Panjab University has published Tender For Provision Of Ahu System In Dinning Hall For Girls Hostel No-1 In P.U Campus Sector-14 Chandigarh. Submission Date for this Tender is 27-04-2023. Air Handling Unit Tenders in Chandigarh Punjab. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (DSR 1.17) |
2 | 1 x 1.5 sq. Mm(DSR 1.17.1) |
3 | 2 x 4 sq. Mm (DSR 1.17.20) |
4 | 2 x 6 sq. Mm (DSR 1.17.29) |
5 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. (DSR 2.16) |
6 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required. (DSR 2.17) |
7 | S/E of 2 core 1.5sq.mm PVC insulated flexible copper wire in the existing surface/ recessed steel/ PVC conduit/ Batton etc. Complete in all respect to the entire satisfaction of EIC. |
8 | S/E of 2 core 1.0sq.mm PVC insulated flexible copper wire in the existing surface/ recessed steel/ PVC conduit/ Batton etc. Complete in all respect to the entire satisfaction of EIC. |
9 | Providing & fixing in position food grade double layer polyethylene PVC water storage tank with cover & suitable locking arrangement including necessary holes forinlet, outlet, overflow pipes. The work includes tank based support of 9" brick work (height of base as per site) in any form and base filled with sand, final top layer with 25mm thick concrete of 1:2:4 ratio duly plastered with 12mm thickness all around the tank including cement coating. Complete including the necessary G.I fittings/ Tank nipple of required size to tank in all respect to the entire satisfaction to the EIC. |
10 | Supply,installation,testingandcommissioningofDouble skinconstructionairwasherunitconsistingof followingDIDW class-I centrifugal fan (Efficiency > 75%), TEFC weather proofmotor of IP55 protection at 415±10%volts,3phase,50cycles 7.5 HPpowerand IE02 highefficiency,beltdrive,multisheavepulleymountedon motor and fan shaft , motor and fan mounted on common base with vibration isolators. Fan blower capacityshallbebasedonoutletvelocitynotexceeding550FPM, 710 Dia X 1 No. DIDW farward curved, Taper lock pulley, Air Washer. Total static pressure shall be checked by Vendor based on ducting layout. |
11 | Cellulose fill air washer, giving 95% efficiency at 500 FPM air velocity acrosspads, factory assembled and complete with casing 1.2 mm thick SS-304 water tank, Cellulose fill 200 mm thick, water distribution header,ballvalvesandnecessary fittings. Pre filters at suction, 32sft. Al. filter with aluminium frame having 20 micron filter and Aluminium wiremesh (Min 5 layers) Efficiency 80% down to 20 microns, water tank constructed in 1.2mm thick SS-304 Grade |
12 | 1 No. horizontalmonoblocpumps min 0.5 HP of factorymountedwith electric motor for circulationof water. Pumps shallbe aligned and suitablefor 215±10% volts, 50 cycle’s 1 phase power supply. It includes the cost of MS stand for Airwasher units, made of MS CHANNEL 75x75x6 size with working platform all around duly painted with synthetic enamel paint |
13 | Air Washer unit described as above & suitable for following air moving capacity. 15000 CFM, STATIC PRESSURE 40MM WC |
14 | Supply,Installation, testing & commissioning of sheet metal leak proof ducting complete with necessary angle /channel supports,hangers, nuts,bolts,anchor fastners ,washers, rubber gaskets etc., GI body heavy guage manual volume control dampers, vanes, etc. as per specifications and drawings.All ducting of any sizeshould be flanged type and no slip joints will be allowed.All joints , corners of the ducting to be applied with silicon sealant for leak proof joints.Cost of smoke testing of the ductingas per specification/site instruction is to be included . |
15 | 22 Gauge |
16 | Supply & installation of Single Louver Extruded aluminium Powder coated grill for Supply air. |
17 | Supply and erection of XLPE insulation with Aluminum foil insulation used withadhesive SR 505 fevicol |
18 | 23 ± 2mm thick |
19 | Supply,installation,testing and commissioning of fire retardant nonporous double layer flexible connection between Airwsher & duct (Canvass Connection) |
20 | Electrical Control Panel body withMs Sheet metalhaving ( 16 Gauge )withpowder coated , included OLR , Single Phase Perventer,LED light for indication,Push button for ON/OFF, Three phase TPN for Water circulation pump , Main incomer MCB proper rated Contactor (ELECTRICAL CONTROL PANEL) |
21 | Providing &fixing control cumtransmission wiring of 4 core x 4 sqmm copper in suitable conduits between Electrical panel to AIRWASHER (Control & Transmission Wiring) |
22 | S/T/C/L of 16 Sqmm 4 core PVC insulated and PVC sheathed/XLPE Aluminium power cable of 11 KV grade to be laid and fixed on wall surface Clamped with 1mm thick Saddle . Confirming to 7.7.1 DSR Complete in all respect to the satisfaction of E.I.C |
23 | Supply & erction of "B" class GI pipe 25mm2 on surface with suitable size clamps/ hooks for holding the GI Pipe, complete in all respect to the entire satisfaction of EIC. |
24 | Supply & erction of GM peet valve of size 25mm2 , complete in all respect to the entire satisfaction of EIC. |
25 | Supply & erction of GI union of size 25mm2 , complete in all respect to the entire satisfaction of EIC. |
26 | Supply & erction of Ball cock of size 25mm2 , complete in all respect to the entire satisfaction of EIC. |