Kasauli
08-05-2023

Tender Details

Tender For Welcome Maintenance Of Md Accn At Mil Stn Dagshai Under Ge Kasauli.---2 M & L Rendering 15mm thick onfair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement completeincluding taking down cement plaster on brick or stone wall and racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. all as specifiedand directed. 3 M & L Rendering 15mm thick onfair faces of brick work or concrete surfaces in CM 1:4finished even and smooth without using extra cement completeincluding taking down cement plaster on brick or stone wall and racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. all as specifiedand directed. 4 M&L for rendering 10mmthick in cement mortar 1:3 on ceiling brick/concrete surfaces w/o using extra cement including taking down cement plaster onCeillingand racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. all as specifiedand directed. 5 M&L for preparation of plastered or unplastered old surfaces of walls andabove but one coat of cement based paint on walls complete all as specified and directed. 6 M&L preparation of new plastered surface of wall or complete removal of existing treatment in old plastered wall surfacesby washing, rubbing down and stopping of previously treated surfaces and applying two coat of cement base paint over a coat of primeron walls complete all as specified and directed. 7 M&L forfor applying1 mm thick wall careputty of old decorated plastered or unplasteredsurfaces of wallcomplete all as specified and directed. 8 M&L for preparation of plastered or unplastered old surfaces of walls and applying one coat of oil bound distemper of any approved tint complete all as specified and directed. 9 M&L preparation of new plastered surface of wall or complete removal of existing treatment in old plastered wall surfacesby washing, rubbing down and stopping of previously treated surfaces and applying two coat of oil bound distemper of any approved tint over a coat of primer complete all as specified and directed. 10 M&L for preparation of oldplastered ceiling surfaces orAC plain building board surfaces and applyingone coat of oil bound distebmer complete all as specified and directed 11 M & L for preparation of old painted wooden surfaces of any description position and location not otherwise described over 10cms width or girth and applying one coat of synthetic enamel paint (ordinary tint) all as specified and as directed. 12 All as per item No 10.00above butapplying two coat of synthetic enamel paintcomplete all as specified and directed 13 M&L preparation of old painted steel surfaces exc 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed 14 All as per itme No 12.00 above buttwo coat of synthetic enamel paint complete all as specified and directed 15 M&L preparation of new plastered ceiling surfacesor complete removal of existing treatment in old plastered ceiling surfacesby washing, rubbing down and stopping of previously treated surfaces and applying two coat of white washon wall complete all as speciifed and directed. 16 M&L for preparation of oldplastered ceiling surfaces orAC plain building board surfaces and applying one coat of white wash complete all as specified and directed. 17 M&L preparation of old painted NTP/CGI/PGI or other steel roof surfaces, eaves and gutters etc exc 10 cm width or girth and applying one coat of synthetic enamel paint of any tint as approved complete all as specified 18 ditto as per item No 16.00 above complete removal of existing treatment and applying two coat of synthetic enamel paint over a coat of primer 19 M&L preparation of old painted plastered wallsurfaces and applying one coats of synthetic enamel paint of approved tint complete all as specified 20 All as per item No 18.00butapplying two coat of synthetic enamel paint complete all as specified and directed 21 M&L for preparation of plastered or unplastered old surfaces of wallsand applying one coat of exterior emulsion paint complete all as specified and directed 22 M&L preparation of new plastered surface of wall or complete removal of existing treatment in old plastered wall surfacesby washing, rubbing down and stopping of previously treated surfaces and applying two coat of exterior emulsion paint over a coat of primer of approved tint and make complete all as specified and directed. 23 M&L disconnecting existing over head steel/PVC water tanks, setting aside (or lowering, if required) for repairs, cleaning etc and hosting if required, reconnecting and refixing in position including cleaning and removing all a scale and dirt etc from tanks and from mouth of circulating pipes etc capacity exc 250 ltrs but n. exc 500 ltrs complete all as specified and as directed. 24 All as per item No 22.00 above but exc 500 Ltrs and n exc 1000 Ltrs capacity complete all as specified and directed 25 Writing letters or figures ( block , Roman , Italic , indian) n.exc 30cm height all as specified and directed. 26 Writing Stops , commas, short lines dashes hyphens,brackets etc all as specified and directed. 27 Taking down chowkats or frames n.exc. 1.5 Sqm each but withouttaking off shutters from the frames 28 Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 sqm each but withouttaking off shutters from the frames 29 Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each 30 S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing. 31 S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. ? 32 S & F 35 mm thick factory made, 2nd class hard wood,plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated etc complete, all as specified . 33 S & F 35 mm thick 2nd class hard wood glazed and skelton shutter open rebated and prepared to receive glass ,gauge etc ( without sash bar)edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8 clause 8.24(a), supplied and fitted to chowkats. 34 M&L 2nd class hardwood as in plain, solid straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed 35 M & L for two coats of synthetic enamel paint over coat of pink primer on newwooden surfaces of any description not otherwise described over 10 Cm width or girth including preparation of surfaces complete all as specified and as directed by the Engineer-in-Charge. 36 M&L for RCC 1:2:4 type B0 (using 12.5 mm graded stone aggas in chajja at any height complete including demolition of RCC in chajjas including necessary scaffolding up to a height of 12 mterall as specified and as directed. 37 Use and waste form work to chajjas chulla hoods troughs and similar items including edges at any height rough finished flat surface complete all as specified & directed. 38 M&L for providing fabricating placing in position new reinforcement of any size as per site requirement including securing and anchoring and drilling holes inserting the ends and welding if required etc complete all as specified and dircted(Dowel pins willl not paid seperately) 39 S&Fextruded aluminium alloy handles of size 150 mm fabricated type omplete all as specified and asdirected. 40 S&F200 mm aluminium anodised barrel tower bolts of extruded section etc complete all asdirected. 41 S&F 100mm mild steelbutt hinges, cold rolled medium weight. 42 S & Ffor galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed by the Engineer-in-Charge. 43 S&F 250 mm aluminium alloy anodised sliding door bolt with hasp and staple(bolt type) etc complete all as directed. 44 M & Lfor coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment all as specified. 45 Material and labour for Glazed ceramic coloured tiles in vertical surfaces exc 0.08sqm and n exc 0.16sqm, 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match with and including 10mm thick backing coat on vertical surfaces of wall in cement mortar 1:4 complete all as specified and as directed. 46 M&L for 16 to 18 mm thick granite stone machine cut (table rubbed & polished) in one piece as in steps,jambs,pillars,windows cills,cooking platformand similar work bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match the shade of granite stone including grinding and polishing including making hole in platform complete all as specified. 47 Demolition stone slabs or tilesof any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified. 48 S&F in repair 15mm bore angle cock, chromium plated, brass, fancy type, screwed both ends for iron pipe or for union etc complete all as specified and directed. 49 S&F in repair 15mm bore PVC connection with brass nut of length 450mm etc complete all as specified and as directed. 50 S&F in repair 15mm bore Bib taps, chromiumplated cast copper alloy, fency type with crutch or butter fly handle, screwed down for iron pipe or for brass ferrule etc complete all as specified and directed. 51 S&F in repairs PVC waste down pipe 32 mm boreetc complete all as specified and directed. 52 S&Fin repairs 32mm chromium platecoupling for WHB complete all as specified and directed. 53 S&Fin repairs 40mm chromium plated wastecoupling for kithen sink complete all as specified and directed. 54 S & F in repair for 15mm bore pillar tap fancy type, cast copper alloy chromium plated screwed down, high pressure with crutch or butter fly handle etccomplete all as specified and directed. 55 S&F in repair bevelled edged mirror of size 600mmx450mm of selected quality mounted on6mm thick ply or of PVC frame fixed to wall with screw and rawl plugs complete all as specified and directed. 56 S&F in repair 15 mm bore brass Chromium plated wall/basin/sink mixerfor mixing hot & cold water screwed down for iron pipe etc complete all as specified. 57 S & F in repair CP soap dishfixed with and including chromium plated brass screws and wooden/plastic cleatscomplete all as specified and as directed by the Engineer-in-Charge 58 S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm longcomplete all as specified and as directed. 59 S&F in repair CP toilet paper holder all as specified and as directed. 60 S&F in repair Towel rail 600mm long chromium plated fixed in and including chromium plated brass screws and wooden/plastic cleats etc complete all as specified. 61 S&F as in repair fixing WC Orissa pattern of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) includung provision of lime concrete beddingand PVC S trap of 110 mm diaetc complete all as specified and directed by Engr-in-Charge. 62 S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet,ball valve, float and handle including brackets 10 Ltrs capacity complete all as specified complete all as specified and directed by Engr-in-Charge 63 S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts,) complete incl making good to floor to match with adjoining surfaces including plastic water closet seat cover white closed pattern with flat bottom mild steel chromium plated of aluminium hinging device etc completeall as directed by Engr-in-Charge 64 S&F for 15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs etc complete all as specified. Including taking up or down steel tubing and connections upto 15mm bore. 65 S&F for 20 mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs etc complete all as specified. Including taking up or down steel tubing and connections upto 20 mm bore. 66 M & L for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including taking down old unserviceble PVC water tank all as specified in SSR Part-I completedand asdirected by the Engr-in-Charge 67 M & L for 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including taking down old unserviceble PVC water tank all as specified in SSR Part-I completedand asdirected by the Engr-in-Charge 68 S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to laid in trenches or in floors/wall complete all as specified and as directed by the Engineer-in-Charge 69 S & F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/wallcomplete all as specified and as directed by the Engineer-in-Charge 70 S&F PVC(SWR) bend 110mm dia bore complete all as specified and directed by Engr-in-Charge 71 S&F PVC(SWR) bend 75 mm dia bore complete all as specified and directed by Engr-in-Charge 72 S & F in repair 100 mm dia CP grating plain including jointing with solvent cement. 73 S&F in repair 75 mm dia PVC(SWR) floor trap, with grating including jointing with solvent cement etc complete all as specified. 74 S&F in repair chromium plated health faucets (hand held shower type) with shut off valve (thumb or push button type) to allow controlled and continuous flow of water with adequate length and wall mounted pedestal for hanging the faucet etc complete. 75 S&F in repairs sinks with drainage board made of stainless steel1 mm thick kitchen or laboratorywith plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm etc complete all as specified. 76 S&F aluminium anodised 4 pin cloth hook hangerfixed to wall complete all as specified and as directed. 77 Dismantling timber scantlings 40 sqcm and under in section, in any position framed / Unframed work complete all as specified by the Engr-in-Charge 78 Dismantling wrought iron or mild steel work of any description any position not otherwise provided complete all as specified 79 M & L for 6 mmPlywood, grade BWR, type BB, fixed with screws to timber frame work all as specified including dsmantling ofwall andceiling board (fibre, pulp, insulation, etc) or insulationboards etc,, any thickness etc. including cover fillets complete 80 M&L for 18/19 mmblock boards,interior grade, fixed with screws to timber frame work complete all as specified. including dsmantling ofwall andceiling board (fibre, pulp, insulation, etc) or insulationboards etc,, any thickness etc. including cover fillets complete 81 M&L 6mm thick teak wood lipping for block board or veneered plywood 18/19mm thick, fixed with nails in repairscomplete all as specified and directed. 82 Material and Labour for 2nd class hard wood (Hollock) Plain fillets Exc6& n. exc13 sq.cm square, rectangular or triangular in section, clean sawn, secured with nails or brads,complete including dismantling timber scantlings 40 sqcm and under in section, in any position framed / Unframed work complete all as specified by the Engr-in-Chargeall as specified. 83 S&F for 0.9 mm thick decorative laminate type 1 of surface finish colour andpattern as approved, fixed with approved adhesive as per specified and as directed 84 M& L forPVC edge strip of 18/19 mm wide,colour andpattern as approved fixed withadhesive as per specified and as directed 85 S&F in repair Continuous (piano) hinges,mild steel, bright finish or elec trogalvanisedbright finish width of flaps(when open) 30 mm complete all as specified. 86 S&F 100 mm long extruded stainless steelhandle fabricated type anodised, complete all as specified. 87 S&F Hasp and staple, safety type,of aluminium anodised including bolt to hinge plate and fixed with screws 100 mm size complete all as specified. 88 S&Fmagnetic steel stopper catcher holder for cup board of approprite shape and size all as directed. 89 Material and Labour Framed work such as grills, gratings,railingetc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165complete all as specified. 90 Material and Labour for Welded steel wire fabric n.exc 4 Kg/Sqm suppliedand fixedcomplete to wood or steel members complete all as specified. 91 M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified & directed complete all as specified and directed by Engr-in-Charge. 92 M&Lfor cement concrete 1:4:8 type D-2( using 40mm graded stone aggregate) as in sub base floor and infoundationincluding necessary form work complete all as specified and directed.including demolition of cement concrete (unreinforced) in ground floors and pavingsnot exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials ) 93 M&LforPCCType B1 1: 2:4 (20 mm graded stone aggregate ) Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges as in coping ,kneelers , appex stone, copingetc .including demolition of cement concrete (unreinforced) in ground floors and pavingsnot exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials ) 94 M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement andno pigment set and jointed in neat cement slurry over 20 mm thick cement screed in CM 1:6 all as specified.all as specified and as directed 95 M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment set and jointed in neat cement slurry over 20 mm thick cement screed in CM 1:6 all as specified.all as specified and as directed 96 M&L for Chequered cement concrete tiles 30 cmx 30cm x 25 mm thick, with grey cement and pigment set jointed and pointed in neat cement slurry over and including 20 mm thick screed bed in CM 1:6in floors with grey cement and pigments complete all as specified and directed 97 Taking down carefully any type of battens or conduit point wiringwith or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge. 98 Material and labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed, copper conductor cable in and incl PVC casing -n-caping of any size/dia medium grade complete with all accessories/fittings, brass screws, washer etc and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded FRLSH copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings :- 99 One light /Exhaust fan point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed. 100 One bell point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed. 101 One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed. 102 One 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed. 103 One two way point controlled by two, two way switches 06 Amps complete all as specified and directed. 104 All as per serial item No 97.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06 Amps socket outlet point on independent board complete all as specified and directed. 105 All as per serial item No 97.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed. 106 Material & labour forpoint wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSHPVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc,and including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded FRLSH copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings :- 107 One light / Exhaust fan point controlled by one, one way switch 06 Amps complete all as specified and directed. 108 One bell point controlled by one, one way switch 06 Amps complete all as specified and directed. 109 One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed. 110 One 3 pin,06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed. 111 One two way point controlled by two, two way switches 06 Amps complete all as specified and directed. 112 All as per serial item No 99.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06 Amps socket outlet point on independent board complete all as specified and directed. 113 All as per serial item No 99.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable forone 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed. 114 Supply & fixing modular switch 1module, 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge 115 Supply & fixing socket, 06 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge 116 Supply & fixing modular switch 1module,16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge 117 Supply & fixing socket, 06/16 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge 118 Supply and fixing modular bell push 1module, 06 amps , 240 volts all as directed by Engr-in-Charge 119 Supply and fixing door bell ding dong type , 240 volts AC 120 Supply & fixing modular switch 1module, 06 Amps single pole, two way 240 volts complete all as specified & directed. by Engr-in-Charge 121 Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed by Engr-in-Charge 122 Supply and fix LED lamp 9/10 watt complete all as specified and directed. 123 Supply & fixing in repair LED tube light batten fitting 18/20W, (single Side Connection) including LED Rod including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed. 124 Supply & fixing/fixing in repair LED mirror light 10W including rod complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed. 125 Supply and fixing in repair of 9/10 W LED bulk head luminairies incl LED light with clear prismatic diffuser,driver holder connecting up with three core flexible copper conductor cable of suitable sizeincluding all acessories for fixing on wall all as specified and directed by Engr-in-Charge. 126 Supply and fixing wall mounted decorative fancy light fitting stylo (Round)suitable for 14 watts LED lamp including provisson of fixing on wall with all items required for fixing all as specified and directed by Engr-in-Charge. 127 Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge. 128 Taking down carefully unserviceable Sub main wiring of any size and type, removing material from site for taking credit and making good the disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed by Engineer - in - Charge. 129 Material and labour for sub main wiring with 2x4 Sqmm nominal cross sectional area (two single core cable of 4 Sqmm for Phase and neutral + o1 single core cable of 2.5 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. 130 Ditto all as item No 116.00 above, but by using two single core cable of 6 Sqmm for Phase and neutral + 1 single core cable of 4 Sqmm for earth wire. 131 Taking down carefully unserviceable distribution board of any capacity including wooden board and making good the disturbed surfaces of walls, etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge. 132 Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge. 133 All as per item No 119.00, herein before but of size 08 way SPN. 134 All as per item No 119.00, herein before but of size 12 way SPN. 135 Supply and fixing MCB, SP, AC, 240 volts C series capacity of 06 to 32 Amps, 10kA and making connections with suitable thimble complete all as specified & directed. 136 Supply & fixing MCB, DP (Double Pole), AC, 240 volts, C series capacity 20 Amps to 32 Amps10kA and making connections with suitable thimble complete all as specified & directed. 137 Supply & fixing MCB, DP (Double Pole), AC, 240 volts, C series capacity 40 Amps to 63 Amps10kA and making connections with suitable thimble complete all as specified & directed. 138 Supply and fixing sheet metal enclosure, Triple pole and neutral AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection including provision of four pole 100 Amp isolator and MCBs of cap 20 to 40 Amps as incomer with metal double door and flush to wall including all cutting etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge. 139 Supply & fix Isolator 4 Pole C series 100 amps capacity AC 415 V,10kA complete all as specified and directed. 140 M & l for Sheet metal enclosure fiiting on wall and making the connection with provison of MCCB 4 Pole 100 Amps 25 KA, 415 volts , 50 Hz ,thimble/lugs, aslo including all nuts bolts required for fixing all as specified and directed by Engineer - in - Charge 141 Supply & fixing industrial type SPN enclosure with a two pin and earth plug and socket complete with and including 32 Amps MCB, single pole, AC, 240 volts and flush to wall including all cuttings & chases etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge. 142 Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete all as specified and directed. 143 Taking down carefully under ground cable of any size and making good to disturbed surface as per existing complete all as specified and directed. 144 Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 25 Sqmm 3.5 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed. 145 -ditto- all as per item No 131.00,but 16 Sqmm 2 core 146 -ditto- all as per item No 131.00,but 10 Sqmm 2 core 147 Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in hard/dense soil and gating out in hard/dense soil complete all as specified and directed. 148 Supply / laying and fixing 50 mm bore HDPE pipe PN10 with all fittings laid in trenches for cable protection complete all as specified and directed. 149 Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft / loose soil complete all as specified and directed. 150 Removing surplus excavated materials n.exc. 50 Mtr and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete all as specified and directed. 151 Taking down the geyser of 25/ 50 ltr capacities from the site after disconnecting the water connection, electric connection, opening the geyser assembly and descalling deposited in the inner container and outlet water pipe set complete all as directed by Engineer-in-Charge. (Note:- Replacement of Unserviceable bolts, rubber real, ring nuts, washers to be included in the rate quoted by tenderer. However supply & fix or material & labour for GI fittings and other connected works shall be measured and paid for separately under respective items of schedule ‘A’ here in after) :- 152 Supply & fix in repair of geyser syphon assembly steel plate with nuts and bolts, washers, clamps and rubber ring any Make of geyser, for 25/50 ltr capacity of Geysers. 153 Supply & fix in repair of thermostatic switch 11 long ISI marked complete with electric connection suitable for geyserany Make complete all as specified and directed. 154 Supply & fix in repair ofgeyser element 1.5 /2.0 KW capacity with rubber ring Round/trangular type complete with clamps, nuts and bolts washers etc for geysers ISI marked (any Make) completeall as specified and directed. 155 Supply and fix Non return valve 15mm dia made of bronze ISI marked heavy duty fixed in repairs complete all as directed by Engineer-in-Charge. 156 Supply & fix (in repairs) 15mm dia PVCconnection 450 mm long , suitable for hot water supply ,complete with 2 Nosbrass nuts complete all as specified and directed. 157 Supply & fix (in repairs) 15mm dia PVCconnection 450 mm long , suitable for cold water supply ,complete with 2 Nosbrass nuts complete all as specified and directed. 158 Supply & fix in repairs of Zebra fastner of size 12x100 mm complete all as specified and directed . 159 Taking down of the following accessories in repair works including all necessary fitting items such as screw, nut and bolt, connector, flexible copper wire 1.5/2.5Sqmm size etc including cheking/testing complete as directed by Engr-in-Charge :- 160 Supply & fixing modular switch 1module, 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge 161 Supply & fixing socket, 06 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge 162 Supply & fixing modular switch 1module,16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge 163 Supply & fixing socket, 06/16 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge 164 Supply and fix in repair lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed by Engr-in-Charge 165 Supply and fix in repairwhite cover plate with frame 1 module complete all as specified & directed by Engr-in-Charge 166 Supply and fix in repairwhite cover plate with frame 2 module complete all as specified & directed by Engr-in-Charge 167 Supply and fix in repairwhite cover plate with frame 3 module complete all as specified & directed by Engr-in-Charge 168 Supply and fix in repairwhite cover plate with frame 4 module complete all as specified & directed by Engr-in-Charge 169 Supply and fix in repairwhite cover plate with frame 6 module complete all as specified & directed by Engr-in-Charge 170 Supply and fix in repairwhite cover plate with frame 8 module complete all as specified & directed by Engr-in-Charge 171 Supply and fix in repairmetal flush box 1/2 module complete all as specified & directed by Engr-in-Charge 172 Supply and fix in repairmetal flush box2 module complete all as specified & directed by Engr-in-Charge 173 Supply and fix in repair metal flush box3 module complete all as specified & directed by Engr-in-Charge 174 Supply and fix in repairmetal flush box4 module complete all as specified & directed by Engr-in-Charge 175 Supply and fix in repair metal flush box6 module complete all as specified & directed by Engr-in-Charge 176 Supply and fix in repair modular switch socket combination16 A, 6 pin, 3 module complete all as specified & directed by Engr-in-Charge 177 Supply and fix in repair modular switch socket outlet 03 pin 06 A, flush type complete all as specified & directed by Engr-in-Charge 178 Supply and fix in repair modular switch socket outlet 03 pin 16 A, flush type complete all as specified & directed by Engr-in-Charge 179 S&F in Replacement Exhaust Fan 250mm plastic body , 1400 RPM with air delivery 1050 CMH including and taking down unserviceable, complete all as specified and directed 180 S&F in Replacement Exhaust Fan 300mm Sweep metal body (Heavy Duty), 1400 RPM with air delivery 1050 CMH including and taking down unserviceable, complete all as specified and directed. 181 M&L for electric insulation tape heavy duty complete all as per specifed and directed. 182 S&F self ballasted LED Retrofit Bulb 5 Star Bulbs 12 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed. 183 Supplying and fixing Meter Box made up of BWR plywood board of 8mm thickness covered with 3mm thick laminated sheet, size of the box shall be of 900mm x 450mm x 250mm including provision of shutters with lock and clasp complete and fixed as directed by Engr-in-Charge. 184 Amount of credit of Rs. 31871.10 for retrived old material as mentioned in Schedule A section-II of tender document in pdf form, will be deducted offline while acceptence of tender.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-05-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: WELCOME MAINT OF MD ACCN AT MIL STN DAGSHAI UNDER GE KASAULI.
Sl. No. Item Description
1Schedule "A" Section - I
2M & L Rendering 15mm thick onfair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement completeincluding taking down cement plaster on brick or stone wall and racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. all as specifiedand directed.
3M & L Rendering 15mm thick onfair faces of brick work or concrete surfaces in CM 1:4finished even and smooth without using extra cement completeincluding taking down cement plaster on brick or stone wall and racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. all as specifiedand directed.
4M&L for rendering 10mmthick in cement mortar 1:3 on ceiling brick/concrete surfaces w/o using extra cement including taking down cement plaster onCeillingand racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. all as specifiedand directed.
5M&L for preparation of plastered or unplastered old surfaces of walls andabove but one coat of cement based paint on walls complete all as specified and directed.
6M&L preparation of new plastered surface of wall or complete removal of existing treatment in old plastered wall surfacesby washing, rubbing down and stopping of previously treated surfaces and applying two coat of cement base paint over a coat of primeron walls complete all as specified and directed.
7M&L forfor applying1 mm thick wall careputty of old decorated plastered or unplasteredsurfaces of wallcomplete all as specified and directed.
8M&L for preparation of plastered or unplastered old surfaces of walls and applying one coat of oil bound distemper of any approved tint complete all as specified and directed.
9M&L preparation of new plastered surface of wall or complete removal of existing treatment in old plastered wall surfacesby washing, rubbing down and stopping of previously treated surfaces and applying two coat of oil bound distemper of any approved tint over a coat of primer complete all as specified and directed.
10M&L for preparation of oldplastered ceiling surfaces orAC plain building board surfaces and applyingone coat of oil bound distebmer complete all as specified and directed
11M & L for preparation of old painted wooden surfaces of any description position and location not otherwise described over 10cms width or girth and applying one coat of synthetic enamel paint (ordinary tint) all as specified and as directed.
12All as per item No 10.00above butapplying two coat of synthetic enamel paintcomplete all as specified and directed
13M&L preparation of old painted steel surfaces exc 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
14All as per itme No 12.00 above buttwo coat of synthetic enamel paint complete all as specified and directed
15M&L preparation of new plastered ceiling surfacesor complete removal of existing treatment in old plastered ceiling surfacesby washing, rubbing down and stopping of previously treated surfaces and applying two coat of white washon wall complete all as speciifed and directed.
16M&L for preparation of oldplastered ceiling surfaces orAC plain building board surfaces and applying one coat of white wash complete all as specified and directed.
17M&L preparation of old painted NTP/CGI/PGI or other steel roof surfaces, eaves and gutters etc exc 10 cm width or girth and applying one coat of synthetic enamel paint of any tint as approved complete all as specified
18ditto as per item No 16.00 above complete removal of existing treatment and applying two coat of synthetic enamel paint over a coat of primer
19M&L preparation of old painted plastered wallsurfaces and applying one coats of synthetic enamel paint of approved tint complete all as specified
20All as per item No 18.00butapplying two coat of synthetic enamel paint complete all as specified and directed
21M&L for preparation of plastered or unplastered old surfaces of wallsand applying one coat of exterior emulsion paint complete all as specified and directed
22M&L preparation of new plastered surface of wall or complete removal of existing treatment in old plastered wall surfacesby washing, rubbing down and stopping of previously treated surfaces and applying two coat of exterior emulsion paint over a coat of primer of approved tint and make complete all as specified and directed.
23M&L disconnecting existing over head steel/PVC water tanks, setting aside (or lowering, if required) for repairs, cleaning etc and hosting if required, reconnecting and refixing in position including cleaning and removing all a scale and dirt etc from tanks and from mouth of circulating pipes etc capacity exc 250 ltrs but n. exc 500 ltrs complete all as specified and as directed.
24All as per item No 22.00 above but exc 500 Ltrs and n exc 1000 Ltrs capacity complete all as specified and directed
25Writing letters or figures ( block , Roman , Italic , indian) n.exc 30cm height all as specified and directed.
26Writing Stops , commas, short lines dashes hyphens,brackets etc all as specified and directed.
27Taking down chowkats or frames n.exc. 1.5 Sqm each but withouttaking off shutters from the frames
28Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 sqm each but withouttaking off shutters from the frames
29Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each
30S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
31S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. ?
32S & F 35 mm thick factory made, 2nd class hard wood,plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated etc complete, all as specified .
33S & F 35 mm thick 2nd class hard wood glazed and skelton shutter open rebated and prepared to receive glass ,gauge etc ( without sash bar)edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8 clause 8.24(a), supplied and fitted to chowkats.
34M&L 2nd class hardwood as in plain, solid straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and as directed
35M & L for two coats of synthetic enamel paint over coat of pink primer on newwooden surfaces of any description not otherwise described over 10 Cm width or girth including preparation of surfaces complete all as specified and as directed by the Engineer-in-Charge.
36M&L for RCC 1:2:4 type B0 (using 12.5 mm graded stone aggas in chajja at any height complete including demolition of RCC in chajjas including necessary scaffolding up to a height of 12 mterall as specified and as directed.
37Use and waste form work to chajjas chulla hoods troughs and similar items including edges at any height rough finished flat surface complete all as specified & directed.
38M&L for providing fabricating placing in position new reinforcement of any size as per site requirement including securing and anchoring and drilling holes inserting the ends and welding if required etc complete all as specified and dircted(Dowel pins willl not paid seperately)
39S&Fextruded aluminium alloy handles of size 150 mm fabricated type omplete all as specified and asdirected.
40S&F200 mm aluminium anodised barrel tower bolts of extruded section etc complete all asdirected.
41S&F 100mm mild steelbutt hinges, cold rolled medium weight.
42S & Ffor galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed by the Engineer-in-Charge.
43S&F 250 mm aluminium alloy anodised sliding door bolt with hasp and staple(bolt type) etc complete all as directed.
44M & Lfor coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment all as specified.
45Material and labour for Glazed ceramic coloured tiles in vertical surfaces exc 0.08sqm and n exc 0.16sqm, 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match with and including 10mm thick backing coat on vertical surfaces of wall in cement mortar 1:4 complete all as specified and as directed.
46M&L for 16 to 18 mm thick granite stone machine cut (table rubbed & polished) in one piece as in steps,jambs,pillars,windows cills,cooking platformand similar work bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match the shade of granite stone including grinding and polishing including making hole in platform complete all as specified.
47Demolition stone slabs or tilesof any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified.
48S&F in repair 15mm bore angle cock, chromium plated, brass, fancy type, screwed both ends for iron pipe or for union etc complete all as specified and directed.
49S&F in repair 15mm bore PVC connection with brass nut of length 450mm etc complete all as specified and as directed.
50S&F in repair 15mm bore Bib taps, chromiumplated cast copper alloy, fency type with crutch or butter fly handle, screwed down for iron pipe or for brass ferrule etc complete all as specified and directed.
51S&F in repairs PVC waste down pipe 32 mm boreetc complete all as specified and directed.
52S&Fin repairs 32mm chromium platecoupling for WHB complete all as specified and directed.
53S&Fin repairs 40mm chromium plated wastecoupling for kithen sink complete all as specified and directed.
54S & F in repair for 15mm bore pillar tap fancy type, cast copper alloy chromium plated screwed down, high pressure with crutch or butter fly handle etccomplete all as specified and directed.
55S&F in repair bevelled edged mirror of size 600mmx450mm of selected quality mounted on6mm thick ply or of PVC frame fixed to wall with screw and rawl plugs complete all as specified and directed.
56S&F in repair 15 mm bore brass Chromium plated wall/basin/sink mixerfor mixing hot & cold water screwed down for iron pipe etc complete all as specified.
57S & F in repair CP soap dishfixed with and including chromium plated brass screws and wooden/plastic cleatscomplete all as specified and as directed by the Engineer-in-Charge
58S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm longcomplete all as specified and as directed.
59S&F in repair CP toilet paper holder all as specified and as directed.
60S&F in repair Towel rail 600mm long chromium plated fixed in and including chromium plated brass screws and wooden/plastic cleats etc complete all as specified.
61S&F as in repair fixing WC Orissa pattern of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) includung provision of lime concrete beddingand PVC S trap of 110 mm diaetc complete all as specified and directed by Engr-in-Charge.
62S&F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet,ball valve, float and handle including brackets 10 Ltrs capacity complete all as specified complete all as specified and directed by Engr-in-Charge
63S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts,) complete incl making good to floor to match with adjoining surfaces including plastic water closet seat cover white closed pattern with flat bottom mild steel chromium plated of aluminium hinging device etc completeall as directed by Engr-in-Charge
64S&F for 15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs etc complete all as specified. Including taking up or down steel tubing and connections upto 15mm bore.
65S&F for 20 mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs etc complete all as specified. Including taking up or down steel tubing and connections upto 20 mm bore.
66M & L for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including taking down old unserviceble PVC water tank all as specified in SSR Part-I completedand asdirected by the Engr-in-Charge
67M & L for 1000 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including taking down old unserviceble PVC water tank all as specified in SSR Part-I completedand asdirected by the Engr-in-Charge
68S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to laid in trenches or in floors/wall complete all as specified and as directed by the Engineer-in-Charge
69S & F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/wallcomplete all as specified and as directed by the Engineer-in-Charge
70S&F PVC(SWR) bend 110mm dia bore complete all as specified and directed by Engr-in-Charge
71S&F PVC(SWR) bend 75 mm dia bore complete all as specified and directed by Engr-in-Charge
72S & F in repair 100 mm dia CP grating plain including jointing with solvent cement.
73S&F in repair 75 mm dia PVC(SWR) floor trap, with grating including jointing with solvent cement etc complete all as specified.
74S&F in repair chromium plated health faucets (hand held shower type) with shut off valve (thumb or push button type) to allow controlled and continuous flow of water with adequate length and wall mounted pedestal for hanging the faucet etc complete.
75S&F in repairs sinks with drainage board made of stainless steel1 mm thick kitchen or laboratorywith plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm etc complete all as specified.
76S&F aluminium anodised 4 pin cloth hook hangerfixed to wall complete all as specified and as directed.
77Dismantling timber scantlings 40 sqcm and under in section, in any position framed / Unframed work complete all as specified by the Engr-in-Charge
78Dismantling wrought iron or mild steel work of any description any position not otherwise provided complete all as specified
79M & L for 6 mmPlywood, grade BWR, type BB, fixed with screws to timber frame work all as specified including dsmantling ofwall andceiling board (fibre, pulp, insulation, etc) or insulationboards etc,, any thickness etc. including cover fillets complete
80M&L for 18/19 mmblock boards,interior grade, fixed with screws to timber frame work complete all as specified. including dsmantling ofwall andceiling board (fibre, pulp, insulation, etc) or insulationboards etc,, any thickness etc. including cover fillets complete
81M&L 6mm thick teak wood lipping for block board or veneered plywood 18/19mm thick, fixed with nails in repairscomplete all as specified and directed.
82Material and Labour for 2nd class hard wood (Hollock) Plain fillets Exc6& n. exc13 sq.cm square, rectangular or triangular in section, clean sawn, secured with nails or brads,complete including dismantling timber scantlings 40 sqcm and under in section, in any position framed / Unframed work complete all as specified by the Engr-in-Chargeall as specified.
83S&F for 0.9 mm thick decorative laminate type 1 of surface finish colour andpattern as approved, fixed with approved adhesive as per specified and as directed
84M& L forPVC edge strip of 18/19 mm wide,colour andpattern as approved fixed withadhesive as per specified and as directed
85S&F in repair Continuous (piano) hinges,mild steel, bright finish or elec trogalvanisedbright finish width of flaps(when open) 30 mm complete all as specified.
86S&F 100 mm long extruded stainless steelhandle fabricated type anodised, complete all as specified.
87S&F Hasp and staple, safety type,of aluminium anodised including bolt to hinge plate and fixed with screws 100 mm size complete all as specified.
88S&Fmagnetic steel stopper catcher holder for cup board of approprite shape and size all as directed.
89Material and Labour Framed work such as grills, gratings,railingetc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165complete all as specified.
90Material and Labour for Welded steel wire fabric n.exc 4 Kg/Sqm suppliedand fixedcomplete to wood or steel members complete all as specified.
91M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified & directed complete all as specified and directed by Engr-in-Charge.
92M&Lfor cement concrete 1:4:8 type D-2( using 40mm graded stone aggregate) as in sub base floor and infoundationincluding necessary form work complete all as specified and directed.including demolition of cement concrete (unreinforced) in ground floors and pavingsnot exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials )
93M&LforPCCType B1 1: 2:4 (20 mm graded stone aggregate ) Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges as in coping ,kneelers , appex stone, copingetc .including demolition of cement concrete (unreinforced) in ground floors and pavingsnot exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials )
94M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement andno pigment set and jointed in neat cement slurry over 20 mm thick cement screed in CM 1:6 all as specified.all as specified and as directed
95M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment set and jointed in neat cement slurry over 20 mm thick cement screed in CM 1:6 all as specified.all as specified and as directed
96M&L for Chequered cement concrete tiles 30 cmx 30cm x 25 mm thick, with grey cement and pigment set jointed and pointed in neat cement slurry over and including 20 mm thick screed bed in CM 1:6in floors with grey cement and pigments complete all as specified and directed
97Taking down carefully any type of battens or conduit point wiringwith or except conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge.
98Material and labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLSH PVC insulated, unsheathed, copper conductor cable in and incl PVC casing -n-caping of any size/dia medium grade complete with all accessories/fittings, brass screws, washer etc and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded FRLSH copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings :-
99One light /Exhaust fan point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed.
100One bell point controlled by one, one way switch 05 / 06 Amps complete all as specified and directed.
101One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed.
102One 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed.
103One two way point controlled by two, two way switches 06 Amps complete all as specified and directed.
104All as per serial item No 97.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06 Amps socket outlet point on independent board complete all as specified and directed.
105All as per serial item No 97.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed.
106Material & labour forpoint wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLSHPVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc,and including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded FRLSH copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings :-
107One light / Exhaust fan point controlled by one, one way switch 06 Amps complete all as specified and directed.
108One bell point controlled by one, one way switch 06 Amps complete all as specified and directed.
109One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and directed.
110One 3 pin,06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and directed.
111One two way point controlled by two, two way switches 06 Amps complete all as specified and directed.
112All as per serial item No 99.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 3 pin 06 Amps socket outlet point on independent board complete all as specified and directed.
113All as per serial item No 99.03 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable forone 3 pin 06/16 Amps socket outlet point on independent board complete all as specified and directed.
114Supply & fixing modular switch 1module, 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
115Supply & fixing socket, 06 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge
116Supply & fixing modular switch 1module,16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
117Supply & fixing socket, 06/16 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge
118Supply and fixing modular bell push 1module, 06 amps , 240 volts all as directed by Engr-in-Charge
119Supply and fixing door bell ding dong type , 240 volts AC
120Supply & fixing modular switch 1module, 06 Amps single pole, two way 240 volts complete all as specified & directed. by Engr-in-Charge
121Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed by Engr-in-Charge
122Supply and fix LED lamp 9/10 watt complete all as specified and directed.
123Supply & fixing in repair LED tube light batten fitting 18/20W, (single Side Connection) including LED Rod including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
124Supply & fixing/fixing in repair LED mirror light 10W including rod complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
125Supply and fixing in repair of 9/10 W LED bulk head luminairies incl LED light with clear prismatic diffuser,driver holder connecting up with three core flexible copper conductor cable of suitable sizeincluding all acessories for fixing on wall all as specified and directed by Engr-in-Charge.
126Supply and fixing wall mounted decorative fancy light fitting stylo (Round)suitable for 14 watts LED lamp including provisson of fixing on wall with all items required for fixing all as specified and directed by Engr-in-Charge.
127Supply & fixing of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed by Engineer -in- Charge.
128Taking down carefully unserviceable Sub main wiring of any size and type, removing material from site for taking credit and making good the disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed by Engineer - in - Charge.
129Material and labour for sub main wiring with 2x4 Sqmm nominal cross sectional area (two single core cable of 4 Sqmm for Phase and neutral + o1 single core cable of 2.5 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dully including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.
130Ditto all as item No 116.00 above, but by using two single core cable of 6 Sqmm for Phase and neutral + 1 single core cable of 4 Sqmm for earth wire.
131Taking down carefully unserviceable distribution board of any capacity including wooden board and making good the disturbed surfaces of walls, etc including two coats of white / colour washing / distempering etc to match the existing complete all as directed by Engineer - in - Charge.
132Supply and fixing sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge.
133All as per item No 119.00, herein before but of size 08 way SPN.
134All as per item No 119.00, herein before but of size 12 way SPN.
135Supply and fixing MCB, SP, AC, 240 volts "C" series capacity of 06 to 32 Amps, 10kA and making connections with suitable thimble complete all as specified & directed.
136Supply & fixing MCB, DP (Double Pole), AC, 240 volts, C series capacity 20 Amps to 32 Amps10kA and making connections with suitable thimble complete all as specified & directed.
137Supply & fixing MCB, DP (Double Pole), AC, 240 volts, C series capacity 40 Amps to 63 Amps10kA and making connections with suitable thimble complete all as specified & directed.
138Supply and fixing sheet metal enclosure, Triple pole and neutral AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection including provision of four pole 100 Amp isolator and MCBs of cap 20 to 40 Amps as incomer with metal double door and flush to wall including all cutting etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge.
139Supply & fix Isolator 4 Pole "C" series 100 amps capacity AC 415 V,10kA complete all as specified and directed.
140M & l for Sheet metal enclosure fiiting on wall and making the connection with provison of MCCB 4 Pole 100 Amps 25 KA, 415 volts , 50 Hz ,thimble/lugs, aslo including all nuts bolts required for fixing all as specified and directed by Engineer - in - Charge
141Supply & fixing industrial type SPN enclosure with a two pin and earth plug and socket complete with and including 32 Amps MCB, single pole, AC, 240 volts and flush to wall including all cuttings & chases etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge.
142Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete all as specified and directed.
143Taking down carefully under ground cable of any size and making good to disturbed surface as per existing complete all as specified and directed.
144Supply, laying commissioning, testing of XLPE under ground LT cable 1100 volts grade of size 25 Sqmm 3.5 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches, fixing on wall, under road crossing through protection pipe etc complete all as specified and directed.
145-ditto- all as per item No 131.00,but 16 Sqmm 2 core
146-ditto- all as per item No 131.00,but 10 Sqmm 2 core
147Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in hard/dense soil and gating out in hard/dense soil complete all as specified and directed.
148Supply / laying and fixing 50 mm bore HDPE pipe PN10 with all fittings laid in trenches for cable protection complete all as specified and directed.
149Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft / loose soil complete all as specified and directed.
150Removing surplus excavated materials n.exc. 50 Mtr and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete all as specified and directed.
151Taking down the geyser of 25/ 50 ltr capacities from the site after disconnecting the water connection, electric connection, opening the geyser assembly and descalling deposited in the inner container and outlet water pipe set complete all as directed by Engineer-in-Charge. (Note:- Replacement of Unserviceable bolts, rubber real, ring nuts, washers to be included in the rate quoted by tenderer. However supply & fix or material & labour for GI fittings and other connected works shall be measured and paid for separately under respective items of schedule ‘A’ here in after) :-
152Supply & fix in repair of geyser syphon assembly steel plate with nuts and bolts, washers, clamps and rubber ring any Make of geyser, for 25/50 ltr capacity of Geysers.
153Supply & fix in repair of thermostatic switch 11 " long ISI marked complete with electric connection suitable for geyserany Make complete all as specified and directed.
154Supply & fix in repair ofgeyser element 1.5 /2.0 KW capacity with rubber ring Round/trangular type complete with clamps, nuts and bolts washers etc for geysers ISI marked (any Make) completeall as specified and directed.
155Supply and fix Non return valve 15mm dia made of bronze ISI marked heavy duty fixed in repairs complete all as directed by Engineer-in-Charge.
156Supply & fix (in repairs) 15mm dia PVCconnection 450 mm long , suitable for hot water supply ,complete with 2 Nosbrass nuts complete all as specified and directed.
157Supply & fix (in repairs) 15mm dia PVCconnection 450 mm long , suitable for cold water supply ,complete with 2 Nosbrass nuts complete all as specified and directed.
158Supply & fix in repairs of Zebra fastner of size 12x100 mm complete all as specified and directed .
159Taking down of the following accessories in repair works including all necessary fitting items such as screw, nut and bolt, connector, flexible copper wire 1.5/2.5Sqmm size etc including cheking/testing complete as directed by Engr-in-Charge :-
160Supply & fixing modular switch 1module, 06 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
161Supply & fixing socket, 06 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge
162Supply & fixing modular switch 1module,16 Amps single pole, one way 240 volts complete all as specified & directed by Engr-in-Charge
163Supply & fixing socket, 06/16 Amps 2/3 pin combined, 2module, 240 volts complete all as specified & directed by Engr-in-Charge
164Supply and fix in repair lamp holder (Angular / Straight), insulated body, with back plate for batten fitting all as specified and directed by Engr-in-Charge
165Supply and fix in repairwhite cover plate with frame 1 module complete all as specified & directed by Engr-in-Charge
166Supply and fix in repairwhite cover plate with frame 2 module complete all as specified & directed by Engr-in-Charge
167Supply and fix in repairwhite cover plate with frame 3 module complete all as specified & directed by Engr-in-Charge
168Supply and fix in repairwhite cover plate with frame 4 module complete all as specified & directed by Engr-in-Charge
169Supply and fix in repairwhite cover plate with frame 6 module complete all as specified & directed by Engr-in-Charge
170Supply and fix in repairwhite cover plate with frame 8 module complete all as specified & directed by Engr-in-Charge
171Supply and fix in repairmetal flush box 1/2 module complete all as specified & directed by Engr-in-Charge
172Supply and fix in repairmetal flush box2 module complete all as specified & directed by Engr-in-Charge
173Supply and fix in repair metal flush box3 module complete all as specified & directed by Engr-in-Charge
174Supply and fix in repairmetal flush box4 module complete all as specified & directed by Engr-in-Charge
175Supply and fix in repair metal flush box6 module complete all as specified & directed by Engr-in-Charge
176Supply and fix in repair modular switch socket combination16 A, 6 pin, 3 module complete all as specified & directed by Engr-in-Charge
177Supply and fix in repair modular switch socket outlet 03 pin 06 A, flush type complete all as specified & directed by Engr-in-Charge
178Supply and fix in repair modular switch socket outlet 03 pin 16 A, flush type complete all as specified & directed by Engr-in-Charge
179S&F in Replacement Exhaust Fan 250mm plastic body , 1400 RPM with air delivery 1050 CMH including and taking down unserviceable, complete all as specified and directed
180S&F in Replacement Exhaust Fan 300mm Sweep metal body (Heavy Duty), 1400 RPM with air delivery 1050 CMH including and taking down unserviceable, complete all as specified and directed.
181M&L for electric insulation tape heavy duty complete all as per specifed and directed.
182S&F self ballasted LED Retrofit Bulb 5 Star Bulbs 12 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
183Supplying and fixing Meter Box made up of BWR plywood board of 8mm thickness covered with 3mm thick laminated sheet, size of the box shall be of 900mm x 450mm x 250mm including provision of shutters with lock and clasp complete and fixed as directed by Engr-in-Charge.
184Amount of credit of Rs. 31871.10 for retrived old material as mentioned in Schedule "A" section-II of tender document in pdf form, will be deducted offline while acceptence of tender.