Tender For Repair/ Replacement To Internal Electrical Including Summer Appliances, Fans, Light, Fittings And Fixtures And All Connected Items Omqs And Otms At Hqtc Bangalore, bangalore-Karnataka

Military Engineer Services-MES has published Tender For Repair/ Replacement To Internal Electrical Including Summer Appliances, Fans, Light, Fittings And Fixtures And All Connected Items Omqs And Otms At Hqtc Bangalore. Submission Date for this Tender is 11-05-2023. Air Conditioner Tenders in bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

37224559
Corrigendum : Tender For Repair/ Replacement To Internal Electrical Including Summer Appliances, Fans, Light, Fittings And Fixtures And All Connected Items Omqs And Otms At Hqtc Bangalore
Open Tender
Indian
Karnataka
bangalore
11-05-2023

Tender Details

Repair/ Replacement To Internal Electrical Including Summer Appliances, Fans, Light, Fittings And Fixtures And All Connected Items Omqs And Otms At Hqtc Bangalore

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Apr-2023 BOQ and Tender Corrigendum BOQ 04-05-2023
2 04-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR/ REPLACEMENT TO INTERNAL ELECTRICAL INCLUDING SUMMER APPLIANCES, FANS, LIGHT, FITTINGS AND FIXTURES AND ALL CONNECTED ITEMS OMQs AND OTMs at HQTC BANGALORE.
Sl. No. Item Description
1Material & Labour Servicing of defective solar water heater 100 litres capacity with electric back up system after disconnecting the existing water supply/ electrical connections from any height of the building,including stripping out the hot water vessel by taking out the outer cover, insulating materials etc. and continuous brazing of the inner container for arresting leakages including replacement of defective / worn out spare parts and re-assembling the system and re-installed at the same location, connecting up water/ electrical connections and testing for satisfactory performance complete all as specified and as directed.
2All as per item No 1 above but for 200 litres capacity
3All as per item No 2 above but for 300 litres capacity
4Supply and fixin repair back up kit of solar water heater upto3 KW complete all as directed.
5Supply and fix in repair5mm thick toughened plain glass panels suitable for solar water heater plate collector box,suitable for existing make all as specified and as directed.
6Supply and fix in repairHeating element 1.50 KW with rubber gasket threaded/ push type 230V for Geyser, ISI Marked all as specified and as directed. Make: Theeta/RacoldISI Marked
7Supply and fix in repairHeating element 2.00 KW with rubber gasket threaded/ push type 230V for Geyser, ISI Marked all as specified and as directed. Make: Theeta/RacoldISI Marked
8Supply and fix in repairHeating element 3.00 KW with rubber gasket threaded/ push type 230V for Geyser, ISI Marked all as specified and as directed. Make: Theeta/RacoldISI Marked
9M&L for cleaning of solar tank 100 by providing chemical & removing all scale / dirt / dust etc disconnecting the existing water supply/ electrical connections from any height of the building,connecting up water/ electrical connections and testing for satisfactory performance complete all as specified and as directed.
10All as per item No 165 above but 200 ltrs capacity
11All as per item No 165 above but 300 ltrs capacity
12Supply and fixM sealphataohat packing size 25 gram each pkt
13Supply and fix matel paste each paking in 500 grams.
14Supply and fix in repair of copper flexible cable 3 core 2.5 sqmm PVC FRLS insulated and sheathed 1100 volts grade.Make: Havells Anchor/Finolex etc.
15Supply and fix in repairthermostat suitable for solar water heaterall as directed .
16Material & Labour for Taking down &Refixing only geyser 50/25 ltrs capacity after repairs in new position including drilling holes on wall ,fixing four Nos anchor bolts,nuts and washersand connecting to the water and electric connections and testingcomplete all as directed.
17Servicing of storage type electric water heater (geyser) of capacity 15 /25 litres comprising of the following works: - (i) Taking down geysers from existing positionafter disconnecting all electrical & water supply connection. (ii) Opening / dismantling & cleaning of all parts & checking for its serviceability. (iii) Cleaning / descaling of thermostat & inner tank with descaling solution & water leakage testing of tank & rectification of leakage. (iv) Checking of pressure reducing valves & non return valve etc. to ensures free movement / smooth operation of these components. (v) Checking of overflow / vent pipes and removing blockages / obstructions if any. (v) Reassembling the geyser, replacement of minor spare part such as nut, bolt, screw, rubber packing etc & refixing in same position, reconnecting with electric & water supply connection complete all as specified and as directed.
18Supply and fix in repairHeating element 1.50 KW with rubber gasket threaded/ push type 230V for solar water heater, ISI Marked all as specified and as directed. Make: BAJAJ/ USHA ISI Marked
19Supply and fix in repairHeating element 2.00 KW with rubber gasket threaded/ push type 230V for solar water heater, ISI Marked all as specified and as directed. Make: BAJAJ/ USHA ISI Marked
20Supply and fix in repair safety valve / high pressure valve ISI marked suitable for geyser of any capacity.
21Supply and fix in repair storage tank made out of copper sheet suitable for 25 litres capacity geysers.
22Supply and fix in repairthermostat suitable for geysers 25 to 50 ltr capacity and range 30 to 80 degree centigrade and cut off at 70 degree centigrade all as directed .
23Supply and fixin repair ofPVC connection pipe 15mm dia450mm long heavy duty for hot /cold water with two brass union and washers complete all as directed.
24Supply and fixin repair ofPVC connection pipe 15mm dia600 mm long heavy duty for hot /cold water with two brass union and washers complete all as directed.
25Supply and fix in repair indicator lamp square/ round / rectangular type suitable for geysers of 25 to 50 Ltr capacity.
26Supply and fix inner assebmly 25 ltrs geyser and connecting to the water and electric connections and testingcomplete all as directed.
27Supply and fix MCB sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 A , 240 Volts .
28Supply and Fixing in repairs Modular Switch socket combination6 pin,16 amps multi purpose, 3 modulecomplete all as specified and directed
29Supply and Fixing in repairs of Switch socket combination 5 in 1, 3 pin 5 and 16 amps multi purpose flush typeuniversal, with indicator complete all as specified and directed.
30Supply and Fixing in repairs of MCB SP, 6-40 Amps, 240V,
31Supply and Fixing in repairs of MCB SPN, 40 Amps, 240V,
32Suppy and laying of CPVC pipe SDR 11 plain SDR CPVC SDR Fittings of size 20 mm outer dia with all fittings on walls /ceiling/floors complete all as specifide and directed.
33Suppy and laying of CPVC pipe SDR 11 plain SDR CPVC SDR Fittings of size 16 mm outer dia with all fittings on walls /ceiling/floors complete all as specifide and directed.
34Supply & Fixing in repair 15 MM Bib Taps, Cast copper alloy with crutch or butterfly handle, Screwed down screwed for iron pipe or for brass ferrule fancy type and fixed.
35Supply & Fixing in repair 20 MM Bib Taps, Cast copper alloy with crutch or butterfly handle, Screwed down screwed for iron pipe or for brass ferrule fancy type and fixed.
36Supply & Fixing in repair Stop Cock/ Stop valves, 15 mm diaCast copper alloy screw down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed.
37Supply & Fixing in repair Stop Cock/ Stop valves, 20 mm diaCast copper alloy screw down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions & fixed.
38Taking down CPVC pipe SDR 11, 20 mm outer dia with all fittings.
39Taking down CPVC pipe SDR 11, 15mm outer dia with all fittings.
40Taking down and connecting the electric metersfrom meter board and refixing the same including connecting up andprovision of cableall as specified and directed.
41Servicing/ overhauling of Electric energy meters of any size/ any capacity including testing of meters for running properly and accuracy including load testing with proper equipments
42Supply &fixing ofin repairs stepped type electronic fan regulator flush type with 5 step speed control complete all as specified and directed
43Supply and fixing of modular white cover plate with frame, 1 module
44Supply and fixing of modular white cover plate with frame, 2 module
45Supply and fixing of modular white cover plate with frame, 3 module
46Supply and fixing of modular white cover plate with frame, 4 module
47Supply and fixing of modular white cover plate with frame, 6 module
48Supply and fixing of modular white cover plate with frame, 8 module
49Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 2.50sqmm in and including non-metallic rigid PVC casing and capping andaccessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 1.50 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed.Note : One run of earth continuity conductor,one run of PVC casing cappingand two run of copper conductor together taken as one length for measuring unit length.
50Sub main wiring with Two single core PVC insulated FRLS cable with copper conductor multistranded 1100 volts grade 4.00sqmm in and including non-metallic rigid PVC casing and capping andaccessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including2.50 sqmm PVC insulated FRLS multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed.Note : One run of earth continuity conductor,one run of PVC casing cappingand two run of copper conductor together taken as one length for measuring unit length.
51Supply and fixing ofin repairsCeiling Fan capacitors 1.5 mfd all as specified and directed
52Supply and fixing ofin repairsCeiling Fan capacitors 2.5 mfd all as specified and directed
53Supply and fixing ofin repairs down rod 4 feet length suitable for ceiling fans all as specified and directed
54Supply and fixing ofin repairs down rod 2 feet length suitable for ceiling fans all as specified and directed
55Supply and Fixing in repair Fan Regulater 120 W , 2 module
56Supply and fixing the Power unit with 16 amps AC & Geyser, 3 Module, Make : INDO ASIAN, CAT NO : 800125 or Equivalent in ANCHOR/ HAVELLS/ PHILIPS
57Supply and fixing the Power unit with 20 amps with MCB & PLUG, 3 Module, Make : INDO ASIAN, CAT NO : 800193 or Equivalent in ANCHOR/ HAVELLS/ PHILIPS
58Supply and fix in repair of plug top 3 pin 16 amps, 3 Pin Plug, 230 volts.
59Supply and fix in repair of plug top 3 pin 6 amps, 3 Pin Plug, 230 volts.
60Supply and fixing ofin repairsExhaust Fan capacitors 2.5 mfd all as specified and directed
61Supply and fixing ofin repairs LED High Wattage Lamps 30 Watts, Make BAJAJ, Model : CORONA LED, CAT NO 830108 or equivalent in HAVELLS/ PHILPS/ WIPRO /CGall as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail