|
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil-By manual means |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m. -All kinds of soil |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading torequired slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitablemethod complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:4:8 ( 1 Cement: 4 fine sand : 8 graded well burnt brick aggregate 40 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level: 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size). Beam & Roof |
| 8 | Centering shuttering including struttings, propping etc. and removal of form work for: - Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 9 | Centering shuttering including struttings, propping etc. and removal of form work for: Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank |
| 10 | Centering shuttering including struttings, propping etc. and removal of form work for: -Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank |
| 11 | Centering shuttering including struttings, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform with timber planks |
| 12 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars |
| 13 | First class brick work in foundation and plinth including cost of all materials as required complete:-cement mortar (1:6) |
| 14 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete.In cement mortar 1:5 ( 1 cement :5 fine sand ). |
| 15 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-In cement mortar 1:5( 1 cement : 5 fine sand ) |
| 16 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:Using M.S. angels 40x40x6 mm for diagonal braces. |
| 17 | Providing and laying ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete. Anti-Skid Tiles- Ceramic Tiles 1st quality 300 x 300mm in all shades anddesigns |
| 18 | Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed withordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete. |
| 19 | 12 mm cement plaster of mix. In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
| 20 | 15 mm cement plaster on the rough side of single or half brick wall of mix:In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
| 21 | Distempering with 1st quality acrylic washable distemper (ready mixed) of approved brand and manufacture and of required shade and colour complete as per manufacurer\"s specification on new work ( two or more coats ). [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 22 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on new work ( two or more coats applied @ 3.84 kg/10 sqm) complete. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 23 | Finishing with epoxy paint ( two or more coats ) of approved brand and manufacture at all locations prepared and applied as per manufacturer\"s specification on new work including appropriate priming coat, preparation of surface etc. complete.[Payment shall be made after submission of Test Certificate issued by the Manufacturer] On steel work |
| 24 | Neat Cement Punning |
| 25 | Providing and fixing a pair of white vitreous china foot rests of standard pattern for squatting pan water closet: 250x130x30 mm pair |
| 26 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 27 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 markedwith cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 28 | Providing and fixing gun metal non-return valve of approved quality (screwed end): 25 mm nominal bore |
| 29 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction ofEngineer in Charge.15 mm nominal outer dia .Pipes. |
| 30 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes& fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.25 mm nominal outer dia . |
| 31 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore each |
| 32 | Providing and fixing soil, waste and vent pipe. 100mm dia Sand cast iron S&S pipe as per IS 1729 |
| 33 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion Bend 87.5° 110mm |
| 34 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg / cm2)conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 75 mm OD |