Tender For Repair/Maintenance Of Pump Set, Motors, Lt Panels, Starters, Mcc/Ats Panels, Water Meters, Apfc Panels And Connected Works At Various Mes Installation At Dagshai Under Ge Kasauli, dagshai-Himachal Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Pump Set, Motors, Lt Panels, Starters, Mcc/Ats Panels, Water Meters, Apfc Panels And Connected Works At Various Mes Installation At Dagshai Under Ge Kasauli. Submission Date for this Tender is 08-05-2023. Electrical Panel Tenders in dagshai Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37189691
Corrigendum : Tender For Repair/Maintenance Of Pump Set, Motors, Lt Panels, Starters, Mcc/Ats Panels, Water Meters, Apfc Panels And Connected Works At Various Mes Installation At Dagshai Under Ge Kasauli
Open Tender
Indian
Himachal Pradesh
dagshai
08-05-2023

Tender Details

Tender For Repair/Maintenance Of Pump Set, Motors, Lt Panels, Starters, Mcc/Ats Panels, Water Meters, Apfc Panels And Connected Works At Various Mes Installation At Dagshai Under Ge Kasauli

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 44 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF PUMP SET, MOTORS, LT PANELS, STARTERS, MCC/ATS PANELS, WATER METERS, APFC PANELS AND CONNECTED WORKS AT VARIOUS MES INSTALLATION AT DAGSHAI UNDER GE KASAULI.
Sl. No. Item Description
1Schedule "A" Section - I
2Disconnecting /unscrewing coupling for 240 HP pump set and seperating pump and motor, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location ,making all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge.
3Coupling Set suitable for 240 HP Pumping set
4Replacement of gun metalimpeller
5Replacement of gun metal Bush
6Replacement of Gland Sleeve
7Replacement of body Neck ring gun metal
8Replacement of Pump shaft stainless steel
9Counter Plate stainless steel
10Diffuser Packing
11Impeller brazing machining and reboring
12New Key way of impeller disc
13Diffuser outer dia brazing and machining
14Impellers outer dia brazing and machining
15All as per Srl item No.1.00 above herein before but for capacity 150HP pumpset complete all as specified and directed by Engr-in-Charge. Note for Srl Item Nos 1.00 & 2.00 :- (i) All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under:- (ii) Attend the complaint with in 12 Hrs and after repairing the same to be fixed and testing within 48 Hrs.
16Coupling Set suitable for 150 HP Pumping set
17Replacement of gun metalimpeller
18Replacement of gun metal Bush
19Replacement of Gland Sleeve
20Replacement of body Neck ring gun metal
21Replacement of Pump shaft stainless steel
22Counter Plate stainless steel
23Diffuser Packing
24Impeller brazing machining and reboring
25New Key way of impeller disc
26Diffuser outer dia brazing and machining
27Impellers outer dia brazing and machining
28S & F in replacement of pressure gauge upto 100 Kg/sqcm (as per existing sample), incl taking down old unserviceable completeall as specified and as directed by Engineer-in-charge.
29S&F in replacement of ball bearing 6314, incl taking out old unserviceable completeall as specified and as directed by Engineer-in-charge.
30S&F in replacement of ball bearing 6319/6319-C3, incl taking out old unserviceable completeall as specified and as directed by Engineer-in-charge.
31S&F in replacement of roller bearing NU 307, incl taking out old unserviceable completeall as specified and as directed by Engineer-in-charge.
32Disconnecting existing electric motor and dismantling from foundation and transporting the same to the workshop for repairs and refixing the same on existing location after repair & making electric connection including testing and commissionig complete. including taking out burnt winding and rewinding the motor with super enamelled copper wires as per existing guage and size including super quality of varnish and insulating material as required for 240 HP electric motor completeall as specified and as directed by Engineer-in-charge. Note : Attend the complaint with in 12 Hrs and after repairing the same to be fixed and testing within 48 Hrs.
33-ditto- all as per Item No. 7.00 above but of capacity 150 HP
34-ditto- all as per Item No. 7.00 above but of capacity 125 HP
35-ditto- all as per item No. 7.00 above but of capacity 75 HP
36-ditto- all as per item No. 7.00 above but of capacity 60 HP
37Disconnecting /unscrewing Auto Transformer Starter Panel of capacity 125/150/ 240 HP, disconnecting all electric connections and carrying out necessary repair at site with replacement of parts as under complete all as specified including testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid as under.
38S&F Electronic over current relay cap 0.5 – 60A220V AC complete with arrangement for over current, phase reversal, under current and phase imbalance protection suitable for 125/150/240 HP ATS Panel completeall as specified and as directed by Engineer-in-charge.
39S&F Three pole power contactor, AC Control, AC3 Rating 95A/ 47 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation including taking out existing unserviceable power contactor from site completeall as specified and as directed by Engineer-in-charge.
40All as per Srl Item No. 10.00 above but of AC3 Rating 140A/ 75 KW, 415V complete all as specified and as directed by Engineer-in-charge.
41All as per Srl Item No. 10.00 above but of AC3 Rating 265A/ 140 KW, 415V completeall as specified and as directed by Engineer-in-charge.
42All as per Srl Item No. 10.00 above but of AC3 Rating 300A/ 160 KW, 415V completeall as specified and as directed by Engineer-in-charge.
43S&F No volt coil in replacement of old unsv completeall as specified and as directed by Engineer-in-charge
44S&F Timer in replacement of old unsv completeall as specified and as directed by Engineer-in-charge.
45S&F Digital voltmeter of size (96 x 96)mm range 0 to 500 volts, 3 phase with inbuilt selector switch, suitable for CT operation- 01 set incl taking down old unsv complete all as specified and directed by Engineer-in-charge.
46S&F Digital Ammeterrange 0 to 400 Amps, 3 phase with iin built in selector switch, suitable for CT operation- 01 set.all as specified and as directed by Engineer-in-charge
47S&F Indicator set RYB - 01 set of 3 pcs in replacement of old unsv complete all as specified and as directed by Engineer-in-charge
48S&F Selector switch (as per existing) in replacement of old unsv complete all as specified and as directed by Engineer-in-charge
49M&L for reparing/servicing of APFC panel board of Cap 100 KVAr by replacing the all defective components with new components, rewiring, cleaning, testing, reconnecting, reinstalling and commissioning the APFC panel board complete all as directed by Engineer-in-Charge. Note : Supply of cables, wires & other minor spare parts etc will deemed to be included in the quoted rate.
50M & L for replacement of cooling fan for 100 KVAr capacity APFC panel with proper connection, incl taking down old unsv complete all as directed by Engineer-in-Charge.
51Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completioncomplete all as specified and directed by Engr-in-charge. Note : The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in altemate layers, 25mm GI Pipe (light grade) for watering 50mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
52Installation, testing and commissioning of chemical earthing complete with copper plate elctrode of size 900mmx600mmx5mm thickness, buried directly in ground vertically to a depth not less than 4mtr below normal ground level earth plate electrode connected to and incl copper earthing lead strip 32x6mm as main earthing lead by means of tinned copper/ brass bolts, nuts, check nuts and washer beside brazing at all joints as directed and earthing lead protected with 40mm dia medium grade GI pipe from electrode and upto incl the earth test point, 20mm dia watering pipe medium grade GI incl funnel, fire mesh, alternate layers of 150mm thickness each ofcharcoal, common salt, magnisium sulphate/ chemical and as per manufacturer"s recommendation including below the copper electrode also and excavation in any type of soil, removal of surplus soil, PCC pit chamber in PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate, RCC cover 50mm thick in RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate reinforced with 8mm dia MS deformed bars @75 mm C/C both ways incl MS angle iron frame of size 40mmx40mmx3mm and incl testing the earthing on completioin, complete all as specified. The result of the earth resistance should be less that 1 Ohm and recorded results to be submitted to Engr-in-Charge. Note : Old earthings are conventional type and sch of credit has been accounted for accordingly.
53S&F MCCB 630 Amps 4 pole, 50 KA, 415 V, 50 Hz withthermal setting between 70% to 100%, adjustable type and connecting up in the existing panel locationincluding taking out existing unserviceable MCCBcompleteall as specified and as directed by Engineer-in-charge.
54All as per Srl Item No. 24.00 above but MCCB of capacity 400 Amps 4 pole, completeall as specified and as directed by Engineer-in-charge.
55All as per Srl Item No. 24.00 above but MCCB of capacity 200 Amps 4 pole, completeall as specified and as directed by Engineer-in-charge.
56M & L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates
57Material & labour for cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation of electric poles, sturts, blocks with and including necessary form work, and fair finish to exposed surfaces without using extra cement complete all as specified.
58M & L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
59Supply & Fixing double walled corrugated HDPE duct pipe of 63 mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete all as specified.
60Supply, laying, jointing and testing replacement PVC insulated cable 1100 volt grade with multi stranded, single core copper 95 Sqmm,Grade As Per IS 7098 (Part -1) 1988 including making electrical connection for main panel, to starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of copper lugs/thimbles complete all as specified and as directed by Engr-in-charge.
61All as per Srl Item No. 31.00 above but single core copper 120 Sqmm complete all as specified and as directed by Engr-in-charge.
62All as per Srl Item No. 31.00 above but single core copper 185 Sqmm complete all as specified and as directed by Engr-in-charge.
63M & L for taking out the Auto Transformer Panel (ATS) set incl disconnecting all electric connections, carrying it to 15 Mtr distance and making new foundation suitable for the ATS panel and grouting properly with nuts and bolts, fixing the same ATS panel including making all electric connection and testing the panel complete all as specified and directed by Engr-in Charge.
64S & F in replacement Copper Thimble of below mentioned sizes complete all as specified and directed by Engineer in charge.
65220mm
66150mm
67120mm
6890mm
69Taking out old unsv and Supply installation and testing of Auto Transformer starter panel of capacity 240 HP with Cubical type ATS Starter panel made of Techno Modular construction with CRCA sheet steel suitable for 415 V, 3 phase, 4 wire 50 Hz AC supply system. Having required front surface area, fabricated in Fully compartmentalized design from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates i/c cleaning & finishing complete with 10 tank spray based tricationic phosphating treatment process for powder coating in approved shade, PU Foam Gasket without manual pasting, joint less (temperature withstand capacity -40degC to + 120degC) for maintain IP protection complete with automatic phase corrector 400 Amp 3P Contactor-02 Nos with MCCB TP 250 Amps 36 kA with rotory handle -01 No, having adjustable tapping 50%, 65% and 80% four starts per hour. Power contactors-03 Nos of capacity 400A, 300A and 200A, BOCR 3DE electronic over current relay, phase & motor on/off/trip indications and all other standerd fittings for ATS, with digital volt meter (96x96) mm, 0-500 Volts and digital ammeter complete all as specified and as directed by Engineer-in-Charge including taking down the existing starter panel. Note : Foundation shall be provided as per existing size and specification.
70S & F in replacement of battery 12 Volts, 180 Ah maintenance free battery, incl taking down old unsv complete all as specified and directed by Engr-in-Charge
71S & F in replacement of Start Push button for ATS Panel as per existing complete all as specified and directed by Engr-in-Charge
72S & F in replacement of Stop Push button for ATS Panel as per existing complete all as specified and directed by Engr-in-Charge
73S & F in replacement of MC Contactor of 25 KVAr capacity for APFC Panel all as specified and directed by Engr-in-Charge.
74S & F in replacement of MC Contactor of 10 KVAr capacity for APFC Panel all as specified and directed by Engr-in-Charge.
75S & F in replacement of MC Contactor of 05 KVAr capacity for APFC Panel all as specified and directed by Engr-in-Charge.
76S & F in replacement of Heavy Duty Capacitor of 20 KVAr capacity for APFC Panel all as specified and directed by Engr-in-Charge.
77S & F in replacement of Heavy Duty Capacitor of 10 KVAr capacity for APFC Panel all as specified and directed by Engr-in-Charge.
78S & F in replacement of Heavy Duty Capacitor of 1 to 5 KVAr capacity for APFC Panel all as specified and directed by Engr-in-Charge.
79S&F in replacement of Rubber Mat of size (1 Meter x 2 meter x 19mm) for installing in pump houses for safety purpose of operators as specified and directed by Engineer in charge.
80S&F in replacement of stud for 240/150/125 HP pumpsets (as per existing sample), complete all as specified and directed by Engineer in charge.
81S & F in replacement of current transformer 250/5A, Class 1 ID 45 CT With 15 VA for Ammeter with current rating 5.0 amps for ATS panel, all as specified and directed by Engr-in-Charge.
82S & F in replacement of Bypass Switch of rating 400A (as per existing sample) of Servo Voltage Stablizer of rated capacity 250-300KVA, rated voltage 240V with 3 nos of phases, complete all as specified and directed by Engr-in-Charge.
83S&F in replacement of shock treatment chart in multi languages i.e, English and Hindi of size (2 x 1) Sqm in wooden base with proper frame and arrangement to fix, complete all as specified and directed by engineer in charge.
84M & L for Sheet metal enclosure factory made dust proof vermin for indoor type made out of CRCA sheet 2mm thick except inner sheath of 3mm powder coated machine presssedalong with fitting/fixtures on wall and making the connection as per ground requirement with provn of MCCB 4 pole 100Amp rating with breaking capacity 36 KA 415 volts , 50 Hz ,thimble/lugs, aslo includingIndicator Lamp R,Y,B = 01 Set, all nuts & bolts required for fixing, complete all as specified and directed by Engineer - in - Charge.
85M & L for Sheet metal enclosure factory made dust proof vermin for indoor type made out of CRCA sheet 2mm thick except inner sheath of 3mm powder coated machine presssedalong with fitting/fixtures on wall and making the connection as per ground requirement with provn of MCCB 4 pole 630Amp rating with breaking capacity 36 KA 415 volts , 50 Hz ,thimble/lugs, aslo includingIndicator Lamp R,Y,B = 01 Set, all nuts bolts required for fixing with existing cable, complete all as specified and directed by Engineer - in - Charge.
86S & F illuminated display board with names of Water supply installations and distribution tanks of size 1.25mx0.2mx0.9m (LXBXH) with flex of light blue (MES Colour) colour of letters shall be white, outer side fabrication bordered with aluminium angle frame of 25mmx25mmx3mm thick, inner side fabricated with 12mm MS square bar, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 nos 30mmx4mm thick MS Flat of 2m length welded to GI Pipe and nut bolt and washer with display board not less than 3m and PCC 1:2:4 type B1 for foundation including all internal wiring s and illuminated with LED 40W Tubelight fittings 01 Nos SMC/FRP junction box 140mmx140mmx95mm inner dimension including its fixing arrangement and written letters in capital, size of letters proportion with overall size of board complete all as specified and as directed .
87S & F illuminated display board with detailed Schematic diagram of water supply installations including source, tanks of all capacity, suction line, discharge line, NRVs, Sluice valves etc in coloured of size 1.25mx0.2mx0.9m (LXBXH) on flex, outerside fabrication bordered with aluminium angle frame of 25mmx25mmx3mm thick, innerside fabricated with 12mm MS square bar, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 nos 30mmx4mm thick MS Flat of 2m length welded to GI Pipe and nut bolt and washer with display board not less than 3m and PCC 1:2:4 type B1 for foundation including all internal wiring s and illuminated with LED 40W Tubelight fittings 01 Nos SMC/FRP junction box 140mmx140mmx95mm inner dimension including its fixing arrangementcomplete all as specified and as directed . Note for Srl Item Nos 53.00 & 54.00 :- (i) Before manufacturing boards, drawing and design of board incl colour of the board shall be approved by Engr-in-Charge (ii) Each board display name shall be given seperately.
88Supply and fixing Design, fabricate, supply, testing and commisioning of CPRI approved factory made LT Panel Board double door, out door type fabricated out of 3.15mm thick CRCA sheet steel for outer body and 2.00mm thick CRCA Sheet for inner partition walls, independent cabinate with cabinate doors for Change Over Switch, MCCBs, Bus Bars, cable Alley, metering equipment, vertical type floor mounted on angle iron frame of ISA 50x50x5mm with minimum height of legs 45 cm, minimum IP-54 protection, comprising of solid copper bus bar 4 strips suitable for 200 Amps, embeded to PCC complete with internal wiring, epoxy powder coatedand connection of cable ends with suitable size of aluminium cable lugs with the following accessories :- (a) INCOMING :- (i) MCCB 125 Amps, 4 Pole, 415 Volt, 10 KA - 01 Nos (ii) On Load change over switch 100 Amps, 4 Pole, 415 V - 01 No(b) OUTGOING :-(i) MCCB 100 Amps, 4 Pole, 415 Volt, 10 KA - 02 Nos (ii) MCCB 63 Amps, 4 Pole, 415 Volt, 10 KA - 02 Nos(iii)Digital volt meter- 01 No(iv) Digital ammeter -01 Nos(v) Selector Switch for Amp/Volt Meter - 02 Nos(vi) Current Transfer (CT) - 03 Nos(vii) Phase indicator lamp (RYB) set of three - 01 No Note :-1. Contractor should got approved the drawing of panel board from GE before fabrication.
89M & L for Repair/Replacement of SITC of isolation transformer including main power board and control card complete set suitable for 10KVA online UPS complete as specified and directed by Engineer in charge.
90M & L for Repair/Replacement of SITC Transistors suitable for 10 KVA online UPS complete all as specified and directed by Engineer in charge.
91M & L for Repair/Replacement of RGBTs suitable for 10 KVA online UPS complete all as specified and directed by Engr-In-Charge.
92Amount of credit of Rs. 136561.55 for retrived old material as mentioned in Schedule "A" section-II of tender document in pdf form, will be deducted offline while acceptence of tender.