Comprehensive Maint / Petty Repair Of Internal Electrical Services At Cod Inside Under Ge ( I ) Kanpur. 1 Attending Complaints Fo Checking And Replaceing The Existing Defective Electrical Items For Continuous Electric Supply Including Carrying Out Minor Repair As Required To Make The Item Functional And Replacing Fuse, Small Pieces Of Copper Wire, Copper Cable As Of Suitable Size At Site, Insulation Tape Roll Etc. Attending Minor Repair ( S ) Such As Testing, Connectins, Fittings, Nut, Bolts, Screws Etc Toemergent Complaints I.E No Light, Earth Leakage, Short Circuit, Neutral Break In Mains / Sub Mains / Internal Circuits Of Existing Electical System Of Main Building / Block And Making Continuous Electric Supply Including Carrying Out Minor Repairs Etc.. Required To Make The System In Order / *Functional With Insualtion Tape Roll, Copper Thimbles, Glands, Earthing Wire As Required At Site And Complete All As Specified And Directed . Notes :- This Item Is Applicable Only Where No Store Is Required. 1. The Site For Attending Complaints At Cod Inside And As Directed By Engr-In-Charge.Contractor Shall Provide Minimum One Tradesmen ( Electrician ) And Helper For Each Site To Attend The Complaint In All Working Days Between 0830 Hrs To 1700 Hrs Including Holiday And Sunday. 2. Contractor Shall Ensure The Security Passess For His Staff, To Be Obtained From Concern Authority For Attending Complaints. 3.The Contractor Will Ensure That Theelecticians With Necessary Tools Bag Shall Always Remain Present At Complaint Cell To Attend The Complaints.4. A Recovery Of Rs 500 / - For Not Attending The Complaint Upto 04 Hours And After 04 Hours Rs 1000 / - Shall Be Recovered From The Contractor Due5. All The Complaint Slip, Register & Other Connected Document Will Be Provided By The Contractor Without Any Extra Cost.6.Proper Record ( Date Wise ) Of Complaints Received & Rectified By The Contractor And The Same May Be Asked For Verification At The Time Of Payment Of Each Rar / Bill.7. The Above Tradesmen Shall Not Be Utilize For The Complaints Where Material Is Required And These Complaint Shall Be Measured And Paid Seperately As S&F Here In After. 2 Supply And Fix In Replacement Cable Pvc Insulated Unsheathed With Flexible Multistranded Copper Conductor Of Size 0.75 Sqmm. Complete All As Specified And Directed. Make: Havells / Polycab / Plaza 3 All As Per Item No 2 Above But Size 1.5 Sqmm And.Complete All As Specified And Directed. Make: Havells / Polycab / Anchor 4 All As Per Item No 2 Above But Size 2.5 Sqmm And Complete All As Specified And Directed. Make: Havells / Polycab / Anchor 5 All As Per Item No 2 Above But Size 4 Sqmm. And Complete All As Specified And Directed. Make: Havells / Polycab / Anchor 6 All As Per Item No 2 Above But Size 6 Sqmm And Complete All As Specified And Directed.Make: Havells / Polycab / Anchor 7 All As Per Item No 2 Above But Size 10 Sqmm And Complete All As Specified And Directed. Make: Havells / Polycab / Anchor 8 M&L In Repair For Switch Piano Flush Button Single Pole One Way 5 Amps 240 Volts And Complete All As Specified And Directed. Make: Ssk / Anchor / Havells 9 M&L In Repair Forswitch Piano Flush Button Single Pole One Way 15 Amps 230 Volts And Complete All As Specified And Directed. Make: Ssk / Anchor / Havells 10 M&L In Repair For Socket 5 Amps 5 Pin Flush Type, 230 Volts And Complete All As Specified And Directed. Make: Ssk / Anchor / Havells 11 M&L In Repair For Socket Out Let, 6 Pin 5 And 15 Amps Multi Purpose 2 In 01 Flush Type, 230 Volts And Complete All As Specified And Directed. Make: Ssk / Anchor / Havells 12 M&L In Repair For Bell Push Flush Button Single Pole One Way 5 Amps 240 Volts And Complete All As Specified And Directed.Make: Ssk / Anchor / Havells 13 M&L In Repair For Electricbellheavy Dutyding Dong / Buzzer Type Ac 230 Volts Single Pole And Complete All As Specified And Directed. Make: Ssk / Anchor / Havells 14 M&L In Repair For Switch Modular Type Single Pole One Way 1 Module 6 Amps 240 Volts And Complete All As Specified And Directed. Make: Anchor / Havells ( Crabtree ) / Indoasian 15 M&L In Repair For Switch Modular Type One Way 1 Module 16 Amps 230 Volts And Complete All As Specified And Directed. Make: Anchor / Havells ( Crabtree ) / Indoasian 16 M&L In Repair For Socket 6 Amps Modular Type 2 / 3 Pin Combined 2 Module , 230 Volts As Per Sample And Complete All As Specified And Directed. Make: Anchor / Havells ( Crabtree ) / Indoasian 17 M&L In Repair For Socket Modular Type , 2 / 3 Pin, 6 And 16 Amps Combined 2 Module, 230 Volts.As Per Sample.And Complete All As Specified And Directed. Make: Anchor / Havells ( Crabtree ) / Indoasian 18 M&L In Repair Formodular White Cover Plate With Frame 2 / 3 Module A As Per Sample And Complete All As Specified And Directed. Make: Anchor / Havells ( Crabtree ) / Indoasian 19 M&L In Repair For Modular White Cover Plate With Frame 4 Module All As Specified And Directed As Per Sample. Make: Anchor / Havells ( Crabtree ) / Indoasian 20 M&L In Repair For Modular White Cover Plate With Frame 6 Module All As Specified And Directed As Per Sample. Make: Anchor / Havells ( Crabtree ) / Indoasian 21 M&L In Repair For Modular White Cover Plate With Frame 8 Module All As Specified And Directed As Per Sample. Make: Anchor / Havells ( Crabtree ) / Indoasian 22 M&L In Repair Formodular White Cover Plate With Frame 12 Module All As Specified And Directed.As Per Sample. Make: Anchor / Havells ( Crabtree ) / Indoasian 23 M&L In Repair For Ceiling Rose Surface Bakelite 3 Terminals And Complete All As Specified And Directed. Make: Ssk / Anchor / Havells 24 M&L In Repair Forlamp Holder Insulated Body With Back Plate For Dome Batten Fittings And Complete All As Specified And Directed.Make: Ssk / Anchor / Havells 25 M&L In Repair Forfan Regulator Electronic, Step Type Hum Free Suitable To Control Speed Of Fan From 0 To 100% And Connecting Electrically And Complete All As Specified And Directed. Make: Ssk / Anchor / Havells 26 M&L In Repair Formodular Regulator As Per Sample And Complete All As Specified And Directed. Make: Anchor / Havells ( Crabtree ) / Indoasian 27 Supply And Fixing In Replacement Plug Top 3 Pin 16 Amps Ac 240 Voltsand Complete All As Specified And Directed. Make: Ssk / Anchor / Havells 28 Supply And Fixing In Replacement Plug Top 3 Pin 6 Amps Ac 240 Voltsand Complete All As Specified And Directed. Make: Ssk / Anchor / Havells 29 Supply & Fix In Replacement Hylemsheet Cover 3 Mm Thick Of Size 7X4 All As Required At Site Including Drilling Holes For Fixing Screws And Providing 4 Nos Screws With Washers For Fixing The Sheet To Sunken Box / Wooden Box And Complete All As Specified And Directed . 30 All As Per Item No-29 Above But Of Size 8X10 And Complete All As Specified And Directed . 31 All As Per Item No-29 Above But Of Size 11X9 And Complete All As Specified And Directed . 32 All As Per Item No-29 Above But Of Size 13X11And Complete All As Specified And Directed . 33 S&F In Repair Sunken Box Size7X4 And Making Good Disturbed Surface To Match With The Existing Surface Ofwallby Applying Putty And Applying Colour / White Wash Finish And Complete All As Specified And Directed. 34 S&F In Repair Sunken Box Size 8X10 And Making Good Disturbed Surface To Match With The Existing Surface Ofwallby Applying Putty And Applying Colour / White Wash Finish Complete All As Specified And Directed. 35 S&F In Repair Led Alumimium Housing Batten Luminaire Surface Mounted, 4 Feet System Wattage Of 20 / 22 Watts With Lifetime Ofnot Less Than 50000 Burning Hours With 70% Of Its Initial Lumen Maintained And Including Connecting Up With Pvc Sheathed 1.5 Sqmm 3 Core Copper Conductor Flexible Wire From Ceiling Rose To Fitting Fixe Complete All As Pecified And Directed By Engr-In-Charge. Note:- All The Above Mentioned Specifications Will Be Verifed Through Lm 79 And Lm 80 Report Of Nabl Accredited Lab Before Supply Of Led Fixtures And Complete All As Specified And Directed. Make:Havells / Phillips / Orient 36 S&F In Repair Led Alumimium Housing With Inbuilt Smart Motion Sensor Based Auto Dimmable Batten Luminaire Surface Mounted, 4 Feet System Wattage Of 20 Wattsand Including Connecting Up With Pvc Sheathed 1.5 Sqmm 3 Core Copper Conductor Flexible Wire From Ceiling Rose To Fitting Fixe Complete All As Pecified And Directed By Engr-In-Charge Make: Shakti Fixtures Pvt Ltd / Havells / Phillips / Orient / 37 S&F In Replacement Gate Light Fitting Led Type 25 W With Cct Not Less Than 5700K / 3000K / 4000K , And Ip 65 Protection , 230Vrecessed Mounting Mirror Opticluminare Complete With All Accessories Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable With Suitable Size, Make :Havells / Phillip / Indoasian Complete Includingwire And Making Connection Complete With Pole All As Specified And Directed By Engr-In-Charge. 38 S & F In Replacement Of Led Post Top Globestarmade Up Of Unbreakable Polycarcarbonate Suitable For Mounting On Gate With Led Bulb 12 Wwith Proper Arrangements And Making Electrical Connection And Complete All As Specified And Directed. Make : Wipro / Bajaj / Havells 39 Supply And Fix Led Alumimium Batten Luminaire Surface Mounted, 2 Feet System Wattage Of 10 Watts With Lifetime Ofnot Less Than 50000 Burning Hours With 70% Of Its Initial Lumen Maintained And Including Connecting Up With Pvc Sheathed 1.5 Sqmm 3 Core Copper Conductor Flexible Wire From Ceiling Rose To Fitting Fixe Complete All As Pecified And Directed By Engr-In-Charge.Make:Havells / Phillips / Orient 40 S&F In Replacement Of Led Light Fitting Recess Mounted 36 Watt, 1 X 4 With All Accessories Suitable For Amstrong / Grid / Pop Ceiling Complete With Integrated Electronic Driver And Making Electrical Connection With Making Electrical Connection With Three Core Copper Wire To Ceiling Rose Properly And Complete All As Specified And Directed.Make:Havells / Phillips / Wipro 41 S&F In Replacement Of Led Light Fitting Recess Mounted 31 / 32 Watt, 2 X 2 With All Accessories Suitable For Amstrong / Grid / Pop Ceiling Complete With Integrated Electronic Driver And Making Making Electrical Connection With Making Electrical Connection With Three Core Copper Wire To Ceiling Rose Properly And Complete All As Specified And Directed.Make:Havells / Phillips / Wipro 42 S&F In Replacement Of Of Highway Discreet Led , Pdc Housing & Internal Led Driver, Pc Lens To Provide Better Uniform Distribution, Ip-65 Protection Siutable For 60 / 80 Watts With All Assesoriesi.E. Clamp , Nut Bolts Washer And Connecting Electrically With 3 Core Copper Flexible Wire Of Size 1.5 Sqmm From Ceiling Rose To Fitting And Complete All As Specified And Directed. Make:Havells / Phillips / Wipro / Bajaj 43 S&F In Replacement Of Of Highway Discreet Led , Pdc Housing & Internal Led Driver, Pc Lens To Provide Better Uniform Distribution, Ip-65 Protection Siutable For 120 / 140 Watts With All Assesoriesi.E. Clamp , Nut Bolts Washer And Connecting Electrically With 3 Core Copper Flexible Wire Of Size 2.5 Sqmm From Ceiling Rose To Fitting All As Sfd And Directed. Make:Havells / Phillips / Wipro / Bajaj 44 Supply And Fixing In Repair 10W Surface Mounted Ip65 Bulkhead With System Efficiency Of 100Lm / Watt Led Bulk Head Shall Be Made Up Of Die Cast Aluminium Housing For Better Heat Decapitation.P.F>.95With Thd <10%, Surge Protection 4Kv Input Voltage Rane 150Vto 270V Including Connecting Electricaly To Ceiling Rose Using Cord Flexible 3 Core Pvc Insulated Over All Sheathed With Flexible Copper Conductor Of Size 0.75 Sqmm And Complete All As Specified And Directed. Make:Havells / Phillips / Orient 45 M&L In Repairfor Sheet Metal Enclosure Mcb Distribution Board Single Pole And Neutral With A Two Pin And Earth Plug And Socket 25 Amps 240 Volts, Complete With One Single Pole Mcb Of 25 Amps Earthing And Complete All As Specified And Directed . 46 M&L In Repairfor Rccb , Double Pole, Single Phase240 Volts , Rated Current 25 Amp, Sensitivity 30 Ma, 10 Ka Complete Using Thimbles Of Required Size Complete Suitable For Fitted In Box.Make: Legrand / Havells / C&S / Indoasian 47 Supply And Fix In Repair Sheet Metal Enclosure Mcb Distribution Board, Double Door With Ip-43 Protection With Acrylic Cover Single Phase 240 Volts 4 Way, Including Suitable Size Copper Bus Bar And Neutral Link Fixed Flush In Wall Including Chases Wall For Fixing Db And Making Good Distributed Wall Surfaces To Match With Existing Specification And Complete All As Specified And Directed.Make:Legrand / Havells / Indoasian / L&T 48 All As Per Srl Item No 47 Above Butfor 8 Way And Complete All As Specified And Directed . 49 M&L In Repair For Mcb Single Pole 240 Volts 6 To 30 Amps, With Rupturing Capacity 10 Ka Using Thimbles Of Required Size And Complete All As Specified And Directed. 50 M&L In Repair Mcb Single Pole & Neutral 240 Volts 40 Amps, With Rupturing Capacity 10 Ka Using Thimbles Of Required Size And Complete All As Specified And Directed. 51 All As Per Item No 50 Above But Of Size 63 Amps And Complete All As Specified And Directed. 52 Supply And Fix In Replacement Of Led Wall Security Light 25 Watt Ip 66 Energy Saving & Environmental Friendly Long Lifepressure Die-Cast Aluminium Housing For Better Heat Decapitation Efficiency Not Less Than Of 100 Lm / Wat , P.F>.95With Thd <10%, Surge Protection 4Kv Input Voltage Rane 150Vto 270Vincl Suitable Size Service Bracket Fixed With Clamps, Nut, Bolt And Washer And Electric Connection With 1.5 Sqmm Multistranded Twin Core Alum Cable Pvc Insulated And Complete All As Specified And Directed. Make : Havells / Phillips / Orient 53 S & F In Repair Distribution Board Iron Clad, Double Door With Ip-43 , Ik-09 Protection Suitablefor Mccb As Incommer And Mcb As Outgoing 415 Volts 3 Phase 50 C / S 4 Way, Complete With Appropriate Size Copper Bus Bar And Neutral Link, Complete With One Mccb 3 Pole 415 Volts 63 Amps Rating With Rupturing Cap 16 Ka Of The Same Make As Of Distribution Board & With Mcbs Of Required Size Making Connection With Thimbles & Including Cutting Chases To Wall For Fixing Db And Making Good The Disturbed Wall Surface And Complete All As Specified And Directed. 54 S & F In Repair Switch Socket Combination 2 In 1, 3 Pin, 5Amp Flush Type Universal With Complete Box All As Specifid And Directed. Make: Ssk / Anchor / Havells 55 S & F In Repair Switch Socket Combination 2 In 1, 3 Pin, 15 Amp Flush Type Universal With Complete Box All As Specifid And Directed Make: Ssk / Anchor / Havells 56 S & F In Repair Switch Socket Combination 2In 1, 5 A Flush Types All As Specifid And Directed Make: Ssk / Anchor / Havells 57 S & F In Repair Switch Socket Combination 2In 1, 15 A Flush Types All As Specifid And Directed Make: Ssk / Anchor / Havells 58 S & F In Repair Led Bulb Of 09 Watt Cool Day Light Eco Friendly Energy Efficient And Complete All As Specified And Directed. Havells / Phillips / Orient 59 S & F In Repairsolar Led Pathway Lights Bollard Type Waterproof Outdoor Lighting Path Light Ip65 , For Garden ( Warm White / Coolday Whitenot Less Than 15 W And Hight Not Less Tha 80 Cm With High Efficient Leds Including Not Less Than 8W / 5V Monocrystalline Solar Panel & High Battery Backup Suitable For 10 Hrs Working Timeand The Light , Automatically Turns On The Light At Night And Turns Off In The Morning ( Dusk To Dawn ) , Need To Make The Switch On & Off Which Makes This Solar Decorative With Suitable Pcc Foundation And Making All Electric Connection All As Specified And Directed. Make : Axxon Tech / As Per Approved By Ge 60 Taking Down Carefully Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete, Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting, Bell, Bell Push Etc And Making Good Disturbed Surfaces Of Walls, Floor To Match With Existing Specification Complete And All As Specified. 61 Point Wiring For One Light Point / Fan / Bell Point Controlled By One Switch With 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Single Core Multi Strand Flexible Cable Frls With Proper Color Coding And 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Single Core Multistranded Cable ( Green Color ) As Earth Lead In And Including Concealed Non Metalic Rigid Pvc Conduit Medium Grade Size 25Mm Dia With All Fittings ( Isi Marked ) Controlled By One Switch Including Ci / Ms Sunk Box Of Required Size & As Directed & 3 Mm Thick Plastic Laminated Sheet, Including Cutting Chases To Wall Making Good The Disturbed Surfaces To Match With Theexisting Specification And Complete All As Specified And Directed. Make Of Cable : Havells / Polycab / Anchor 62 All As Per Srl Item No-61 Here In Above But Upto Ceiling Height And On Surface At Ceiling And Complete All As Specified And Directed. 63 All As Per Srl Item No-61 Here In Above But In Existing Conduit And Complete All As Specified And Directed. 64 All As Per Srl Item No-61 Here In Above But For One 3 Pin 15 Amps Socket Outlet Independentwith 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Single Core Multi Strand Flexible Cable And 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Single Core Cable ( Green Color ) As Earth Lead In And Incl Conduit And Complete All As Specified And Directed. 65 All As Per Srl Item No-61 Here In Above But For One 3 Pin 15 Amps Socket Outlet Independentwith 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Single Core Multi Strand Flexible Cable And 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Single Core Cable ( Green Color ) As Earth Lead In Existing Conduit And Complete All As Specified And Directed. 66 All As Per Srl Item No-61 Here In Above But For One 3 Pin 5A Socket Outlet Independent Controlled By One Switch And Complete All As Specified And Directed. 67 All As Per Srl Item No-61 Here In Above But For One 3 Pin 5A Socket Outlet Independent Controlled By One Switch In Existing Conduit And Complete All As Specified And Directed. 68 All As Per Srl Item No-61 Here In Above But For One 5A Socket Outlet On The Same Board Controlled By One Switch And Complete All As Specified And Directed. 69 All As Per Srl Item No-61 Here In Above But For One 5A Socket Outlet On The Same Boardcontrolled By One Switch In Existing Conduit And Complete All As Specified And Directed. 70 All As Per Srl Item No-61 Here In Above But For One Light Point Controlled By 2 Nos Two Way Switches And Complete All As Specified And Directed. 71 All As Per Srl Item No-61 Here In Above But For One Light Point Controlled By 2 Nos Two Way Switches In Existing Conduit And Complete All As Specified And Directed. 72 All As Per Srl Item No-61 Here In Above But For One Light / Fan / Bell Point Including Pressed Steel Terminal Modular Boxes Of Appropriate Size And Top Cover With Suitable Size Of Modular Plate With All Accessories And Complete All As Specified And Directed. 73 All As Per Srl Item No-61 Here In Above But For One Socket Outlet 5 Amps On Indipendent Board Including Pressed Steel Terminal Modular Boxes Of Appropriate Size And Top Cover With Suitable Size Of Modular Plate With All Accessories And Complete All As Specified And Directed. 74 All As Per Srl Item No-61 Here In Above But For One Socket Outlet 5 Amps On Same Board Including Pressed Steel Terminal Modular Boxes Of Appropriate Size And Top Cover With Suitable Size Of Modular Plate With All Accessories And Complete All As Specified And Directed. 75 All As Per Srl Item No-61 Here In Above But For One Light Point Controlled By Two, Two Way Switches Including Pressed Steel Terminal Modular Boxes Of Appropriate Size And Top Cover With Suitable Size Of Modular Plate With All Accessories And Complete All As Specified And Directed. 76 All As Per Srl Item No-61 Here In Above But For One 3 Pin 15 Amps Socket Outlet Independentwith 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Single Core Multi Strand Flexible Cable And 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Single Core Cable ( Green Color ) As Earth Lead In And Including Pressed Steel Terminal Modular Boxes Of Appropriate Size And Top Cover With Suitable Size Of Modular Plate With All Accessories And Complete All As Specified And Directed. 77 M&L In Replacement Forsubmain Wiring With Two Single Core Pvc Insulated Flexible Copper Conductor Multistranded Cable ( Frls ) Of Size 4 Sqmm With Proper Color Coding And One Single Core Pvc Insulated Flexible Copper Conductor Multistranded Cable Green Colour Of Size 4 Sqmm As Earth Lead In & Including Concealed Pvc Conduit Medium Grade 25Mm Dia Cutting Chases To Walls For Laying Conduit And Making Good The Disturbed Wall Surfaces To Match With Existing Specification And Complete All As Specified And Directed. Make Of Cable : Havells / Polycab / Anchor 78 All As Per Srl Item No-77 Here In Above But In Existing Concealed Conduit And Complete All As Specified And Directed. 79 All As Per Srl Item No-77 Here In Above But For Cable Of Size 6 Sqmm And One Single Core Pvc Insulated Flexible Copper Conductor Multistranded Cable Green Colour Of Size 6 Sqmm As Earth Lead In & Including Concealed Pvc Conduit And Complete All As Specified And Directed. 80 All As Per Srl Item No-77 Here In Above But For Cable Of Size 6 Sqmm And One Single Core Pvc Insulated Flexible Copper Conductor Multistranded Cable Green Colour Of Size 6 Sqmm In Existing Concealed Conduit With Earth Wire 4 Sqmm And Complete All As Specified And Directed. 81 All As Per Srl Item No-77 Here In Above But For Cable Of Size 10 Sqmm And One Single Core Pvc Insulated Flexible Copper Conductor Multistranded Cable Green Colour Of Size 6 Sqmm In & Including Concealed Pvc Conduit And Complete All As Specified And Directed. 82 Supply And Laying To Wall Or Poles Or Fixing Or Passing Through Pipe, 1100 Volts Grade Heavy Duty Cable With Pvc Insulated Aluminium Multistranded Conductor 6 Sq. Mm Nominal Cross Section Twin Core For Service Connectionsand Complete All As Specified And Directed. 83 All As Per Srl Item No 82But Cable Of Size 10 Sqmm 2 Core And Complete All As Specified And Directed. 84 All As Per Srl Item No 82But Cable Of Size 16 Sqmm 2 Core And Complete All As Specified And Directed. 85 M&L In Replacement Of Earthing Complete With Galvanised Cast Iron Earth Plate Electrode Of Size 600X600x6mm Thick As Earth Electrode With Top Edge Of The Earth Plate Not Less Than 1.5Mtr Below Ground Level Using Gi Wire 4Mm Dia As Earth Continuity Conductor Connected To Earth Plate By Means Of Gi Thimbles Nuts Bolts Washers All As Directed Including Providing Earth Wire Protection Pipe Gi Light Grade15mm Dia From Earth Plate To Main Switch Board / Panel, Watering Pipe 20Mm Dia With Wire Mesh And Funnel At Top, Earth Pit And Rcc Pit Cover In Pcc 1:3:6 Adequate Quantity Of Charcoal Dust And Salt All Around The Erth Plate, Earth Work In Any Type Of Soil Remaing Surplus Excavated Material All As Required At Site And Specified In Ep No 5 Of Ssr Part I 1991 Or Testing On Completion And Complete All As Specified And Directed.