Provision Of Panel Room With Lt Panel At Kalpakkam Under Age ( I ) Navy Chennai ( Tender Id: 2023_Mes_588816_1 ) 82537 / E8. 1 Schedule A Part-I [ B / R Works ] 2 Surface Excavation N Exc 30Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 3 Excavation In Trenches N.Exc 1.5 M Wide And N.Exc 1.5 M In Depthforfoundation Etc And Getting Out In Hard / Dense Soil Complete All As Specified And Directed. 4 Excavating Over Areas, N Exc 1.5 M Deep And Getting Out In Hard / Dense Soil Complete Allas Specified And Directed. 5 Material And Labour For Pcc ( 1:4:8 ) , Type D-2, Using 40Mm Graded Stone Aggregate As In Foundation, Filling And Mass Concrete Complete All As Specified And Directed. 6 Material And Labour For Providing Reinforced Cement Concrete, Rcc Type M-30, Design Mix, Using 20Mm Graded Stone Aggregate In Foundations, Including Rafts, Footings, Foundation Beams, Plinth Beams, Bases For Columns Etc..., Basement Slabs, Under Reamed Piles And Mass Concrete Complete With Joints To Match All As Specified And Directed. 7 Material And Labour For Providing Reinforced Cement Concrete, Rcc M-30, Design Mix, Using 20Mm Graded Stone Aggregate In Columns, Pillars, Piers, Posts And Struts All As Specified And Directed. 8 Material And Labour For Providing Reinforced Cement Concrete, Rcc M-30, Design Mix, Using 20Mm Graded Stone Aggregate In Beams, Cantilevers, Bressummers, Lintels Over 1.5 Span All As Specified And Directed. 9 Material And Labour For Providing Precastreinforced Cement Rcc M-30, Design Mix Using 20Mm Graded Stone Aggregate In Chajjas Complete All As Specified And Directed. 10 Material And Labour For Providing Precastreinforced Cement Rcc M-30, Design Mix Using 20Mm Graded Stone Aggregate In Slabs Complete All As Specified And Directed. 11 Material And Labour For Formwork Flat Rough Finished Surface Of Concrete Flat To Side Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams And Soffits Of Foundations And Plinth Beams And Similar Work Vertical Or To Batter Complete All As Specified And As Directed. 12 Material And Labour For Formwork Rough Finishedsquare, Rectangular Or Polygonal Rough Finished Surface Of Concrete Falt To Sides Of Concrete Pillars, Posts, Struts, Piers, Columns And Stanchionscomplete All As Specified And As Directed. 13 Material And Labour For Formwork Flat Rough Finished Surface Of Concrete To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressumers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc Also Splays Between Floors And Beams Etc... Complete All As Specified And As Directed. 14 Material And Labour For Formwork To Flat Rough Finished Surfaces Of Concrete To Sides And Soffits Of Suspended Slabs Such As Roof Slabs, Landings And Similar Work Not Exceeding 200Mm Thick ( Horizontal Or Sloping ) Complete All As Specified And As Directed. 15 Material And Labour For High Strength Deformed Tmt Bars 10Mm Diaand Over As In Reinforcement Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Complete All As Specified And As Directed. 16 All As Per Serial Item No. 15 Here-In-Before But 6Mm To 8Mm Dia Bars As In Stirrups, Spacers And Binders Complete All As Specified And Directed. 17 Returning, Filling In, Including Spreading Levelling, Watering And Well Ramming In Layersnexc25 Cm In Any Soil Complete All As Specified And As Directed. 18 M&L Removing Excavated Soils Not Exceeding 50 M And Depositing Where Directed At A Level Not Exceeding 1.5 M Above The Starting Point Complete All As Specified And As Directed. 19 M & Lbrick Work With Modular Flyash Bricks Straight Or Curved On Plan Exc 6 M Mean Radius Built Incm1 : 6 Complete All As Specified And As Directed. 20 M & L Rendering For 10Mm Thick In Cement Mortar ( 1:6 ) On Other Than Fair Faces Of Internal Bricks Or Concrete Surfaces Finished Fair And Even Complete All As Specified And Directed. 21 M & L Rendering For 10Mm Thick In Cement Mortar ( 1:6 ) On Other Than Fair Faces Of Internal Bricks Or Concrete Surfaces Finished Even And Smooth With Using Extra Cement All As Specified And S Directed. 22 M&L For Rendering 15 Mm Thickin Cm 1:4 . Mixed With Water Proofing @ 2% By Weight Of Cement With Fair & Even Plasters Finshes Complete All As Specified And As Directed. ( Note :- Wpc Will Be Measured Separately ) . 23 M & L Rendering 5Mm Thick On Ceiling In Cm 1:3 Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 24 M & L Preparing Newly Plastered Surfaces Of Celings And Applying Three Coats Of White Wash Complete All As Specified And As Directed. 25 Material And Labour For Preparation Of New Plastered Wall Surfaces By Vacuum Based Sanding Machine And Applyingtwo Coats Of Interior Emulsion / Distemper Oil Emulsion Over A Coat Of Primerincluding Applying One Coat Of 3Mm Tk Wall Care Putty, Using Mechanical Tool / Auto Roller Complete All As Per Manufacturer Instruction And As Directed.Note: All Work Shall Be Carried Out By Approved Applicator Of Paint Manufacturer Only. The Same Shall Be Approved Before Carrying Out The Work From Age ( I ) . Contractor Should Submit Auth Applicator Certificate Before Execution Of Work. 26 Material & Labour Prepartion Of New Plastered Surface By Vacuum Based Sanding Machine Andfinishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) Using Mechanical Tool / Auto Roller Complete All As Per Manufacturer Instruction And As Directed.Note: All Work Shall Be Carried Out By Approved Applicator Of Paint Manufacturer Only. The Same Shall Be Approved Before Carrying Out The Work From Age ( I ) . Contractor Should Submit Auth Applicator Certificate Before Execution Of Work. 27 Material And Labour For Providing Moorum / Red Bajri, Laid In Layers Not Exceeding 15 Cms Thick, Filling In Roads, Spread, Rolled And Consolidated To Gradient And Camber As Required, Complete All As Specified And Directed. 28 M&L For Hardcore Of Gauge N Exc. 63 Mm, Broken Stone Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And Directed. 29 M & L 100 Mm Thick Pcc1:4:8Type D-2 ( Using 40 Mm Gradedaggregate ) In Subbase Complete All As Specified. 30 M & L 40 Mm Thick Pcc1:2:4Type B-1 ( Using 20 Mm Gradedaggregate ) In Flooring And Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified. 31 M & L 100 Mm Thick Pcc1:2:4Type B-1 ( Using 20 Mm Gradedaggregate ) Inflooring Of Ramp And Finishing The Surface Even And Smooth Without Using Extra Cement Icluding Spike Rolling To Surface Surface Or Making Impressions Of Expanded Metal Whilst The Concrete Is Green Complete All As Specified. 32 M & L 75 Mm Thick Cement Concrete Type C2, 1:3:6 ( Using 40 Mm Gradedstone Aggregate ) In Plinth Protections, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 33 M & L For Treating The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface ( Area Of The Sub Structure In Contact With Backfill To Be Measured ) Complete All As Specified And Directed. 34 M&L Treating Thesoil Under Plinth Protection At The Rate Of 5.0 Ltr Of Emulsion Per Sqm Of Surface Area Complete All As Specified And Directed. 35 M&L Treating Thesoil Along With External Perimeter Of Building At The Rate Of 2.25. Ltr Of Emulsion Per Mtr Of The Perimeter Walls Complete All As Specified And Directed. 36 M & L For Treating The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Complete All As Specified And As Directed. 37 S & F Of 1Mm Thicksteel Rolling Shutters, Withball Bearing, As Specified Including Top Cover, Anchoring Rod, Hasp And Staple And One Shop Coat Of Primer; Erected In Position As Indicated, Complete Push Pull Or Manual Type Complete All As Specified And Directed. 38 M & L Preparation Of New Or Previously Untreated Steel Surfaces Of Any Description, Exceeding 10 Cm Width Or Girth, Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Zinc Primer Complete All As Specified And As Directed. 39 S & Faluminium Anodised Powder Coating ( Minimum Thickness Of Powder Coating 50 Micron ) Frame For Doors , Windows Etc With One Or More Rebates Including Necessary Joining Cleats ( Minimum Thickness Of Powder Coating 50 Micron ) Complete All As Specified And Directed 40 S & Fpowder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge 41 S & F 4.00 Mm Thick Sheet Glass, Ordinary Quality, In Squares Notexc 0.5 Sq.M Each Panel Complete All As Specified And Directed. 42 S & F Anodised Aluminium Grill ( Anodised Transparent Or Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15 ) Of Approved Design / Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass / Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineerin-Charge 43 M&L For 10 Mm Thick Cement Screed In Cement Mortar 1:4 With Water Proofing Compound At The Rate Of 2% By Weight Of Cement To Have A Smooth Surface For Laying Of Water Proofing Membrane And Brushing Neat Cement Slurry With 3.00Kg Of Cement Per Sqm Complete All As Specified And As Directed.Note : Wpc Will Be Measured And Paid Seperately 44 M & L For Preparation Of Surfaces And Applying Bituminous Primer @ 0.4 Liter / Sqm Complete All As Specified And Directed. 45 M&L For App Based Polymeric Membrane Minimum Weighing 3 Kg / Sqm And Minimum 3Mm Thick Reinforced With Polyster Non Wove Fabric ( Wt Not Less Than 150 Gms / Sqm ) Over A Coat Of Hot Blown Bitumen 85 / 25 Grade @ 1.20 Kg / Sqm Over Primed Surfaces By Forced Application Complete In Roof Surfaces And On Verticle Surfaces And Applying A Coat Of Solar Reflective Bituminous Aluminium Paint, Complete All As Specified. 46 Supply Only Integral Water Proofing Compound Complete All As Specified And Directed. 47 S & F Offramed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framedbalusters; Walk Ways; Railings; Framework Of Water Tanksand Similar Work Confirming To Fe.290.Gde-E-165 Complete All As Specified 48 Schedule A Part-Ii [ E / M Works ] 49 M&L For Point Wiring With 1.5 Sqmm ( Nominal Area ) Unsheathed Multi-Stranded Copper Conductor Pvc Insulated Cable 1100 Volts Grade Single Corefrlsdrawn Into And Including Non-Metallic Rigid Pvc Conduit Of 20 Mm Dia, Concealed Frlswiring, Along With 1.5 Sqmm Unsheathed Multi Stranded Copper Conductor Cable Pvc Insulated 1100 Volts Grade As Earth Continuity Conductor Connected To Common Earth Dolly Fixed To Wall / Ceiling Roofexcluding Modular Metal Flush Box And White Cover Plate With Frame The Switches, Sockets, Fan Regulator Etc As Required Suitable For Modular Type Fitting / Fixture Etc Witch Shall Be Measured And Paid Separately All As Specified And Directed For :- 50 ( A ) One Light Point Or One Fan Point Controlled By One Switch With Cables 1.5 Sq.Mm Size 51 ( B ) One 3 Pin Socket Outlet 5 Amps On The Same Board With Other Switches, With Cables 1.5 Sqmm Size 52 ( C ) One 3 Pin Socket Outlet 15 Amps, Independent, With Cables 4 Sq Mm Size 53 M&L Switch Modular10 Amps One Way Flush Type 1 Module Complete All As Specified And Directed. 54 M&L Modular Switch 1 Way 16A, 1 Module Complete All As Specified And Directed. 55 S & F Modular Fan Regulator, 120W Step Type 2 Module Complete All As Specified And Directed. 56 S & F Socket Modular 2 / 3 Pin 6 Amps Flush Type 2 Module Complete All As Specified And Directed. 57 S & F Socket Modular 2 / 3 Pin 6A / 16A Flush Type 2 Module Complete All As Specified And Directed. 58 S&F Modular Metal Flush Box 1 / 2 Module Complete All As Specified And Directed. 59 S&F Of Modular Metal Flush Box 6 / 8 Module Complete All As Specified And Directed. 60 S & F Modular White Cover Plate With Frame 1 Module Complete All As Specified And Directed. 61 S & F Modular White Cover Plate With Frame 8 Module Complete All As Specified And Directed. 62 Material And Labour For Sub Main Wiring ( Surface / Recessed Pvc Conduit ) Complete With Two Single Core 4 Sqmm Frls Pvc Insulated Unsheathed Stranded Copper Conductor Cable Drawn Through In And Including 25 Mm Dia Rigid Non-Metallic Pvc Conduit Heavy Grade And Conduit Accessories Including One Single Core 4 Sqmm Frls Pvc Insulated Unsheathed Stranded Copper Earth Cable Connected To Common Earth Dolly Complete And Including Making Good The Disturbed Surface All As Specified And Directed.Note: 3 Run Of 4 Sqmm & One Run Of Pvc Conduit Shall Be Measuredas Single Unit 63 S & F Led Light Fitting 4Feet, 1X20w, A Trendy Wall Mounted Battern, With Extrunded Aluminium Housing, With Integrated Led Driver, Etc. Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size Complete All As Specified And Directed.Make C&S Electricor Crompton, Cat Part Nolttb4f20wled / W 64 Supply And Fixing Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Complete All As Specified And Directed. 65 Supply And Fixing Ceiling Fans Complete With Blades, Down Rods, Electronic Regulator And Accessories, 230 V, 1200 Mm Sweep. Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current Motor ( Bldc ) Complete All As Specified And Directed. 66 S&F Ceiling Rose3 Terminals Pvc / Polycarbonate, Isolated Body Complete All As Specified And As Directed. 67 S&F Mcb Db Spn 8 Way Complete In Ss Enclosure Double Door Type With 200 Amps Rated Busbar Complete All As Specified And Directed. 68 Supply And Fixing Amp Rating 240V, 10Ka C Curve Miniature Circuit Breaker ( Mcb ) Of Following Poles And Current Carrying Capacity In The Mcb Db Complete With Connection Testing For The Following:- 69 ( I ) Sp 6 To 32 Amp 70 ( Ii ) Spn 32 Amp 71 M&L For Test Point Terminal Block Made Of Gun Metal Or Phosphorus Bronze Size 75X75x25mm Drilled And Screwed Including 3 Nos. 8Mm Dia 25Mm Long Hex. Head Screw Complete All As Specified And Directed. 72 M / L For Providing Earthing Complete Withcopperplate Size 600 Mm X 600 Mm X3.15Mm Thick Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level , Alternate Layers Of Charcoal ) & Common Salt Crystal Andconnected To Copper Earth Strip 20X3mm By Means Of Bolts, Nuts, Check Nuts & Washers Of Copper And Connecting To Earth Dolly All As Shown In Electrical Plateno. 3Of Ssr Part I Of 2009 & Testing Complete Including 40Mm Dialight Grade Gi Pipe Upto 7.5Mtr Long, Excavation In Any Type Of Strata, Pcc ( 1:3:6 ) Type C1 Earthing Chamber, Pre Cast Slab 50 Mm Thick In Cement Concrete ( 1: 2 : 4 ) Type B 1 ( Reinforced With Welded Steel Wire Fabric ( Xpm ) Weight Not Less Than 4 Kg / Sqm With Frame, Test Box , Including 20 Mm Bore Water Pipe Medium Gradegi Tubing Includinggi Funnel , Wire Mesh Etc. ( Note :- Earth Continuity Conductor And Gi Protection Pipe Beyond 7.5M Shall Be Measured And Paid Under The Respective Items ) .All As Directed By Engineer- In Charge. 73 Excavation In Trenches Not Exc 1.5 Mtr Wide And N. Exc 1.5 M Depth For Foundations Or Laying Under Ground Cable, Pipes Etc. And Getting Out In Soft / Loose Soil Etc.Complete All As Specified And Directed By Engr-In-Charge. 74 Supply And Spread Clean Dry River Sand In Trenches Including Levelling, Punning For Cushioning Of Cables Complete All As Specified And Directed By Engineer In Charge ( Note :- 1. Punned Thickness Only Will Be Measured2. Riddled Earth May Be Used In Case Of Non Availability Of River Sand Subject To Price Adjustment In Terms Of Condition 62 Of Iafw 2249. ) With Approval Of Accepting Officer. 75 Supply And Laying Reinforced Precast Concrete Cable Cover, Class Lv, Type 1, Flat Size 250Mm X 150Mm X 40Mm Complete All As Specified And Directed. 76 Supplyand Laid In Trenches Gipipe Light Grade80mm Dia As For Roadcrossing Of Cable Complete All As Specified And Directed. 77 Supplyand Laid In Trenches Gipipe Light Grade100mm Dia As For Roadcrossing Of Cable Complete All As Specified And Directed. 78 M & L Danger Notice Plate 1.6Mm Thick Mild Steel Sheet, Vitreous Enamelled White, With Letters, Figures And Conventional Skull And Bones In Signal Red Colour And Fixed With Ms Clamps, Bolts And Nuts Of Approved Size For Lt 20 X 15Cm Size Complete All As Specified And Directed. 79 Supply And Fix Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Straight Through Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3.5 Core Xlpe Armoured Aluminium Conductor Cable Of Size 120 To 185 Sq Mm Complete All As Specified And Directed. 80 All As Per Item No 74 Above But 240 Sqmm To 300 Sqmm Complete All As Specified And Directed. 81 Supply, Fabricate, Install, Testing And Commissioning Of Self Supported Totally Enclosed Floor Mounted On Base Channel Size 75 X 75 Mm And Thickness Not Less Than 5Mm Indoor Type Lt Fabricated From Cpri Certificate Panel Builder Factory And Fabricated Made Out Of Crca Sheet Of Thickness Not Less Than 2Mm Dust And Vermin Proof, Hinged, Smoothly Openable Front And Rear Door With Neoprene Polchloropene Rubber Gasket Epoxy Powder Coated Including Danger Plate.Earth Strip ( 32 X 6 ) Connecting Provision - 02 Nos Including Ventilation Louvers Bottom Detachable Gland Plate Complete With Suitable Size Zinc Chromium Plated Nuts, Bolts And Washer Etc, Complete Panel Board Suitable For 3 Phase 4 Wire 415 Volts 50 Hz Including The Following Items And Connecting All Out Going Feeder Cables Using New Suitable Feeder Details Size Logs And Connecting With Earth Strip, Aluminium Bus Bar Complete Including Neccessary.Complete All As Directed And Specified By Engineer -In- Charge. 82 Item No 76 Cont......Incoming:- ( A ) 630 A 4 Pole 50 Ka Microprocessor Mdo Acb Transformer- I ( B ) 630 A 4 Pole 50 Ka Microprocessor Mdo Acb Transformer-Ii ( C ) Buscoupler 630 A 4 Pole 50 Ka Thermal Magnetic Mdo Acb ( D ) 1000 A Aluminium Bus Bar ( E ) Mfm Meter - 02 Nos, R / Y / B Indicating Lamp Etc. Outgoings:- ( A ) 400 A 4P 50 Ka Adjustable Thermal & Fixed Mccb With Handle & Spreader Link - 02 Nos. ( B ) 250 A 4P 36 Ka Adjustable Thermal & Fixed Mccb With Handle & Spreader Link - 08 Nos. ( C ) 160 A 4P 36 Ka Adjustable Thermal & Fixed Mccb With Handle & Spreader Link - 06 Nos. 83 Supply & Fixing Of 630 A 4P 36 Ka Mccb Thermal Magnetic Mccb Handle & Spreader Link In The Existing Old Panel And Connecting The Busbar For The Same, Providing New Door For The Mccb Compartments Complete All As Specified And Directed. 84 Supply And Lay Cable Lt , 1100 Volts Grade Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Cross Sectional Area ( Connected Accessories Like Glad, Lugs Etc ) Of The Following Sizes:- 85 ( A ) 3.5 Core 400 Sq Mm 86 ( B ) 3.5 Core 240 Sq Mm 87 ( C ) 3.5 Core 185 Sqmm 88 ( D ) 3.5 Core 150 Sqmm 89 ( E ) 3.5 Core 120 Sqmm 90 M&L For Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area 3.5 Core 25 Sq. Mm Complete All As Specified And Directed. 91 M&L For Cable Route Indicator Ci Disc Of Size 100Mm Diax3mm Thick Marked As Mes Lt Cable Or Mes Ht Cable Including Angle Iron ( Height 600Mm ) Embedded In Pcc Block Of Size 60 X 60 X 30Cm ( L X W X H ) In Pcc 1:3:6 Type C1 Using 20Mm Graded Stone Aggregate Including Painting Of Exposed Surfaces With Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primercomplete All As Directed By Engineer - In - Charge. 92 Supplying And Laying Synthetic Rubber Insulated Mats 2 Mm Thick For Voltage Upto 3.3 Kv For Electrical Purpose As Per Is 15652-2006, ( Superseding Is 5424 ) Suitable For Electrical Shock Safety Of Sizes 2M X 1M Complete All As Specified And Directed. 93 Supply Electric Rubber Hand Gloves 11 Kv Complete All As Specified And Directed. 94 Signature Of Contractor