|
| 1 | Excavating pits in any type of soil including plantation of shrubs/saplings and trees of selected species by refilling the pits with approved fertile soil mixed with available excavated soil and manure (compost/cattle dung) in the ratio (2:2:1) dosing refilled pits with antitermite treatment using chloropyrophos 50%EC @ 100ml per cum,watering and removal of surplus excavated spoil to a distance exc 50m but n. exc 250m depositing etc complete including bringing up the plantation properly all as specified and directed for following pit sizes:-NOTE:-(a) Fertile soil, manure (compost/cattle dung), anti-termitechemical shall be measured and paid for separately as supply only under respective items of this schedule.(b) Tree, shrubs/sapling for plantation shall be measured and paid for separately under relevant items of this schedule. |
| 2 | Pit size 90cm x 90cm x 90cm |
| 3 | Pit size 60cm x 60cm x 60cm |
| 4 | Excavating in trenches of size 30cmx30cm and 30cm deep in any type of soil including plantation of shrubs/saplings/hedges of selected species by refilling the pits with approved fertile soil mixed with available excavated soil and manure (compost/cattle dung) in the ratio (2:2:1) dosing refilled pits with antitermite treatment using chloropyrophos 50%EC @ 100mm per cum,watering and removal of surplus excavated spoil to a distance exc 50m but n. exc 250m depositing etc complete including bringing up the plantation properly all as specified and directedNOTE:-(a) Fertile soil, manure (compost/cattle dung), chemical for antitermite treatment shall be measured and paid for separately as supply only under respective items of this schedule.(b) Shrubs/saplings/Hedges for plantation of selected species shall be measured and paid for separately items of this schedule. |
| 5 | Digging of earth upto 0.30m depth and removal of surplus excavated spoil to a distance exc 50m but n. exc 250m,preparation of soil/ground by uprooting grass, vegetation etc removing boulders,pebbles etc and levelling the surface flat or in slope complete all as specified and directed. |
| 6 | Laying only fertile soil mixed with available excavated soil and compost/cattle dung in the ratio of (2:2:1) 30cm deep dosing with antitermite treatment using chloropyrophos 50%EC @ 100ml per cum, levelling and watering including plantation of selected lawn grass etc complete all as specified and directed.NOTE:-(a) Fertile soil, manure (compost/cattle dung), chemical for antitermite treatmentshall be measured and paid for separately as supply only under respective items of this schedule.(b) Lawn grass for plantation of selected species shall be measured and paid for separately under relevant items of this schedule. |
| 7 | Supply only fertile soil for plantation of trees,shrubs/saplings, bushes and lawn grass etc,Note:-(a) Fertile soil shall be approved agricultural soil suitable for plantation and proper growth of different species of plants,shrubs,trees,hedges and lawn grass.(b) Stack cubic contents shall be measured. |
| 8 | Supply only compost/cattle dungNote:-(a) Stack cubic contents shall be measured. |
| 9 | Supply only chlorophyriphos or lindane emulsifiable concentrate conforming to IS:8944 or IS 632 respectively |
| 10 | Material and Labour for maintaining Trees,shrubs /saplings /lawn /hedges for complete quantum of work executed under srl item Nos 1.0 to 4.0 of BOQ and material supplied under srl item No 5.0 to 7.0, 9.0, 10.00 & 10.01 to 10.54 of BOQ for the period of 01 year after completion by employing adequate tradesman (Gardeners), mazdoor etc including tools, plants,chemicals,accessories etcas required for daily watering, cleaning the area by removing fallen leaves,foreign matters, depositing where directed including periodical services at regular interval for de-weedings of unwanted grass/growth and replacement of dried /growthless/ burnt trees,shrubs /saplings /hedges with the same species(grown height etc shall be similiar to that of rest planted trees, shrubs/saplings/hedges, dosing the plantation with approved fertilisers/manure,spraying insecticides,fungicides as and when required, treaming the trees/ shrubs/ saplings/hedges to the shape etc complete all as specified. |
| 11 | Note Reference to Sl Item No 8 :-(a) For day to day maintenance covered under srl item Nos 1.0 to 4.0 of BOQ and material supplied under srl item No 5.0 to 7.0, 9.0, 10.00 & 10.01 to 10.54 of BOQ Contractor shall employ adequate minimum 5(Five) experienced Gardeners and 05 (Five) labour per day.Muster roll shall be maintained for daily attendance of tradesman/mazdoor which is to be signed by both the parties (Contractor and Engr-in-Charge).As per requirement if more gardeners are employed no additional/extra claim on said account is payable.(b) Penal charges will be levied as follows:-(i) Non employment of minimum number of Gardeners/mazdoors specified above @ Rs 600/-day per person.(b) Non replacement of burnt/non growth trees /plant /lawn grass /shrubs /saplings /hedges etc @ quoted rate of that particular trees/plant/lawn grass /shrubs /saplings /hedges |
| 12 | Supply only selection grass for laying in lawns ( Pusa selection No 1 grass,disease free ) |
| 13 | Supply only well grown disease free trees /plant /shrubs /hedges as appended below:- |
| 14 | Areca Palm of height 6-7 feet with well developed clumps |
| 15 | Ashoka (Polyaltia longifolia) of height 6-7 feet |
| 16 | Arucaria of height 4-5feet |
| 17 | Arjuna (Terminalia arjuna) of height 5-6 feet |
| 18 | Alstonia (Alstonia Scholaris) of height 5-6 feet |
| 19 | Amaltas (cassia fistula) of height 5-6 feet |
| 20 | Acalphya (PB red and green) |
| 21 | Adenocalamn of height 1-2 feet |
| 22 | Bottle Palm (Hyophorbe Laqenicaullis) of height 5-6 feet with well developed trunk |
| 23 | Bottle brush(Callistemon Lenceolatus) of height 5-6 feet |
| 24 | Bouganvillea different varieties ( PB -3feet) |
| 25 | Budded Rose ( PB named variety) |
| 26 | Bigonia Vistara of height 1-2feet |
| 27 | Cycus Palm (30-40 leaves with well developed trunk) |
| 28 | Casuarina (casurina equisetifolia) of height 5-6 feet |
| 29 | Chandani white ( PB - 2feet) |
| 30 | Duranta pulmieri ( PB - 9 inches) |
| 31 | Erthyrinal indica ( PB 10-12 feet) |
| 32 | Euphobia of height 3feet |
| 33 | Fish Tail Palm (Wallichia Disticha) of height 6-7 feet |
| 34 | Ficus benjamina of height 5-6feet |
| 35 | Ficus Topiaries of height 6 feet |
| 36 | Ficus Starlite of height 4-5feet |
| 37 | Ficus Golden |
| 38 | Golden bottle brush of height 5-6feet |
| 39 | Gulmohar (Delonix regia) of height 5 feet |
| 40 | Golden Duranta ( PB - 9 inches) |
| 41 | Gardenia (PB) |
| 42 | Harsrinagar (Nyctanthus arbortristis) of height 2 feet |
| 43 | Hamelia petens of height 2 feet |
| 44 | Jacranda (Jacranda mimosifolia) of height 6-7 feet |
| 45 | Jal Patri (Putranjeeva roxbughai) of height 3-4 feet |
| 46 | Junipers Erecta of height 5feet |
| 47 | Kachnar (Bahunia Varigeta) of height 5-6 feet |
| 48 | Karanj (Pongamia pinnata) of height 5-6 feet |
| 49 | Kundi creepers of height 2feet |
| 50 | Lagestromia speciosa of height 5-6 feet |
| 51 | Michelia champaka of height 5-6 feet |
| 52 | Murraya paniculata of height 2-3 feet |
| 53 | Mulberry of height 4-5 feet |
| 54 | Maulsari (Mimosops elengi) of height 5-6 feet |
| 55 | Maror Phali (Begonia) of height 3-4 feet |
| 56 | Musanda of height 2 feet |
| 57 | Miniature Chandani (PB) |
| 58 | Motia (PB) |
| 59 | Nerium oleander of height 3 feet |
| 60 | Nerium variegated of height 3 feet |
| 61 | Phoenix Palm of height 4-5 feet |
| 62 | Quasgalis Indica of height 1-2 feet |
| 63 | Rain Tree (Sammanea Saman) of height 6-7 feet |
| 64 | Silver Oak (Grevillia robusta) of height 6-7 feet |
| 65 | Ticoma Cupers of height 2-3 feet |
| 66 | Thuja compacto (Mor pankh) of height 3 feet |
| 67 | White Duranta of height 1-2 feet |
| 68 | Supply & fixing of 10 Wdecorative inverted tripod type LED Bollard with IP 65/66 protection soft 360 degree light distribution. Body made of die cast aluminium and in triangularshape including 10watt LED with IP65 ingress protection and 4KV surge protection. Luminaire should have high efficieny isolated POTED driver . Minimum height of bollard 800 mm and width 180 mm (min).OEM should have in house NABL appproved Lab and submit LM79 report along with NABL certificate. Third party lab report will not be accepted. BIS of both Luminaire and driver are required and grouted at PCC foundation with necessary nuts and bolts complete all as specified and directed by Engr-in-Charge. Note : Earth work and PCC shall be measured and paid for separately. |
| 69 | Supply and fixing of 60W LED Flood Light with IP 65/66 prorection with Toughened Clear Glass Pressure Die Cast Aluminium Housing with Mandatory Secondary optics, System Efficacy of the Luminaries: >110 Lm/W, Beam Angle 60 Degree, CCT : 3000K( WARM COLOUR) ANSI BIN, CRI>70 including 60watt LED, LED driver shall be constant current type potted Driver. Luminaire shall have surge protection devices of minimum 10KV inside the Driver compartment. Total harmonic distortion shall be <10% with power factor min 0.95. The driver shall have an efficiency >85%. It should give consistent performance in the input voltage range of 120V-270V at 50 Hz . Luminaire shall be embossed or screen printed withmanufacturer Name/logo .OEM should have in house NABL appproved Lab and submit LM79 report along with NABL certificate. Third party lab report will not be accepted. BIS of both Luminaire and driver are requiredand grouted at PCC foundation with necessary nuts and bolts complete all as specified and directed by Engr-in-Charge. Note : Earth work and PCC shall be measured and paid for separately. |
| 70 | Supply and fixing of shrub/tree uplighter 5W LED spike light cast aluminium housing 8 mm thick tempered glass, environment friengly, compact, light weight, energy saving, including 5 watt LED, IP 65/66 protection LED spike light using COB LED as light source suitable for tree and plants up lighting, colour of the light is decided and directed by Engr-in Charge.Luminaire shall have surge protection devices of minimum 4KV inside the Driver compartment. Total harmonic distortion shall be <10% with power factor min 0.95. The driver shall have an efficiency >85%. It should give consistent performance in the input voltage range of 180V-240V at 50 Hz . Luminaire shall be embossed or screen printed withmanufacturer Name/logo. OEM should have in house NABL appproved Lab and submit LM79 report along with NABL certificate. Third party lab report will not be accepted. BIS of both Luminaire and driver are required andgrouted in PCC foundation with necessary nuts and boltscompleteall as specified and directed by Engr-in-Charge. Note : Earth work and PCC shall be measured and paid for separately. |
| 71 | Supply and fixing post top lantern LED type 40 watt including 40 watt LED AC outdoor type with decorative post top for 360 degree indirect light IP 65/66 protection with impact, Glare-free and better uniformity and corrosion resistant, LED driver shall be constant current type potted Driver. Luminaire shall have surge protection devices of minimum 10KV inside the Driver compartment. Total harmonic distortion shall be <10% with power factor min 0.95. The driver shall have an efficiency >85%. It should give consistent performance in the input voltage range of 120V-270V at 50 Hz . Luminaire shall be embossed or screen printed withmanufacturer Name/logo. OEM should have in house NABL appproved Lab and submit LM79 report along with NABL certificate. Third party lab report will not be accepted. BIS of both Luminaire and driver are required and grouted at PCC foundation with necessary nuts and bolts complete all as specified and directed by Engr-in-Charge. Note : Earth work and PCC shall be measured and paid for separately. |
| 72 | Supply and fixing recessed step light LED type 6 Watt with IP 65/66 protection, LED driver shall be constant current type potted Driver. Luminaire shall have surge protection devices of minimum 4KV inside the Driver compartment.It should give consistent performance in the input voltage 240V at 50 Hz . Luminaire shall be embossed or screen printed withmanufacturer Name/logo. OEM should have in house NABL appproved Lab and submit LM79 report along with NABL certificate. Third party lab report will not be accepted. BIS of both Luminaire and driver are required and including cutting/fixing in existing kota stone/granite in steps/staircase complete all as specified and directed by Engr-in-Charge. |
| 73 | S&F Cable junction Boxes of size 130X130X77mm weather proof IP 66/69 protection for outdoor installation with knockouts for cable entry for 6 Sqmm cable and mounting it on the poles /pipes for garden lights with membranes and terminals for cable entry, with all suitable supports,clamps, nuts and washers complete all as specified and directed by Engr-in-Charge. |
| 74 | S & F Rigid non-metallic PVC conduit ofsize 40mm bore havingwall thickness not less than 2mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for cable protection and laying in tranches complete all as specified and directed by Engr-in-Charge. |
| 75 | Supplying, laying, commissioning and testing wheather proof flat twin coreservice cable with aluminium conductor of size 6 Sqmm nominal cross sectional area 415 Volts grade, laid in trenches orducts or passing through road crossing, pipes fixed to wall/poles complete all as specified and as directed by directed by Engr-in-Charge. |
| 76 | Supply & fixing Timer Switch astronomical with internal battery to enable timing function in case of power failure DIN Rail mountable design with display digital. A manual override option operated on 230V AC single phase power supply having NO+NC contacts for control complete all as specified and as directed byEngr-in-Charge. |
| 77 | Aluminium Bus Bar chamber, 4 strips, 63 Amp TPN with CRCA sheet 3.15mmoutdoor type with IP 54 protection and MS angle Iron leg andframe of suitable size with front and rear opening door having 1 incoming and 4 outgoing cablehole (20mm dia) with rubber bushes/glands including 4 Nos angle iron legs grouted in PCC foundation as required complete, all as specified directed by Engr-in-Charge. Note : Earth work and PCC shall be measured and paid for separately. |
| 78 | Material and Labour for plain for Cement concrete 1:3:6 type C-2 (using 40mm graded crushedstone aggregate) as in foundations, filling and mass concrete, compete, all as specified directed by Engr-in-Charge. |
| 79 | Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.50m in depthand getting out complete all as specified and directed by Engr-in-Charge. |
| 80 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge. |
| 81 | Removing surplus excavated spoil(soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |