| 1 | Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges in large patches as in roof covering complete all as specified and directed.Note:- opening of existing wind tie where required for taking down of AC sheet is deemed to be included in the rate quoted . |
| 2 | Dismantling of timber fillets , rails, posts, rafters, purlin etc under 40 sqcmin section, in any positionin unframed work complete all as specified and directed. |
| 3 | Dismantling of timber scantling 40Sqcm and over in section in any position such as in rafter, purlins etc in unframed work complete all as specified and directed. |
| 4 | M&L for clean sawn 2nd class hard wood as in scantling any section sectional areafixed to timber/iron frame work complete all as specified and directed. |
| 5 | Cutting holes into or through brick wall built in cement lime mortar and walls of cement concreteof superficial area exc 150 sqcm but n exc 400 sqcm and making good in CM 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed. |
| 6 | S&F rolled mild steel section work as in main and cross beam, hip and jack rafters purlins where connected to common rafters and running rails fixed with angle cleats or other connecting plates,Wind tie and and similar work confirming to Fe 410W(Gde E-250 quality A) complete all as specified and directed. |
| 7 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick,Trapezoidal roofing profile with 190 mm Pitch &29 mm depth of profileof any colour having tensile strength of 550 Mpa fixed with self tapping screws/L-type or J-type or cranked hook bolt as complete all as specified and directed. |
| 8 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa fixed with self tapping screws complete all as specified and directed. |
| 9 | M&L Preparing surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with two coats of creosote oil all as specified and directed. |
| 10 | M&L Painting to new steel and iron surface of any description over 10cm in width or girth not otherwise described with two coats of synthetic enamel paint over coat of red oxide primer complete all as specified and directed. |
| 11 | M&L for preparation of old painted steel surface of any description and applying one coat of synthetic enamelled paint complete all as specified and directed. |
| 12 | Dismantling wall and celling board (fibre, pulp, insulation etc) any thickness including cover fillets complete all as specified and directed. |
| 13 | M&L of E-boards \"Everest \" Make 600 X600 X4mm thick, white prelaminated self-embossed reinforced designer ceiling board tiles of approved texture at all height laid on Hot dipped Galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GI sheet and of size 24 X 32X 300mm and spaced at 1200mm centre to centre screwed fixed to the soffit of structure by hanger as approved at 1200mm maximum centres. Hangers of GI wire 2 run 4mm dia to be fixed by approved rawl plug, level and adjusters and screws etc. The last hanger at the end of each main runner shall be greater than 450mm from adjacent wall. Flush fitting of 1200mm long cross tee (with double stitching) to be interlocked between main runners at 600mm centre to centre to form 1200 X600mm modules, cross tee longer than 600mm to be supported independly 600 X600mm modules to be formed by fitting 600mm long cross tee centrally between 1200mm cross tee. The perimeter wall angle shall be of 0.45mm thick GI sheet of size 19mm X19mm and 3000mm long of white powder coated all as specified by manufacturer instruction complete all as specified and directed. |
| 14 | Demolition of stone/ brick masonry built in cement or cement lime mortar as in portion ordered complete all as specified and directed. |
| 15 | M&L for brick work with old size sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 16 | Taking down cement or cement lime plaster on brick wall, ceiling incl. Raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 17 | M & L 10mm thick plaster in CM 1:6on fair surfaces of walls finished even and smooth w/o using extra cement complete all as specified and directed. |
| 18 | M&L for 15mm thick plaster in CM 1:4on fair faces of brick work or concrete surface finished even and smooth w/o using extra cement complete all as specified and directed. |
| 19 | M&L preparation new plastered surfaces of wall and providing two coat of cement base paint over a coat of primer complete all as specified and directed. |
| 20 | M&L for preparing of old surfaces of walls by washing rubbing down & stopping of painted surfaces and applying one coat of cement base paint, in any colour complete all as specified and directed. |
| 21 | M&L for preparing of old surfaces of walls, pillasters, cornices etc by washing, rubbing down & stopping etc and applying one coat of oil bound distemper in any colour complete all as specified and directed. |
| 22 | M&L for preparation of old plastered surfaces of wall and applying one coat of weather proof exterior emulsion paint complete all as specified and directed. |
| 23 | M&L for preparation of surface 1mm thick wall care putty complete all as specified and directed. |
| 24 | M&L for preparation of new plastered surfaces of wall over a coat of primer on surface and applying two coats ofoil bound distemper complete all as specified and directed. |
| 25 | M&L for preparation of new plastered surfaces of walland applying three coat ofwhite wash complete all as specified and directed. |
| 26 | M&L for preparation of old painted surfaces of wood & wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 27 | M&L for Preparation of wood and wood based materials surfaces of new or old, of any description and girth,and applying one coat of Creosote oil complete all as specified and directed. |
| 28 | M&L for Preparation of wood and wood based materials surfaces of new or old, of any description and girth,and applying two coat of Creosote oil complete all as specified and directed. |
| 29 | M&L for providing plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as kerb or benching to wall and similar work complete all as specified and directed. |
| 30 | M&L for preparation of new surfaces of wood & wood based material of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat pink primer complete all as specified and directed. |
| 31 | Taking down carefully copper/Aluminium point wiring (light/fan/socketor power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc., removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making gooddisturbed surfaces of wall, floors etc. complete all as specified and directed. |
| 32 | Taking down Distribution Boards along with MCB\"s incl removing the same from site and making good to the disturbed surface complete all as specified and directed.Note: All taken down MCBs should be deposited to MES store by the contractor without any extra charge. |
| 33 | Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc. complete all as specified and directed. |
| 34 | M&L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multistranded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thickmarked laminated sheet cover for fixing switches/socket/regulators and making gooddisturbed surfaces of wall, floors etc. for the following: Note:- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing capping and its accessories. |
| 35 | One light/fan/bell point controlled by one No piano type switch5 Amps single pole one way |
| 36 | One socket outlet 5/3 pin 6 Amps controlled by one switch on the same board. |
| 37 | One socket outlet 5/3 pin 6 AMPS controlled by one switch onindependent board. |
| 38 | All as per Ser item No 34.00 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm for earth continuity conductor complete all as specified and directed. |
| 39 | All as per Ser item No 34.00 above but for sheet metal enclosure box all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 4.00 sq mm for phase & neutral & 4.00 sq mm for earth continuity conductor complete all as specified and directed. |
| 40 | S&F Switch Piano Flush button single pole one way 5/6 Amp complete all as specified and directed. |
| 41 | S&F Switch Piano Flush button single pole one way 15/16 Amp complete all as specified and directed. |
| 42 | S&F socket outlet 2 in 1,3 pin & 2 pin, 5/6 Amp, 240 volt complete all as specified and directed. |
| 43 | S&F socket outlet 2 in 1 ,3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt complete all as specified and directed. |
| 44 | S&F ceiling rose surfaceBakelite 65mmx50mm 100watt three terminal complete all as specified and directed. |
| 45 | S&Fstep typeelectronicfan regulator flushtype on the existing phenolic laminated sheet complete all as specified and directed. |
| 46 | S&F Lamp holder/Batten holder PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting complete all as specified and directed. |
| 47 | S&F Bell Ding Dongtype, AC 230 Volts, Single pole complete all as specified and directed. |
| 48 | S&F Bell Push, flush type, 5 Amp, AC-230 Volts, single pole complete all as specified and directed. |
| 49 | M&L for sub main wiring concealed with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly and making good to the disturbed surface complete all as specified and directed.Note:-(i)One run of conduit three run of 6 sq mm copper conductor is measured as one unit.(ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories. |
| 50 | S&F in replacement single pole and neutral enclosure with a two pin and earth socket complete with top and one single pole MCB of 20 Amp 240 volt and making good to the disturbed surface complete all as specified and directed. |
| 51 | S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps 240 volts and making good to the disturbed surface complete all as specified and directed. |
| 52 | S&F MCB SP 5 to 32 Amps 240 volts \"C\" series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1 complete all as specified and directed. |
| 53 | S&F MCB SPN 32-40 Amps 240 volts \"C\" series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1complete all as specified and directed. |
| 54 | Taking down ceiling/exhaust fan, sealing cable end, dismantling blades and refixing the same complete all as specified and directed. |
| 55 | Supply and fixing LED 4\" batten light18/20 Watt230 Volt, complete connection with PVC insulated multi stranded copper flexiblewire twin core of suitable size from nearest source complete all as specified and directed. |
| 56 | Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ionizer and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and directed.Note : The cost of making suitable opening in brick walland making good of surface is included in quoted rate and no extra payment will be made to contractor in this effect. |
| 57 | Supply and fix MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. |
| 58 | Supply and fix of wall mounted type electronic voltage stabilizer, Copper Wound, Single Phase suitable for working range between 130 V to 280 V with time delay of 3Min ± 20 Sec and output voltage stabilized to 220 V ± 10% with high voltage cut-off and thermal overload protection complete of capacity 4KVA all as specified and directed. |
| 59 | Supply and fix MS powder coated wall mounting bracket kit for AC outdoor unit suitable for 1.5 TR AC along with suitable fasteners complete all as specified and directed. |
| 60 | Material and labour for sub main wiring 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm (earth wire) with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc complete all as specified and directed. Note: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. (ii) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. |
| 61 | S&F MCB, single pole & neutral 40/63 Amps,230 volts, 50 HZ, \"C\" curve complete all as specified and directed. |
| 62 | S&F MCB, single pole 6 /10/16/20/25/32 Amps,230 volts, 50 HZ, \"C\" curve complete all as specified and directed. |
| 63 | S&FSingle pole and neutral DB\"s with 200 Amp rated copper bus bar made of sheet steel enclosure (housing), double door recessed type factory made duly painted 4 way suitable for mounting one incomer, 2 pole, 240 volts isolator/RCCB/MCB and outgoing SPN/SP respectively including colour coated bus bar, Neutral link, Earth bar and Din Rail, mounting bracket, fixing clamps, etccomplete all as specified and directed. |
| 64 | Supply and fixing for ceiling fans complete with blades, down rods, ectronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 65 | Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition complete all as specified and directed. |
| 66 | Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition complete all as specified and directed. |
| 67 | M&L for point wiring with 1.5 Sqm, single core, PVC insulated with multistranded PVC unsheathed copper conductor cable in and inlcluding rigid non metallic PVC concealed conduit 20 mm dia or higher, med grade , ISI marked complete with all PVC conduit accessories/fittings and sunk CI/pressed steel terminal switch boxes with 3 mm thick, top cover, concealed in wall including earth wire of PVC insulated unsheathed 1.5 Sqmm copper conductor connected to all fittings, sunken boxes and common earth and connected to earth dolly screwed with brass screws, compelte all as specified and directed for One fan point controlled by one, one way switch, 5/6 Amps complete all as specified and directed. |
| 68 | S&F Switch Piano Flush button single pole one way 5/6 Amp complete all as specified and directed. |
| 69 | Supply and installation of split air conditioner 1.5 Ton, 5 star rating, ISEER >= 4.0, incl hi wall split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality incl necessary gas charging with refrigerant 134a complete all as specified and directed. |
| 70 | Supply & installation of Water cooler partially stainless steel, electric driven single phase having approx storage capacity 80 Ltr and nominal cooling capacity 40 Ltr incl brass (chromium plated) faucets 02 Nos, copper condensing tube, water inlet & outlet hose pipe, chiller tank SS-304, drip tray SS-304 front, PUF thermal insulation, plug top etc complete all as specified and directed. |
| 71 | M&L for Sub main wiring with 2 run single core, 6 Sqmm, PVC insulated and usheathed stranded FRLS copper conductor cable in and includng PVC concealed/surface conduit, 25 mm or higher dia, complete with all PVC conduit ISI marked complete with all accessories/fittings including extension of earth wire with one run 6 Sqmm PVC insulated copper cable, single core, fixed alongwith the sub main cable in PVC conduit with clips and connecting to earth dolly with all fixing material complete all as specified and directed.Note: Three runs (1P+1N+1E) of single core cable along with PVC conduit shall me measured as one length. |
| 72 | S&F SPN enclosure with a two pin and earth plug and socket complete with one MCB, SP capacity 25/32 Amps, 10 KA, 240 volts complete all as specified and directed. |