| 1 | WBM Grading 3Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as perTechnical Specification Clause 405. By Manual Means |
| 2 | Tack coat using VG-10 grade bitumen Over dry and hungry bituminous surfaces @0.40 kg/sqm |
| 3 | 20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing courseon a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C asper Technical Specification Clause 508. Case - I By Manual Means Bitumen (VG-10) |
| 4 | Seal CoatProviding and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall usingType Bas per Technical Specification Clause 510 |
| 5 | Excavation in foundation for retaining & brest walls in all types of soils and rocks including lead, lift and disposal of surplus material as per direction of engineer - in - charge |
| 6 | Providing concrete for plain/ reinforced concrete in open foundations complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6 |
| 7 | Providing concrete for plain/ reinforced concrete in open foundations complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:2:4 |
| 8 | kilometre StoneReinforced cement concrete M15 grade kilometre stone/local stone of standarddesign as per IRC:8 fixing in position including painting and printing, etc as perdrawing and Technical Specification Clause 1703 Ordinary Km stone |
| 9 | 200 m stone for hectometer |
| 10 | Road Delineators / Vertical Guide Posts:Providing and fixing of Standard Metal Delineator consisting of minimum retro reflective unit exposed area of 330 sqcm, full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67 and meeting the coefficient of retro reflection values as per ASTM D 4956 Type XI table specification with pure polyester powder coating with the minimum thickness of powder coating of not less than 40 micron. The posts shall have ellipsoidal or circular design with the height of the pole shall be 800 to 900 mm above the ground with about 200 to 300 anchored with PCC M-15 onto the ground. The front and back faces of the delineator should be curved with a radius of not more than 200 mm and with delta angle (or central angle of curve) lying between 20o and 30 o, to increase the visibility of the delineator for vehicles moving in continuous curves. The delineator shall have sufficient arrangement to make the reflective sheets vandal-proof. Including all test report and warranties as per IRC 67 and IRC 79 |
| 11 | Providing and fixing of corrosion resistant 2mm thick Type IV retroreflective cautionary, mandatory, informatory sign board with 7 year warranty as per IRC:67, made of high intensity sheeting fixed over ACP (Aluminium Composite Panel) 3 mm thick (including framing andbracing with fabrication, plotting, pasting, riveting, taping and nut, bolts, washers and rivets etc for fixing), supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing, issued in original by retro-reflective sheeting manufacturer having operations in India by their indian subsidary. 60 cm x 60 cmfor village name |
| 12 | 60cm circular for speed limit and showing type of road |
| 13 | Direction and Place Identification signs upto 0.9 sqm size board Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 |
| 14 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 15 Nominal mix (1:2.5:5) |
| 15 | Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 ( i Concrete Required for Vertical post Fixing will be paid extra) |
| 16 | Stone masonry in cement mortar for substructure complete as per drawing &technical specification Clauses 702, 704, 1202 and 1204 RR 1:5 |
| 17 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&Pand royaltiies etc.(As per PWD Uttarakhand specifications) |
| 18 | Providing concrete for plain/ reinforced concrete inSubstructure complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203 RCC M 25 |
| 19 | Supplying, fitting and placing with HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202(The reinforcement steel shall be procured from original (primary) steel producersas per clause no. 2011.3.1 of MORD specifications (First revision\"2014) and IS1786:2008 clause no. 1.6) |
| 20 | Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
| 21 | Hand packed stone filling in the back ofretaining walls by locally available approved stone including supply of all material ,labour T&P etc. |
| 22 | As per drawing 40% plum ( Loose stone ) |
| 23 | White washing of parapet walls of CD work and tree truncks White washing two coats on parapet walls and tree trunks including preparation of surface by cleaning scraping etc. as per technical specifications Clause 1915 |