Tender For Electrification For Modify Na-Ii Quarters To Inspection Quarters -Ii At Kanyakumari Lighthouseunder Chennai Directorate., Chennai-Tamil Nadu

Directorate Of Lighthouses And Lightships has published Tender For Electrification For Modify Na-Ii Quarters To Inspection Quarters -Ii At Kanyakumari Lighthouseunder Chennai Directorate.. Submission Date for this Tender is 25-04-2023. Electrification Work Tenders in Chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

37239986
Tender For Electrification For Modify Na-Ii Quarters To Inspection Quarters -Ii At Kanyakumari Lighthouseunder Chennai Directorate.
Open Tender
NCB
Tamil Nadu
Chennai
25-04-2023

Tender Details

Electrification For Modify Na-Ii Quarters To Inspection Quarters -Ii At Kanyakumari Lighthouseunder Chennai Directorate. 1 Supplying And Fixing Following Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 2 1 Or 2 Module ( 75Mm * 75Mm ) 3 3 Module ( 100Mm * 75Mm ) 4 4Module ( 125Mm * 75Mm ) 5 6Module ( 200Mm * 75Mm ) 6 8Module ( 125Mm * 125Mm ) 7 12 Module ( 200Mmx150mm ) 8 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 9 5 / 6 A Switch 10 Two Way 5 / 6 A Switch 11 3 Pin 5 / 6 A Socket Outlet 12 6 Pin 15 / 16 A Socket Outlet 13 Bell Push 14 Supplying And Fixing Pvc Batten / Angle Holder Including Connections Etc. As Required. ( Fancy Type ) 15 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 16 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 17 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required 18 Installation, Testing, Commissioning Of Wall Bracket / Ceiling Fittings Of All Sizes And Shapes Containing Upto Two Gls / Cfl / Led Lamps Per Fitting, Complete All Connections Including Connections Etc, As Required. 19 Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tube / Lamp Etc. Directly On Ceiling / Wall, Including Connections With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. 20 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 21 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc As Required 22 Upto 450Mm Sweep 23 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. Conduit As Required. 24 25 Mm 25 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 26 2 X 1.5 Sq. Mm ( For Lamp Holder ) 27 3 X 1.5 Sq. Mm 28 3 X 2.5 Sq. Mm 29 3 X 4 Sq. Mm 30 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required 31 Single Pole 10A 32 Single Pole 20A 33 Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Commissioning Etc. As Required. Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 34 63A 35 Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 36 63 A 37 Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 38 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1Kv Grade Of The Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required 39 Upto 35 Sq.Mm 40 Providing, Laying And Fixing The Following Dia G.I. Pipe ( Medium Class ) In Ground Complete Including Trenching ( 75 Cm Deep ) And Re-Filling Etc As Required ( For Cc Road Crossing ) 41 100Mm Dia 42 Supply Of Indoor Industrial Led Batten 36 Watts 1150 Mm. ( Refer Sl No. 19 For Installation ) 43 Supply Of 12W Round Led Recessed Luminaire Operating140v To 280 V At 50 Hz Ac / Smd Led Chip As Per Lm 80 / Is16106 ( Refer Sl No. 18 For Installation ) 44 Supply Of 24W Squareled Recessed Luminaire Operating140v To 280 V At 50 Hz Ac / Smd Led Chip As Per Lm 80 / Is16106 ( Refer Sl No. 18 For Installation ) 45 Supply Of 22W Squareled Surface Mounted Luminaire Operatingfrom 100V 50Hz Supply ( Refer Sl No. 18 For Installation ) 46 Supply Of 30W Led Flood / Focus Light Of Ip65 Suitable For Out Door Purpose. ( Refer Sl No. 19 For Installation ) 47 Supply And Fixing Of Led Type 700Mm Dia Multi Colourhanging Type Classic Chandeliers Of 50 Watt Suitable Fixing At Middle Of The Hall 48 Supply Of 200Mm Sweep Exhaust Fan Suitable For Bath Rooms And Kitchen ( Refer Sl No. 21 For Installation ) 49 Supply Of 1200Mmbldc Decorative Ceiling Fan 5Star Rating With Remote Control For Speed Regulations. ( Refer Sl No. 20 For Installation ) 50 Supply And Laying Of 4 Core X 10 Sq.Mm Copper Armoured Pvc Insulated / Pvc Sheathed Xlpepower Ug Cable As Required. ( Laying From Pump Room To Iq ) ( Refer Sl No. 38 For Laying ) 51 12W Wash Basin Cum Mirror Light ( Refer Sl No. 18 For Installation ) 52 Supply Of Led Lamp 10W ( Base B22 10-Watt Led T Tube ) 53 Supply And Fixing On Wall 4Pole Sheet Metal Type Powder Coatedmcb Gang Box Suitable To Fix 4Pole 63A Isolator At Pump Room. 54 Supplying And Drawingof 4 Core X 10 Sq.Mmfrls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required For Incomer Connections. 55 Supplyand Fixing Of Single Module Modular Indicator Operating 230V / 50Hz Supply. 56 Supply Of 6 Way Tpn Double Door Vertical, Sheet Metal Type, Powder Coating Distribution Box With Three Nos. 63A Phase Selector Switch And Three Indicators Without Mcb, Isolator And Rccb. ( Refer Sl No. 57 For Installation ) 57 Fixing Of6 Way Tpn Double Door Vertical, Distribution Box In Recessed By Cutting And Breaking The Black Stone Masonry Andplastering Etc As Required 58 Supply And Fixing Of Single Pole 16A C Curve Modular Mcb In Existing 2M / Single Metal Box And Platefor Air Conditioner. 59 Supply Of Bare Copper Wire, 8 Swg Earth Wire. ( Refer Sl No. 37 For Installation ) 60 Labour Charge For Laying 8 Swg Wire From Ground Level To Distribution Box Through Pvc Pipe Recessed. 61 Supply And Installation Of Multi Musical Call Bell With Flash Light. 62 Supply Of Decorative Wall Mounting Type Fancy Light Fitting ( Refer Sl No. 18 For Installation ) 63 Supply Of High Contrast Ip65 Water Proof Out Door Rope Light Suitable For False Ceiling Decorations. ( Refer Sl No. 64 For Installation ) 64 Charges For Connections Laying Of Rope Light In The Existing Cavity On The False Ceiling 65 Supply Of 4Module Led Foot Light ( Refer Sl No. 18 For Installation ) 66 Supply Of 1 / 2 Flexible Hose For Ceiling Lights 67 Black Stone Cutting Charges For Laying The Pvc Pipes And Switch Boxesfor Concealed Wiringas Buildings Are Constructed By Black Stone 68 Charges For Making 10.5 Square Hole On Blackstone Masonry Wall For Fixing Of Exhaust Fan 69 Core Cutting Charges For Making 4 Hole On Black Stone Masonry Wall Of Installation Of Air Conditioners In Hall, Bed Room 1 & Bed Room 2 70 Making Earth Pit Charges ( Additional ) Of Sl No.16 Due To The Site Located Near Beach Area And Sand Area Difficult To Digging Earth Pit ( Take Out Water And Labour Charges ) 71 Charges For Removing The Existing Wiring, Light Fittings, Fans Etc And Handed Over To Incharge Of Lighthouse. 72 Miscellaneous Items For The Purchase Of Screws, Bolts, Nuts & Washers, Cable Ties, 25Mm Pvc Bends, Tees, 1, 2, 3, 4 Way Junction Boxes, Fan Rod For Extension, Ss Clamp, Pvc Insulation Tape Etc.,

Key Value

Document Fees
INR 500 /-
EMD
INR 11663.0 /-
Tender Value
INR 5.83 Lakhs /-