| 1 | Supplyof : |
| 2 | 11 KV link Set (Station type) Suitable for 800 Amp current capacity. (IS: 9920 (Part-I to IV)) with 8 mm Copper Knife |
| 3 | 11 KV link Set (Line type) Heavy duty. Suitable for 800 Amp current capacity. (IS: 9920 (Part-I to IV)) with 8 mm Copper Knife |
| 4 | 11 KV Air break switch with pipe & handle complete (3 phase, 600 Amp) (IS: 9920 (Part-I to IV)) |
| 5 | 11 KV Drop Out Fuse Set 3 Phase 400A (IS:9385 (Part-I to III) as amended upto date) |
| 6 | Gapless Surge Arrestor, 9 KV, 10 KV, LA with (polymer/porcelain) housing, Stn. Type(IS: 3070 Part-3) |
| 7 | 11 KV Pin insulator with pins 12 KN.(IS:731 and IS:3188) |
| 8 | LT Shackle Insulators with Mukki Clamps (16 KN) of Standard Make with Nuts and Bolts |
| 9 | Galvanised Nuts and Bolts of sizes. 6”,7”,8”,9”,11”,12”x1/2” dia half thread. |
| 10 | G.I wire 8 SWG. |
| 11 | Guy wire 7/14 SWG. |
| 12 | Guy rods with turn buckle 5’ long complete |
| 13 | 11 KV tension disc/suspension Disc(IS:731 and IS:3188) |
| 14 | Fabricated GI channel, X-arms of sizes (75x40x6) mm (50x50x6)mm and (100x50x6) mm. |
| 15 | Fabricated GI Angle, (50x50x6mm) |
| 16 | Al. Solderless clamps suitable for transformer1000 KVAas per relevant IS |
| 17 | Al. Solderless clamps suitable for transformer630 KVA as per relevant IS |
| 18 | Al. Solderless clamps suitable for transformer400/500 KVA as per relevant IS |
| 19 | Al. Solderless clamps suitable for transformer250 KVA as per relevant IS |
| 20 | Al. Solderless clamps suitable for transformer100 KVA as per relevant IS |
| 21 | Al. Solderless clamps suitable for transformer63 KVA as per relevant IS |
| 22 | Aluminium Thimbles 1 MVA as per relevant IS |
| 23 | Aluminium Thimbles 630 mm2 as per relevant IS |
| 24 | Aluminium Thimbles 500 mm2 as per relevant IS |
| 25 | Aluminium Thimbles 400 mm2 as per relevant IS |
| 26 | Aluminium Thimbles 300 mm2 as per relevant IS |
| 27 | Aluminium Thimbles 240 mm2 as per relevant IS |
| 28 | Aluminium Thimbles 185 mm2 as per relevant IS |
| 29 | Aluminium Thimbles 120 mm2 as per relevant IS |
| 30 | Aluminium Thimbles 95 mm2 as per relevant IS |
| 31 | Aluminium Thimbles 70 mm2 as per relevant IS |
| 32 | Aluminium Thimbles 35 mm2 as per relevant IS |
| 33 | Aluminium Thimbles 25 mm2 as per relevant IS |
| 34 | Aluminium Thimbles 16 mm2 as per relevant IS |
| 35 | 35 mm sq, 11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster |
| 36 | 50 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster |
| 37 | 70 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster |
| 38 | 95 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster |
| 39 | 120 mm sq,11 kV Aerial Bunched Cable 3 Core + Earth , XLPE as per (IS 7098 Part 2 ammneded upto date) Polycab/Havells/Paramount/Gloster |
| 40 | 16 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 41 | 25 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 42 | 50 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 43 | 185 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 44 | 240 mm2Single Phase Cable 1.1 KV Grade, XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 45 | 300 mm2Single Core Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 46 | 400 mm2Single Core Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 47 | 630 mm2Single Core Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date)Polycab/Havells/Paramount/Gloster |
| 48 | 25 mm23.5 Core armoured Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 49 | 35 mm23.5 Core armoured Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 50 | 50 mm23.5 Core armoured Cable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date)Polycab/Havells/Paramount/Gloster |
| 51 | 185 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 52 | 240 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 53 | 300 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date)Polycab/Havells/Paramount/Gloster |
| 54 | 400 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 55 | 630 mm23.5 CoreCable 1.1 KV Grade,XLPEInsulated Stranded Conductor FRLS type (IS 7098ammended upto date) Polycab/Havells/Paramount/Gloster |
| 56 | Galvanized earthing strips 50mm x3mm. |
| 57 | Bobin Insulators clamps/cliffs. |
| 58 | Back Clamp Collars/Pole Collars G.I. |
| 59 | Galvanized ABC Cable Hooks/I Hooks |
| 60 | Aluminum paint (Asian/Nerolac/Berger) make. |
| 61 | Red oxide paint (Asian/Nerolac/Berger) make. |
| 62 | 11 KV Heat Shrinkable Outdoor Cable Termination Kit |
| 63 | 11 KV Heat Shrinkable Outdoor Cable Jointing Kit |
| 64 | 11 Mtr. (IS 2713 540 SP 56)Steel Tubular Poles |
| 65 | 9 Mtr. (IS 2713 540 SP 33)Steel Tubular Poles |
| 66 | 8 Mtr. (IS 2713 540 SP 15)Steel Tubular Poles |
| 67 | 30mm2 ACSR Conductor IS: 398(Part-II) ammended upto date |
| 68 | 50mm2 ACSR Conductor IS: 398(Part-II) ammended upto date |
| 69 | 100mm2 ACSR Conductor IS: 398(Part-II) ammended upto date |
| 70 | 630 Amp 3 Pole Thermal Magnetic MCCB\"s having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) |
| 71 | 400 Amp 3 Pole Thermal Magnetic MCCB\"s having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) |
| 72 | 200 Amp 3 Pole Thermal Magnetic MCCB\"s having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) |
| 73 | 160 Amp 3 Pole Thermal Magnetic MCCB\"s having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) |
| 74 | 100 Amp 3 Pole Thermal Magnetic MCCB\"s having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) |
| 75 | 63 Amp 3 Pole Thermal Magnetic MCCB\"s having adjustable thermal (0.8 In-1.0 In) .with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage (Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations.(Make: ABB/EATON/HAVELLS/LEGRAND/L&T/SCHNEIDER/SIEMENS) |
| 76 | Rubber shoes sole insulation IS 4770 ammended upto date and working potential of 11 kV |
| 77 | 20 feet long , 11 kV Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , manufactured from Fibre Reinforced Plastic material , having HV test of 110 kV, push button locking sytem, crocodile grounding clamp ,rubber clading to hold, Die cast Alu. Earthing instrument for 30mm diameter (with 4 sq mm copper cable 8 mtrs;top section diameter > 25 mm and bottom section diameter >45 mm)with earthing spike of Standard Make |
| 78 | Battery operated 11-33 kV Voltage Detector (CPRI Tested) complete kit including HV detector probe, 20 feet FRP insulation stick, carrying bag. The detector should haveaudio as well as visual anunciation, sensing distance of 1 meter for 11kV and 3 meters for 33kV. Bright high intensity Red LED\"s for visual annunciation even in unfavourable daylight conditions and a buzzer to produce loud beep audible even in noisy backgrounds |
| 79 | Natural Latex 11kV Rubber Gloves(Type-2IS 4770; ISI Mark)with test voltage >=17000 V and Working Voltage of 11000 with maximum leakage current at tets voltage of 14mA (rms) [ ISI Mark and IS Conformation on Each glove] |
| 80 | White Color Industrial Safety Helmets (IS 2925) with chin-strap and nape-strap with Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance as per IS 2925 [ ISI Mark and IS Conformation on Each Helmet] |
| 81 | Yellow Color Industrial Safety Helmets (IS 2925) with chin-strap and nape-strap with Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance as per IS 2925 [ ISI Mark and IS Conformation on Each Helmet] |
| 82 | Safety Belt with static and dynamic loading completely as per IS 3521 [ ISI Mark and IS Conformation on Each Belt] |
| 83 | UK SIZE 6 and below Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344[ ISI Mark and IS Conformation on Each Shoe] |
| 84 | UK SIZE 7 Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344 [ ISI Mark and IS Conformation on Each Shoe] |
| 85 | UK SIZE 8 Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344 [ ISI Mark and IS Conformation on Each Shoe] |
| 86 | UK SIZE 9 Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344[ ISI Mark and IS Conformation on Each Shoe] |
| 87 | UK SIZE 10 and above Safety Shoe for 11-33kV Working Environment completely as per IS 15298 ISO 20344[ ISI Mark and IS Conformation on Each Shoe] |
| 88 | Complete Tool Kit ( Screw Driver -4 No, Plier-1 No, Spanner (6 to 36)-1 Set, Wrench 12\"-1 No, Measuring tape 25 Mtr-1 No, Hexa Frame with Blade-1 No, Tester-1 No, L Key-1 Set and Combination Spanner (6 to 36)-1 setBOSCH/DEWALT/TAPARIA |
| 89 | Clamp Meter, Conforms to IEC 61010, CAT II 600V safety rated, 600A AC current measurement, AC/DC voltage, resistance, continuity & data hold function, 2 years manufacturer warranty [FLUKE/DIGI SENSE/ MOTWANE/EXTECH] |
| 90 | 18 feet Fiber Link Rod |
| 91 | 18 feet Bamboo Link Rod |
| 92 | Manually Operated Megger (500/1000 Mega Oms) |
| 93 | LT Fuse Set (630 Amp) 11 KV Polymer Type |
| 94 | GI Chemical earthing 2 mtr with Chemical Bag |
| 95 | Search Light (LED) 1 km Range |
| 96 | Bamboo Ladder 18\" Long |
| 97 | Aluminium folding ladder 20 ft Long |
| 98 | Wooden Ladder A Class Budloo [Finished Length of 17\" (3\" by 1.5\") ; Finished Step (2\" by 1.5 \") ; Bottom Width 18\"; Step to step distance 13\"]alongwith MS Straps on both side of each step |
| 99 | 16 mm² Cable (2C) from LT Line to meter ,1.1K V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type(IS 1554 Part 1 ammended upto date) Polycab/Havells/Paramount/or Equivalent |
| 100 | 25 mm² Cable (2C) from LT Line to meter ,1.1K V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type(IS 1554 Part 1 ammended upto date) Polycab/Havells/Paramount/or Equivalent |