Tender For Repair/Maintenance Of Joinery, Guard Bar, Wire Mesh, Glass Panes, Flooring Garbage Bins, Septic Tanks, Soak Wells, Day To Day Cleaning Of Sewage Lines And Other Misc B&R Works In Smq Area At Afs Sulur
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 May 2023
0 days left
EMD
1.73 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
sulur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair / Maintenance Of Joinery, Guard Bar, Wire Mesh, Glass Panes, Flooring Garbage Bins, Septic Tanks, Soak Wells, Day To Day Cleaning Of Sewage Lines And Other Misc B&R Works In Smq Area At Afs Sulur
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE A BOQ |
| 2 | Taking down chowkhat or frame(wooden/steel) not exceeding1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. |
| 3 | Taking down chowkhat or frame(wooden/steel) exceeding 1.50 Sqm not exceeding4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed. |
| 4 | Taking down shutters of any description exc 1.0 Sq.m andn.exc 2.0 Sq.m each complete all as specified and directed. |
| 5 | Resecuringwithout taking down chowkhats or frames but with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed. |
| 6 | Resecuringwithout taking down chowkhats or frames but with shutters (without taking off shutters from the frames)exc 1.5 sqm but n exc 4 sqm each complete all as specified and directed. |
| 7 | M & L cutting holes in stone wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts/lugs and making good dismantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete as required complete all as specified and as directed. |
| 8 | S&F MS work (flat iron) 25mm x 3mm thick, in small articles such as hold fast and similar small articles conforming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 9 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed. |
| 10 | S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVC\"C\"channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail.Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitablePVCsheetbeadingand jointed together with solvent cement complete all as specified and as directed. |
| 11 | M&L Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. |
| 12 | Supply and fixing 200 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed. |
| 13 | Supply and fixing in repairs 200 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed. |
| 14 | Supply and fixing 100 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed. |
| 15 | Supply and fixing in repairs 100 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed. |
| 16 | S&F Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete all as specified and as directed. |
| 17 | S&F Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete including taking down existing oneall as specified and as directed. |
| 18 | S&F 200mm extruded aluminum alloy handles, fabricatedtype, anodisedcomplete all as specified and as directed. |
| 19 | S&F 150mm long Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminum alloy and fixed complete all as specified and as directed. |
| 20 | S&F 200mm extruded Extruded aluminium alloy handles, fabricated type, anodised including taking down existing one complete all as specified and as directed. |
| 21 | Supply and Fixing 30 mm thick factory made flush shutter solid core construction with block board core and plywood face panels, comercial type on both faces complete all as specified and directed. |
| 22 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete including taking down existing one complete all as specified and directed |
| 23 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed. |
| 24 | Supply and fixing 100mm long Butt hinges medium weight cold rolledstainless steel, and fixed complete all as specified and as directed. |
| 25 | Supply and fixing 100mm long Butt hinges medium weight cold rolledstainless steel, fixed in repair to wooden frame/welded to metal frame complete all as specified and directed. |
| 26 | S&F Butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed. |
| 27 | Supply and fixing in repairs butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed. |
| 28 | S&F Factory made 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);complete all as specified and directed |
| 29 | M & L Preparation of new wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed |
| 30 | Note for item No 29 :-(a) All synthetic enamel paint shall be of 1st quality manufactured by the standard firms of make as specified. |
| 31 | (b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works. |
| 32 | (c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE. |
| 33 | (d)Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite) |
| 34 | (e )Unless otherwise specified the tints of paint shall be as approved by the GE |
| 35 | (f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval. |
| 36 | (g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge. |
| 37 | (h) No hair marks from the brushor clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory. |
| 38 | S & F Aluminum handles cast type anodised 150 mm long complete all as specified and as directed. |
| 39 | S & F Aluminum handles cast type anodised 100 mm long complete all as specified and as directed. |
| 40 | Supply and fixing in repairs aluminum handles cast type anodised 150 mm long complete all as specified and as directed. |
| 41 | S&F300mm, ordinary Mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 42 | S&F in repairs 300mm, ordinary Mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 43 | S&F 250mm long Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminum alloy and fixed complete all as specified and as directed. |
| 44 | Supply and Fixing in repairs 250mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminum alloy and fixed complete all as specified and as directed. |
| 45 | S &F 12mm thickness Medium density fibre board, exterior grade, fixed to timber framework with screws complete all as sepcified and directed. |
| 46 | Dismantling boarding, any description, fixed in any position with nails/ screws complete as as specified and directed. |
| 47 | S & F4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 48 | S & F 18/19mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & fixed with screws to timber frame work complete all as specified and directed. |
| 49 | S & F in repairs cast iron or mild steel Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed. |
| 50 | S&F Mild steel work in framed work such as grills and similar work including framed guard bars, barred iron doors, ladders, framed balusters etc., including of fixing of sheet steel or other covering to doors etc., to be prepared for hanging /sliding with or including either hooks or hinges or steel hanging door fittings etc., confirming to Fe 410-0 or Fe 310-0 work complete all as specified and directed. |
| 51 | M&L 100 mm thick Plain cement concrete1:4:8type D-2(using 40 mm gradedstone aggregate ) as in sub base , fillng and mass concrete or as in receiving tiles/ surface channels and drains etc including demolition complete all as specified and directed. |
| 52 | M&L Chequered cement concrete tiles 30cmx30cmx25mm thick machine pressed set jointed and pointed in neat cement slurry as in floors and cut and polished using grey cement andpigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) includingdemolishing the existing tile complete all as specified anddirectedNote : The manufacturer\"s test certificate andindividual test certificate for tilesmust be submitted for approval by the concerned authority prior to installation/fixing. |
| 53 | M&L 100mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates),as in path/hardstanding including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement including demolition of existing damaged cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness and rubish material shall be disposal to out side MD land complete all as specified and as directed. |
| 54 | M&L Complete removal of existing damaged water proofing treatment and expose of top surface ofRCC slab of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with water and using wire brush including removing debris to out side the MoD landand providing following :- |
| 55 | Note for Item No 54 :-(a)Dismantling existing cement concrete/roof tiles on roof including removing debris to out side MD land as directed. |
| 56 | (b)Rendering 10mm thick in CM 1:3on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixingwater proofing compound @ 3% by weight of cement. |
| 57 | (c)Apply a coat of bituminous primer confirming to IS-3384@ 0.25 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried |
| 58 | (d)After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. |
| 59 | (e) Providing 3 mm thick APP modified water proofing as approved by GE weighing not less than 3.5kg per sqm unrolled over the bituminous coated surface with 100mm over laps, the overlapshall be sealed by flame as per manufacture instructions complete. |
| 60 | (f)Applying a coat of aluminium paint at the rate of 110 gm per sqm as per manufacture instruuction over bituminous layer complete all as directed. |
| 61 | (g) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface |
| 62 | M & L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate bring upto the slope by providing filling of light weight materials such as cinder, light weight concrete etc as required average 40mm thickness complete all as pspecified and directed. |
| 63 | M&L Vitrified Ceramic tiles 10 mm thick, lightshade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6complete including dismantling of existing tile and disposal off to outside MD land all as specified and as directed. |
| 64 | M&L Vitrified Ceramic tiles 10 mm thick, lightshade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6complete including dismantling of existing tile and disposal of to outside MD land all as specified and as directed. |
| 65 | Note for item No 63 & 64 :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (ii) The manufacturer\"s test certificate andindividual test certificateof Tilesmust be submitted for approval by the concerned authority prior to installation. |
| 66 | Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and M & L Glazed ceramic coloured tiles 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dadoincluding 10mm thick 1:3 backingcoat complete all as specified and as directed. |
| 67 | Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises andM & L Joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile of sizeexc 0.09 Sqm but n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incuding screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) complete all as specified and as directed. |
| 68 | Note for item No 66 & 67 :- The manufacturer\"s test certificate of Tilesmust be submitted for approval by the concerned authority prior to installation. |
| 69 | M&L Granite work(of any type) 18 to 20mm thick(table rubbed and polished including round edge) in steps, jambs, pillars, window cills, cooking platforms, wash basin platformand like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade over and including 15mm thick screed bed in CM 1:4 in repairs complete all as specified and directed by Engineer-in-Charge. |
| 70 | S &F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as sepcified and directed. |
| 71 | M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm each pane complete all as specified and directed. |
| 72 | M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 sqm each pane complete all as specified and directed. |
| 73 | S & F Aluminium powder coated ofthree track sliding window outer frame top & sides (section no-20831) of size 92.0x31.75x1.5mm weighing 1.06 Kg/m, frame bottom (Section No 20832) of size 92.0x31.75x1.5mm weighing 1.248Kg/m , shutter to plain vertical (Section No 21093) of size 39x18x1.5mm weighing 0.634 Kg/m, shutter interlock vertical frame (section 21094) of size 39x18x1.55 weighing 0.734 Kg/m, shutter bottom horizontal frame (Section No 20551) size 40x20x1.5mm weighing 0.484 Kg/m, with powder coating of min thickness 50 micron , sliding type with out sash bars, 4mm thickness colour glass, rubber packing, snap beading screws with stainless steel wire mesh, including taking down existing window with chowkats of any size, completet all as specified |
| 74 | Supply and fixing in repairs factory made UPVC white colour Three track three panelssliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of UPVC multichambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drillingof holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For UPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profiledimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 75 | Taking down of aluminum/Glass doors carefully and re-fixing in same opening including necessary repairing/cleaning/greasing etc and make the same fully functional all as specified and directed. |
| 76 | Taking down the existing locking system, contains any number of levers replacing the strucked/damaged levers, applying oil to all parts and making functional properly and refixed in position complete all as specifed and as directed |
| 77 | S&F 25mm dia mild steel powder coated drapery rod out to length required without joint in between and fixed at openings including taking existing one complete as directedby Engr-in-charge. |
| 78 | S&F Mild steel powder coatedbrackets for holding the drapery rod and fixed to wall with MS screw including taking down existing one complete as directedby Engr-in-charge. |
| 79 | Supply and Fixing in repairs Mild steel powder coated fancy type brackets fixed at both the end of drapery rod of same colour and type of drapery rod as directed. |
| 80 | M&L in repairsDoom grating 125mm dia with waste hole of PTMT(minimum weight 40gms) Including taking down existing one complete all as specified and as directed by Engneer-in-Charge. |
| 81 | M&L Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering and material and labour for Rendering 15 mm thick in two layers onbrick or stone or concrete surfaces,first coat 10mm thick in cement mortar1:4 and 2nd coat 5mm thick in cement mortar1:4 mixed with water proofing compound as per manufacturer instructionsfinished even and smooth without using extra cement completeall as specified and directed. |
| 82 | Note for Item No 81 :- Supply only water proofing compound shall be measured and paid seperately. |
| 83 | SupplyOnly integral water proofing compound complete all as specified and as directed. |
| 84 | M&L Preparation of new plastered surfaces wall/ ceiling and applying two coat of white wasing on ceiling/ walls surfaces complete all as specified and directed. |
| 85 | M&L Preparation of new plastered surfaces wallapplying two coat of OBD over a coat of alkali resistant priming paint complete all as specified and directed. |
| 86 | M&L Checking of floor, plinth, plaster etc requiring masonry work and carrying out minor repairs such as edges, patches etc, including petty repairs material like sand, cement & aggregate to make it functional complete all as specified and as directed by Engineer-in-Charge. The rates for plastering / plinth include for: (a) Preparing the surfaces.(b) Thickness of plaster/plinth key in joints, etc. (c) Anises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth.(d) All materials, labour and equipment & supply of integral waterproofing compound, (e) Scoring surface of plastering for key, where the surface is not required to be finished fair.(f) Plastering in patches (in repairs), exc 3 sq.m each patch, for preparing old walls to receive plastering\". Nothing extra shall be admissible for matching with existing work etc. (g) Any individual patch (other than nail hole, plug hole, etc.) are included for provided existing surface finish . |
| 87 | M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 80mm thickness M-40 grade, laid over and including M sand cushion of 50mm thick and packing the sides with PCC 1:3:6 type C1 (using 20mm graded stone aggregates)complete incl dismantling of existing tiles all as specified and directed. Note : The Unit rate quoted is included for Demolition of paver tiles of any description or thickness in floors,aprons etc laid bedded and pointed in any mortar and removing of debris outside of MD land |
| 88 | M&L Hardcoreofgaugenotexceeding 63mmofbroken stonesorboulders,deposited,spreadandlevelledin layersnotexceeding 15cmthick,wateredand rammed to a true surface including removal of existing completeall as specified and directed. |
| 89 | M&L in repairs Machine cut kota stone slab flooring 20-25mm thick over cement 25mm screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:4 including Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed. |
| 90 | M & L renewingcement concrete tilesin patches, area n exc 5 sq.m. Including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tilescomplete all as directed.Note : The rate included for cutting out broken tiles, removing and cleaning loose tiles, preparing bed removing rubbish, roming and replaing old with new tiles to match, complete with all cuttings etc, that may be required. New tiles requiredis deemed to be included all as directed. The unit rate is also including necessary beding in cement mortor. |
| 91 | Dismantling existing cement concrete on roof and removal to a distance exc 1.5 KM but not not exc 5 KM and deposited as directed. |
| 92 | M&L Plain cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in roof kerbs, benching rounded or chamfered onedge all as specified complete all as directed. |
| 93 | M&L Preparation of plastered or un plastered old surfaces of walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots etc and applying one coat of cement based paint complete all as specified and directed. |
| 94 | Note for item No 93:-(i)Before applying cement based paint ,the surface shall be thouroughly wetted to control surface suction. The surface shall be moist but not dripping wet when the paint applied .Surfaces which readily absorb moisture shall be wetted in one operation not more than one hour before painting.Surfaces which absorb moisture slowly shall be wtted in at least two operations not less than 30 minutes apart. |
| 95 | (ii)To maintain a uniform mixture and to prevent segregation ,the paint shall be stirred frequently in the bucket. |
| 96 | (iii)Painting surfaces shall be cured as soon as paint has hardened so as not be to damaged by the spray about 12 hours after the applications. |
| 97 | (iv)Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account. |
| 98 | (v) Work will be carried out through authorised applicator/ agency of approved manufacturer by GE and colourshall be asapproved by Engr in charge . |
| 99 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, cesspits, manholes, pier holes, etc. and getting out in hard/dense soil complete all as specified and as directed. |
| 100 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. |
| 101 | Removal of excavated material to a distance exceeding 1.50 Km andnot exceeding 5.00 Km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 102 | Demolition of brick work masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and as directed. |
| 103 | M&L Brickwork with burnt clay \"fly ash’ modular bricks, straight or curved on plan exc 6m mean radius built in cm 1:4 , complete all as specified and as directed |
| 104 | Description all as per item No 103here in above but except bricks. Note:-Serviceable bricks obtained from Sl item No 102 shall be reused. |
| 105 | Note for Item No 103 & 104 :- (a) Fly ash bricks shall be burnt clay flyash building bricks as per IS- 13757. |
| 106 | (b) The rates for work curved or polygonal on plan include for all extra cutting and extra waste in the body of the work. It shall be measured as mean length of wall. |
| 107 | (c) Sinking of steining shall be measured separately under relevent item. Well curbs, tie-rods, etc. shall be measured under the appropriate item. |
| 108 | (d) bricks shall be of class designation 75 (Kgf/cm). |
| 109 | (e) The quoted rate shall be deemed to be inclusivefor all scaffolding, ladders, plant and templates required |
| 110 | (f) Exposed faces of brick work shall be fair. |
| 111 | (g) Exposed faces shall be facing with best bricks |
| 112 | (h) The quoted rate shall be deemed to be inclusivefor Plumbing to angles |
| 113 | (j) Forming reveals to jambs where fair cutting on exposed faces shall not be involved |
| 114 | (k) The quoted rate shall be deemed to be inclusivefor preparing tops and sides of existing walls and the like for raising and extending |
| 115 | (l) Building in vertical seismic reinforcement at the jambs of openings, corners of walls, etc.shall be grouting in cement mortar 1:4 |
| 116 | M&L preparation of old decoratedplastered or unplastered surfaceof wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , treading, oil, greasy spots and applying one coat oil bound distemper complete all as specified and as directed. |
| 117 | Demolition of cement concrete (reinforced) in of any description and in any position and removal of debris out of MD land complete all as specified and directed. |
| 118 | M&L PCC (1:2:4) Type B1 (using 20 mm graded stone aggregate) as in coping of including necessary form work finished fair and even surface without using extra cement including weathering slightly roundedor chamfered angles and throating complete all as specifiedand as directed. |
| 119 | Excavating in post holes (or similar holes) in any type of soil, each not exc 0.5 cum, getting out in hard dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cmincluding demolition of existing damaged foundation of fencing posts complete all as specified and as directed. |
| 120 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed. |
| 121 | M&L Mild steelangle iron Posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 122 | M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm including taking down existing one complete all as specified and as directed. |
| 123 | M & L for pre-cast cement concrete block masonry with solid blocks of cement concrete exc. 10 cm width and setting in cement mortar 1:6 type C-1, 1:3:6 (using 20 mm graded stone aggregate) complete |
| 124 | M&L PCC 1:4:8, type D-2,using 40mm graded stone aggregate in foundation filling and mass concrete etc complete all as specified and as directed. |
| 125 | M&L Plain Cement concrete 1:3:6,type C-1, (using 20mm graded crushed stone aggregate) as in foundation of fencing post, filling and mass concrete etc complete all as specified and as directed. |
| 126 | M&L preparation of old decoratedplastered or unplastered surfaceof wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , treading, oil, greasy spots and applying one coat cement base paintcomplete all as specified and as directed. |
| 127 | M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 60mm thickness M-35 grade, laid over and including M sand cushion of 50mm thick and packing the sides with PCC 1:3:6 type C1 (using 20mm graded stone aggregates)complete incl dismantling of existing tiles all as specified and directed. Note : The Unit rate quoted is included for Demolition of paver tiles of any description or thickness in floors,aprons etc laid bedded and pointed in any mortar and removing of debris outside of MD land |
| 128 | S&F Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 gradeSt.-240) complete all as specified and as directed. |
| 129 | S&F Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted ,bolted or welded attachment.(Fe 410 -W (Gde- E-250) quality -A complete all as specified and as directed. |
| 130 | M&L Pre painted Coloured Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheetany colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws including dismantling of existing one all complete all asdirected. |
| 131 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mmthick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling of existing one all as directed. |
| 132 | Note for pre-painted coloured Galvalume roofing :- |
| 133 | (i) The manufacturer\"s test certificate andindividual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation. |
| 134 | (ii) The contractor shall ensure that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Totalcoated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides complete all as specified and as directed. |
| 135 | (iii) The painting shall be coloured baked enamel polyesterwith silicon coatingoffilm thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominalthickness Primer. |
| 136 | (iv) The contractor shall produce purchase vouchers for each lot and independent test for verification of Engineer-in-Charge. |
| 137 | M&L110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ringjoints fixed to wallincluding taking down existing damaged PVC Rain Water Pipes (any size) along with all fittings heads bends etc complete all as specified and as directed. |
| 138 | M&L PVC (SWR) bends any radius 110 mm dia fixed to wall including taking down existing one complete all as specified and as directed. |
| 139 | M&L PVC (SWR) 110mm junction (single T) equal or unequal provided with access door including taking down existing one complete all as specified and as directed. |
| 140 | M&L PVC (SWR) 110mm junction vent cowl all as specifedincluding taking down existing one complete all as specified and as directed. |
| 141 | M&L in repairs stack clamps out of 50 mm x 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays towall or rooffor 110 mm bore complete all as specified and directed. |
| 142 | S & F 150mm dia of half round ready made eaves gutter of pressure rating 6 kg/cm2 of approved make including necessary fitting like bend WC/MS clips etc complete all as specified and directed. |
| 143 | M & L Bullnosed chequered cement concretetiles 30cm x 30cm x 25mm thick machine pressed set jointed and pointed in neat cement slurry as in treads and cut and polished using grey cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor fnishes in cement mortar (1:4) including taking down existing tiles complete all as specified and as directed byEngineer-in Charge.Note :- The manufacturer\"s test certificate and individual test certificate of tiles must be submitted for approval by the concered authority prior to installation |
| 144 | M & L Chequered cement concretetiles machine pressed set jointed and pointed in neat cement slurry on vertical surfaces as in skirting, dados and risers of steps and cut and polished using grey cement and pigments over backing coatof mortar 10mm thick for laying floor fnishes in cement mortar (1:3) including taking down existing tiles complete all as specified and as directed byEngineer-in Charge.Note :- The manufacturer\"s test certificate and individual test certificate of tiles must be submitted for approval by the concered authority prior to installation |
| 145 | M&L Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering complete all as specified and directed. |
| 146 | M & L for Rendering 15 mm thick in two layers onbrick or concrete surfaces,first coat 10mm thick in cement mortar1:4 and 2nd coat 5mm thick in cement mortar 1:4 finished even and smooth without using extra cement completeall as specified and directed. |
| 147 | M & L for rendering 15 mm thick in two layers on brick or concrete surfaces, first coat 10 mm thick in CM 1:6 and 2nd coat 5 mm thick in CM 1:6 finished other than fair face without using extra cement complete all as specified and directed. |
| 148 | M&L Preparation of new plastered surfaces wall/ ceiling and applying two coat of white wasing on ceiling/ walls surfaces complete all as specified and directed. |
| 149 | M&L Preparation of new plastered surfaces wallapplying two coat of OBD over a coat of alkali resistant priming paint complete all as specified and directed. |
| 150 | S & F in repairs Brass wire type-I, Gate and shutter, hooks and eyes 150mmcomplete all as specified and directed. |
| 151 | S & F in repairs 100mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 152 | M&L 75mm thick PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate ) as in plinth protection finished even aned fair without using extra cement all as specified. |
| 153 | S&F in CP sink cock with swinging casted round shape spout screwed down screwed for iro pipe in repairs 15mm bore170mm long swivel spout and wall flange (Make : CAT part No QT F2006251 HT F3001251 of CERA or equivalent make of hindware/parryware |
| 154 | S&F sinks with drainage board made of stainless steel lmm thick kitchen orlaboratory with plugs, washers and wastes; including bedding in cementmortar to dwarf wall or including fixing cantilever brackets and connectingunion to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 155 | S&F in repairs Waste coupling of PTMT (half or full threaded) of 40mm bore dia of discharge pipe . (Minimum weight 32mm- 45gms/40mm-60 gms) |
| 156 | M&L Rendering 5mm thickon ceilling ofconcrete surfaces in CM 1:3 complete all as specified and as directed finished even and smooth without using extra cement. |
| 157 | Preparation of new plastered or unplastered surface of ceilling, over a coat of alkali resistant priming paint and applying two coats of white wash on ceilings complete. |
| 158 | S & F in repairs 600mmx450mm bevelled edge mirror ofselected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 159 | S & F in repairs Soap dish, vitreous China white, approximate size 160x 160x90mm complete |
| 160 | S&F in repairs Tubular towel rail brass cromium plated, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed. |
| 161 | S & F in repairs brass mortice lock 4 lever, 100mm, vertical type complete all as specified and directed. |
| 162 | Blocking up the entry of septic tank of the following capacities and pumping out effluent dirty liquid and solid sludge from septic tank including intercepting chambers etc up to bottom collecting sludge and cleaning the septic tank line for reuse and removing the sludge out side to MoD Land and depositing the sludge where directed by local municipal authorities complete all as specified and as directed. Note : The rate inclusive for excavation, returning, filling & ramming of borrow pits for burying of removed sludge under the ground, making good the excavated earth to a true surfaces and transport required and dewatering of efflorecents from septic tank/soak well etc in nearest drain by means of 7.5 HP non clogging diesel driven pump. |
| 163 | 500 users septic tank |
| 164 | 200 users septic tank |
| 165 | 100 users septic tank |
| 166 | 50 users septic tank |
| 167 | 25 users septic tank |
| 168 | 10 users septic tank |
| 169 | Note for item No 162 to 168 :- The unit rate quoted is deemed to be inclusive for the following :- |
| 170 | (a)Solid sludge means bulky mass of sludge which remains at the bottom of septic tank/soakage well after pumping out/taking out sludge water. |
| 171 | (b)Contractors are advised to ascertain the place suitable/earmarked for disposal of sludge/sewage water from local municipality or area controlling authority before quoting their rates. Disposal of waste at suitable place shall be sole responsibility of contractors and no representation or objection in this regard will be entertained at later stage. |
| 172 | (c) The rate included for excavation of borrow pits for burying of removed sludge under the ground, making good the excavated earth to a true surfaces. |
| 173 | (d)Removing of accumulated eartharound septic tank up to 3 m of any width and depth up to 30 cm. cleaning/cutting the grassaround septic tank up to 3 m and removing the grass waste to outside MD land. Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level.Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shall be carefully filled up with moorum/red bajri well rammed and levelled. |
| 174 | (e)The complaints to be rectified within SIX hours on same day. The Delay in rectification of complaint more than Six hours, the penalty will be levied @ Rs.100.00 Per complaint/ day. |
| 175 | (f) In case the nature of job is such that the work cannot be completed within a period of 6 hrs then the same shall be brought to the notice of the GE/Engr-in-Charge and the period for the completion of the complaint shall be decided by the GE/EIC. |
| 176 | M&L Vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts, flushing cistren and flushpipe) and including seat cover for pedestal pattern complete fixed including taking down existing damaged one complete as specified and as directed. |
| 177 | M&L Vitreous china squatting pan \"Orissa\" Pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe ) including provision of lime concrete beddingfixed including taking down existing damaged one complete all as specified and as directed. |
| 178 | M&L PVC (SWR) 110mm bore P Trapincluding taking down existing one complete all as specified and as directed. |
| 179 | M&L PVC (SWR) 110mm bore S Trapincluding taking down existing one complete all as specified and as directed. |
| 180 | M&L PVC (SWR) branch piece single (single Y)75mm bore equal or unequal provided with access doorincluding taking down existing one complete all as specified and as directed. |
| 181 | M&L PVC (SWR) branch piece single (single Y)110mm bore equal or unequal provided with access doorincluding taking down existing one complete all as specified and as directed. |
| 182 | M&L PVC (SWR) 75mm bore junction (single T) equal or unequal provided with access door complete all as specified and as directed. |
| 183 | M&L Cutting salt-glazed stoneware drain pipe 150mm bore in position, including jointing socket end of new pipe to same with packed spun yarn and cement mortar 1:1 and making good, complete all as specified and directed. |
| 184 | M&L Cutting salt-glazed stoneware drain pipe 200 mm bore in position, including jointing socket end of new pipe to same with packed spun yarn and cement mortar 1:1 and making good, complete all as specified and directed. |
| 185 | M&L Cutting salt-glazed stoneware drain pipe 100 mm bore in position, including jointing socket end of new pipe to same with packed spun yarn and cement mortar 1:1 and making good, complete all as specified and directed. |
| 186 | M&L Cleaning/ clearing of sewage line (including manholes) 150 mm to 300 mm dia main line from 1stmanhole onwards bore of any description, underground at any depth, removing any type of blockage including desludging, descaling & decoking of drain as well as manholes with combined high pressure water jetting cum suction (vaccum) type machine mountedon LCV/HCV /LMV/HMV and having facilities of high pressure vaccum and provn of hydraulic through high pressure thermo plastic fiber based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same out side MD land and deposit where the place marked by the local municipality, all as directed by Engr-in-Charge |
| 187 | Note for item No 186 :- The unit rate is deemed to be included for Removing of accumulated earth at sides of drain of any width and depth up to 30 cm. cleaning/cutting the grass around 1 m from drain (both sides) and removing the grass waste to outside MD land. Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level . Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shall be carefully filled up with moorum/red bajri well rammed and levelled. |
| 188 | M & L cleaning of blockage from nahani traps of bath/kitchen in ground floor and upper floors by taking out mud/sand complete all as specified and as directed. |
| 189 | All as per item No. 188 above but cleaning of blockage from Gully trap to 1st manholes in ground floors. |
| 190 | M & L cleaning of blockages from water closets in ground floors/upper floor including re-fixing of lid of door bends etc in position after completion of job all as specified and asdirected. |
| 191 | Note for item No 188 to 190 :-The unit quoted rate is deemed to be included for the following :- |
| 192 | (a)Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level.Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shall be made good carefully by filled up with moorum/red bajri well rammed and levelled. |
| 193 | (b)Safaiwala shall report to concerned JE /AGE B&Rin service centredaily including Sunday and holiday and get the job card for carrying out the work. The Job card shall be returnedto concerned JE/AGE duly signed by the users as a token of completion of job. |
| 194 | (c)Cleaning, removal of silts/wastage of organic or inorganic materialsof Sewage line of100mm to 450mm bore up to 1st manhole, in between manholes, GT Chamber, etc to maintain sewage system functional all working days including Sundays and holidays along with necessary T&P i.e flexible rods, cleaning pumps and safety kits etc. |
| 195 | (d)The complaints to be rectified within six hours on same day. The Delay in rectification of complaint more than Six hours, the penalty will be levied @ Rs.100.00 Per complaint/ day. |
| 196 | (e)In case the nature of job is such that the work cannot be completed within a period of 6 hrs then the same shall be brought to the notice of the GE/Engr-in-Charge and the period for the completion of the complaint shall be decided by the GE/EIC. |
| 197 | M&L PVC (SWR) floor trap 75mm dia of outlet pipe, plain with grating including jointing with solvent cement including taking down existing damaged one complete all as specified and as directed. |
| 198 | M&L PVC (SWR) gullytrap 125/110 mm dia of outlet pipe,including jointing with solvent cement including taking down existing damaged one complete all as specified and as directed. |
| 199 | Taking out/pumping contaminated sewage water from Grease trapincl inlet/outlet chamber after plugging incoming sewage line, through suction(vaccum) type machine mounted on LMV/HMV and facility of high pressure vaccum and removing and dumping off the sameout side MD land/contonment at the place marked for the purpose by local municipality or the authority controling the area complete all as specified and as directed. |
| 200 | M&L Cleaning and Removing silt, grit , mud and other materials from covered drain in foul condition including removing materials from the site to outside MD land including necessary removing cover slabs and replacing after cleaning complete area including making good any damages complete all as specified and as directed. |
| 201 | M&L Joist, channel, angles or tee sections fixed independently, without connection platessFe-290 Gde E-165 etc complete all as specified and as directed. |
| 202 | M&L in repairs stack clamps out of 50 mm x 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays towall or roof for 75 mm bore pipe complete all as specified and directed. |
| 203 | M&L Applying two coats of synthetic enamel paint over a coat of red oxide primer includingpreparation of new or previously untreated steel surfaces of any description exc 10cm width or girth complete all as specified and as directed. |
| 204 | Note for item No 203:-(a) All synthetic enamel paint, plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified. |
| 205 | (b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works. |
| 206 | (c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE. |
| 207 | (d)Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite) |
| 208 | (e )Unless otherwise specified the tints of paint shall be as approved by the GE |
| 209 | (f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval. |
| 210 | (g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge. |
| 211 | (h) No hair marks from the brushor clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory. |
| 212 | M&L Low density polyethylene (LDPE) pipes 32 mm bore of pressure rating 6 kgf/sqcm for sink/ wash basin in repairs complete all as specified and as directed. |
| 213 | M&L Cutting into existing manholes for connecting new drains, making good pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4 type B-1 using 20mm graded stone aggregate) smooth finished and reforming benching as required 150mm internal bore, complete all as specified and as directed. |
| 214 | M&L Salt-glazed stoneware drain pipes, 200 mm bore, laid in trenches and jointed as specified, complete including taking down existing damaged pipe,of any size complete all as specified and as directed. |
| 215 | M&L Plain cement concrete (1:3:6) type C2 (40 mm graded stone aggregate)asconcrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes ofsize 200mm bore of pipe, complete all as specified and as directed. |
| 216 | M&L Salt-glazed stoneware drain pipes, 150mm bore, laid in trenches and jointed as specified, complete including taking down existing damaged pipe,of any size complete all as specified and as directed. |
| 217 | M&L Plain cement concrete (1:3:6) type C2 (40 mm graded stone aggregate)asconcrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes ofsize 150 mm bore of pipe, complete all as specified and as directed. |
| 218 | Excavation in trenchesin foul position n.exc 1.5m width and n.exc 1.5 m depth and getting out in hard/dense soil complete all as specifiedand as directed |
| 219 | Excavation in trenchesin foul position n.exc 1.5m width and exc 1.5 m depth but not exc 3mtr and getting out in hard/dense soil, complete all as specifiedand as directed. |
| 220 | Note for Item No 218 & 219:- (a) Excavating either straight or curved on plan |
| 221 | (b) Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre aboveground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance except in the case of surface dressing which includes for all the foregoing except clearing away of trees |
| 222 | (c) Bailing out, pumping out or otherwise removing all water which may accumulate in the excavations |
| 223 | (d) Setting out the work profiles, etc. as well as for all tools and plant |
| 224 | (e) All materials and labour required protecting against risk of accidents, etc. |
| 225 | (f) Watching and lighting, whenever necessary. |
| 226 | (g) Forming (or leaving) ‘Dead men’ or ‘Telltales’ in borrow pits and their removal after record of measurements where required |
| 227 | (h) Forming (or leaving) steps in sides of deep excavations and their removal or covering up, after record of measurements |
| 228 | (j) Excavation for insertion of planking and strutting where required |
| 229 | (k) Removing slips or falls in excavations |
| 230 | (l) Authorised battering or benching of excavations |
| 231 | (m) Slinging or supporting pipes, electric cables, etc. met with during excavation |
| 232 | M&L Providing cement concrete type C1, 1:3:6 (using 20mm graded crushed stone aggregate) as in surface channels and drains complete all as specifiedand as directed. |
| 233 | Extra for forming fair finished drain or channel of 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed. |
| 234 | M&L Rendering 15 mm thick in two layers onbrick or stone or concrete surfaces,first coat 10mm thick in cement mortar1:4 and 2nd coat 5mm thick in cement mortar1:4 mixed with water proofing compound as per manufacturer instructionsfinished even and smooth without using extra cement completeall as specified and as directed. |
| 235 | Note for Item No 234 :- (a) Water proofing compound shall be measured and paid under suppy only. The labour cost for mixing the WPC as per the manufacturer\"s instruction shall be deemed to be inclusive in the quoted rate. |
| 236 | (b) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account. |
| 237 | M&L Precast RCC 1:2:4, Type B–1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc], chullah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed. |
| 238 | S&F High strength corrosion resistant TMT bars of Grade Fe–500Dof 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified. |
| 239 | M&L 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ringjoints fixed to wallincluding taking down existing PVC Rain Water Pipes (any size) along with all fittings heads bends etc complete all as specified and as directed. |
| 240 | M&L Salt-glazed stoneware drain pipes, 100mm bore, laid in trenches and jointed as specified, complete including taking down existing damaged pipe any size all as specified and as directed. |
| 241 | M&L Plain cement concrete (1:3:6) type C2 (40 mm graded stone aggregate)asconcrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes ofsize 100mm bore of pipe, complete all as specified and as directed. |
| 242 | M&L PVC (SWR) bends any radius 75 mm dia fixed to wallcomplete all as specified and as directed. |
AI Tender Summary
Tender Timeline
Apr 10, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMay 08, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 09, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer