| 1 | Dismantling of existing structures like culverts, bridges, retaining walls and other structurecomprising of masonry, cement concrete, wood work, steel work, including T&P andscaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. |
| 2 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specification |
| 3 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 4 | Providing, laying, spreading and compacting stone aggregates of specific sizesto water bound macadam specification including spreading in uniform thickness,hand packing, rolling with three wheel 80-100 kN static roller in stages to propergrade and camber, applying and brooming, crushable screening to fill-up theinterstices of coarse aggregate, watering and compacting to the required densityGrading 2 as per Technical Specification Clause 405. |
| 5 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with threewheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405 |
| 6 | Providing and Laying of Interlocking Concrete Block (M-35) Pavements havingthickness 80 mm as per drawings and Technical Specification Clause 1504. |
| 7 | Providing concrete for plain/ reinforced concrete in open foundations complete asper drawings and technical specifications Clause 802, 803, 1202 & 1203.P.C.C. grade M 20 |
| 8 | Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 RR 1:5 |
| 9 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (M 25) |
| 10 | Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as perdrawings and technical specification Clauses 1002, 1005, 1010 & 1202(The reinforcement steel shall be procured from original (primary) steel producers as perclause no. 2011.3.1 of MORD specifications (First revision\"2014) and IS 1786:2008 clause no . 1.6) |