Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-05-2023 | Revised BOQ and Tender Page Corrigendum | Other | 09-05-2023 |
| 2 | 01-05-2023 | Revised BOQ | BOQ | 09-05-2023 |
| Sl. No. | Item Description |
| 1 | REPAIR/MAINT OF INTERNAL WIRING INCL FITTING AND FIXTURES, CEILING / EXHAUST / AIR CIRCULATOR / WALL FANS, MCB DB\"S, HANGER LIGHTS, EARTHING, LIGHTENING CONDUCTORS, AVIATION / FLOOD LIGHTS AND CONNECTED WORKS FOR BLDGS AND HANGERS OF NORTH SIDE RUNWAY UNDER AGE E/M-I OF GE (NW) VASCO |
| 2 | Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents, regulators, bells, sockets, tube light fittings etc, removing the materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. including removing the debrisall as specified and as directed |
| 3 | Material & Labour forpoint wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wiredrawn in and including PVC Casing & Caping double lock/conduit pipe type of as required width (not less than 20 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling including terminatedin to Cast iron/pressed steel terminal box 60mm deep of required sizemade out of 2 mm thick MS sheet duly painted both sides with 3 mm thick plasticlaminated sheet top coverfixed with brass screw & cup washers complete all as specified and as directedfor the following :- |
| 4 | One light point controlled by one 5 Amp switch one way all as specified and as directed. |
| 5 | One ceiling fan/exhaust fan point controlled by one 5 Ampswitch one way all as specified and as directed. |
| 6 | One bell/buzzer point controlled by one bell push 5 Amp all as specified and as directed. |
| 7 | One light point controlled by two 2-way switches all as specified and as directed. |
| 8 | One 3/5 Pin, 5 Amp Switch socket out leton the independent board complete all as specified and as directed |
| 9 | One 3/5 Pin, 5 Amp Switch socket out leton the same board complete all as specified and as directed |
| 10 | All as per item No. 3.00 here-in before but point wiringdrawn in and includingconcealed PVC conduit in walls and ceiling not less than 20 mm dia ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling including terminatedin to Cast iron/pressed steel terminal box 60mm deep of required sizemade out of 2 mm thick MS sheet duly painted both sides with 3 mm thick plasticlaminated sheet top coverfixed with brass screw & cup washersfor one light point controlled by one switch5Amps, one way complete all as specified and as directed. |
| 11 | All as per item No 3.00 above, butwith 2.5 sqmm for One 3 pin 16 amps socket outlet point controlled by one 16 amps switchon the ndependent board complete all as specified and as directed. |
| 12 | Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed. |
| 13 | Material & Labour for sub main wiring with two runs of single core 2.5 Sqm, FRLSCopper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigidPVC casing caping (double interlock type) of suitable width medium dutywith all accessories such as Tees, elbows,junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLSinsulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. Note for srl item No. 7,8 & 9 :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measured as one unit |
| 14 | All as per item No 7 here in before, but two runs of single core 4 sqmm and one run of 2.5 sqmm cables as earth continuity conductor all as directed. |
| 15 | All as per item No 7 here in before, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed. |
| 16 | All as per item No 7 here in before, but four run of single core 10 sqmm and two runs of 6 sqmm cables as earth continuity conductor all as directed.Note for srl item No. 10 :-Four runs of cable, two runs of earth continuity conductor and one run of PVC casing caping/conduit shall be measured as one unit |
| 17 | Supply & Fixing in repairs Switch Piano flush type single pole one way 5/6 A, 240 V complete all as specified and as directed |
| 18 | Supply & Fixing in repairs modular Switch single pole one way 6 A,1 module, 240 V complete all as specified and as directed |
| 19 | Supply & Fixing in repairs modular Switch single pole one way 16 A, 1 Module,240 V complete all as specified and as directed |
| 20 | Supply & Fixing in repairs Bell push flush type, single pole, one way, 240 V, 5/6 A complete all as specified and as directed |
| 21 | Supply & Fixing in repairs Modular Bell push single pole, one way, 1 module,240 V, 6 Acomplete all as specified and as directed |
| 22 | Supply & Fixing in repairs Switch Socket combination 2 in 1, 5/6 Amp flush type, 240 V,complete all as specified and as directed |
| 23 | Supply & Fixing in repairsModular Socket outlet, 2/ 3 pin combined, 2 module, 6 Amp , 240 volts,complete all as specified and as directed |
| 24 | Supply & Fixing in repairs Switch Socket Combination 5A/16A, 5 in 1, 3 pin,240 volts complete all as specified and as directed |
| 25 | Supply & Fixing in repairs Modular Socket outlet 6A/16A, 2/ 3 pin, combined, 2 module, 240 volts complete all as specified and as directed |
| 26 | Supply & Fixing in repairs Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 voltscomplete all as specified and as directed |
| 27 | Supply & Fixing in repairs call bell ding dongAC, 230 volts, single pole all as directed |
| 28 | Supply & Fixing in repairs stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed. |
| 29 | Supply & Fixing in repairs modular fan stepelectronic regulator120 W , 2 module on the existing board all as directed. |
| 30 | Supply & Fixing in repairs modular flush metal box with inner & outer sheetfixed in 60 mm deep of followingsizefixed with screwfor mounting modular switches, Sockets, fan regulators etcfor existing electrical arrangements and connected to the existing electrical wires, making good the distrubed area with cement work and paints to match the existing backgound all as directed.(Note : S / F New modular switches, socket, fan regulators will be measured and paid separely) |
| 31 | Size of the boxessuitable for 1/2 module |
| 32 | Size of the boxsuitable for 3 module |
| 33 | Size of the box suitable for 4 module |
| 34 | Size of the box suitable for 6 module |
| 35 | Size of the box suitable for 8 module |
| 36 | Size of the box suitable for 12 module |
| 37 | Supply & Fixing in repairs White inner, outer cover plate Modular type with frame, 2 module |
| 38 | All as per item No 25 here in before but 3 module |
| 39 | All as per item No 25 here in before but 4 module |
| 40 | All as per item No 25here in before but 6 module |
| 41 | All as per item No 25 here in before but 8 module |
| 42 | All as per item No 25 here in before but 12 module |
| 43 | Supply & Fixing in repairs PVC Casing & Caping double lock type ofsize as required width (not less than 20/25 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling etc. complete all as specified and as directed. |
| 44 | Supply & Fixing in repairs PVCConduit of 20mm dia of ISI marked with all accessories of same grade concealed in wall / ceiling of as required (not less than 20/25 mm in dia) ISI marked medium grade white colour with all accessories of same grade complete all as specified and as directed. Note:- Rate quoted is inclusive of Cutting / Chasing of wall and finish to match existing original surface after fixing conduit including putty finish and painting etc. |
| 45 | Supply & Fixing in repairs knob suitable for Rotary type Flame proof switch in LM6,15A single pole 250V complete all as specified and as directed. |
| 46 | Taking down unserviceable any type of Main Switch, DB\"s including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed. |
| 47 | Supply & Fixing in repairs sheet metal enclosurewith a two pin and earth plug and socket complete with and includingone SP MCB 20 Amps complete all as specified. |
| 48 | Supply & Fixing in repairs MCCB DB VTPN, 4 way, prewired, double door, withsuitable bus bar including provision of one MCCB of 100 - 125 amps breaking capacity 25 KA , 4 pole,415 Vwithout MCB complete all as specified and as directed |
| 49 | Supply & Fixing in repairs MCCB DB VTPN, 6 way, prewired, double door, withsuitable bus bar including provision of one MCCB of 100 - 125 amps breaking capacity 25 KA , 4 pole, 415 Vwithout MCB complete all as specified and as directed |
| 50 | Supply & Fixing in repairs MCCB DB VTPN, 8 way, prewired, double door, withsuitable bus bar including provision of one MCCB upto 125 amps breaking capacity 25 KA , 4 pole, 415 V without MCB complete all as specified and as directed |
| 51 | Supply & Fixing in repairs MCCBof 100 - 125 Amps, 25 KA, 4 pole, thermal magnetic release , compact type suitable for MCCB DB verticle type as incomimg in theexisting / new DB \"s complete all as specified and as directed |
| 52 | Supply & Fixing in repairs MCCBof 175 - 200 Amps, 25 KA, 4 pole, thermal magnetic release , compact type suitable for MCCB DB verticle type as incomimg in theexisting / new DB \"s complete all as specified and as directed |
| 53 | Supply & Fixing in repairs MCB DB TPN 4 way , 415 V with suitable busbar ,double door complete all as specified and as directed. |
| 54 | Supply & Fixing in repairs MCB DB TPN 6 way, 415 V with suitable busbar,double door complete all as specified and as directed. |
| 55 | Supply & Fixing in repairs MCB DB SPN 8 way, 230 V with suitable busbar, double door type complete all as specified and as directed. |
| 56 | Supply & Fixing in repairs MCB DB SPN 4 way, 230 V with suitable busbar, double door type complete all as specified and as directed. |
| 57 | Supply & Fixing in repairs MCB DB SPN 12 way, 230 V with suitable busbar, double door type complete all as specified and as directed. |
| 58 | Supply & Fixing in repairs MCB 4P 40- 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 59 | Supply & Fixing in repairs MCB 4P32 amps 415 volts C curve, 50 HZ , AC 10 KA complete all as specified. |
| 60 | Supply & Fixing in repairs MCB TP40amps 415 volts C curve, 50 HZ,AC 10 KA complete all as specified. |
| 61 | Supply & Fixing in repairsMCB SPN 32 amps, 230 volts, C curve, 50 HZ AC 10 KA complete all as specified. |
| 62 | Supply & Fixing in repairsMCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 63 | Supply and fixing LED light fitting 18/20 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed |
| 64 | Supply & FixingEnergy efficient surface Mounted LED Luminire 20 watts 4\" long, 230 V , 50Hz, AC, with acrylic cover aluminium extruded body complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed |
| 65 | S & F in repairs Energy efficient surface Mounted LED Luminire 10 watts 2\" long, 230 volt , 50Hz AC with acrylic cover with alluminium body extruded complete with all accessories incl necessary three core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr complete all as specified and as directed |
| 66 | Supply & FixingEnergy efficient surface Mounted LED Luminire 40 watts 4\" long, with LED betten for surface mounting, pendent and conduit mounting high transmissitivity defuser and high lumen output completeall as specified and as directed. |
| 67 | Supply & Fixing in repairs recess/surface mounting high lumen LED flat panel 2\"X2\" 36 Watt, white powder coated CRCA housing with high power LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessaryfixing arrangementat any height and removing old unserviceable item complete all as specified and directed. |
| 68 | S&F in repairs LED batten 1x10 W inbuilt motion sensor based smart 2ft LED 230 volt 50hzwith alluminium extruded channel , powder coated with diffuser for glare free light inbuilt motion sensor prewired with 25 % dimmer illuminous in ideal timewith all accessories including two no of pvc box of size 75x75x20 mm for mounting fitting with all accessories integrated electronic driver complete all as directed. |
| 69 | S&F in repairs LED batten 1x 9 W inverter batten fitting working on AC supply in normal mode and DC supply in inverter mode with inbuilt battery back up of upto 4 hours with high efficency ,high lumen output , 2 ft LED 230 volt 50hz all accessories including integrated electronic driver complete all as directed. |
| 70 | Supply and fix in repairs inverter Bulb works on AC supply in Normal mode and DC supply in inverter mode, with inbuilt battery back up of upto 4 hours, high efficiency, high lumen output, LED bulb 9 W 240volts, 50Hz complete all as specified and directed. Note:- Taking down old CFL/LED bulb included in quated rate. |
| 71 | S&F for bulb holder suitable for 6 Aas per requirement ( batten, angled etc) complete as directed |
| 72 | S & F in repairs Integral decorative LED bollard mushroom shaped with B22/E27 bulb holder with cast alluminium housing and polymer diffuser with IP-65 protection of9 watts capacity all as directed. Note:- bulbs are measured and paid seperatelly. |
| 73 | S & F in repairs LED Bulb 15 watts 230 volts , 50 hz AC complete all as specified and directed by engr-in-charge. |
| 74 | M & L in replacementLED decorative post top lantern light with a modern look using new generation technology LED 40 W alluminium housing with clear acrylic diffuser includingcast aluminium pole cap complete with accessories all as directed. |
| 75 | S&F in repairs integral LED aviation light comprising of aluminium housing with polycarbonate enclosure with necessary fixing arrangement such as suitable size of GI pipe, fixing clamp, brackets, etc., complete all as specified . |
| 76 | S & F in repairs 60 watts LED building security light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights all as specified. |
| 77 | Supply and fixin replacement of 90 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED\"s must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt.The luminarie should have 5 KV surge protection,PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided.The manufactures LOGO must be embossed/Engraved in the housing of the luminarie complete all as specefied and directed. |
| 78 | M & L for Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc. |
| 79 | Supply and fixin repairs LED flood light fitting 200 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED\"s and electronic driver, internally prewiredincluding necessary fixing arrangement on RCC pole by providingMS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed. |
| 80 | Supply and fixin repairs LED flood light fitting 250 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED\"s and electronic driver, internally prewiredincluding necessary fixing arrangement on RCC pole by providingMS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed. |
| 81 | Supply and fixin repairs LED Highbay luminaire 1x 150 watts energy efficient saving environment friendly and robust open type verical highbay LED Luminaire with high power COB LED as light sourceall as specified and directed. |
| 82 | Supply and fixin repairs LED Highbay luminaire 1x 200 watts energy efficient saving environment friendly and robust open type verical highbay LED Luminaire with high power COB LED as light sourceall as specified and directed. |
| 83 | Material & Labour for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode complete all as specified and as directed including connections and testing on completion. |
| 84 | Material & Labour Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, includingnecessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 40 mm dia pipe of requiredlength for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion. |
| 85 | Note for Srl item No. 71 & 72 Quoted rate deemed to include fornecessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 for earth chamber, 40 mm thick RCC Cover with 8 mm dia CTD bars 10 cm C/C on both ways as reinforcement,removal of surplus soil, site clearance etc. |
| 86 | M&L for testing earth resistance of earthingpit with help of earth resistance megger in the presence of MES Staffand countersign by engr-in-charge and submit report to sub-division for future correspondance all as directed. |
| 87 | M & L for ceiling fan 1200 mm sweep BLDC fan with suitable RPM ,single phase 26/28 watts , 230 volt ,50 Hz AC low energy consumption remote control ,anti corrosive aluminium blade and body complete fitting all as directed. |
| 88 | Material & Labour for exhaust fan AC single phase 230V of size 300 mm sweep heavy duty with louver and connecting up including provision of flexible copper wire three core of size 23/0.0076 from ceiling rose/PVC connector to exhaust fan all as specified. |
| 89 | Material & Labour for exhaust fan AC single phase 230V of size 450 mm sweep heavy duty with louver and connecting up including provision of flexible copper wire three core of size 23/0.0076 from ceiling rose/PVC connector to exhaust fan all as specified. |
| 90 | Supply & Fixing in repairs Switch Flameproof WP Rotary type with termination box in LM6,15A single pole 250V complete all as specified and as directed |
| 91 | Supply & Fixing in repairsFlame proof Switch socket combination with termination box in LM6,16A single pole 250Vcomplete all as specified and as directed |
| 92 | Supply & Fixing in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8 mm dia 25mm long hexagonal, Head screwcomplete all as specified and as directed |
| 93 | Supply & Fixing in repairs Aluminum strip of size 25 x 3 mm in repair with saddles and fixing screws etc. for roof conductors and down conductors above ground and fixing in the same location with new nuts and bolts of suitable size and length and connected to air termination rod on top of the hangar complete all as directed. |
| 94 | S & F in repairs GI wire 4 mm dia for connecting to DB to earthing as required for safty, fixing screws etc complete all as directed. |
| 95 | Material & Labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work for pole coping all as dirceted. |
| 96 | Taking down carefully ceiling fans of size 1200/1400 mm sweep at any height of any sweep/make/model after disconnecting electric connection and dismantling andopening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins,cater pins,coupling bolt, capacitor holder ,terminal adoptor,screws, nuts, spring washers for blade/body etc and replacement of components/ accessories such as ball bearings,gun metal bushes,capacitor,canopy top& bottom, shackle clip assembly and assembling of all parts including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed. |
| 97 | Note :- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only.(ii)Rewinding of fan motor,painting will be measured and paid separetly under relevant item of schedule.(iii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate |
| 98 | All as per item No. 83, 83.01 above,butexhaust fan of size upto 300 mm and 380 mm sweep all as directed. |
| 99 | All as per item No. 83, 83.01 above,butexhaust fan of metal body size above 380 mm and upto 450 mm sweep all as directed. |
| 100 | Material and labour for painting to ceiling fan of size 1200 mm sweep to 1400 mm sweep complete body, blades & down rod etc of any sweep/make/model with two coat of synthetic enamel paintby using electric spray machine similar to match with existing colour after preparation surfaces including marking of MES Number with black paint complete all as specified and directedNote for Srl item No. 86 and 87 :-(i) Painting work shallbe carried out after dismantling of ceiling fan / Exhaust fan(ii) Rate quoted is inclusive of taking down old fan and refixing including connecting up complete. |
| 101 | All as per item No. 86 above,butexhaust fan of metal body size above 300 mm to 450 mm sweep all as directed. |
| 102 | Material and labour for rewinding of ceiling fan motorof size 1200 mm sweep to 1400 mm sweep of any make/model/type with new supper enamelled copper winding wire ofsimilar gauge and number of turns as existing,including cleaningthe motor properlyand applyingvarnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motorcomplete all as specified and directed. |
| 103 | All as per item No 88 here in before but of exhaust fan of size upto 300 mm sweep all as directed. |
| 104 | All as per item No 88 here in before but of exhaust fan of size above 380 mm and upto 450 mm sweep all as directed. |
| 105 | Supply & Fixing in repairs capacitor of 2.5/3.15/4.0 mfd capacity for ceiling fan of any sweep all as specified. |
| 106 | Supply only shackle clip assembly with rubber bush reel and nuts,bolts and washers suitable for ceiling fan of any sweep/type. |
| 107 | Supply only ball bearing suitable for ceiling fan/exhaust fan/air circulator/pedestal fan any type all as directed. |
| 108 | Supply only split pin as per sample suitable for ceiling fan all as directed. |
| 109 | Supply only MS nut bolt with split pin as per sample and as directed. |
| 110 | Supply only plastic conopy top and bottom with tighten screw suitable for ceiling fan of any sweep/type. |
| 111 | Supply and fix down rodmade of MS pipe medium grade 15mm dia of 300/600mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and includingpainting todown rodwith two coat of synthetic enamel paintover one coat of red oxide primer. |
| 112 | Supply and Fix in repair Ceiling Fan motor with body complete suitable 1200 mm Sweep matching to blade of existing ceiling fan all as specified and as directed. |
| 113 | Supply and Fixin repair Fan Blade set of three suitable of any make and sweep up to 1200 mm sweep matching to existing ceiling fan all as specified and as directed.Note:- Fan Blade make and size shuld be supply with the mach of under relivent item of Sch Aserial No 106 as above. |
| 114 | Supply and fix copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade 3 core ;0.75 sqmm and including connecting up ceiling fan and ceiling rosecomplete all as specified and directed |
| 115 | M &L for removing old unserviceable motor assembly from exhaust fan and fixing new exhaust fan motor assembly suitable of size 300/380 mm sweep andincluding nuts, washers, and testing complete all as specified and directed. |
| 116 | Material & Labourfor removing old unserviceable blade assembly from exhaust fan and fixing new exhaust fan blade assembly suitable of size 300 mm to 380 mm sweep andincluding locking nuts and testing complete all as specified and directed. |
| 117 | M &L for removing old unserviceable motor assembly from exhaust fan and fixing new exhaust fan motor assembly suitable of size 450 to 600 mm sweep andincluding nuts, washers, and testing complete all as specified and directed. |
| 118 | Material & Labourfor removing old unserviceable blade assembly from exhaust fan and fixing new exhaust fan blade assembly suitable of size 450 mm to 600 mm sweep andincluding locking nuts and testing complete all as specified and directed. |
| 119 | Material & Labourfor removing old unserviceable motor assembly from air circulator fans and fixing new aircurlator fan motor assembly suitable of size 450-600 mm sweep andincluding nuts, washers, and testing complete all as specified and directed. |
| 120 | Material & Labourfor removing old unserviceable blade assembly from Air circulator fans and fixing new blade assembly suitable of size 450 mm to 600 mm sweep air circulator andincluding locking nuts and testing complete all as specified and directed. |
| 121 | Supply & Fixing in repairs GI clamp/Saddles for fixing of XLPE cable of any size on the wall surface incuding drilling in wall, fixing of new screws suitable length complete all as specified & directed by Engineer-in-Charge. |
| 122 | Supply and fixing ofPVC electricalinsulation tape 18 mm width in 6-8 mtr roll all as directed. |
| 123 | REPAIRS / MAINTENANCE OF EARTHING AND CONNECTED WORKS AT NORTH SIDE RUNWAY |
| 124 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable/errection of poles complete all as specified and directed. |
| 125 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and levelling of bottom surface to required level complete all as specified and directed. |
| 126 | Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface to match the original existingfinish complete all as specified and directed . |
| 127 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed |
| 128 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed |
| 129 | Supply and lay Double walled corrugated pipe (DWC ) confirming to IS 14930 heavy duty 63/50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed. |
| 130 | M & L for LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade 70 Sq mm, 3½ core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) completeincluding taking down old unserviceable as specified. Note:-(a) Excavation, Concrete cable protection cover, pipe, PCC work for road crossing/hard standing and Sand for cushioning will be measured and paid separately.(b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), new nut, bolt and washers of required size/description are deemed to be includedin this rate. |
| 131 | M & L for LT heat shrinkable Straight through cable Jointing kit suitable for 3.5 core 70 to 150 Sqmm aluminium cable all as directed. |
| 132 | Supply and fix or laying in trenches / on wall / poles / structures in repairs GItubing light grade of 80 mm dia for road crossing for cable protection including necessary suitable size MS flat fixing clamps, fixing screws complete all as directed. |
| 133 | M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed including demolish existing earth pit taking out old materials. |
| 134 | M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thickby mean of nuts / bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed. |
| 135 | S & F in repairs Galvanised iron strip 32 x 6 mm buried in ground/fixed on walls/ceilings by using suitable size GI saddles etc including taking out old one all as specified. |
| 136 | S & F in repairs Copperstrip 32 x 6 mm buried in ground/fixed on walls/ceilings by using suitable size GI saddles etc including taking out old unserviceable strip all as specified. |
| 137 | Material and lobour for Servicing of earth pit structure by disconnecting earth strip by opening nuts and bolts 4 pole structures LT/HT including checking all joints , jumbers etc for any loose connection , replacement of burnt jumber with new one , replacement of rusted nut bolts and apply petrolium jelly for all moving contacts all as directed.Note:- All the spares required for the work is included in the quoted rate. |
| 138 | Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycablewith PVC insulated 4 core stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tapeandoverall PVC sheathed4 sqmm nominal cross section in service connection/light connections in poles all as directed |
| 139 | M & L for removing vegetation, grass, scrubs and bushes or any small tree branches growing in Sub station yard along with fencing, around the pole, under the HT/LT transmission lines, yards or any description by mannually/mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. |
| 140 | M & L for Cutting and trimming of tree branches 3 mtr all around of any size obstructing lumination of street light and touching LT/HT Over head line incl removing trimmed tree branches all as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail