Tender For Electrical Works At Fsd Jowai Meghalaya For The Year 2023-24. Sh Repair Maintenance Of Ei And Improvement Of Illumination At Fsd Jowai Meghalaya., jowai-Meghalaya

Food Corporation Of India-FCI has published Tender For Electrical Works At Fsd Jowai Meghalaya For The Year 2023-24. Sh Repair Maintenance Of Ei And Improvement Of Illumination At Fsd Jowai Meghalaya.. Submission Date for this Tender is 26-04-2023. Electrical Maintenance Tenders in jowai Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

37239744
Tender For Electrical Works At Fsd Jowai Meghalaya For The Year 2023-24. Sh Repair Maintenance Of Ei And Improvement Of Illumination At Fsd Jowai Meghalaya.
Open Tender
Indian
Meghalaya
jowai
26-04-2023

Tender Details

Electrical Works At Fsd Jowai Meghalaya For The Year 2023-24. Sh Repair Maintenance Of Ei And Improvement Of Illumination At Fsd Jowai Meghalaya.

Key Value

Document Fees
Refer document
EMD
INR 11855.0 /-
Tender Value
INR 5.92 Lakhs /-

BOQ Items

Name of Work: Electrical works at FSD Jowai Meghalaya for the year 2023-24.SH: - Repair, Maintenance of EI and improvement of illumination at FSD Jowai Meghalaya.
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
23 x 1.5 sq. mm
34 x 1.5 sq.mm
43 x 2.5 sq.mm
5Earthing with G.I. earth pipe 4.5 mtr long 40 mm dia including accessories ,and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal /cokeand salt etc as required.
6Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
7Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.
8Supplying and fixing of following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
9Single Pole & neutral
10Supplying anf fixingfollowing size/modules, G.I box along with modular base & cover plate for modular switches in recess etc. as required
113 Module (100 mm X 75 mm)
1212 Module (200 mm X 150 mm)
13Supplying and fixing following modular switch/socket on the existingmodular plate & switch box including connections but excluding modular plate etc. as required.
141 Way 5/6 Switch
153 pin 5/6 socket outlet
1615/16 A Switch
176 pin 15/16 A Socket outlet
18Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1920 mm dia
2025 mm dia
21Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required
22Supplying of following size XLPE insulated & PVC tape innersheathed aluminium conductor armoured cable of 1.1 KV grade of following size confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.
232 x 10 Sq.mm
24Supply,installation testing & commissioning of36 Watt cool day light 2ft X 2ft LED surface full lit luminaire with >100 Lumen/Watt
25Supply,installation testing & commissioning of18 Watt cool day light 1ft X 1ft LED surface full lit luminaire with >100 Lumen/Watt
26Supply,installation,testing & commissioning of integral well glass luminaire compressed of dia cast canopygear box housing and glass driver surge with heat resistance glass of LED well glass fitting of 40 watt. 110 Lm/watt to 125Lm/Wattor Luminous should not be less than 4200 as per direction of Engineer in-charge as per direction of engineer-In-Charge.
27Supply,installation,testing & commissioning of integral well glass luminaire compressed of dia cast canopygear box housing and glass driver surge with heat resistance glass of LED well glass fitting of 70 watt. 110 Lm/watt to 125Lm/Wattor Luminous should not be less than 7700 as per direction of Engineer in-chargeas per direction of engineer-In-Charge.
28Supply of LED street light fitting of 60 watts,240 voltsof streetlight pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP65 protection.
29P/F of cable termination of PVC box of size 20cm X 15cm X 10 cm with compression termination arrangements, 6-10 Amp SP MCB and double natural link etc as required.
30Credit items for old dismantled non functional unserviceable 16/20W LED Tube Light Fittings
31Credit items for old dismantled rusted Steellight pole.