Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #37155522

Annual Rate Contract For The Work Of Construction And Commissioning Of 200 / 150 Mm Dia. Tube Wells With Providing Installation And Commissioning Of Three Phase / Single Phase Power Pump Set Phed Division Kekri, District Ajmer

Issued by Government Departments · kekri, Rajasthan
Tender Value
1 Crore
Estimated cost
Bid Submission
26 Apr 2023
0 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kekri → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Annual Rate Contract For The Work Of Construction And Commissioning Of 200 / 150 Mm Dia. Tube Wells With Providing Installation And Commissioning Of Three Phase / Single Phase Power Pump Set Phed Division Kekri, District Ajmer

BOQ

Name of Work: “Annual Rate Contract for the work of construction and commissioning of 200/150 MM dia Tube wells with Providing installation and commissioning of Three Phase/ Single Phase Power pump set along with related civil and electrical works etc. Under the jurisdiction of PHED Division Kekri, District Ajmer.”, NIT No: 01/2023-24
Sl. No. Item Description
1Constructionoftubewellfromgroundlevel& upto 100mtrdepthto accommodatehousingandassemblypipeoffollowingsizesinalltypeof alluviumstrata unconsolidatedformationsuchaspebbles,bouldersetc.by percussion/rotary drilling method as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and it\"s packing as per IS: 2800 (Part I & II) 1979 as amended uptodate(theworkincludesthecostofgravel&it\"sprimarypackingand packingduringdevelopment,loweringofhousing&strainerassemblypipes withsupplyandwrappingofcoir-rope,wherevernecessaryforarrestingfine sandparticlesanddevelopmentwork,butexcludingthecostofhousingand strainerpipeassembly).Theworkwouldbecompletedafterobtainingsand free water.
2Nominal bore 150 mm dia.
3Nominal bore 200 mm dia.
4Nominal bore 250 mm dia.
5Add 15% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 100 mtr and up to 200 mtr, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
6Add 40% extra on above item (Item no 2.1.1 to 2.1.3) for drilling depth beyond 200 mtr, rate shall be applicable for only extra depth beyond 200 mtr .
7ConstructionofTubeWellfromgroundlevelandupto100mtr.depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drillingmethod asperIS:2800Part1:1991and IS:2800PartII:1979(both amended up todate) andtechnical specificationsfor removalofoverburden. The work includes the cost oflowering of casing pipe, but excludes the cost of casingpipe.
8Nominal bore 200 mm dia.
9Nominal bore 250 mm dia.
10Add 15% extra on above item(Item No 2.2.1 to 2.2.2) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .
11Constructionoftubewellaftercompletionofdrillingbyrotary/percussion method&upto100mtr.depth inalltypeofrocksbyDTHsystem asper IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technicalspecifications.Thework shallbedeemedcompletedonlyafter obtainingsandfreewater.Theborewellshouldhaveathroughoutnominalsize bore beyond casing pipe.
12Nominal bore 150 mm dia.
13Nominal bore 200 mm dia.
14Nominal bore 250 mm dia.
15Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
16Add 30% extra on above item(Item No 2.3.1 to 2.3.3) for drilling depth beyond 200mtrandfromgroundlevel,rateshallbeapplicableforonlyextradepth beyond 200 mtr .
17Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling, where strata iscollapsibleandloweringofcasingpipeisrequired.Theworkincludes lowering of casing pipe, but excluding the cost of casing pipe. The rate shall be applicable for stretch of collapsible strata only.
18ConstructionofTubeWellupto100mtr.depth inalltypeofrocksbyDTH system&overburdentoaccommodatecasingpipeoffollowingsizesinall typesofsoils&overburdenincludingloweringofcasingpipes,(ifrequired) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would becompletedafterobtainingsandfreewater.Thetubewellshouldhavea through out bore as per nominal dia of casing pipe.
19Nominal bore 150 mm dia.
20Nominal bore 200 mm dia.
21Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
22Add 30% extra on above item(Item No 2.4.1 to 2.4.2) for drilling depth beyond 200mtrandfromgroundlevel,rateshallbeapplicableforonlyextradepth beyond 200 mtr .
23Add 15% extra on above item (Item No 2.4.1 to 2.4.4) for drilling, where strata iscollapsibleandloweringofcasingpipeisrequired.Theworkincludes lowering of casing pipe, but excluding the cost of casing pipe. The rate shall beapplicable for stretch of collapsible strata only.
24Constructionoftubewellfromgroundlevelandupto100mtr.depthand above of following sizes in all types of soils in alluvium strata, unconsolidated formationsuchaspebbles,bouldersetc.by\"bailing\"methodandwithout gravelpackingasperIS:2800Part1:1991and IS:2800PartII:1979(both amended up to date) and technical specifications. The work includes formation of cavity at bottom by development with appropriate air compressor or bailer pumping and also lowering of casing pipe but excluding cost of the casing pipe. The tube well should have a throughout bore as per nominal dia of casing pipe. The work would be completed after obtaining sand free water.
25Nominal bore 125 mm dia.
26Nominal bore 150 mm dia.
27Nominal bore 200 mm dia.
28Constructionoftubewellfromgroundlevelandupto100mtrdepthand abovetoaccommodatehousingassemblypipeinalltypeofunconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended uptodate)andtechnicalspecifications.Theworkwillincludeloweringof housing andstrainerpipeassemblyandcasingshoeincludingcostofcasing shoe, but excluding cost of the casing pipe. The work would be completed after obtaining sand free water.
29Nominal bore 125 mm dia.
30Nominal Bore 150 mm dia.
31Nominal bore 200 mm dia.
32Add 15% extra on above item (Item No 2.6.1 to 2.6.3) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .
33Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all type of rocks including flushing of tube well and obtainingsand free water.
34Nominal bore 150 mm dia.
35Nominal bore 200 mm dia.
36Testingverticalityoftubewellbyplumbingsystemandyieldtestanddraw downtestbypumpingsystemasperIS:2800(Part–II)–1979orasperamended up to date.
37Supplying & PackingP-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date.
38Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well.
39Supply of ERWM.S. black casing pipe ISI marked (IS: 4270/2001) or amendedup to dateoffollowing sizes
40150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m)
41200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
42250 mm dia NB (Thickness of pipe 7.1 mm & mass of tube 46.57 Kg/m)
43Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985.
44125 mm dia nominal bore of 4.8 mm thickness
45150 mm dia nominal bore of 4.8 mm thickness
46200 mm dia nominal bore of 5.4mm thickness
47250 mm dia nominal bore of 7.1mm thickness
48Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casingpipeforsubmersiblecableexternalwork40mmdiacompleteinallrespect.
49Supply & Installation of single phase ISI marked submersible motor pump set ofthreestarorbetterratingofBEEandasperIS:8034-2018(pump)andIS 9283-2013 (motor) or as amended up to date ofapproved make of following duty condition with required accessories including making connection suitable fortubewell/DCB.Thejobincludesloweringofmotorpump,installationof complete fitting & accessories, jointing of electrical cables up to switch board, testingofsubmersiblepumpsetandinterconnectionuptowatermains, complete in all respect.
50Up to 2.0 KW
51Above 2.0 KW
52Supply&Installationof3phaseISImarkedsubmersiblemotorpumpsetof three star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283- 2013(motor)orasamendeduptodateofapprovedmakeoffollowing duty conditionwithrequiredaccessoriesincludingmakingconnectionsuitablefor tubewell/DCB.Thejobincludesloweringof motorpump,installationof complete fitting & accessories, jointing of electrical cables up to switch board, testingofsubmersiblepumpsetandinterconnectionuptowatermains, complete in all respect.
53Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
54Up to 5.5 KW (7.5 HP) & head above 120 mtr.
557.5 KW (10 HP) & head up to 120 mtr.
567.5 KW (10 HP) & head above 120 mtr.
579.3 KW (12.5 HP) & head up to 120 mtr.
589.3KW (12.5 HP) & head above 120 mtr.
5911 KW (15 HP) & head up to 120 mtr.
6011 KW (15 HP) & head above 120 mtr.
6113 KW (17.5 HP) & head up to 120 mtr.
6213 KW (17.5 HP) & head above 120 mtr.
6315 KW (20 HP) and above, head up to 120 mtr.
6415 KW (20 HP) and above, head above 120 mtr.
65Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approvedmakeandthepanelenclosureshouldbemadeoutfrom18gaugeM.S.Sheetwithpowdercoating.PanelsizeHeight600mmWidth500mm depth250mmwithStand(madeofangleironofsize35x35x5mm)duly bolted/screwedwithenclosureboxhaving4legs,eachleg’slength18\"and double door including in built locking system.The legs should be embedded in M-15cementconcreteplatform.ThesizeofCCplatformshouldbeequalor biggerthanthebasesizeofpanelhavingheightofatleast200mmfrom groundlevel.Theoperationofpanelshouldbesuitableforon240VoltAC Supply.
66Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. completesuitable forthree phase pumpset.Thepanel shouldhavespaceforenergy meter( suppliedby DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600x300mmwithStand(madeofangleironofsize35x35x5mm)duly bolted/screwedwithenclosureboxhaving4legs,eachleg’slength18\"and double door including in built locking system.The legs should be embedded in M-15cementconcreteplatform.ThesizeofCCplatformshouldbeequalor biggerthanthebasesizeofpanelhavingheightofatleast200mmfrom ground level.The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation ofpanel should be suitable for on 440 Volt AC Supply.
67Up to 5.00 HP
68Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lightingarrangementetc.completesuitableforthreephasepumpset.The panelshouldhavespaceforenergymeter(suppliedbyDISCOM). Allthese equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel shouldbe of minimumsize900 x600 x450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meterreading.Theoperationofpanelshouldbesuitableforon440VoltAC Supply.
69Above 5 HP and up to 10 HP
70Above 10 HP and up to 15 HP
71Above 15 HP and up to 20 HP
72Above 20 HP and up to 30 HP
73Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
743 core 4.0 Sq.mm
753 core 6.0 Sq.mm
763 core 10.0 Sq.mm
773 core 16.0 Sq.mm
78Supply&FixingXLPEinsulated/P.V.C.sheathedcableof1.1KVgradewith aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground asperIS:1255includingexcavationof30cmx75cmsizetrench,25cmthick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
7910.0 Sq.mm, 4 core
8016.0 Sq.mm, 4 core
8125.0 Sq.mm, 3.5 core
8235.0 Sq.mm, 3.5 core
83Plate Earthingas per IS:3043 with G.I. Earth plate ofsize 600mmx 600mmx 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete withalternatelayersofsaltandcoke/charcoal,testingofearthresistanceas required.
84Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.
85Supply & Fixingtube well coverofMS sheet 8mmthick attop &5mmthick 100mmwideshroudaroundtheedgesoastoformacaponthe topend of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre ofMS sheet. A25 mmsocket with end plug shall also be welded over top plate. A GI nipple having outside thread ofsize 1/2\" (for installation pressure gauge) shall be provided &welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
86125 mm dia
87150 mm dia
88200 mm dia
89250 mm dia
90Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\" class), SteeltubeasperIS:1239oramendeduptodateandzinccoatingasperIS 4736,threadedanddoubleflanged(welded)onbothendsandtwonumber 25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect.
9132 mm dia
9250 mm dia
9365 mm dia
9480mm dia
95Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GIfittings andPVC ropeconfirming toIS 5175:1992or amendedup to date, along with clamping of submersible cable etc. complete in all respect.
9640 mm dia
9750 mm dia
9863 mm dia
9975 mm dia
10090 mm dia
101Providing,installing,testingandcommissioningofdoubleflangedbulkflow meterwithremovablemechanism,ofclassBconformingtoISO4064/1or amendeduptodateofapprovedmakeincludingcostofallmaterialand labouras per specifications with GI Box (sheet 16 SWG) suitable with lockingarrangement of following dia.
10250 mm dia
10365 mm dia
10480 mm dia
105Providing&FixingpumpsafetycageasperspecificationsorasdirectedbyEngineer in charge.
106Providingand FixingofISImarked PVCstorage tankoffollowingcapacityas per IS: 12701-1989 (ofapproved make) with cover, 25 mm dia. 1 mtr long GI overflowpipe,25cmlong25mmdiawashoutGIpipewithplug&socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVCballcompletewithbrassweight1000gm,includingP&F15mmdiaCI quarter turn heavy duty Bib Cocks four no\"s ofsuperior quality and approvedmake, including interconnections complete job.
1071000 litres capacity
1082000 litres capacity
109Fabrication & Fixing M.S.Stand of specified class of angle iron L-shaped of 50 mmsizewithfourlegsgroutedby300*300*300mmCCBlockM-15inthe groundandalllegstiedupwitheachotherthroughsamesizeofangleiron along with cross bars to support the bottomof1000 Ltr./ 2000 Ltr.PVC tankcomplete in all respect.
110Providing&Fixingofdoubleflanged,CIbody,ISImarkedNRVofapprovedmake of following sizes
11165 mm dia
11280 mm dia
113ProvingandFixing32mmdiaFullwayvalveorwheelvalveas perIS:778 or amended up to date of approved make, on pump delivery pipe.
114Supplying&Installing100mmdiametersealeddiaphragmbourdontype pressuregaugeofrange0to10kg. includingalljointingmaterialasperspecification with safety cover.
115Constructionofboreholeforshallowdepthtubewellfromgroundlevelto required depth for following size for all type of relevant strata by percussion/ rotarydrilling/handboringmethodexcludingcostofcasingpipe.The bore holeshouldbeaspernominalboreofPVCcasingpipe.Theworkwillbecomplete after obtaining sand free water.
116125 mm dia nominal bore
117150 mm dia nominal bore
118200 mm dia nominal bore
119250 mm dia nominal bore
120ProvidingandLoweringofISImarkPVC-UcasingandscreenpipeasperIS: 12818:2010oramendeduptodatehavingpipethicknessasperIScode suitableforTWandDCBwiththreading,windingwithsuperiorqualityof plasticmesh&ropeinthreelayerswithendcapcompleteaspertechnical specification and direction of Engineer In charge.
121Shallow well casing pipe (CS) suitable for depth up to 80 mtr.
122150 mm nominal dia ( internal dia ).
123200 mm nominal dia ( internal dia ).
124250 mm nominal dia ( internal dia ).
125Medium well casing pipe (CM) suitable for depth above 80 mtr and up to 250mtr.
126100 mm nominal dia ( internal dia )
127125 mm nominal dia ( internal dia )
128150 mm nominal dia ( internal dia )
129200 mm nominal dia ( internal dia )
130250 mm nominal dia ( internal dia )
131Supply of ISI mark AC pressure pipe class 15 manufactured by MAZZA process asperIS:1592-2003oramendeduptodate,forcasingoftubewell for following dia nominal bore, with jointing material PVC coupler as per technicalspecification and direction of Engineer In charge.
132125 mm nominal dia
133150 mm nominal dia
134200 mm nominal dia
135250 mm nominal dia
136300 mm nominal dia
137Making slots of hole size and Nos. as directed by EIC in AC pressure pipe Class 15 as per technical specification for using slotted pipe in TW casing.

AI Tender Summary

OUR REF NO 37155522
AUTHORITY Government Departments
TENDER VALUE 1 Crore
LAST DATE 26-04-2023
Authority
Authority Name Public Health Engineering Department
Work Description Annual Rate Contract For The Work Of Construction And Commissioning Of 200 / 150 Mm Dia. Tube Wells With Providing Installation And Commissioning Of Three Phase / Single Phase Power Pump Set Phed Division Kekri, District Ajmer
Basic Detail
Tender No SE_Circle_Ajmer_NIT_1_and_2
Bidding Type Tender
Location
City kekri
State Rajasthan
Key Dates
Publish Date 06 Apr 2023
Submission Date 26 Apr 2023
Open Date 27 Apr 2023
Finance
Tender Value 1 Crore
Tender Fee 1000
EMD 2 Lakhs
Exemption Not Available
Document List
TD_1.pdf
Tendernotice_1.pdf
ee09f8fd-0569-4b8a-92d4-43e0a3e13ac5.html
BOQ_582989.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 06, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 26, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 27, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

TD_1.pdf

pdf

Tendernotice_1.pdf

html

ee09f8fd-0569-4b8a-92d4-43e0a3e13ac5.html

xls

BOQ_582989.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender