Tender For Provn Of Facade Lighting For Sudan Block At Nda Khadakwasla
Tender Overview
Project Description
Provision Of Facade Lighting For Sudan Block At Nda Khadakwasla
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-Apr-2023 | CORRG | Date | 24-Apr-2023 |
| 2 | 15-Apr-2023 | REVISED BOQ AND AMDT TO TENDER DOCUMENT | BOQ | 24-Apr-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing testing & commissioning ofColor changing RGBW surfacemounted Narrow/Medium/Wide beam luminaire suitable for outdoor applicationsofFacadeLighting,depending on design as per site requirement and directed by Engr-In-Charge.LuminairesshouldbeenabledwithhighpowerLEDs, shouldconsistsofanti-agingandanti-UVhighoptical efficiency temperature-resistant lenses, suitable for architectural lighting as per design requirement.The luminaire should have options for various beam angles i.e. from 15°/25°/35°actual will depend on the design as per site requirement. RGBW LED luminaries having75W at steady state full intensity, Luminaire luminous flux range of 2800- 3080 Lumens. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt and each light fixture should be invidually addressable & should be able to operate with any standard DMX512 equipment.Color renderingindexCRI=80 for white LEDS\"sand powerfactorof complete luminaire = 0.90, at full intensity.Luminaire should be provided with suitable integral/separate non-integral power supply unit.LumenmaintenanceofatleastL70@50,000burning hours at 25°C.Theluminaireshouldhavepowdercoatingpressuredie castaluminiumhousingwithminimum3-4mmthick safety glass.Ingress Protection = IP 66. Impact resistance level = IK 08. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%. THD should be less than 15%. Housing to have adjustable base bracket for angle adjustment sothatthelight directioncanbeadjustedto illuminate desired structural elements.Connectorsif used shouldbe IP67male/femaleconnectorsfor loop through wiring.The LED Luminaires and external drivers drivers if used should be BIS certified.The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted by the contractor before the installation of Luminaries complete all as specified and directed.Make - Bajajcat part - BA FL IN1 S 75W RGBW or equivalent in Philips catpart- blast powercore gen5orWiprocat part -Arcus LF27-901-040-CC-XX Note for item No-1 to 3 : Quoated rate includes scafffolding work for installation of luminaries as per site requirement and as directedby engineer-in-charge and safety norms to be followed |
| 2 | Supply and fixing testing and commissioning ofColor changing RGBW surfacemounted Narrow/Medium/Wide/Elliptical beam luminaire suitable for outdoor applicationsofFacadeLighting,depending on design asper site requirementand directed by Engr-In-Charge. LuminairesshouldbeenabledwithhighpowerLEDs, shouldconsistsofanti-agingandanti-UVhighoptical efficiency temperature-resistant lenses, suitable for architectural lighting as per design requirement.The luminaire should have options for various beam angles i.e. from 8°/15°/25°/35°/10°x60°/15°x45° actual will depend on the design by the contractor and site requirement.RGBW LEDLumanaries having36 W at steady state full intensity, Luminaire luminous flux range of 2450- 2580 Lm. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt and each light fixture should be invidually addressable & should be able to operate with any standard DMX512 equipment. Color renderingindexCRI=80 for white LEDS\"sand powerfactorof complete luminaire = 0.90, at full intensity.Luminaire should be provided with suitable integral/separate non-integral power supply unit.LumenmaintenanceofatleastL70@50,000burning hours at 25°C. Theluminaireshouldhavepowdercoatingextrudedaluminium alloy housingwithminimum3-4mmthick safety glass.Ingress Protection = IP 66. Impact resistance level = IK 07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%. THD should be less than 15%. Housing to have adjustable base bracket for angle adjustment sothatthelight directioncanbeadjustedto illuminate desired structural elements.Connectorsif used shouldbe IP67male/femaleconnectorsfor loop through wiring.The LED Luminaires and external drivers drivers if used should be BIS certified.The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted by the contractor before the installation of Luminaries complete all as specified and directed. .Make -Bajaj catpart - BA WW IN1 AS 36 W RGBW or equivalent inPhilips catpart- graze powercore Gen 5 or Wipro - cartpart- Arcus LF27-601-040-CC-XX |
| 3 | Supply and fixing testing and commissioning ofColor changing RGBW surfacemounted Narrow/Medium/Wide/Elliptical beam luminaire suitable for outdoor applicationsofFacadeLighting,depending on design asper site requirementand directed by Engr-In-Charge. LuminairesshouldbeenabledwithhighpowerLEDs, shouldconsistsofanti-agingandanti-UVhighoptical efficiency temperature-resistant lenses, suitable for architectural lighting as per design requirement.The luminaire should have options for various beam angles i.e. from 8°/15°/25°/35°/10°x60°/15°x45° actual will depend on the design by the contractor and site requirement.RGBW LEDLumanaries having60W at steady state full intensity, Luminaire luminous flux range of 2450- 2580 Lm. Light fixture should be standard DMX512 protocol compatible, the DMX decoder function should be inbuilt and each light fixture should be invidually addressable & should be able to operate with any standard DMX512 equipment. Color renderingindexCRI=80 for white LEDS\"sand powerfactorof complete luminaire = 0.90, at full intensity.Luminaire should be provided with suitable integral/separate non-integral power supply unit.LumenmaintenanceofatleastL70@50,000burning hours at 25°C. Theluminaireshouldhavepowdercoatingextrudedaluminium alloy housingwithminimum3-4mmthick safety glass.Ingress Protection = IP 66. Impact resistance level = IK 07. Adequate heat sink with proper thermal management shall be provided. Operating Temperature : -10°C to +45°C, Operating Humidity : 10%-90%. THD should be less than 15%.Housing to have adjustable base bracket for angle adjustment sothatthelight directioncanbeadjustedto illuminate desired structural elements.Connectorsif used shouldbe IP67male/femaleconnectorsfor loop through wiring.The LED Luminaires and external drivers drivers if used should be BIS certified.The fixtures proposed must have passed LM 79 & LM-80, Reports from NABL laboratory will be submitted by the contractor before the installation of Luminaries complete all as specified and directed. .Make -Bajaj Catpart-BA WW IN1 AS 60W RGBW or equivalent in Philips Catpart- graze powercore gen 5orWipro Catpart -Arcus LF27-901-040-CC-XX |
| 4 | Supply and fixing of DMX Controller System with Standalone interfaces. Controller should deliver 512 DMX channels, the controller should have the provision to ugrade its channels upto 1536 by adding 2 more DMX universe. the controller should have new Nicolaudie Stand Alone engine (NSA) offering some great possibilities (multi-zone, extended triggers, 16-bit channels management...). the controller should offer multiple possibilities to trigger your lighting scenes: time/date, input ports, TCP/UDP commands. The controller should have LS Cloud (activation required) as an optional feature to manage your lighting controller from anywhere in the world, at anytime using internet connectivity. PC DMX IN triggers:Yes, Standalone DMX IN triggers: Only with 512 interfaces, External triggers: x8 dry contacts (5V) internal calendar: Yes, Backups of theinternal clock: Yes, 3weeks without power, Memory card: Yes microSD card, 4GB max, Input power voltage: 8-15V DC with power adaopter,. via USB(USB power supply included), Trigger lighting scenes using calendar triggers and conditional rules with New Stand Alone engine, using contact ports, RS232 or over Ethernet. Stand Alone mode with 99 scenes across 5 zones. Buttons: Rotary switch for scene selection. iPhone/iPad/Android remote and programming apps. Temperature: 0 to +50 C°, DMX Compatibility: 8 and 16 bit DMX fixtures, System Compatibility: Windows XP, Vista, 7, 8, 8.1, 10, MAC OS X(10.6 and +), Linux. complete all as specified and directed.Make : Bajaj / philps / wipro |
| 5 | Supply and fixing of DMX Splitter cum Booster ,Input Power- 100 to 240 VAC, auto-ranging, 50/60 Hz.,Housing rugged alluminium, Operation Temperature -17ºC ~ +55ºC (0ºF ~ 131ºF) , 5/6 output ports with 3/5-pin terminal sockets , each port should be optically isolated , Protection Rating IP20 including connection complete all as specified and directed.Make : Bajaj / philps / wipro |
| 6 | Supply and fixing of IP65 Junction Boxes DK 0202G with Connector DK KH 04/ DK KL 04 complete all as specified and directed. Make : Hensel/Sintex/National |
| 7 | Supply and fix of Server RACK 9U for theDMX splitter and controller complete all as specified and dircted. Make: Valrack/D-link |
| 8 | Supply and fixing of Cat 06, 4 Pair twisted wire UTP 23 AWG pure copper unsheilded PVC Bulk Cable (305 mtr per roll) as per ISI/ BIS standard complete all as specified and dircted. Make : Havells/Polycab/Finolex |
| 9 | M & L for PVC insulated2.5 sqmm 4 core copper conductor, 1100 voltsFRLS grade ISI marked including PVC conduit pipes of dia not less than 19 mm complete all as specified and directed.Make : FINOLEX /PLAZA / ANCHOR / HAVELLS / NICCO / POLYCAB/Gloster |
| 10 | Supply & fixing of lighting control system along with versatile wall mounted button panel device acting as interface to trigger different themes as per site requirement and complete all as specified and dircted. |
| 11 | Provion for programming of software with 08 nos of themesby Qulaified Rep of OEM, complete testing and trial run of themes as per site requirement upto satisfaction and approved by of GE,completeall as specified and dircted |
| 12 | Material and labour of Aluminum composite panelsheets (ACP Cladding) including 1/1.5mm aluminium pipe including necessary harware such as drilling iron screws, double tape, silicon dow, masking tape etcas per site requirement complete all as specified and dircted. Make : (a) M/s Umiya Fexifoam Pvt Ltd(b) Aludecor(c ) Alstrong(d) Alucobond ( e) Alstone(f) Viva (g) Ashoka Foam Multiplast Ltd (Brand- Alutuff ACP & Alutuff AHPL) (h) Virgo Laminates |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender