Supply Of Consumable In Neuro Intervantion Lab In Mbs Hospital Kota ( Rate Contract Two Year ) , Group –A: Diagnostic And Accessories All The Consumable Items Must Be Approved / Being Used In Leading Govt. Hospitals In India Like Aiims, New Delhi, Pgi-Chandigarh, Sgpgi-Lucknow, Sms Jaipur Etc. , Long Introducer Sheath · Sizes4fr, 5Fr, 6Fr, 7Fr, 8Fr, &9 French And Above · Should Be Available In Length From 65- 90 Cm Long · 0.021 To 0.038-Inch Guide Wire Compatible · Kink Resistant , Introducer Sheath For Adult · Sizes 4Fr, 5Fr, 6Fr, 7Fr, 8Fr, &9 French And Above · Should Be 10-24Cm · 0.021 Or 0.038 Inch Guide Wire Compatible · Kink Resistant · With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion , Long Introducer Sheath 90 Cm Or Above ( Stainless Steel Braided ) : Should Be Available In 6Fr, 7Fr With 0.088 In – 0.091 Inch With Rounded Automatic Tip , Puncture Needle For Vascular Access In Adult ( 18G ) , Micro Puncture Needle For Vascular Access In Children- ( 20-22G ) , Head Hunter Catheter · In Various Standard Lengths And Curves · 035-038 Compatible · 100 Cm Long , Simmons / Sidewinder Catheter • In Various Standard Lengths And Curves • 035-038 Compatible • 100 Cm Long , Vertebral Catheter-In Various Standard Lengths And Curves , Distal Access Catheter For Co- Axial Systems • In Various Standard Lengths • 5F, 6F, 7Fr Size • 0.035” To .070”, .074 Inner Lumen. , Shepherd’S Hook Catheter In Various Standard Lengths And Curves , Pigtail Catheter 4 French / 5 French / 6 French / 7 French / 8French In Various Standard Lengths. , Cournard Catheter 4 French / 5 French / 6 French / 7 French / 8French In Various Standard Curves And Lengths. , Cobra Type Catheter • In Various Standard Lengths And Curves. • 4Fr, 5Fr, 6Fr Size , Hydrophilic Diagnostic Guide Wire – Type ( Regular Length, Regular Stiffness ) • Must Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Have Superelastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip • Should Be Between 120-150 Cm Long , Hydrophilic Diagnostic Guide Wire – Type ( Exchangelength, Extra Stiffness ) • Must Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Have Superelastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip • Should Be Between 180-260 Cm Long , Balloon Tipped Guiding Catheter Sizes6fr, 7 Fr, 8 Fr, 9Fr, 10 Fr , Inflation Device With Analog Display , Tuohy Borst Haemostatic Y-Connector , Tuohy Borsthaemostatic Y-Connector With Double Side Arm , Disposable Luer Lock Syringe • Should Be Compitable With Cuanoacrylate. • Should Be Available In 1 C.C / 2C.C / 3C.C / 5C.C / 10 C.C / 20 C.C / 50C.C , Picard Catheter • In Various Standard Lengths And Curves • 035-038 Compatible 100 Cm Long , Envoy Catheter • In Various Standard Lengths And Curves • 058-070 Compatible 100 Cm Long , Amplatz Catheter : • In Various Standard Lengths And Curves • 035-038 Compatible 100 Cm Long , Group –B:Carotid Angioplasty All The Consumable Items Must Be Approved / Being Used In Leading Govt. Hospitals In India Like Aiims, New Delhi, Pgi-Chandigarh, Sgpgi-Lucknow, Sms Jaipur Etc. , Guiding Catheter For Neuro Vascular Use • Should Have Atraumatic Soft Tip& Flexible Shaft • Should Be Available In Various Tip Shapes And Curves For Access To Different Parts Of The Neuro Vasculature • Should Have Outer Diameter Of 6Fr, 7 Fr, 8 Fr, 9Fr, 10 Fr Available • Should Have Inner Diameter Of 4.2Fr • Should Have Various Lengths From 90-110 Cm , Proximal Neuro-Protection Device For Embolic Protection ( Proximal Balloon Occlusion Technique ) , Distal Neuro-Protection Device For Embolic Protection ( Filter With Proximal Balloon Occlusion Technique ) , Distal Neuro-Protection Device For Embolic Protection ( Filter ) • Should Be On A .014” Wire • Should Be Made Of Polyurethane With Radio-Opaque Nitinol Loop • Should Be Suspended On The .014” Wire With A Suspension Arm • Should Not Occlude Flow While In Placement • Should Be Rapid Exchange Type • Should Be Compatible With A 6 F Guiding Catheter ( 0.066” Id ) • Should Allow Optimal Filtration In Vessels 3.5 – 5.5Mm Size , Carotid Angiopalsty Balloon Catheter ( Over The Wire / Rapid Exchange ) • Should Have Hydrophilic Coating • Should Be Available In Various Outer Diameters And Balloon Lengths And Various Shaft Lengths , Carotid Self Expendable Stents • Should Be 0.014” Compatible • Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) • Should Be Available In Various Diameters And Length Should Be On A Shaft Length Of 80-140 Or Above Length , Carotid Self Expendable Stents • Should Be 0.018” Compatible • Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) • Should Be Available In Various Diameters And Length • Should Be On A Shaft Length Of 80-140 Or Above Length , Carotid Self Expendable Stents • Should Be 0.035” Compatible • Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) • Should Be Available In Various Diameters And Length • Should Be On A Shaft Length Of 80-140 Or Above Length , Carotid Stents Balloon Expendable • Should Be 0.014” Compatible • Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) • Should Be Available In Various Diameters And Length • Should Be On A Shaft Length Of 80-140 Or Above Length , Carotid Stents Balloon Expendable • Should Be 0.018” Compatible • Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) • Should Be Available In Various Diameters And Length • Should Be On A Shaft Length Of 80-140 Or Above Length , Carotid Self Expendable Stents With Tapered Diameter • Should Be 0.014” Compatible • Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) • Should Be Available In Various Diameters And Length • Should Be On A Shaft Length Of 80-140 Or Above Length , Peripheral Balloon Expandable Stent – ( Otw / Rx ) • Should Be 0.014 / 0.018” Compatible • Should Over The Wire • Should Be Made Of Cobalt Chromium / Bare • Should Have Balloon Od Available In 4-7 Mm • Should Have Balloon / Stent Lengths Of 12-18 Mm • Should Have Shaft Lengths Of 80-150 Cm , Group–C:Aneurysms Coils& Adhesives All The Consumable Items Must Be Approved / Being Used In Leading Govt. Hospitals In India Like Aiims, New Delhi, Pgi-Chandigarh, Sgpgi-Lucknow, Sms Jaipur Etc. , Special Micro Guidewire With Torque Device For Use With Microcatheters ( Size: 0.007”- 0.014” ) , Special Micro Guidewire ( Exchange Length- 260- 300 Cms ) With Torque Device For Use With Microcatheters ( Size: 0.010”- 0.014’ ) , Electrolyte Detachable 3-D Type / Helical / 360 Coils For Intracranial Aneurysms Treatment- Bare Platinum Coils , Electrolyte Detachable 3-D Type / Helical / 360 Coils For Intracranial Aneurysms Treatment- Coated / Bioactive Platinum Coils , Thermo Mechanical Detachable 3-D Type / Helical / 360Coils For Intracranial Aneurysms Treatment- Non-Bioactive Platinum Coils , Thermo Mechanical Detachable 3-D Type / Helical / 360 Coils For Intracranial Aneurysms Treatment- Bare Platinum Coils , Mechanical Detachable 3-D Type / Helical / 360Coils For Intracranial Aneurysmstreatment- Bare Platinum Should Be Available From Various Sizes From 1.0 Mm – 4.0Mm Diameter , Machenical Detachable 3-D Type / Helical / 360 Coils For Intracranial Aneurysmstreatment- Coated Platinum Coils , Selective Infusion Microcatheter For Intracranial Aneurysm Treatment With 2 Tip Markers , Selective Infusion Microcatheter For Devploying Intracranial Device Should Be Compitable For Stents, Flow Diverters Or Stent Retrievers Of Various Sizes. , Power Supply Accessories And Connecting Cables For Detachable Coils , Detachable Balloon Catheter , Detachable Balloon Microcatheter For Detachable Balloons , Tissue Adhesive For Avms / Avfs / Davfs / Tumor-Embolization ( N-Butyl Cyanoacrylate ) , Poly Vinyl Alcohol ( Pva ) Particles For Pre-Operative Tumour Embolization , Ethyl Vinyl Alcohol Embolic Agent ( With Dmso ) For Avms / Avfs / Davfs / Tumor-Embolization , Lipidol Ultra Fluid , Group-D: Stents& Balloons For Cranial Use All The Consumable Items Must Be Approved / Being Used In Leading Govt. Hospitals In India Like Aiims, New Delhi, Pgi-Chandigarh, Sgpgi-Lucknow, Sms Jaipur Etc. , Double Lumen Balloon Angioplasty Catheter For Intra-Cranial Use , Open Cell Design Intra-Cranial Stents For Stent Assisted Coiling Of Aneurysms • Should Have Open Cell Design • Should Be Availble In Various Sizes & Diameter , Closed Cell Design Intra-Crenialstents For Stent Assisted Coiling Of Aneurysms • Should Be Compitable For Small / Large Vessel • Should Be Availble In Various Sizes & Diameter , Extra-Cranial Stent For Carotid & Vertebral Arteries & Dural Sinuses: Self Expandable & Closed Cell Design , Extra-Cranial Bare Metal Stent For Carotid & Vertebral Arteries & Osteal Lesions: Balloon Mounted , Self Expandable Intra-Cranial Stent For Treatment Of Atherosclerotic Stenotic Lesions Of Intracranial Vessels , Balloon Mounted Intra-Cranial Stent For Treatment Of Atherosclerotic Stenotic Lesions Of Intracrenial Vessels , Stent-Graft ( Covered Stent ) For Pseudo Aneurysm Or Fistula Treatment , Flow Diverter For Intracranial Aneurysm Treatment , Single Lumen Balloon Angioplasty Catheter For Intra-Cranial Use , Hybrid Cell Design Intra-Cranial Stents For Stent Assisted Coiling Of Aneurysms • Should Have Open Cell Design Should Be Availble In Various Sizes & Diameter , Group –E: Clot Retrieval Devices For Thrombectomy All The Consumable Items Must Be Approved / Being Used In Leading Govt. Hospitals In India Like Aiims, New Delhi, Pgi-Chandigarh, Sgpgi-Lucknow, Sms Jaipur Etc. , Revascularization Device For Mechanical Thrombectomy , Endo Vascular Snares For Retrieval Of Intravascular Foriegn Object , Thrombus Suction Catheters For Clot Retrieval From Carotid & Vertebrals , Infusion Catheters For Motorized Fragmentation And Suction For Clot Retrieval With Separator , Stent Retriever For Thrombectomy , Web Device Intra Saccular – Available In Assorted Sizes , Fully Visible Under Fluoroscopy Revascularization Device For Mechanical Thrombectomy , Group – F:Embolization / Avms All The Consumable Items Must Be Approved / Being Used In Leading Govt. Hospitals In India Like Aiims, New Delhi, Pgi-Chandigarh, Sgpgi-Lucknow, Sms Jaipur Etc. , Super Selective High Flow Infusion Catheters – For Cerebral / Spinal Avms ( Compitable With N-Butyl Cyanoacrylate ) , Super Selective High Flow Infusion Catheters – For Cerebral / Spinal Avms ( Compitable With Dmso ) , Super Selective High Flow Infusion Catheters – For Cerebral / Spinal Avms ( Compitable With Dmso ) With Detachable Tips , Super Selective High Flow Infusion Catheters – For Cerebral / Spinal Avms ( Compitable With Particulate Embolic Agents Such As Pva Particles )