Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Khan Basti Chukpora Of Jal Shakti (Phe) Mechanical Division South Awantipora Under Jjm., basti-Jammu And Kashmir

Public Health Engineering Department-PHED has published Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Khan Basti Chukpora Of Jal Shakti (Phe) Mechanical Division South Awantipora Under Jjm.. Submission Date for this Tender is 10-05-2023. Electromechanical Machinery Tenders in basti Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37229071
Corrigendum : Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Khan Basti Chukpora Of Jal Shakti (Phe) Mechanical Division South Awantipora Under Jjm.
Open Tender
Indian
Jammu And Kashmir
basti
10-05-2023

Tender Details

Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Khan Basti Chukpora Of Jal Shakti ( Phe ) Mechanical Division South Awantipora Under Jjm.-2 Supply, Installation, Testing & Commissioning Of Submersible Pumping Unitas Per Is 8034 With Following Specification Are As Under :Pump : Efficiency= Not Less Than 50% Speed = 2900 Rpmdischarge= 7000 Gph Head = 150 Mtrtype Of Pump = Mixed Flow.Type Of Fluid To Be Handled = Clear Watermaterial Of Construction:Impeller = Stainless Steelpump Shaft = Stainless Steel Ss 410.Pump Casing= Cast Iron / Stainless Steelmotor Capacity= Not Less Than 30 Hp Impeller:Rest Specifications As Per Cluase - 1 Of Sbd 3 Fabrication, Providing, Fitting And Lowering Ofcolumn Pipe Conforming To Is: 1239 Of Length 10 Rft Into The 200 / 250 / 300 Mm Casing Dia. Production Well Up To The Desired Depth ; The Job Includes Providing And Welding Of Flanges Conforming Tois: 6392, Table-17 And Pn 16 To These Pipes And Welding Of Flanges In Two Layers To Make The Flanged Joint Strong And Leak Proof. The Pipe Of 10 Ft Length Is To Be Weld On Both Sides With Flanges Using Welding Rod Of Reputed Make. The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Joints Of Column Pipes. The Job Further Includes Cutting Of 2 No. Rectangular Cable Slots In Each Flange. Size: Dn 80Class: C ( Heavy ) 4 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make.Flanges ( As Per Is 6392 / 1997 Table:17 ) Thickness Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint.Welding Electrodedc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm.Nuts And Boltsnuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gasketsrubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Rising Main Is To Be Laid As Per The Instructions Of The Engineer In Charge And Site Requirement.Size : Dn 100Class: B ( Medium ) 5 Earth Work In Excavation By Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed. ( All Kinds Of Soil 01 Meter From Cutting Edge ) 6 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc.In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M And Lift Upto 1.5M. 7 Extra For Every Additional Lift Of 1.5 M Or Part Thereof In Excavation / Banking Excavated Or Stacked Materialin All Kinds Of Soil 8 Providing And Laying Of Stone Soling Including Manual Compaction 9 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation , Footings , Bases For Columns 10 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2 : 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 11 Providing And Laying In Position Cement Concrete Of Specified Grade Of Reinforcement Cement Concreteincluding Curing But Excluding The Cost Of Centring And Shuttering. Finishing And Reinforcement All Work Upto Plinth Level With 1: 1.5 : 3Mix ( 1 Cement , 1.5 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 12 12 Mm Thick Cement Plaster Of Mix 1:4 ( 1 Cement , 4 Fine Sand ) 13 Steel Reinforcement For Rcc Work Including Straightening, Cutting, Bending, Placinng In Position And Binding All Complete Upto Plinth Level Thermomechanically Treated Bars Of Grage Fe-500D Or More 14 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. Size: 80Mm 15 Fabrication, Providing And Fitting Of90-120 Degree Bend / Elbowto Be Fabricated Out Ofg.I Pipe, 1 M Lengthand Flanged On Both Ends Ato Make It Leak Proof. The Flanges Shall Be M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) And Welded On Both Sides. The Job Includes Nuts, Bolts, Gaskets Etc As Per Site Requirement.Size:Dn 100Class: C 16 Cutting Of Hot Dip Galvanized G.I, Pipe Across The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Also Includes Providing And Welding Of M.S Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Advani / Esab / L&T- Ss Bond Make Electrodes To Form Strong Welding Joint By Dint Of Dc Arc Welding. The Job Further Includes Providing And Fitting Of Nuts And Bolts ( Conforming To Is:1363 Part 1St ) And Rubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Size Of The Pipe Isdn 100 , Class-C 17 Fabrication, Providing And Fitting Of Washout Tee With Arm Length 1.2 Feet Each. The Tee Shall Be Fabricated Out Of G.I Pipe With M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends. Size: 100Mmclass: C Class 18 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .The Body And Bonnent Of The Valve Shall Be Of Ductileiron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positionsit Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. The Valve Shall Be Supplied Along With Hand Wheel.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work.The Job Includes Providing And Fitting Of 02 Nos. M.S Flanges Perfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fitted With Rising Main Of The Pumping Unit At Appropriate Spots As Per Site Requirement. Size: Dn100pn:1.6 / 16 19 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) . The Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions.It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work.The Job Includes Providing And Fitting Of 02 Nos. M.S Flanges Perfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fitted With Rising Main Of The Pumping Unit At Appropriate Spots As Per Site Requirement. Size: 100 Mmpn: 1.6 / 16 20 Providing, Fitting, Testing And Commissioning Of50mm Diameter Arv ( Air Release Valve ) As Per Is 14845 To Be Fitted Tog.Irising Main. The Arv Shall Have The Following Specifications: I. Valve Type -Single Chamber, Single Orifice.Ii. End Connection-Flanged Ends To Is 1538 Iii. Working Temperature- 20?C To 45?C Iv. Test Pressure - Body / Seat 2.5 X Pnv. Sealing Ring -Epdmvi. Construction-Ductile Iron With Stainless Steelfloatsvii. Coating -Epoxy With Corrosion Resistance Besides The Above Works, The Job Also Cost On Account Of P / F R.I Gasket, Nuts And Bolts Required For Installation Of Arv And Arrangement Of Gas Cutter / Welding Set At Site. The Job Also Includes Cutting Of 50 Mm Dia Hole In Rising Main And P / F Of50mm Dia.M.S Pipe One Feet Long With One End Flanged Perfectly Adaptable To Flange Of Arv And Other End Welded To 50 Mm Dia Hole Of Rising Main. 21 Fabrication Of Gravel Hooper For Proper Feeding Of Gravels To The Borewell Andplatform To Bear The Load Of Pumping Unit, Column Pipes Etc By Way Of Providing And Fitting Of Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. The Job Involves Following Steel Details:I. In Stringers, Treads, Landings Etc Of Stair Cases Including Use Of Chequered Plate Wherever Required, All Complete 22 Ii. In Grating, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 23 Providing And Fitting Ofm.S 4 Inch Hinges -6 No And M.S Handle Heavy -8No., Anchor Bolts With Nuts ( M16 ) Of 0.3 M Long = 04 No. Metallic Strip ( 350Mm×50Mm×3Mm ) = 02 No. 24 Fabrication Of Gantry Mechanism / Cgi Shedby Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 25 Providing, Installation Andtestingof Manual Type Triple Spur Gearchain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features. Gears:- The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mounted On Bearings And Housed In A Dust Proof Gear Box. The Lubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears.Load Chain:-The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility. The Chain Should Be Accurately Collaborated, Tested And Have Adequate In Built Factor Of Safety For Safer Operation.Load Chain Wheel:- The Load Chain Well Should Be Double Ball Bearing Supported Andspecially Designed, Perfectly Machined Wheel Providing Correct Grip Of Load Chaintomakes The Hoist Most Safe And Reliable Against Any Failure. The Main Specifications Of C.P Block Are Given Below : Make = Reputed Makecapacity=3Ton No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 M 26 Creation Of Pope Mounted, Outdoor Type Electric Sub Stationby Way Ofs / I / T / C Of 11 / 0.433 Kva, 3 Phase Distribution Transformer With Bimetallic Terminal Connectors Energy Level -2 Aluminum Woundspecifications Conforming To Is : 1180 ( Part 1 ) 2014 With Latest Amendments Type Of Cooling:Onan.The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved.The Ht Transformer Shall Be Of Reputed Make From An Iso Certified Company As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Be Provided With Breather Fill With Silica Jel Crystals , Conservator With Oil Level Indicator , Explosion Vet And Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is:1180 ( Part 1 ) 2014 With Latest Amendments.Note: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificaterating: 100 Kva Ht Transformer, 3 Phase ( Level 2 ) . 27 Providing And Fittingg.I Channel / Angle / Flat Of Sizes Including Clamps 28 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Ofht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 29 Supply, Installation, Testing And Commissioning Of 11Kvpolymer Fuses Sethorn Gap3-Phase 200 Asuitable For Vertical Installation . 30 Supply, Installation, Testing And Commissioning Ofgapless Surgearrestor Station Class, 10Ka, 9Kv, La With Polymer Housing , Station Type . 31 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative, Creepagedistance 320 Mm 32 Supply, Installation, Errection Of9 Mtrs Long H.T Pole Of Specifications St- 410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories .Wherever Required. The Job Further Includes Gi Wire Earthing Of Pole As Per Rec Standard. 33 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement. 34 P / F Danger Plate With Clamps 35 Providing And Fixing G.I Barbed Wire For Anti Climbing 36 Providing And Fixing Of Anti Climbing Devices With Clamps 37 Painting Of Poles Red Oxide 38 Painting Of Poles Aluminum Paint 39 Providing And Fitting Of Acsr As Per Is 398 ( Part-2 ) 1996 For 50 Sq.Mmacsr ( Galvanised Steel Reinforced ) For Fitment Of Various Accessories 40 Supply, Installation And Testing Of 35 Sq Mm Xlpe Aluminum H.Tcable ( Abc Type ) Of 11 Kv Grade With Following Specs.Size ( Cross Sectional Area In Sq Mm ) =3×35 With Reinforced Wirephases:Red, Yellow, Blue 41 Providing And Fitting Of Anchoring Clampscomprising Clamp Body, Plastic Wedge, Steel Bill Bracket, Straps And Buckles Or Nuts And Bolts Required For Holding Of 3 – Core , 35 Sq. Mm H.T Ab Cable. 42 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And 100 Kva Ht Transformer. 43 Fabrication, Providing And Fitting Ofmu-G 75 Modularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories As Under:A ) Busbar Chamber:Complete Specifications As Per Cluase- 43-H Of Sbd 44 Providing, Fitting, Testing And Commissioning Ofvoltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step.Type Of Regulator: Double Plate Type With Electrolytic Copper Contacts.Rest Specification As Per Cluase- 44 Of Sbdrating:: 75Kva 45 Providing And Fitting Of 3-Core Flatsubmersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipments . The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. Size: 25 Sq.Mm 46 Providing And Fitting Of 3 / 3.5 / 2-Core, Xlpe Armoured Aluminium Cable Conforming To Is: 7089 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Note:- The Cable Terminal Ends For Connection To Switchgear At Various Requisite Points Shall Be Al. Thimbles Of Dowel’S Make And Of Appropriate Size And Connected By Hydraulic Crimp Tool Only.I ) 50 Sqmm, 3.5Core, Lt, 1.1 Kv 47 Ii ) 10 Sqmm, 2 Core, Lt, 1.1 Kv 48 P / I Of Earthing Station For Substation, Lt Panel, Dg Set And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size:80 Mm Dia , Length :2000 Mmback Fill Compound :30 Kg 49 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is:15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . The Co2 Extinguisher Should Be Suitable For Class B & C Fire And Also For Fire Involving Electrical Equipments. The Cylinder Used For Fire Extinguisher Shall Be Approved By Protroleum Andexplosive Safety Organization ( Peso ) As Per Gas Cylinder Rules 2004 And As Per Is: 7285 Of 2004. The Body Should Be Made Of Seamless Steel ( Manganese ) Confirming To Is:7285 With Is Mark And Should Be Provided With Squeeze Grip Nozzle And Should Be Filled With Co2 Confirming To Is : 15222 Of 2002 With Certificate.The Extinguisher Shall Be Provided With Manufactures Test Certificate And Hydraulic Test Certificate By Bis From Peso. 50 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp. The Job Includes Fabrication, Providing And Fitting Of Three Arm Gi Structure At The Top Having 120° Angle Between Arms And Each Arm Having 15° Inclination With Respect To Horizontal Plane. Each Arm Should Be Of 2’ Length And Size And Shape Appropriate As Per Requirement Of The Luminary.The Job Also Includes Providing And Fitting Of Required Length Of Flexible Multi Strand 2 Mm Copper Wire From Each Terminal Connector To Each Holding Arm.The Pole Is To Be Mounted On 1:2:4 Cement Concreting Of Size Not Less Than 2’X2’X6” ( Cost Of Concreting Not Included In The Job ) Using 04 No Anchor Bolts Of Required Size Not Less Than 7” In Length. The Complete Job Includes Earthing In Gi Electrode As Per Relevant Is Code. 51 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C To 60°Cthe Led Is Pressure Die Cast Aluminum Housing With Power Coated Finish And Having Ingress Protection Up To Ip-68.The Led Is To Be Properly Fitted On The Arm Of The Pole And Connected To The Copper Wire As Directed. 52 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site Incharge. 53 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter ( Make: Reputed ) Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. ( Make: Reputed ) With 2-Core 6Mm2 Cu Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 54 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 55 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below Shall Be Of :Providing Of Tool Kit Consists Of Following Items I. Double Ended Spanner ( Chrome Plated ) Of Size In Mm6 / 7, 8 / 9, 10 / 11, 12 / 13, 14 / 15, 16 / 17, 18 / 19, 20 / 22, 21 / 23, 24 / 26, 25 / 28, 24 / 27, 30 / 32 Each – 02 No.Rest Specifications And Quantity As Per Clause-56 Of Sbd 56 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos Including Cutting , Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 57 Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’S Rest Specifications And Quantity As Per Clause-57 Of Sbd 58 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 59 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 60 Providing Of 1 Kw Heat Convector For Operators For Winter Season. 61 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metal Showing The Names Of Water Supply Scheme And The Department. Size:6’×1’6” 62 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. 63 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks , Bolts And Nuts 8 Mm Dia. Diameter With Bitumen And G.I Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Upto Any Pitch In Horizontal / Vertical Or Curved Surface ) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.0.50 Mm Thick With Zinc Coating Not Less Than 275 Gram / M2 64 Providing, Cutting , Fittingand Welding Green Pvc Coated Welded Wire Fencewith Squaremesh -4And Wire Diameter 1.5 Mmto Be Fitted Onall Openverticalsides Of The D.G Set Shed . The Job Includes Cutting, Welding, Hoisting Etc As Per Site Requirement. 65 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase Diesel Generator Set As Per Is 8528 ( 2018 ) And Iso 3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size As Per Ministry Of Environment Protection Rule 1986 Read With Latest Amendments. The Dg Set Is Required To Be Fitted And Tested On Load At Sitethe D.G Set Shall Have The Following Technical Specification.Besides The Above Works The D.G Set Shall Be Provided With 12 V, 150 Ah Lead Acid Battery Of Reputed Make Fitted Inside The D.G Set Canapy Along With Necessary Accessories And Battery Charger Of Required Capacity. The Job Also Includes The Cost On Account Of Hsd And Skilled Operator Required For Operation Of D.G Set For A Period Of 10 Hours Continuously During Its Testing And Commissioning Of D.G Set At Site. The Capacity Of The D.G Set Is Given Below:I. Capacity Of D.G Set = 62.5Kva , Watercooled 66 Providing, Installation, Testing & Commissioning Of Complete Switchgear Unit For Protection Of D.G Setconsisting Of 200A Mccb 3- Pole , 415 V, 50 Kv Breaking Capacity Housed Properly In Cubical Enclosure Made Upof M.S Swg – 16 Sheet Steel ( Outdoor Type ) Duly Powder Paintedwith Anti Corrosive Paint Comprising Of Three Compartments For Incoming / Out Going Circuits And Mccb. The Panel Should Have Adequate Double Locking Arrangement With Cu-. Bus Bar 12X40 Mm With Bakelite Insulation And Lt Arrangement Selector Switches, Phase Indicators. The Equipment Should Be Installed At Appropriate Height In A Stand Consisting Of 50 X 50 X 6 Mm Angle Grouted In Ground With Appropriate Cement Bottoming As Per The Is Standard.The Work Is To Executed Near D.G Set At Site 67 Carriage Of Sand , Stone Aggregate By Mechanical Transportincluding Loading , Unloadingand Stacking ( Average Distance-5Km ) 68 Carriage Of Soling Stone By Mechanical Transportincluding Loading , Unloadingand Stacking ( Average Distance-5Km ) 69 Carriage Of Cement / Steel / Cgi Sheet / Gi Pipes Below 100Mm Dia And Other Heavy Materials By Mechanicaltransportincluding Loading , Unloadingand Stacking ( Average Distance -25Km )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-May-2023 Extension Notice Date 10-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 120100.0 /-
Tender Value
INR 60.05 Lakhs /-

BOQ Items

Name of Work:Supply, Installation, Testing and Commissioning of Electro-Mechanical equipments at water supply scheme Khan Basti Chukpora of Jal Shakti (PHE) Mechanical Division South Awantipora under JJM.
Sl. No. Item Description
1Electro-Mechanical Items of WSS Khan Basti Chukpora
2Supply, Installation, Testing & Commissioning of Submersible Pumping Unitas per IS 8034 with following specification are as under : PUMP : Efficiency= Not less than 50% Speed = 2900 Rpm Discharge= 7000 GPH Head = 150 Mtr Type of pump = Mixed flow. Type of fluid to be handled = Clear Water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel Pump Shaft = Stainless Steel SS 410. Pump Casing= Cast Iron/Stainless steel Motor capacity= Not Less than 30 HP IMPELLER: Rest specifications as per cluase - 1 of SBD
3Fabrication, providing, fitting and lowering ofcolumn pipe conforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia. production well up to the desired depth ; The job includes Providing and welding of flanges conforming toIS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 no. rectangular cable slots in each flange. Size: DN 80 Class: C (Heavy)
4Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:1363 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The rising main is to be laid as per the instructions of the engineer in charge and site requirement. Size : DN 100 Class: B (Medium)
5Earth work in excavation by manual means in trenches for foundation, drains, pipes, cables (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and reaming of bottom lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed. (All kinds of soil 01 meter from cutting edge)
6Filling available excavated earth in trenches, plinth, sides of foundation etc.in layers not exceeding 20 cm in depth , consolidating each deposited layer by reaming and watering , lead upto 50 m and lift upto 1.5m.
7Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materialin all kinds of soil
8Providing and laying of stone soling including manual compaction
9Centering and shuttering including strutting , propping etc. and removal of form work for Foundation , footings , bases for columns
10Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering . all work upto plinth level with 1: 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20mm nominal size)
11Providing and laying in position cement concrete of specified grade of reinforcement cement concreteincluding curing but excluding the cost of centring and shuttering. finishing and reinforcement all work upto plinth level with 1: 1.5 : 3mix (1 cement , 1.5 coarse sand , 4 graded stone aggregate 20mm nominal size)
1212 mm thick cement plaster of mix 1:4( 1 cement , 4 fine sand )
13Steel reinforcement for RCC work including straightening, cutting, bending, placinng in position and binding all complete upto plinth level Thermomechanically treated bars of grage FE-500D or more
14Fabrication, providing and fitting of split type MS clamps10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size: 80mm
15Fabrication, Providing and fitting of90-120 degree bend/elbowto be fabricated out ofG.I pipe, 1 m lengthand flanged on both ends ato make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement. Size:DN 100 Class: C
16Cutting of hot dip galvanized G.I,pipe across the section by dint of pipe cutter/ gas cutter. The job also includes Providing and welding of M.S flanges to the two ends of pipe. The Thickness of flange shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using Advani/Esab/L&T- SS Bond make electrodes to form strong welding joint by dint of DC arc welding. The job further includes Providing and Fitting of nuts and bolts (conforming to IS:1363 Part 1st) and Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The size of the pipe isDN 100 , Class-C
17Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. Size: 100mm Class: C class
18Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . The body and bonnent of the valve shall be of ductileiron, wedge with fully vulcanized EPDM rubber(Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating(approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. Size: DN100 PN:1.6/16
19Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber(Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. Size: 100 mm PN: 1.6/16
20Providing, fitting, testing and commissioning of50mm diameter ARV (Air Release valve) as per IS 14845 to be fitted toG.Irising Main. The ARV Shall have the following specifications: i. Valve type -single chamber, single orifice. ii. End connection-flanged ends to IS 1538 iii. Working temperature- 20?C to 45?C iv. Test pressure - body / seat 2.5 x PN v. Sealing ring -EPDM vi. Construction-ductile iron with stainless steelfloats vii. Coating -epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. The job also includes cutting of 50 mm dia hole in rising main and P/F of50mm dia.M.S Pipe one feet long with one end flanged perfectly adaptable to Flange of ARV and other end welded to 50 mm dia hole of rising main.
21Fabrication of gravel Hooper for proper feeding of gravels to the borewell andplatform to bear the load of pumping unit, column pipes etc by way of providing and fitting of Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. The job involves following steel details: i. In stringers, treads, landings etc of stair cases including use of chequered plate wherever required, all complete
22ii. In grating, frames, guard bar, ladder, railings, brackets, gates and similar works
23Providing and fitting ofM.S 4 inch hinges -6 no and M.S handle heavy -8no., Anchor bolts with nuts (M16) of 0.3 m long = 04 No. Metallic strip (350mm×50mm×3mm) = 02 No.
24Fabrication of gantry mechanism/CGI Shedby way of providing Structural steel in built up sections , trusses and framed work, including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer all complete welded
25Providing, installation andtestingof manual type triple spur gearchain pulley block along with monorail gearedtravelling trolleyhaving following features . Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:-The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- the load chain well should be double ball bearing supported andSpecially designed, perfectly machined wheel providing correct grip of load chaintomakes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Make = Reputed make Capacity=3ton No. Of load chain falls = 2 or above Min. Height of lift = 6 M
26Creation of pope mounted, outdoor type Electric Sub Stationby way ofS/I/T/C of 11/0.433 KVA, 3 Phase Distribution Transformer with Bimetallic Terminal connectors Energy level -2 Aluminum wound Specifications conforming to IS : 1180 (Part 1) 2014 with latest amendments Type of cooling:ONAN. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage,and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals , conservator with oil level indicator , explosion vet and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS:1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. The testing and commissioning shall be completed only after obtaining above certificate Rating: 100 KVA HT Transformer, 3 phase (Level 2).
27Providing and fittingG.I Channel /Angle/ Flat of sizes including clamps
28Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs.
29Supply, Installation, Testing and commissioning of 11KVpolymer fuses SetHorn Gap3-phase 200 Asuitable for vertical installation .
30Supply, Installation, Testing and commissioning ofGapless Surgearrestor station class, 10KA, 9KV, LA With polymer housing , Station Type .
31Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative, creepagedistance 320 mm
32Supply, installation, errection of9 mtrs long H.T pole of specifications ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories .wherever required. The job further includes GI wire earthing of pole as per REC standard.
33P/F of Galvanized nuts, bolts of various sizes as per site requirement.
34P/F Danger Plate with clamps
35Providing and fixing G.I Barbed wire for anti climbing
36Providing and fixing of anti climbing devices with clamps
37Painting of poles Red oxide
38Painting of poles Aluminum paint
39Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories
40Supply, Installation and Testing of 35 Sq mm XLPE Aluminum H.Tcable (ABC type ) of 11 KV grade with following specs. Size (cross sectional area in sq mm)=3×35 with reinforced wire Phases:Red, Yellow, Blue
41Providing and fitting of Anchoring clampscomprising clamp body, plastic wedge, steel bill bracket, straps and buckles or nuts and bolts required for holding of 3 – Core , 35 Sq. mm H.T AB Cable.
42P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and 100 KVA HT transformer.
43Fabrication, Providing and fitting ofMU-G 75 Modularmotor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class : IP-55 & fitted with accessories as under: a) Busbar Chamber: Complete specifications as per cluase- 43-H of SBD
44Providing, fitting, testing and commissioning ofvoltage stabilizeras per specifications below: Type of voltage controller: Manually operated copper wound, 3-phase, AC power supply multi step. Type of Regulator: Double plate type with electrolytic copper contacts. Rest specification as per cluase- 44 of SBD Rating:: 75KVA
45Providing and fitting of 3-Core flatsubmersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipments . The cable connections terminal shall be fitted with copper thimbles of required size. Size: 25 sq.mm
46Providing and Fitting of 3 /3.5/2-Core, XLPE Armoured Aluminium Cable conforming to IS: 7089 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. NOTE:- The cable terminal ends for connection to switchgear at various requisite points shall be Al. Thimbles of dowel’s make and of appropriate size and connected by hydraulic crimp tool only. i) 50 sqmm, 3.5core, LT, 1.1 KV
47ii) 10 sqmm, 2 core, LT, 1.1 KV
48P/I of earthing station for substation, LT panel, DG set and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size:80 mm dia , Length :2000 mm Back fill compound :30 kg
49Supply, installation of 6 kg co2 type fire extinguisher manufactured as per IS:15683 OF 2006 with IS mark and comply with DGMS(Approval) . The co2 extinguisher should be suitable for class B & C fire and also for fire involving electrical equipments. the cylinder used for fire extinguisher shall be approved by protroleum andexplosive safety organization(PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS:7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS : 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO.
50Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structure at the top having 120° angle between arms and each arm having 15° inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is to be mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” ( cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code.
51Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole vide item No.36 Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C to 60°C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is to be properly fitted on the arm of the pole and connected to the copper wire as directed.
52Providing, Installation and testing of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site incharge.
53Supply, installation, Testing & commissioning of 1000VA Full Sine wave power inverter (Make: Reputed) including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. (Make: Reputed) with 2-core 6mm2 Cu wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.
54Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate.
55TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of : Providing of tool kit consists of following items i. Double ended Spanner(Chrome plated)of size in mm 6/7,8/9,10/11,12/13,14/15,16/17,18/19,20/22,21/23,24/26,25/28, 24/27, 30/32 each – 02 no. rest specifications and quantity as per clause-56 of SBD
56Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos including cutting , fixingall complete including painting of the play sheet by one coat of primer and two coats of enamel paint
57Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6"x3" (6Kg)- 02 No’s ii) Quilt with warm cover size 5"x8" (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s rest specifications and quantity as per clause-57 of SBD
58Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply.
59Providing of bamboo ladders 18 feet long along with 15 feet long Link rods and HT Glove pair (01 No each)
60Providing of 1 KW heat convector for operators for winter season.
61Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metal showing the names of water supply scheme and the Department. Size:6’×1’6”
62Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site.
63Providing corrugated G.S Sheet roofing including vertical/ curved surface fixed with polymer coated J or L Hooks , bolts and nuts 8 mm dia. diameter with bitumen and G.I limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( upto any pitch in horizontal /vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2
64Providing, cutting ,fittingand welding Green PVC Coated welded wire fencewith Squaremesh -4and wire diameter 1.5 mmto be fitted onall openverticalsides of the D.G Set shed . The job includes cutting, welding, hoisting etc as per site requirement.
65Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase Diesel Generator set as per IS 8528 (2018) and ISO 3046 (2002) for engine and IEC/IS 60034-1 for alternator suitably assembled and fitted in a pollution free acoustic enclosure / canopy of required size as per Ministry of Environment protection rule 1986 read with latest amendments. The DG Set is required to be fitted and tested on load at siteThe D.G Set shall have the following technical specification. Besides the above works the D.G set shall be provided with 12 V, 150 AH Lead acid battery of reputed make fitted inside the D.G set Canapy along with necessary accessories and battery charger of required capacity. The job also includes the cost on account of HSD and skilled operator required for operation of D.G set for a period of 10 hours continuously during its testing and commissioning of D.G set at site. the capacity of the D.G set is given below: i. capacity of D.G set = 62.5KVA , watercooled
66Providing, Installation, Testing & Commissioning of complete switchgear unit for protection of D.G Setconsisting of 200A MCCB 3- pole , 415 V, 50 KV breaking capacity housed properly in cubical enclosure made upof M.S SWG – 16 sheet steel (outdoor type)duly powder paintedwith anti corrosive paint comprising of three compartments for incoming / out going circuits and MCCB. The panel should have adequate double locking Arrangement with Cu-. Bus Bar 12x40 mm with Bakelite insulation and LT Arrangement selector switches, phase indicators. The equipment should be installed at appropriate height in a stand consisting of 50 x 50 x 6 mm angle grouted in ground with appropriate cement bottoming as per the IS standard.The work is to executed near D.G SET at site
67Carriage of sand , stone aggregate by mechanical transportincluding loading , unloadingand stacking (average distance-5km)
68Carriage of soling stone by mechanical transportincluding loading , unloadingand stacking (average distance-5km)
69Carriage of cement/steel/CGI sheet/GI pipes below 100mm dia and other heavy materials by mechanicaltransportincluding loading , unloadingand stacking (average distance -25Km)