 Mfd
13736 Mfd
13880/100 Mfd
139120 Mfd
14045+6 Mfd Seven Pin
141Supply and replace starting relay suitable for :-
142Window type room air conditioners of capacity 1/1.5 Ton cap.
143Split type AC 1.5/2 Ton capacity
144Supply and replace thermostats of :- Make Danfoss,Annapooma
145Window type room air conditioners of capacity 1/1.5 Ton cap.
146Split type AC 1.5/2 Ton capacity.
147Supply and replace oeverload protector of :- Make Usha,Annapooma
148Window type room air conditioners of capacity 1/1.5 Ton cap.
149Split type AC 1.5/2 Ton capacity.
150Supply and replace condenser unit make of copperof the following appliances including making of all connections as specified and directed by Engr-in-Charge
151Window type room air conditioners of capacity 1/1.5 Ton capacity.
152Split type AC 1.5/2 Ton capacity.
153Supply and replace metal clad/sheet metal plug and socket with a 2 pin and earth plug and 20 Amps SP MCB complete including making all connections. complete all as directed by Engr-in-Charge.
154Supply and replace contact unit of split type air conditioning of 1.5/2 Ton capcomplete all as directed by Engr-in-Charge.
155Supply and Install automatic copper wound voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay suitable for connection on single phase 50 HZ AC supply, designed for input voltage of 90 to 290 V and output voltage stablized at 215 to 240 V of Capacity 3 KVA complete with digital voltmeter and ammeter with time delay relay of 2-3 Minutecomplete all as specified and Directeby Engr incharge. Make: V-Guard/Microtech/Electric Field/AE
156Supply And Fix with repairof defective burnt motor from unitand testingall as directed for the following;-
157Window type AC of any make capacity 1/1.5 Ton cap.
158Split type AC of any make and capacity 1.5/2 ton.
159Supply and fix insulation for copper tubes of split type AC units,insulation type superion of sizen 3/8"diameter
160Supply and fix insulation for copper tubes of split type AC units,insulation type superion of sizen 5/8"diameter
161Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8" diameter
162Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8" diameter
163Supply and fix PCBcercuit board complte suitable for 1.5/2.0 ton capacitysplit type air conditioneer complete all as directed by Engr-in-Charge.
164Supply and fix PCBcercuit board complte suitable for 1.5/2.0 ton capacityWindow type AC complete all as directed by Engr-in-Charge.
165Supply and fix in repair Remote of any size and capacity of split AC . complete all as directed by Engr-in-Charge.
166Supply in replacement of indoor collingunit 1.5 Toncapacity copper tubing with rotary fan suitableof existing make with suitable remote complete all as directed by Engr-in-Charge.
167S&Fin replacement of desert cooler 1350 Rpm capacitymotorwith fan bladeof existing make withall arrangementcomplete all as directed.
168Replacement of water circulation submersible pump of desert coolersuitable for operation on AC supply single phase230/250 volts 50 Hz. complete all as directed by Engr-in-Charge.
169Taking out existing old wood wool pads from desert coolers and S&Fwood wool padswith nylon threads suitable for any make of desert cooler having minimum/maximum capacity 3000 cum/hr and 5000 cum hrs including S&F PVC insulated protective guards for holding the wood pads complete all as specified and as directed.
170S&F body in replacementof galvanized iron sheets with bottom tank of 22gauge ofdesert cooler, top cover of 24 gauge and side panels of 22 gauge GI sheet duly fitted with 2” thick wood wool pads including on heavy duty 22 guage frontgrill fitted with one piano type 5 Amps switch three speed selector switch of approved make with arrangement of changing the direction of air flow complete all as directed.
171Replacement of PVC water distribution system 4 way suitable for 3000/4000 Cum/Hrs of desert coolers complete with PVC Elbow, PVC Pipe (distribution system to side panel with elbow at end )heavy duty 15mm dia all as directed.
172Replacement of three speed selector switch complete with knob of approved make for desert cooler complete all as directed by Engr-in-Charge.
173Replacement of unserviceable side panels with wood wool 2" thick for desert cooler made out of 22 gauge plane GI sheet of existing size of desert cooler complete. (EachSet Of Three Panels) complete all as directed by Engr-in-Charge.
174Replacement of damaged/rusted front grill made out GI sheet of 20 gauge heavy duty complete with knob to separate the shutter and S&F one piano type switch 6 Ampand one three speed selector switch complete all as specified and as directed by Engr-in-Charge.
175Painting of desert coolers in side out side at site of work with two coats of synthetic enamel paint grey or any other shade (as approved) from out side complete including shutters top, bottom with spray painting machine and in side with black anti – corrosive paint (two coats) complete all as specified and directed.
176Taking down oldsplit/ window type Air Conditioner of any capacity and reinstalled at new location after completing serviceing including Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed
177Sub main wiring with two single core FRLSPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sq mm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4.0 sq mmas earth continuity conductorconnected to commen earth and earth dolly complete
178Supply and fixing FRP cooling tower complete with water proof fan motor, revolving unit with spray nozzle of capacity 15 TR AC plant at 4 ASD complete all as specified and as directed by Engr-in-Charge.
179Supply and fix reciprocating open type compressor SMC 2-65 Accel compressor complete with pump guage panel, crank case heater , suction and discharge valve complete all as specified and as directed by Engr-in-Charge.
180Supply in replacement of outdoor colling unit of split type AC 1.5 Ton capacity of existing make with copper tubing,heavy duty compressor complete all as directed by Engr-in-Charge.
181Supply and Install automatic copper wound voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay suitable for connection on single phase 50 HZ AC supply, designed for input voltage of 90 to 290 V and output voltage stablized at 215 to 240 V of Capacity 5 KVA complete with digital voltmeter and ammeter with time delay relay of 2-3 Minutecomplete all as specified and directed . Make: V-Guard/Microtech/Electric Field/AE
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail