Tender For Providing And Installation Of High Lift And Low Lift Pumping Machineries And Other Electromechanical Accessories For Augmentation Work For Barjora Water Supply Scheme (Left Out Mouzas Of Barjora Block Under Brgf Phase I)( Zone Ia) Under, bankura-West Bengal

Public Health Engineering Department-PHED has published Tender For Providing And Installation Of High Lift And Low Lift Pumping Machineries And Other Electromechanical Accessories For Augmentation Work For Barjora Water Supply Scheme (Left Out Mouzas Of Barjora Block Under Brgf Phase I)( Zone Ia) Under. Submission Date for this Tender is 28-04-2023. Pumping Machiney Tenders in bankura West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

37149196
Tender For Providing And Installation Of High Lift And Low Lift Pumping Machineries And Other Electromechanical Accessories For Augmentation Work For Barjora Water Supply Scheme (Left Out Mouzas Of Barjora Block Under Brgf Phase I)( Zone Ia) Under
Open Tender
Indian
West Bengal
bankura
28-04-2023

Tender Details

Providing And Installation Of High Lift And Low Lift Pumping Machineries And Other Electromechanical Accessories For Augmentation Work For Barjora Water Supply Scheme (Left Out Mouzas Of Barjora Block Under Brgf Phase I)( Zone Ia) Under Bmd, Phed

Key Value

Document Fees
Refer document
EMD
INR 203500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Providing and installation of High lift & Low Lift pumping machineries and other electromechanical accessories for Augmentation work for Barjora water supply scheme (Left out mouzas of Barjora Block under BRGF Phase-I)( Zone-IA) under Bankura Mechanical Division, P
Sl. No. Item Description
1PART-A
2Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water and BEE3 star(Minimum) rated capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category Bmotor) as per NIT
3a) Discharge-17 M3/Hour, Total head -52 Mtr
4Supply, delivery and storage at site 80 mm dia UPVC Column pipe medium gauge both side 8 TPI threaded and one side heavy type socket other site rubber cap for threaded protector Standard (17kg/cm2).
5a) 1.5 Mtr. Long
6b) 3.05 Mtr. Long
7Supply and delivery at site 80 mm dia CI Top Adaptor with flange (Single clamp)
8Supply and delivery at site 80 mm dia CI Bottom Adaptor(Single clamp)
9Split type MS fabricated suitable tubewell cover as per tubewell housing with a necessary arrangement for clamping devices including holes for air pipe and cable entry gland
10Safety device for the above pump set by supplying MS cage with proper clamping arrangement andRound Twisted Machine Made Nylon rope 20 mm dia (super quality)as per requirement including supply of all required materials with nuts and bolts as required
11102mm ? 0-12 Kg / cm2 pressure gauge with brass three way cock and syphone and other necessary fittings
12Supply & delivery of M.S. suspension clamp with necessary nuts, bolts & washer etc suitable for 80mm dia pipe (Size-300 mm x 80 mm x 8 mm each)
13Supply and delivery of 80mm diafollowing GI specials for delivery line
14Tee
15Pipe (TATA Medium) (including Socket)
16Bend (90")
17Flange (G.I Threaded)heavy type
18Plug
19Socket
20Supply and delivery of 32mm diafollowing GI specials for Cable Protection
21100mm long short piece
22Bend (90")
23Union
24Pipe (TATA Medium) (including Socket)
25Supply, Delivery and storage at site of Horizantal Split cashing CentrifugalPumping Machinarywith base plate flexible coupllng, coupling guard, foundation bolt etc. other Accessories etc. having the following specification and as per technical Specifications given in NIT N.B- H-Q curve has to be submitted during the delivery (1W+1S)
26a) Discharge : 64M3/Hr, Total Head : 44 mtrs.
27ii) Supply, Delivery and Storage at site of suitable capacity Horizontal Foot Mounted solid shaft Induction Motor (IE 4 type) suitable for the pump duty mentioned above with adequate margin as per detail technical specification given in NIT. N.B-No load as well as short-circuit Test Certificate of induction motor during test run has to be submitted during the delivery.
28Supply & delivery at site following Valves
29Supply & delivery at site & storage CIDF single door swing checkNRV (P.N.–1.0) rating asper IS:5312 Part – I, and as per technical Specifications given in NIT (for individual L/L Pump)
30i) DN 80 mm(for Submersible delivery header)
31ii) DN 100 mm(for H/L individiual delivery header)
32CIDFnon-rising Sluice Valve (P.N-1.0) generally conforming to IS 14846as per technical Specification given in NIT
33i) DN – 150mm (for H/L Suction & Common delivery header)
34ii) DN – 80mm (for wash out line)
35Supply and delivery ofthree phase actuator operated 100mm diawafer type butterfly valve (PN-1.0) as per Bs-5155and as per technical Specification given in NIT
36i) DN 100 mm (for L/L & H/L individual delivery header)
37Supply delvery at site and storage of Ductile iron Tamper Proof Single Orifice Air Release Valve of DN 50 as per relevanl lS Standard
38i)DN 50 for H/L Commn delivery header)
39Supply, delivery & storage and installation at site M.S. fabricated dismantling joints (P.N–1.0) with rubber compression ring and adjustable follower flanged complete assembley with galvinised stud and nuts,as per technical Specifications given in NIT
40i) DN:150 with length 190 to 265mm (for H/L Suction line)
41ii) DN:150 with length 190 to 265mm (for Commn delivery header )
42iii) DN:80 (for H/L individual delivery line )
43Supply, delivery & storage at site M,S Pipesfor individual pump suction & delivery line from pump discharge upto common delivery header, M.S flanges, bends, specials, etc. as required to make the installation ofdelivery and common delivery header of pumpingmachineries complete in all respects up to the satisfaction of E.I.C.and as per technical Specifications given in NIT
44Supply delivery and storage at site of Electromagnetic Flow Meter with remote indicator cum totalizer unit and cable between the meter and indicatoras per technical specification
45i) DN: 150 (for H/L Common Header header)
46Supply, delivery & storage ofGleeserine type pressure gauge,cast Al. dial along with DN-15 GI impulse line with valve.
47i) (0 – 10 Kg.) 102 mm dia for individiual delivery header
48ii) (0 – 10 Kg.) 150 mm ? for Common Header
49Supply, delivery & storage ofGleeserine type Compound gauge, cast Al. dial along with DN-15 GI impulse line with valve.
50i) (+1 – 1 Kg.) 102 mm ? for individiual Suction line
51Supply, delivery and storage at site of following L.T cables
5270 Sq. mm x 2 nos 3.5 core, 1.1 KV grade, Al. Ar XLPE cable conforming to IS : 7098 (Part – I). From MCCB to PDB cum MCC
5325 Sq. mm 3 core, 1.1 KV grade, Al. Ar, XLPEAcable conforming to IS : 7098 (Part – I). a) 3nos motor x 15mtr =45 mtr
5410 Sq. mm 3 core, 1.1 KV grade, Al. Ar XLPEAcable conforming to IS : 7098 (Part – I).. a) 3nos Sub mersible motor starter to Kiox box x 100mtr =300 mtr
551.5 sq mm , 12 core , 1.1 KVGrade PVC insulatedCopper Armoured control cable as per relevent IS. a) For H/L 3nos actuater x 15 mtr= 45 mtr b) For L/L 3nos actuater x 100 mtr= 300mtr
566 Sq. mm 4 core, 1.1 KV grade, Al. AR, XLPEAcable conforming to IS : 7098 (Part – I). For MCC to Chlorine machine
572.5 sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date. a) 3nos Kiox box to submersible Motorx 50mtr =150 mtr
58N.B-Purchase of all cables should be as per actual site requrement
59Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted415 Volt PDB cum MCC Panelhaving required Feedersas per technical Specifications given in NIT
60Supplying delivery of 200 Amps 415 Volt TPN Sheet steelenclosed HBC Fuse type Heavy Duty Double Break Main Switche with Sidet handle operated For receiving WBSEDCL power
61Supply delivery and storage at site of Ultrasonic type continuous level measuring unit with provision of 4 to 20 mA analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low - low level in suction sumpas per technical Specifications given in NIT
62Supply, delivery and storage at site of automatically controlled Plunger type chlorinator dosing pump with Flow Rate 100 Ltr./Hr. and Max pressure of 10kg/cm2) with all accessoriesfor pump motor, foundation Bolt, suction and discharge flange and with storage tank of dosing solution of 100 Ltr. capacity and the prime mover to be coupled with pump of 0.5 HP 3 Phase 1450 RPM squirrel cage TEFC induction Motor, Motor will be IE3 (Make of Machine: As per attached vendor list of P.H.E Dte.)
63Supplyand delivery63 KVA Oil Coolling type Voltage Stabiliser, having unbalance 250 - 500 V input voltage, and 415(±1%) out put voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with contactor at out put side, input MCB, Ammeter Bell etc. as per I.E rules and as per tecnical specification given in NIT N.B.:- Manufacturer Test Certificate for Stabilizer, core material, winding copper & oil should be produced at the time of delivery
64Supply and delivery of 450mm(H) x 300(L) x 250mm(B) size out door CRCA sheet steelfabricated cubical type kenopy top cable jointing box inside fitted3 nos 100 Amp rated bus bar andhinged type front door and painted powder coated anticorrosive paint as per IP 55 as per direction of E.I.C
65Supply & delivery at site horizontal type centrifugal self priming non-clog dewatering pump with horizontal type 415V ,50 Hz , three phase squirrel cage Induction motor including supply of channel base frame ,coupling and coupling guard complete set Discharge capacity : 5.75 M3/hr Total Head : 10 mtr. Suction/delivery- 40mm/35mm
66Supply and delivery at site 40mm dia G.I pipe. With fittings i.e- Elbow, Union, Nipple. G.M Ball valve. C.I Foot valve etc for making suction and delivery line for dewatering pump.
67Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). a) 40 mm dia [ for Control Cable protection]
68PART-B ( Intallation)
69Installation and commissioningof all items mentioned as in PART A (Exepet item no-16.3, 16.4, 16.6, 20 and 25) including supply of all erection items,as required for installation of Submersible pumping machineris & Centrifugal pumping machineris , all valves, delivery pipe line, PDB cum MCC panel, Voltage Stabiliser,Chlorine system, cable tray, indoor & outdoor light,laying of cable on cable tray includingsupplying all necessary items i.e- nut & bolt wather rubber gasket, with painting, jointing of cables termination cable soketing by suitable rated sockets, jointing the delivery header with H/L & L/L rising main, suporting piller and paining anticorrosive paint etc. including cost ofgas cutting, welding etc. as required for complete the installationas per Hydraulic standard & IE rules in compliance by engaging skilled technician all complete as per Technical specificationand upto entire satisfaction of EIC.
70Installation & commissioning of above chlorinator with supplying & drawing of suitable length 1.1Kv grade 3x36/03(2.5Sqmm) single core standard FRLSh PVC insulated unsheathed copper wire(approved make) from installed panel board through 20mm size PVC rigid conduct FR(Precision make) incl. necessary fittings as required and continuous earthing from nearest earth grid. This includes the cost of making required height brick foundation base with neat cement finishing by supplying all required materials and testing the entire set as per direction of E.I.C(Height of tank foundation shall be higher than that chlorine machine)
71Laying of 1.5Sq mm controll cable through 40 mm dia PVC Schedule-80 pipe in under ground trench, the trench size : 500 mm(W) x 760 mm(D) average depthand also trench to be filled up with shifted soil, levelling up and restoring surface duly rammedas per direction of EIC
72Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on thetop of the cable with 8 (eight) Nos. bricks per metre, includingfilling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
73Supply, delivery Fixing at siteG.I cable tray for laying of power cable and G.I Perforated cable tray for laying of control cable at Pump House having proper M.S. structural supportas per technical Specifications given in NIT
74Earthing & lightning protection for Pump House, electrical installation as per ISS and IE rules andas per technical Specifications given in NIT (2 nos Earth pitfor each intallation)
75Earthing of cable jointingbox with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.incl GI bolts, double nuts, double washers . GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and size86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside)and CI hinged inspection cover of 36.56 cm x 35.56 cm with locking arrangement, and connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised strip By ISI-Medium GI pipe as per NIT Specification
76Lighting and luminaries arrangement at the head works site including internal illumination ofpump house building. as per technical Specifications given in NIT
77Supply delivery and installation at site and storage of safety equipment like 6kg capacity Fire Extinguisher , sand bucket with bracket , rubber mats, shock treatment chart and first aid box, complete as per technical Specifications given in NIT
78Providing & Installation of Solar Photo Voltaic Panels (Mono/Poly Crystalline)as per MNRE and NIeT Specification forsize of solar plantwith necessary PV arraymounted on independent steel structure of suitable height &in a suitable direction to optimize panel use and withstand the wind pressure up to 200 Km /hourincluding necessary 3 phase inverter, cable, switch/circuit breaker/connector/junction box, earthing, lightening arrester, installation & commissioning with 5 year CMC. (a) The PV Modules should be mounted on hot dip galvanized metallic structure of adequate strength and as per drawing given in NIT (b) Components & parts used in the solarsystem including the metallic structure (MS) should confirm to the BIS (c) The rates of solarsystem includes compressive maintenance contract(CMC) for 5 years .
79Construction of RCC foundationfor mounting Steel structure for installation of Solar panel Array including earth excavation, sand filling, brick soling etc and as per speecification given in NIT.
80Cost of supply and delivery at site of calcium hypochlorite granule minimum CI content 60%-65% in air plastic jar (3kg each) as per direction of EIC. (Make PHE approved)
81Supply and delivery of 2(Two) nos Colored cast Plastic Chair & 1(one) nos rectangular foldable potable table as per technical specication given in NIT
82Trial run of pumping machinery, through PLC / Automatic panel also operation of Pumping machineris, Chlorinator, Voltage Stabiliser etc. including operation ofvalves if required and guarding of installationas per direction of E.I.C.( for 90 days) for 2persion
83Add: 18% GST
84Add: 1% Cess
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail