| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground as post embedded in concrete, brick work, masonry work etc,complete all as specified and directed. |
| 2 | Dismantling of old unserviceble fencing wire mesh, including round bars any type, complete all as specified and directed. |
| 3 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance n exc 50m andmaking good surface in soft / loose of soil, complete all as specified and directed. |
| 4 | M&L for plain cement concrete, type B-2 1:2:4, (using 40 mm graded crushed stone aggregates)in foundation, filling and mass concrete as in post, complete all as specified and directed. |
| 5 | S&F for mild steel work as inposts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc. and similar work conforming to Fe-290 Gde E-165, embedding in concrete, complete all as specified and directed. Note :- (i) Size of angle shall be as per standard drgs.(ii) Earth work and concrete shall measured & paid for separately under respective items of this BOQ. |
| 6 | Fixing only chain link fencing including line wires, any mesh, size & type tostandards, rails, straining bolts, round bar etc including provision of binding wire, complete all as specified and directed.(Note: 10mm dia round bars and flat iron shall be measured and paid separately under respective items of this BOQ). |
| 7 | Supply only chain link MS galvansied fencing, not exc 4 kg per Sqm any size of type, complete all as specified and directed |
| 8 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality comfarming to Fe-410-W, grade E-250, as in columns complete all as specified and directed. |
| 9 | M&L for 12mm bolts and nuts (machine made) with hexagonal or square head at one end and screwed the other with washers of length n. exc 12 cm and n exc 30 cm after taking down of old nuts and bolts complete all as specified and directed. |
| 10 | S&F for galvanised, 2 strand, steel barbedwire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line of wire to be measured) after dismantling of old unserviceble barbed wire complete all as specified and directed. |
| 11 | S&F for concertina coil 600 mm dia, 56 loops, 2.5mm core wire heavy galvanised (wire-275 GSM & strip-200 GSM), tensile strength of wire 1400-1500 N/Sqmm, weight 14.63 Kg/coil, stretchable length 12M inlcuding securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc after dismantling of old concertina coil of any type complete all as specified and directed. |
| 12 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth andapplying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 13 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed. |
| 14 | M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed. |
| 15 | Description all as per srl item No. 14 above but except stone.NOTE: Old stone retrieved from demolition shall be used. |
| 16 | M&L for extra over stone walling of any type of stone for hammer dressing to face stones and dressing of face beds with maximum depression on facefrom straight edge held against the dressed surface n exc 40 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed. |
| 17 | M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in Cement Mortar 1:4, complete all as specified and directed. |
| 18 | M&L for brick work with sub class \"B\" bricks, old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 19 | Description all as per item No. 18 above but except BricksNOTE: Old brick retrieved from demolition shall be used. |
| 20 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 21 | M&L for rendering 15 mm thickon concrete / brick surface on wallin cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified and directed. |
| 22 | M&L for rendering 15 mm thickon concrete / brick surface on wallin cement mortar 1:4 on other thanfinished even and smooth without using extra cement,complete all as specified and directed. |
| 23 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of white cement primer, complete all as specified and directed. |
| 24 | Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed. |
| 25 | M&L for plain cement concrete, type E-2 1:5:10 (using 40 mm graded crushed stone aggregates)in foundation, filling, sub base and mass concrete as in post, complete all as specified and directed. |
| 26 | M&L forpre polished coloured chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick set, jointed in neat cement slurry in floor and pointed in white or coloured (apporved by GE) cement to match the shade of tiles laid over and including 15 mm thick screed bed in cement mortar 1:4after dismantling of old unserviceable tiles etc, complete all as specified and as directed. |
| 27 | M&L for 100mm thickplain cement concrete 1:4:8, typeD-2 (using 40mm graded crushed stone aggregates) as in sub base for tiling, complete all as specified and directed. |
| 28 | M&L for 100mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded stone aggregates as in hard standing and footpaths, finished the surface even and fair, complete all as specified and directed. |
| 29 | M&L forforming construction joints 30mm deep x 10mm wide filled with sealing, compound grade-\"A\" complete all as specified and directed. |
| 30 | M&L formachine pressed precast concrete interlocking paver block of any shape and size approved by Engineer-in-Charge , ISI marked (IS:15658-2006)60mm thick,M-25 grade (Heavy Traffic),in paths and hardstanding, with grey cement, laid tightly over & including 25mm thick dry sand cushion (compacted) andjoints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.(Note: 20% coloured interlocking paver block with colour pigmant and 80% greycement interlocking paver block with no pigment are used as directed by Engr-in-Charge). |
| 31 | M&L for PCC type B-1, 1:2:4 (using 20mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps, and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, coping, benching, hold fast, water troughs, bed block and the like including weathering, slightly rounded or chamfered angle and throating including necessary form work complete all as specified and directed |
| 32 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed. |
| 33 | M&L for plain cement concrete, type B-2 1:2:4, (using 40 mm graded crushed stone aggregates)as in surface channel and drains, complete all as specified and directed. |
| 34 | M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide,for rough finished surfaces of concrete, complete all as specified and directed. |
| 35 | M&L forcomplete removal of existing treatment on wall surface and applying two coats of cement base paintover a coat of chalk whiting including preparing surface, complete all as specified and directed. |
| 36 | M&L for preparation of old steel surface exc 10 cm width or girth and applying one coats of synthetic enamel paint, complete all as specified and as directed by Engr-in-Chagre. |