Water Resources and Irrigation Government Departments Closing in 0 days TDR #37241050

Tender For Kiifb-Thalassery Heritage Project Phase 1 - Cultural Circuit-Kakkulangara Mosque-Conservation And Street Scaping Of Kakkulangara Mosque, Valapattanam, Kannur District-General Civil Work

Issued by Government Departments · valapattanam, Kerala
Tender Value
87.43 Lakhs
Estimated cost
Bid Submission
28 Apr 2023
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
valapattanam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Kiifb-Thalassery Heritage Project Phase 1 - Cultural Circuit-Kakkulangara Mosque-Conservation And Street Scaping Of Kakkulangara Mosque, Valapattanam, Kannur District-General Civil Work

BOQ

Work Name:KIIFB-Thalassery Heritage project Phase 1 - Cultural Circuit-Kakkulangara Mosque-Conservation and streetscaping of kakkulangara mosque, valapattanam, Kannur District-General Civil Work
Sl. No. Item Description
1Appendix A-Conservation of mosque
22.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
314.85:Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
4OD33625/2022-2023: Polishing the doors and windows with malamine polish including all charges etc. complete.
513.31.1:Pointing on brick work or brick flooring with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled /Struck or weathered pointing
613.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
7OD33626/2022-2023: Setting up of a document with Photographs of site before and after the work. The item includes developing of a photographs to a size of 6"x4" and preparing a booklet.
8Appendix B- Pathway
916.91.2:Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
1016.69:Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
11Appendix C- Conservation of kulappura
1215.14.1:Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above
1310.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
1412.48:Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)
1512.49:Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).
16OD33624/2022-2023:Providing & fixing on roof pressed clay ceiling tiles 30x25cm size of 20 mm nominal thickness and of approved size and as per approved pattern
1713.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
1813.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
19Appendix D- Gallery and Toilet block
202.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
214.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
227.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
232.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
245.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
255.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
265.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
275.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
285.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
295.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
3050.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
315.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
324.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
335.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
349.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
359.5.1.1:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters
369.7.1:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelledand glazed shutters 25 mm to 40 mm thick:Second class teak wood
3713.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
389.141:Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut joints and with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer-in--charge.
399.142.1:35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded solid PVC ( ±0.2 mm) thick, having styles & rails (except lock rail ) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinges side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm x 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm x 100 mm of cross section size 35 mm x 17 mm s 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm x 35 mm, out of which 95 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge.Non decorative finish (matt finish)
4011.26.1:Kota stone slab flooring over 20 mm ( average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)25 mm thick
4111.27:Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
4211.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
4311.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
4410.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
4513.48.2:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture
4613.48.3:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
4710.16.2:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
4812.48:Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)
4912.49:Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).
50OD33622/2022-2023: Providing & fixing on roof pressed clay ceiling tiles 30x25cm size of 20 mm nominal thickness and of approved size and as per approved pattern
5110.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
52Appendix E- Plumbing and Miscellaneous
5350.18.7.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
5450.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall
5550.18.7.4.2:Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall
5650.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
5750.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
58OD33627/2022-2023:Providing and fixing (UN0002) Universal Angle Cock of superior quality Jaguar or equivalent
59OD33628/2022-2023: Providing and fixing (579 CHR) HEALTH FAUCET of Superior quality Jaguar or equivalent brand
60OD33629/2022-2023:Providing and fixing (089 ALD c) stop cock of superior quality 15 mm nominal bore Jaguar or equivalent brand
61OD33630/2022-2023:Providing and fixing superior quality brand CP Soap Dish Holder concealed fitting arrangements, weighing not less than 106 gms
62OD33631/2022-2023:Providing and fixing C.P. brass bib cock of superior quality Jaguar or equivalent brandconforming to IS:8931. 15 mm nominal bore
63OD33632/2022-2023: Supply & Fixing square Cockroach proof Traps with CP Gratings. Unloading materials supplied at site and storing it in safe place provided in the site. (Make: ACO/SGS )
64OD33633/2022-2023:Providing and fixing superior quality white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.l.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid JAQUAR LYS-WHT-38851S300UFSM or Equivalentapproved municipal design complete, including painting of fittings and brackets, cutting and makinggood the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid
6517.4.2:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
66OD33634/2022-2023:Providing and fixing Cavier SS towel rod complete with brackets fixed to woodencleats with CP brass screws with concealed fitting arrangement of approved quality and colour. JAQUARACN-1111SM or Equivalent
67OD33635/2022-2023: Providing and fixing superior quality White Vitreous China Wash basin size 630x450mm with a pair of 15 mm C. P. brass pillar taps with C.I. brackets, 32 mm waste pipe of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required ect. complete: JAQUAR ARS-WHT-39803 or Equivalent
6851.19.ST4:Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately) 4. 35 to 50 flush capacity
6919.32.1:Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
70Appendix F- Landscaping
71OD33616/2022-2023: Supplying and planting of approved shrubs at required spacing as shown in drawing. Rate shall include cost of plants soil work,manure and fertilizers used in top dressing, chemical and machanical pest control, staking and maintaining the planting till it is handed over from the date of planting labour charges, pest control operating etc. (9)Oleander tall
72OD33617/2022-2023: Supplying and planting of approved shrubs at required spacing as shown in drawing. Rate shall include cost of plants soil work,manure and fertilizers used in top dressing, chemical and machanical pest control, staking and maintaining the planting till it is handed over from the date of planting labour charges, pest control operating etc. (1)Aglonema
73OD33618/2022-2023: Supplying and planting of approved palms to a specified locations as shown in drawing. Rate shall include pitting, soil work, staking and planting of palms. sapling and for providing a pit size 75 x 75 x 75 cm. (4)Red Palms 1.2m Height
74OD33619/2022-2023: Supplying and planting of approved specimen plants to a specified locations as shown in drawing. Cost of plants, soil work inclusive of red soil, sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 75 x 75 x 75 cm and maintainance till the competion of project work.(6)Ficus Panda
75OD33620/2022-2023:Supplying and planting of approved trees species of a height 2.0m to 2.5m, at the specified location as shown in the drawing.Rate shall include Cost of plants, soil work inclusive of red soil, sand and manure mix staking and planting of trees sapling, replacement of dead trees and for providing a pit size 75 x 75 x 75 cm and maintainance till the competion of project work.( 1).Plumeria Alba
76OD33621/2022-2023: supplying and laying the paspullam over the leveled and prepared surface.the rate shall include the cost of grass mat input manure and fertilizers used periodically for top dressing ,chemical and mechanical pest control and all post planting maintanance procedure complete till the complection of project 1)Buffallo grass
772.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
784.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
79OD33990/2022-2023:Supply and providing suitable size foundation bolts and nuts with washers for lamp poles, bollards, outdoor lamp fittings etc.
80Appendix G- Pond Renovation
812.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
824.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
8350.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
84OD33658/2022-2023:providing and laying laterite masonry coping above the compound wall with neatly dressed laterate stone of size 30x15x10cm or nearest size in cement mortar 1:6including all cost of materials, labour charges etc.
85Appendix H- Compound Wall
862.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
874.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
8850.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
89OD33615/2022-2023:providing and laying laterite masonry coping above the compound wall with neatly dressed laterate stone of size 30x15x10cm or nearest size in cement mortar 1:6including all cost of materials, labour charges etc.
9013.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
9110.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
9213.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
9313.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
94APPENDIX I- Renovation of entrance building
9514.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
965.18.3:Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement : 3 fine sand ) etc. complete excluding plastering of the jambs, sills and soffits.25 mm thick
97OD33611/2022-2023:Providing wood work in hand rail, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter, length - second class teak wood (As per 9.1.1).
9813.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
99OD33612/2022-2023:Providing and fixing Sadarhalli granite stone laid over 20 mm thick base cementmortar 1:4 ( 1 cement : 4 coarse sand), joints treated with cement. complete at all levels.Area of slab over0.50 sqm
10012.48:Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)
10112.49:Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).
102OD33613/2022-2023: Providing & fixing on roof pressed clay ceiling tiles 30x25cm size of 20 mm nominal thickness and of approved size and as per approved pattern
103OD33614/2022-2023:Providing and fixing second class teakwood eve board 20cm wide including allcharges etc complete
10413.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
105APPENDIX J-ELECTRIFICATION
1061.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
1071.12:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1081.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1091.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1101.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1111.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1121.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1131.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1141.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1151.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1161.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1171.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1181.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1192.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
1202.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
1212.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1222.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1232.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
1242.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
1252.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1262.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1272.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1285.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1295.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
13090.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
13190.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
1327.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
13390.11.1.14:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
13490.12.1.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm
13590.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
136OD33637/2022-2023:Supply and laying of 2.5 sq.mm 2 core PVC/XLPE insulated armouredcopper conductor cable for working voltages upto and including 1100V conforming to IS 1584/Part I/1988 for PVC & IS 7098 Part I for XLPE
13790.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
1389.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
1399.3.29:Supplying and making straight through joint with cast resin compound including ferrules andother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm
14090.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
141OD33638/2022-2023:Supply, installation, testing and commissioning of 6W wall speakers with line matching transformer suitable for 4 ohm impedance.
14290.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
143OD33639/2022-2023:Supply, installation , testing and commissioning of exhaust fans of size up to450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc.,as required including giving connections with the supplied wire along with theexhaust fan.300/305mm light duty
144OD33640/2022-2023:Supply, conveyance, installation, testing and commissioning of ceiling fans of thefollowing sizes using standard accessories excluding resistance type regulator,wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed650/1100V grade 3 core round copper conductor flex wire or with extendedoriginal wiring etc. as required 1200mm sweep -BLDC ceiling fancomplete with 300mm down rod , canopies, shackeles and blades and resistancetype regulator working on 230V/240V single phase A/C
145OD33641/2022-2023:Supply and installation of environment friendly, energy efficient, aesthetically designed, wall/ceiling mounted LED fixture with diffuser to give glare free light, 5W LED 6000K
146OD33642/2022-2023:Supply and fixing of decorative outdoor wall light with 13.5 W Cool Daylight (CDL), ExcellentCRI>80 , IP54.
147OD33643/2022-2023:Supply and fixing of 2W LED step light, Aluminium base and powder coated finish
148OD33644/2022-2023:SITC of decorative,wall mounting fixture in durable plastic body and designer mesh in gold finish suitable for 9 W LED lamp
149OD33645/2022-2023:Supply and fixing of track accessories for housing track light, 1 meter linear length
150OD33646/2022-2023:Supply and fixing of 15W track light with high power COB LED
151OD33647/2022-2023:Supply and fixing of of 12W LED hanging light with extruded aluminium housing with microtexture powder coating.
152OD33648/2022-2023:Supply and fixing of LED spike light with die cast aluminium housing with warm white COB LED reflector with IP65protection. 9W LED
153OD33649/2022-2023:Supply and fixing of recess mount type,20W LED wall washer downlight, tiltable type
154OD33650/2022-2023:Supply and fixing of 5W cool day light LED tube light, polycarbonate body
155OD33651/2022-2023:Supply, conveyance, installation, testing and commissioning of environment friendly,ultra modern,energy saving, surface mounted decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs. 10W 6000K with IP65 protection
156OD33652/2022-2023:Supply, conveyance, installation, testing and commissioning of 30W flood light with high pressure diecast aluminium and IP 65 protection
157OD33653/2022-2023:Supply and fixing of environment friendly, ultra modern, energy saving, long life, aesthetically designed aluminiumlandscape bollard with high power LED as light source. 8W 5000K, 500mm with IP 65 protection
158OD33654/2022-2023:SITC Of feeder pillar complete with the following accessories. Incomer: 40A,DP,Isolator. 40A, DP, RCCB, 100mA. Timer control with contactor. Auto/Manual switch. Outgoing: 10A, SP MCB - 4 Nos
159OD33655/2022-2023:Supply and fixing 63A, 415 V, 2 way neutral link mounted on DMC/SMC base in the existing meter board
160OD33656/2022-2023:Supply and fixing 63A HRC fuse base with fuse link in the existing meter board
161OD33657/2022-2023:Supply & installation of dust and vermin proof, 3 PhaseMeter Board (size 760x450x260x) and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc.as required.

AI Tender Summary

OUR REF NO 37241050
AUTHORITY Government Departments
TENDER VALUE 87.43 Lakhs
LAST DATE 28-04-2023
Authority
Authority Name Kerala Irrigation Infrastructure Development Corporation Limited
Work Description Tender For Kiifb-Thalassery Heritage Project Phase 1 - Cultural Circuit-Kakkulangara Mosque-Conservation And Street Scaping Of Kakkulangara Mosque, Valapattanam, Kannur District-General Civil Work
Basic Detail
Tender No IRR/KIIDC/TR/2185/2023_5_1_1/1
Bidding Type Tender
Location
City valapattanam
State Kerala
Key Dates
Publish Date 13 Apr 2023
Submission Date 28 Apr 2023
Open Date 01 May 2023
Finance
Tender Value 87.43 Lakhs
Tender Fee 2760
EMD 50000
Exemption Not Available
Document List
3cb5e505-b493-445d-9058-1f67eb31dff0.html
BOQ_844314.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 13, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 28, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 01, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3cb5e505-b493-445d-9058-1f67eb31dff0.html

xls

BOQ_844314.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders