Tender For Preparing Of Pitch And Lightning Arrangement At Bbmb Cricket Ground Near Office Club Nangal Township
Tender Overview
Project Description
Preparing Of Pitch And Lightning Arrangement At Bbmb Cricket Ground Near Office Club Nangal Township
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-May-2023 | Corrigendum 1 | Date | 29-May-2023 |
| 2 | 30-May-2023 | Corrigendum 2 | Date | 19-Jun-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Civil Items |
| 2 | Excavation for Roadway by Mechanical Means ( b) Excavation for roadway in soil by mechanical means with dozer including cutting and pushing earth to embankment site with all lead and lifts up to 100m including trimming bottom and side slopes as per technical clause 301 of MORT&H specifications CSR item 24.6(b) |
| 3 | Sand filing including carriage (M.R.) |
| 4 | Black clay filling including compaction(M.R.) |
| 5 | Fine grassing including uprooting rank vegetation and weeds by digging the area to a depth of 30 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days, mixing fertilizer and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts, watering, weeding and maintenance for 30 days or till thick lawn is formed.(a) Planting Selection no. 1 grass roots in rows 5 cm apart in both directions. CSR 32.9 (a) |
| 6 | Cement concrete 1:8:16(B)With stone aggregates 40mm gauge(ii)mixing by mechanical means using concrete mixer volumetric type CSR 10.6(b)(ii) |
| 7 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS: 1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and plinth. CSR 10.15 |
| 8 | Cold twisted deformed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. CSR 18.18 |
| 9 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) CSR 9.1 |
| 10 | Centering and shuttering for columns (Square or rectangular or polygonal in plain) CSR 9.4 |
| 11 | Steel work fixed independently without connecting plates including cutting hoisting and fixing in position(a) R.S Joists CSR 18.1(a) |
| 12 | ELECTRICAL ITEMS |
| 13 | LUMINARIES SUITABLE FOR FLOOD LIGHTING SYSTEM FOR PLAY GROUND:Supply of BIS approved LED flood light luminaries with aluminum pressure di-cast housing with unique integrated peanut lens optic anti dust exposed lens and heat proof ceiling on rubber for maintaining IP protection. Luminaries should be design to emit at least 47000 nominal lumens with maximum system wattage of 390 watt at a system efficacy of at least 120 lumens per watt.The luminaries should be design to ensure lumen depreciationof upto 30% over 50000 burning hours at design ambient temperature 35 °cLuminaries type BVP 483P LED 235 SMB (M.R.) |
| 14 | Supply of BIS approved LED flood light luminaries with aluminum pressure di-cast housing with unique integrated peanut lens optic anti dust exposed lens and heat proof ceiling on rubber for maintaining IP protection. Luminaries should be design to emit at least 21000 nominal lumens with maximum system wattage of 350 watt at a system efficacy of at least 120 lumens per watt.The luminaries should be design to ensure lumen depreciationof upto 30% over 50000 burning hours at design ambient temperature 35 °cLuminaries type BVP 483P LED 210 NB(M.R.) |
| 15 | High Mast light Pole 30 Mtr. height without head frame. (M.R.) |
| 16 | Head frame for Luminaries (M.R.) |
| 17 | Copper cable 5 core 4mm2 Ground to light (M.R.) |
| 18 | Nuts and bolts of all sizes and length required(M.R.) |
| 19 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated PVC sheathed 3 core round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4.0sq.mm (84/0.3mm), 3Core CSR item No. 34. 09 xiii (d) |
| 20 | XLPE INSULATED ARMOURED CABLES (UNDERGROUND):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & bricks and back filling the trench etc., of the required size as per PWD General Specifications:-Overall size 16sq.mm (4Core) Armoured (Underground) CSR item No. 34.10 (A) xxxvii |
| 21 | Overall size 35sq.mm (3½ Core) Armoured (Underground) CSR item No. 34.10 (A) xxiii |
| 22 | COPPER EARTHING (Upto 8 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC cap (For pouring Water)fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation:- Earthing with 25mm x 3mm Copper Tape (upto 8Metre in Length) CSR item No. 34.14 ii (b) |
| 23 | COPPER EARTHING STRIP (As Additional Length): Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc:- Additional Length 25mm x 3mm thick Copper TapeCSR item No. 34.14 iv (b)(v) |
| 24 | SHEET METAL IRON CLAD SWITCHES:-Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- ICTPN Switch 200amp. 415volts. CSR item No. 34.18 viii |
| 25 | LT PANELS & MCCB\"s (MOULDED CASE CIRCUIT BREAKERS):Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilities for extensions or reduction as per the space or requirements). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication: - Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non-load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. It should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick open-able type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for bus bar/Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company premises) after necessary putty work. Bus bars:-The panel shall be provided with TPN aluminum bus bar of suitable size according to the size of MCCB\"s. Bus bar shall be of high conductivity (53% to 58%) E91-E Grade aluminum (1A/Sq.mm). All Bus bar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable Termination with the help of extended bus bar only with proper adjustable cable supports. The main bus bar would be supported upon non-hygroscopic SMC/DMC supports.Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contactor shall be approved the detailed drawing of panel with complete Specification from the Engineer in charge at site. Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following.LT Panel enclosure with having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCB\"s 40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm) CSR item No. 34.23 (A) iii |
| 26 | MCCB\"S (FOR PANELS & SHEET ENCLOSURE): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (Conforms to IEC:60947-2) having Ics=100%, Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting CSR item No. 34.23 B (i) |
| 27 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. ofthe required size:-Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) CSR item No.34. 37 B (i) |
| 28 | Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) CSR item No. 34. 37 B (iii) |
| 29 | M.S. JUNCTION BOX FOR STREET LIGHT: Supply and erection of M.S. Junction box of suitable size made from M.S. Sheet 16 SWG (1.60mm thick). Junction box should have one locking arrangement and 2 nos. hinges on front side. It should have 1 No. Brass terminal connecting strip, 1 No. Kit kat 16 Amp/240 Volts along with M.S. Flat 20mm x 2mm clamp with nuts and bolts for fixing on the pole. The junction box should be painted with one coat of good quality primer and two coats of post office red enamel paint inside and outside complete in all respect:-M.S. Junction Box 300mm x 200mm x 100mm CSR item No. 34. 38 ii (b) |
| 30 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with check nuts etc. including making necessaryconnections:- Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm CSR item No. 34. 38 C (v) |
| 31 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.m CSR item No. 34. 38 C (vi) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued