The Kerala Land Development Corporation Ltd has published Tender For Nabard Ridf Xxvii- Infrastructural Development Works In District Agricultural Farm Peringamala In Thiruvanathapuram District Phase Ii (Solar Hanging Fencing, Chain Link Fencing, Solar Fencing And Trench Work). Submission Date for this Tender is 02-05-2023. Civil Work Tenders in peringamala Kerala. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SOLAR FENCING MATERIAL- 1000M |
2 | od364728/2022_2023: Supplying, installing and commissioning of ENERGIZER::Should be Battery Operated switch to high, medium and low power settings. Solar panel option to recharge 12-Vol Battery. Auxiliary supply provision for 23 V ac should be there.Should operate at one / different fences independently Should be capable to energize the length of fence up to 5 km. (5 stands) should be suitable for other requirements of the work.Each are shall have is own Energizer and alarming system. Any intrusion/ unwanted activation of the fence should be suitable annunciation with audio alarm system.Operating voltage at 590 k load 10 KV Maximum. Other parametres with 1 K Load,Operating voltage- 6.0 - 8.0 Kv - At High setting O/P energy - 3.5 to 5.1 Peak current - 7.0 - 8.0 Amps at high setting, RMS Current 2.4 - 2.8 Amps at high setting, Output charge - 1.0 - 1.4 million Col - at high setting, Fib Energy - 3.5 - 4.5 MCA - at high setting, pulse duration - 0.01 - 3 million - sec, Pulse interval - 1.1 - 1.4 sec. Should be Battery Operated swtich to high, medium and low power settings. Solar panel option to recharge 12-Vol Battery. Auxiliary supply provision for 23 V ac should be there.Should operate at one / different fences independently Should be capable to energize the length of fence upto 5 km. (5 stands) should be suitable for other requirments of the work.Each arre shll have is own Energizer and alarming system. as per specification Include as per the direction of KLDC officials |
3 | od364729/2022_2023: Supplying, installing and commissioning of Charge Controller Unit 12 V 12AMP. Include as per the direction of KLDC officials |
4 | od364731/2022_2023: Supplying, installing and commissioning of LIGHTNING DIVERTING KIT:Must be capable of diverting stray lightening. The diverter assembly must be adjustable for spark gaps. Lightning diverter kit should be as close as possible to the Energizer Adequate earthing to be provided. Include as per the direction of KLDC officials. Include as per the direction of KLDC officials |
5 | od364732/2022_2023: Supplying of TOOL KIT: Should contain: Wire tightner handle, Twisting tool, Pliers, Double ended spanner for clamp tightning. Include as per the direction of KLDC officials |
6 | od364733/2022_2023: Supplying and installing of 12 V BATTERY CHARGER 10 Amp. Include as per the direction of KLDC officials. |
7 | od364734/2022_2023: Supplying of Digital Volt meter. Include as per the direction of KLDC officials |
8 | od364735/2022_2023: Supplying of multi meter. Include as per the direction of KLDC officials |
9 | od364736/2022_2023: Supplying and installing of LEAD OUT CABLE: Must be double insulated with standing 15 kv voltagages. Inner core wiremust be hot dip galvanized. For under gate and base unit connection. Include as per the direction of KLDC officials |
10 | od364737/2022_2023: Supplying and installing of Joint clamp: Joint clamps Positive locking mechanism Zinc coating of more than 25 microns. Include as per the direction of KLDC officials |
11 | od364738/2022_2023: Supplying and installing of SUPER STRAIN INSULATOR: Strain insulators for End or Corner post: Made of high quality industrial Plastic - Virgin Nylon rated for 15 KV UV stabilized. Reel insulators: made of virgin Polypropylene plastic rated for 15 KV UV stabilized. UV stabilized & Rain water run off should be provided on the insulator. Include as per the direction of KLDC officials |
12 | od364739/2022_2023: Supplying and installing of Winding 14 G WIRE SWG galvanized:14 G WIRE SWG galvanized. Include as per the direction of KLDC officials |
13 | od364740/2022_2023: Supplying and installing of SUPER EARTH KIT: Earthing system Must contain earth mixture capable of retaining moisture. 8 mm. Diametre stainless steel rod, non rusting quality of at least 4 feet length Should be capable of providing proper earthing to the system. Include as per the direction of KLDC officials |
14 | od364741/2022_2023: Supplying and installing of WIRE TIGHTNER In suit tighteners for proper tensioning of wires should be made from A1-alloy non rusting quality:Wire tighteners In suit tighteners for proper tensioning of wires should be made from A1-alloy non rusting quality. Include as per the direction of KLDC officials |
15 | od364742/2022_2023: Supplying and installing of T ANGLE POST 8 FEET LENGTH:Intermediate posts More than 60 microns galvanized "T" section post 8.5 feet long 25 x 25 x 3 mm to be inserted 1.5 feet in ground. Include as per the direction of KLDC officials |
16 | od364743/2022_2023: Supplying and installing of ACSR 12 G WIRE high tensile wire galvanized 230-300 GSM. Include as per the direction of KLDC officials |
17 | od364744/2022_2023: Supplying and installing of REEL INSULATOR made of Polypropylene 15 KV UV stabilized. Include as per the direction of KLDC officials |
18 | od364745/2022_2023: Supplying and installing of 12 V tubular battery, 100 AH: 12 Volts, 100 AH low maintenance Free battery with 4 year replaceable warranty Must be capable of diverting stray lightening. The diverter assembly must be adjustable for spark gaps. Lightning diverter kit should be as close as possible to the Energiser Adequate earthing to be provided.Must be of from reputed companies. Include as per the direction of KLDC officials |
19 | od364746/2022_2023: Supplying and installing of ONE inch G.I Support post (7 feet). Include as per the direction of KLDC officials |
20 | od364747/2022_2023: Supplying and installing of GI CORNER POST 2 INCH 8.50 FEET LONG:Section/ Corner/ End/ pull through posts -50 NR Class "R" pipe 8.5 feet long Hot dip galvanized to more than 60 microns. Stay support 25 mm. diameters with brackets also hot dip galvanized. Must include fasteners. Posts must be grouted 1.5 feet in 2 x 2 x 2 feet size P.C. C in 1:3:6, 20mm. Include as per the direction of KLDC officials |
21 | od364748/2022_2023: Supplying, installing and commissioning of Solar panel 150 Watt 12 V: 150 Watts, 12 Volts rating with minimum 15 years warranty against manufacturing defects, Must be of good efficiency durability and reliable one should be from reputed companies with more than 15 years of experience in solar panel manufacturing. Include as per the direction of KLDC officials |
22 | od364749/2022_2023: Supplying and installing of "C" CLAMP 50 mm HOT DIPPING GALVANIZED for fixing corner and supporting posts. Include as per the direction of KLDC officials |
23 | od364750/2022_2023: Supplying and installing of Warning sign: Warming sign boards, polyethylene plastic with statutory color and signs Yellow with black lettering in local language. Include as per the direction of KLDC officials |
24 | od364752/2022_2023: VDA :V.D.A for Knife weeding heavy growth F.S.R rate. |
25 | Civil work for POST FOOTING and INSTALLATION charges |
26 | 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
27 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
28 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
29 | od352832/2022_2023 : Installation charges. Fencing line should install as per std specification and from the direction of Officer in charge |
30 | Solar Hanging Fence -2000 m |
31 | od320409/2022_2023 : Supplying, installing and commissioning of ith the
following specifications 24V ENERGIZER, must be from a
reputed company, must confirm to IEC 603352-76 and all
National and International standards of safety. Switch to high, medium and low power settings. Solar panel option to recharge 12 volt battery. Full and reduced power output terminals can be operated at once on different fences independently. Should possess the following output characters - Peak o/p voltage not more than 10 KV on 50 K load. - O/p energy 3.5 J minimum - Pulse duration 1.01-3.0 m. sec - Pulse interval 1.1-1.4 sec - Peak current 7.0-8.0 AHigh - RMS current 2.4-2.8A-High- Charge 1.0-1.4 m CHigh 3 years warranty against manufacturing defects HANGING FENCE. Include as per the direction of KLDC Officials |
32 | od320410/2022_2023 : Supplying, installing and commissioning of SOLAR MODULE FOR HANGING FENCE.Monocrystalline With the following Specification 150
watts, 12 volts rating with minimum 10 years warranty
against manufacturing defects. Solar charge controller to regulate the charging of the battery. Include as per the direction of KLDC Officials |
33 | od320411/2022_2023 : Supplying and installing of MODULE STAND WITH BOX.MODULE STAND WITH BOX With MS thickness tilted to 13-15 degrees. Include as per the direction of KLDC Officials |
34 | od320412/2022_2023 : Supplying and installing of BATTERY.Must have
12 Volts, 100 AH maintenance free (Exide or Base or
okaya) battery with at least 3 years guarantee.. Include as per the direction of KLDC Officials |
35 | od320413/2022_2023 : Supplying, installing and commissioning ofLIGHTNING DIVERTER.Must be capable of diverting stray lightening.The diverter assembly must be adjustable for spark gaps.; Adequate earthing to be provided. Include as per the direction of KLDC Officials |
36 | od320414/2022_2023 : Supplying and installing of EARTHING SYSTEM.Must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rod non rusting quality of 4 feet long. Include as per the direction of KLDC Officials |
37 | od320415/2022_2023 : Supplying and installing of SUPER STRAIN INSULATER. >Must be of polycarbonate material and should withstand of 16 KV..Include as per the direction of KLDC Officials |
38 | od320416/2022_2023 : Supplying and installing of WARNING SIGNS.Poly ethylene plastic with statutory colors and signs. Include as per the direction of KLDC Officials |
39 | od320417/2022_2023 : Supplying and installing of LEAD OUT CABLE.Must be double insulated withstanding 15 KV voltage and Inner core wire must be GI. Include as per the direction of KLDC Officials |
40 | od320418/2022_2023 :Supplying and installing of T-SHAPED GI SQUARE TUBE. 17 Feet length, 14gauge, class B pipe of 2 inches inner diameter, non rusting quality with ISI standards. (above the ground 14 feet and top pipe 3 feet).Include as per the direction of KLDC Officials |
41 | od320419/2022_2023 : Supplying and installing of STAINLESS STEEL WIRE 1.5mm 304 grade, non rusting quality for main line.. Include as per the direction of KLDC Officials |
42 | od320420/2022_2023 : Supplying and installing of STAINLESS STEEL WIRE 1.2.304 grade, non rusting quality for earthing line and middle line (for Horizontal Line at 4 feet above the ground). Include as per the direction of KLDC Officials |
43 | od320421/2022_2023 : Supplying and installing of GI WIRE ROPE. GI WIRE
ROPE 1.5mm and non rusting quality for hanging line. .Include as per the direction of KLDC Officials |
44 | od320422/2022_2023 : Supplying and installing of BULLETS (Connectors). BULLETS
(Connectors) of copper material coated with stainless steel having an inner core hole size of 2.5 mm diameter, 2 cm length..Include as per the direction of KLDC Officials |
45 | od320423/2022_2023 : Supplying and installing of BOTTOM FIXTURE.BOTTOM FIXTURE that includes A. GI SQUARE TUBE of 32 inches length, 2.5 inches inner diameter, 14 gauge, nonrusting material with ISI standards. B. BUSH- UV stabilized, heat resistant, non electrical conductible poly propylene material for fixing inside the GI square tube. Include as per the direction of KLDC Officials |
46 | od320426/2022_2023 : Supplying of DIGITAL VOLT METER. Include as per the direction of KLDC Officials |
47 | od320427/2022_2023 : Supplying of TOOL KIT(cutting pliers, twisting toolkit,multi meter, Volt meter, double ended spanner.). Include as per the direction of KLDC Officials |
48 | Civil work for Hanging fencing- 2000m |
49 | 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
50 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
51 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
52 | 13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
53 | Civil work for Hanging fencing- 2000m |
54 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
55 | 4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
56 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
57 | 10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
58 | 16.70.1 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm |
59 | 13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
60 | elephant trench-3500m |
61 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
62 | 60.7.1 : DRYRUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site |
63 | 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
64 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy