Tender For Periodical Services In Various Bldgs At Basra Area And Living In Area, Reapir / Maint Of Chajjas, Rcc Tanks, Plinth Protection, Tank Cleaning And Allied Works In Basra Area, Repair / Maint Of Joinery And Allied Works At Basra Area And Living, hasimara-West Bengal

Military Engineer Services-MES has published Tender For Periodical Services In Various Bldgs At Basra Area And Living In Area, Reapir / Maint Of Chajjas, Rcc Tanks, Plinth Protection, Tank Cleaning And Allied Works In Basra Area, Repair / Maint Of Joinery And Allied Works At Basra Area And Living. Submission Date for this Tender is 29-04-2023. Electrical Panel Tenders in hasimara West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

37173153
Corrigendum : Tender For Periodical Services In Various Bldgs At Basra Area And Living In Area, Reapir / Maint Of Chajjas, Rcc Tanks, Plinth Protection, Tank Cleaning And Allied Works In Basra Area, Repair / Maint Of Joinery And Allied Works At Basra Area And Living
Open Tender
Indian
West Bengal
hasimara
29-04-2023

Tender Details

Tender For Periodical Services In Various Bldgs At Basra Area And Living In Area, Reapir / Maint Of Chajjas, Rcc Tanks, Plinth Protection, Tank Cleaning And Allied Works In Basra Area, Repair / Maint Of Joinery And Allied Works At Basra Area And Living In Area, Repair / Maint Of Roof, Including Roof Treatment And Allied Items At Wsa And Repair / Maint Incl Replacement Of Lt Panels And Other Works At Mes / Basra Area At Afs Hasimara

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Apr-2023 CORRIGENDUM TO TENDER Other 29-04-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
Refer document

BOQ Items

Nature of Work :PERIODICAL SERIVICES IN VARIOUS BLDGS AT BASRA AREA AND LIVING IN AREA,REAPIR/MAINT OF CHAJJAS, RCC TANKS, PLINTH PROTECTION,TANKCLEANINGANDALLIED WORKS IN BASRA AREA, REPAIR/MAINT OF JOINERY AND ALLIED WORKS AT BASRA AREA AND LIVING IN AREA, REPAIR/MAINT OF ROOF, INCLUDING ROOF TREATMENT AND ALLIED ITEMS AT WSA AND REPAIR/MAINT INCL REPLACEMENT OF LT PANELS AND OTHER WORKS AT MES/BASRA AREA AT AFS HASIMARA
Sl. No. Item Description
1Preparation of surfaces incl brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts over all decorated plastered or un plastered surfaces of walls including cornices etc and applying one coat of white wash, complete all as specified and directed.
2All as per item No. 01 here in above but applying two coats of white washing, complete all as specified and directed.
3All as per item No. 01 here in above but applying one coat of white washing on ceiling, complete all as specified and directed.
4All as per item No. 01 here in above but applying two coats of white washing on ceiling, complete all as specified and directed.
5All as per srl item No. 01 here in above but applying one coat of oil bound distemper on wall, complete all as specified and as directed.
6All as per srl item No. 01 here in above but applying two coats of oil bound distemper on wall, complete all as specified and as directed.
7All as per item No. 1 here in above but applying one coat of exterior emulsion paint on old decorated plaster surfaces of walls/chajjas/band/facia/balcony etc, complete all as specified and as directed.
8Preparing of previously painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint (1st grade quality), complete all as specified and directed.
9Preparing of previously painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint (1st grade quality), complete all as specified and as directed.
10Writing letters or figures (block, roman, italic or Indian) exc. 15cm and n. exc. 30cm high, complete all as specified and as directed.
11Taking down cement plaster on brick/concrete surfaces of any description in any position incl racking out joints, hacking for key, scrubbing down with water etc and removing rubish off the premises, complete all as specified and directed.
12M & L for rendering 10mm thick plaster in CM (1:4) on fair faces of brick work or concrete, surface finished even and smooth without using extra cement, complete all as specified and directed.
13M&L for applying two coats of oil bound distemper over a coat of 1mmthick wall care putty on wall surfaces including preparation of new surfaces of walls, complete all as specified and directed.
14Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.
15Use & Waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings, chajja and similar work; not exceeding 200mm thick (horizonal or sloping) for flat, rough finished surfaces of concrete, complete all as specified and directed.
16M&L reinforced cement concrete M-25 grade (1:5:3) type A-1 (using 20mm graded crushed stone aggregate) (nominal mix) as in chajjas etc, complete all as specified and directed.
17M&L TMT bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, quality conforming to GD-I. IS-432 (Part I), complete all as specified and directed.
18S & F 110mm bore, PVC (SWR), soil waste and vent pipes in any length with or without ears, with cement joints fixed to floor walls, etc with all necessary fixing arrangement including taking down old U/S pipes of any description, complete all as specified and directed.
19S & F 75mm bore, PVC (SWR), soil waste and vent pipes in any length with or without ears, with cement joints fixed to floor walls, etc with all necessary fixing arrangement including taking down old U/S pipes of any description, complete all as specified and directed.
20S & F 110mm bore PVC (SWR) bends of any radius,complete all as specified and directed.
21S & F 75mm bore PVC (SWR) bends of any radius, complete all as specified and directed.
22Supply and fix for 75mm bore PVC (SWR) branch pieces, single (single Y) equal or unequal, complete all as specified and directed.
23Supply and fix for 110mm bore PVC (SWR) branch pieces, single (single Y) equal or unequal, complete all as specified and directed.
24S&F in repair curtain rod 25mm dia anodised aluminum with fixing brackets, stos, rollers etc., complete all as specified and directed. Make : Vista/lever
25Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level), complete all as specified and directed.
26M & L for 75mm thick plain cement concrete(1:3:6), type C-1 (using 20mm graded crushed stone aggregate) as in plinth protectionor hard standing etc, finishing cement concrete surface even and smooth with out using extra cement, complete all as specified and directed.
27Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed.
28M&L chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement &pigments laid over and including screed bed or bedding layer of 15mm thick in CM(1:6) and surfcae prepared to receive flooring tiles, complete all as specified and directed.
29Disconnecting existing tanks (exc. 500 & not exc 1000 ltr), setting aside (or lowering if required) for repairs, cleaning, etc. and hoistingif required reconnecting and refixing in position, complete all as specified and directed.
30Taking down of chowkats or frames n. exc. 1.5 Sqm each with shutters (without taking off shutters from the frames), complete all as specified and directed.
31Taking down of chowkats or frames exc. 1.5 Sqm eachwith shutters but n. exc. 4 Sqm each with shutters (without taking off shutters from the frames), complete all as specified and directed.
32Taking down shutter of any description exc 1 Sqm but not exc. 2 Sqm each, complete all as specified and directed.
33Taking down & refixing in the same opening shutter of any description exc 1 Sqm but not exc. 2 Sqm each, complete all as specified and directed.
34S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. including powder coating(minimum thickness of powder coating 50 micron), complete all as specified and directed.
35S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. powder coating of any colour (thickness or powder coating not less than 50 micron), complete all as specified and directed.
36S&F anodised aluminium partitions, aluminium section including necessary joining cleats, glazing clips, rubber neoprene packing, hinges, anodised aluminum snap beading, screws etc. powder coating of any colour (thickness or powder coating not less than 50 micron), complete all as specified and directed.
37Supply and fixing for glazed powder coated coloured (minimum 50 micron) aluminium windows with frame comprising of 3 track sliding window made out of aluminium extruded section of bottom frame of weight not less than 1.175 Kg/Rm, top and side frame of weighing not less than 1.174 Kg/Rm, the vertical styles of shutters of weighing not less than 0.423 Kg/Rm, top and bottom rail of shutters of weiighing not less than 0.368 Kg/Rm, in two pannels and shutter with and including 5mm thick selected quality tinted glass & third one with and incl stainless steel wiremesh and overall aluminium decogrill . as approved by GE, fixed with standard aluminium channel out side, with and including handles, cleat, glazing clip, special auto lock, dry set rubber gasket, complete all as specified and directed.
38M&L for box type steel window side with hung double shutters with provision for desert cooler/AC (inside for wire mesh & out síde for glass), includíng guard bar,hinges, steel handle, tower bolt and steel peg stay, complete with glazing bar dovetailed or welded including a coat of red oxide primer after preparation of surfaces, and fixed, steel window shall be conforming to relevant IS, complete all as specified and directed. Note:-Wire mesh and sheet glass shall be measured and paid separately
39M &L for box type steel ventilators top hung double shutters (inside for wire mesh & out side for glass), including hínges, steel handle, tower bolt and steel peg stay, complete with glazing bar dovetailed or welded including a coat of red oxide primer after preparation of surface before fixing, steel ventilator shall be conforming to relevant IS, complete all as specified and directed. Note:- Wire mesh and sheet glass shall be measured and paid separately
40M&L for preparing new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality), complete all as specified and directed.
41S&F in repairs 12mm thick prelaminated particle board,exterior grade prelaminated one sides with decorative choice lamination and on other side balancing white lamination, fixed with screws to timber frame work/mild steel framing, complete all as specified and directed.
42S&F pressed steel frames for doors factory madethickness of frame 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, lock strike plate, hinges etc complete, size of frame 125x60mm, complete all as specified and directed.
43S&F pressed steel frames for doors factory made thickness of frame 1.25mm thick PBI sheet with one of more rebates including necessary flat iron lugs, lock strike plate, hinges etc complete, size of frame 105x60mm, complete all as specified and directed.
44S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet rreinforced with MS square tube supplying & fixing in opening, complete all as specified and directed.
45S&F factory made panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes and bottom rails, MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width struct inside with solvent cement for styles and plaincolour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail.panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rail with suitable PVC sheet beading and jointed together with solvent cement at site, complete all as specified and directed.
46Supply and fix MS holdfast made up of FI 25 x 3mm conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed.
47Supply and fix 35mm thick (factory made), 2nd class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats, complete all as specified and directed.
48Supply and fix 35mmthick factory made glazed and skelton shutters of 2nd class hardwood open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain chamfered or rounded fitted with cutand mitered beads for securing glass/guage etc, complete all as specified and directed.
49Supply and fix 100mm size mild steel butt hinges medium weight cold rolled, complete all as specified and directed.
50Supply and fix for 150mm long aluminium anodized barrel tower bolts of extruded section, complete all as specified and directed.
51Supply and fix for 75mm longbutt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised type C-21, complete all as specified and directed.
52Supply and fix for 150mm long aluminium handles, cast type, anodised, complete all as specified and directed.
53S&F in repairs, mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate of length of bolt of 250mm, complete all as specified and directed.
54S&F aluminium alloy, anodised,sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy, complete all as specified and directed.
55Preparing of wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over one coat of pink primer, complete all as specified and directed.
56S&F aluminium mortice lock, vertical type, size 100mm (2 levers), complete all as specified and directed.
57S&F aluminium mortice lock, vertical type, size 75mm (2 levers), complete all as specified and directed.
58S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm as in doors or windows with necessary nails andfillets), complete all as specified and directed.
59M&L for plain cement concrete (1:2:4) type B-1(using 20mm graded crushed stone aggregate) as in hold fast block incl necessary form work complete), complete all as specified and directed.
60Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
61M&L for hacking out old broken glass (any thickness,size,quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed.
62S & F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane, complete all as specified and directed.
63S & F 4mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 Sqm each pane, complete all as specified and directed.
64S&F in repair door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutter of 851 to 1000mm in width & of weight between 61 to 81 kg, complete all as specified and directed.
65S&F in repair 5.5mm thick selected quality tinted sheet glass and glazing in square fixed with PVC/neoprene gasket in aluminium frame work, complete all as specified and directed.
66Dismantling of asbestos cement (corrugated, semi corrugated sheets etc.)of any thickness includingridges, hips, valleys as in roof covering, complete all as specified and directed.
67S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thickhaving tensile strength of 550 Mpa as in roof covering/clading to wall/eaves board, fixed with self taping screws, complete all as specified and directed.
68S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thickhaving tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self taping screws, complete all as specified and directed.
69M & L for PCC (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) as in padding, finished even and smooth without using extra cement, complete all as specified and directed.
70M & L Water proofing treatment on RCC roof etc. comprising of the following operations and as specified herein below,,complete all as specified and directed:- (a)Taking down existing old tarfelt, bituminous compound, old plaster including cleaning, picking, sweeping and washing down with water and brushing with neat cement slurry @ 3 Kg per Sqm & removing debris to a distance exc 100m & n.exc. 250m. (b)15mm thick plastering in cement mortar (1:3) mixed with liquid water proofing compound (WPC to be measured seperately) as per manufacturer instructions finished even & smooth. (c)Preparing & cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 300 ml per sqm conforming IS-3384 (e) A layer of APP based polymeric membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric(weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above.Application of polymeric membrane shall be by torch application. The over lap shall be done minimum 100mm on transverse direction and 75mm in longitudinal direction. (f) Applying one coat of aluminium paint over the APP based membrane @ 0.11 lit/Sqm.
71Supply only integral liquid water proofing compound of approved quality, complete all as specified and directed. (Make- CICO NO.1/SIKA/ACCO PROOF/DR. FIXIT)
72Taking down existing unserviceable outdoor/indoor LT panel/APFC panel board complete with existing accessories, complete all as specified and directed.
73Taking out and relaying of UG cables of any cross sectional area and connections including bricks, GI pipes, etc of any description, laid in trenches and/or fixed with walls/poles including segregating of serviceable materials viz bricks, cables, GI pipes etc for re-laying after fixing of LT panel board, complete all as specified and directed. (Excavation and earthwork shall be measured and paid seperately).
74Supply, fabricating, installing, testing and commissioning of indoor type LT feeder pillar box of suitable size factory fabricated, floor mounted double door, dust and vermin proof CPRI approved made out of 2.0 mm thick CRCA sheet mounting on 50x50x5mm angle iron supports at the base duly painted with synthetic enamel paint and panel board with front and back opening and locking arrangement complete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus bar strip 2 x (40mm x 10mm) for threephase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessories at Main power House 550 KVA DG Set panel :- (i)MCCB 630 Amps AC 4 pole 415 Volt 50 KA breaking capacitywith thermal magnetic release range 500-630 Amp- 01 Nos with suitable rotary extendable handle for operation of MCCB of Make : L & T Cat part No CM94104OOT1OG or equivalent in Schneider / Legrand/ ABB (ii) Panel mounted manual change over switch 630 Amp open execution type including source seperator / phase barrier, extended rotary handle (Heavy duty) and connection with suitale size strip complete all as specified and directed of Make :L & T cat part No CO46300OOOO or equivalent in ABB/ Schneider. (iii) Panel mounted mannual change over switch 400 Amp open execution type including source seperator/phase barrier, extended rotary handle (Heavy duty) and connection with suitale size strip complete all as specified and directed of Make :L & T cat part No CO44000OOOO or equivalent in ABB/ Schneider. - 02 Nos (For AF Domestic Panel & MES Domestic Panel) (iv)MCCB 400 Amps Nos, AC 4 pole 415 Volt 36 KA breaking Capacitywith thermal magnetic release range 400-500 Amp- 02 Noswith suitable rotary extendable handle for operation of MCCB of Make : L & T cat part No CM94106OOS1OG or equivalent in Schneider /Legrand / ABB (v)MCCB 125 Amps, AC 4 pole 415 Volt 36 KA Breaking Capacitywith thermal magnetic release range 125-160 Amp- 02 Noswith suitable rotary extendable handle for operation of MCCBof Make : L & T cat part No CM92108OOM1OG or equivalent in Schneider /Legrand / ABB(vi) Digital voltmeterwith selector switch with suitable CT"s for incoming of Make : L & T cat part No WL132010OOOO or equivalent in AE /Schneider/ ABB (vii) Digital ammeter with selector switch alognwith suitable CT"s for incoming Make : L & T cat part No WL131010OOOO or equivalent in AE/Schneider/ ABB (viii) Phase indicating lamp LED Type (R-Y-B) for incomingand each outgoing connections of Make : AE, L&T, Schneider (ix) Both side of LT panel cable alley shall be provided of width not less than 450 mm for top/bottom entry of cable alongwith arrangement of cable hanging and outgoing connection terminal in alley for all outgoing / incoming connection.
75Supply, fabricating, installing, testing and commissioning of indoor type LT feeder pillar box of suitable size factory fabricated, floor mounted double door, dust and vermin proof CPRI approved made out of 2.0 mm thick CRCA sheet mounting on 50x50x5mm angle iron supports at the base duly painted with synthetic enamel paint and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus Bar strip 40mm x 10mm for threephase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessories at main power house (Air Force domestic panel) (a) INCOMING:-MCCB 400 Amps, AC 4 pole 415 Volt 36 KA breaking capacity with thermal magnetic release range 400-500 Amp- 01 Noswith suitable rotary extendable handle for operation of MCCB of Make : L & T cat part No CM94106OOS1OG or equivalent in Schneider /Legrand / ABB (b) OUTGOING :-(i)MCCB 250 Amps, AC 4 pole 415 Volt 36 KA breaking capacitywith thermal magnetic release range 250-320 Amp- 02 Noswith suitable rotary extendable handle for operation of MCCB of Make : L & T cat part No CM98403OOQOOG or equivalent in Schneider /Legrand / ABB(ii)MCCB 125 Amps, AC 4 pole 415 Volt 36 KA breaking capacitywith thermal magnetic release range 125-160 Amp- 02 Noswith suitable rotary extendable handle for operation of MCCBof Make : L & T cat part No CM92108OOM1OG or equivalent in Schneider /Legrand / ABB (iii)MCCB 63 Amps, AC 4 pole 415 Volt 25 KA breaking capacity as per s per IS/IEC 60947-2 & IEC 60947-2 with thermal magnetic release range 63-80 Amp- 02 Noswith suitable rotary extendable handle for operation of MCCBof Make : L & T cat part No CM91712OOJOOG or equivalent in Schneider /Legrand / ABB (iv)MCB SPN 63 Amp-08Nos.of Make:L&T CatPart No BB20630B or equivalent in Schneider/Legrand/ABB (v) Both side of LT panel cable alley shall be provided of width not less than 450 mm for top/bottom entry of cable alongwith arrangement of cable hanging and outgoing connection terminal in alley for all outgoing / incoming connection (vi) Digital voltmeter - 01 No. with selector switch with Suitable CT"s for incoming of Make : AE or equivalent in L & T /Schneider/ ABB(vii) Digital ammeter -01 No. selector switch alognwith suitable CT"s for incoming andeach outgoing connection Make : AE or equivalent in /Schneider/ ABB (viii) Phase indicating lamp LED Type (R-Y-B) - 01 No. for incoming and each outgoing connections of Make : AE, L&T, Schneider
76S&F ofMCCB 160 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2 & IEC 60947-2 with thermal magnetic release range 160-200 Ampincluding providing new thimble/lugs of suitable size andtaking down old unserviceable, complete all as specified and directed. Make : L & T Cat part No CM92109OON1OG or equivalent in Schneider / Legrand/ ABB
77Supply and fixing of MCCB 125 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2 & IEC 60947-2 with thermal magnetic release range 125-160 Amp including providing new thimble/lugs of suitable size andtaking down old unserviceable, complete all as specified and directed. Make : L & T Cat part No CM92108OOM1OG or equivalent in Schneider / Legrand/ ABB
78Supply and fixing ofMCCB 100 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2 & IEC 60947-2 with thermal magnetic release range 100-125 Amp including providing new thimble/lugs of suitable size andtaking down old unserviceable, complete all as specified and directed. Make : L & T Cat part No CM92108OOL1OG or equivalent in Schneider / Legrand/ ABB Note :-An amount of Rs.46212.00 on account of credit schedule for schedule "A" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
79Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy