| Sl. No. | Item Description |
| 1 | Excavation in trenches n. exc. 1.5 M in width and 1.5 M in deep for laying of cableand getting out in Soft / loose soil complete all as specified and directed |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm complete all as specified and directed. |
| 3 | Removing excavated material n. exc. 50 M away, depositing as directed at level n. exc. 1.5 M above starting point complete all as specified and directed . |
| 4 | M&L for providing crushed stone sand cushioning to UG cable including punning down of sand in layers complete all as specified and directed.Note: Punned thickness only shall be measured. |
| 5 | Takingout serviceable unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mmduring excation of trenches and relaying after cable laying in trenches all asspecified and directed |
| 6 | Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches complete all as specified and directed |
| 7 | Taking downGI pipelaying in trenches for UG cable protectionof any sizes pipe complete all as specified and as diercted. |
| 8 | Supply and lay in trenches / along the wall / floorpipes GI light grade of size 50 mm with and including all fittings and accessories for cable protectioncomplete all as specified and directed |
| 9 | Supply and lay in trenches / along the wall / floorpipes GI light grade of size 80 mm with and including all fittings and accessoriesfor cable protection complete all as specified and directed |
| 10 | Taking downany sizes ofof LT UG cable XLPE with aluminum conductor multistranded ,PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable complete all as specified and as directed. |
| 11 | Supply and lay cable XLPE Insulated armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 10 sq mm 4 Core complete all as specified and directed. |
| 12 | Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 16 sq mm 4 Core complete all as specified and directed. |
| 13 | Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 25 sq mm 3.5 Core complete all as specified and directed. |
| 14 | Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sq mm 3.5 Core complete all as specified and directed. |
| 15 | Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 50 sq mm 3.5 Core complete all as specified and directed. |
| 16 | Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 70 sq mm 3.5 Core complete all as specified and directed. |
| 17 | S&F Cable jointing kit for 1100V (Earthed) grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed |
| 18 | M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well rammaing wateringfinish suraface 10 cm from top using PCC 1:3:6 including removal of surplus soil complete all as specified and directed |
| 19 | M & L for maintenance free chemical Gel based earthing,vGI pipePipe having 75 mm dia 3 mtr long with25 Kg back fill compound all as required at siteincluding testing on completion and taking down of old earthing all as directed by Engr in-Charge including FRP cover of suitable sizeNote : (a) Earth resistance of earth pit should be less than 1.0 Ohms on testing after completion. If the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 20 | Supply and fix in replacement FRP cable looping box of size 250mm x 150mm x 100mm With connector block 4 Way , 1 Nos of MCB SP 6 Amp 10KA,etcincluding suitable Brass gland, including provision for connecting earth continuity conductor etc. all as specified and directed. |
| 21 | Demolation of Cement concrete in ground floor and paving exc 15 cm thickness but aboveground level including removal all as specified. |
| 22 | M&L for PCC (1:3:6)type B1 (using 20 mm graded stone aggregate as in sub base to floor 100 mm thick finished even and smooth without using extra cement complete all as specified and directed. |
| 23 | Supply andin repairs MCCB DB verticle type made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link,IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door all as specified and directed by engr in charge |
| 24 | Supply in repair MCCB DB verticle type made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link,IP-43-IK09 protection grade , 415Volts TPN with 8 way Double door ,all as specified and directed by engr in charge |
| 25 | Taking down any type any breaking capacity MCCB complete all as specified and as directed. |
| 26 | S & F in replacement MCCB 415 volts grade with adjustable short circuit and over load of following rating :- Make: L&T/Havells/Legrand |
| 27 | (a) 63 Amps, 25 KA, 3 Pole |
| 28 | (b) 100 Amps, 25 KA, 3 Pole |
| 29 | (c) 125 Amps, 25 KA, 3Pole |
| 30 | (d) 160 Amps, 36 KA, 3 Pole |
| 31 | (e)200 Amps, 36KA, 3 Pole |
| 32 | (f) 250 Amps, 36 KA, 3 Pole |
| 33 | (g) 400 Amps, 36 KA, 3 Pole |
| 34 | M&L for MS chequered plates Fe 410-W (Gde E- 250) Quality \"A\" of not less than 6 mm thick ofsizes as per site requirement incl cutting , welding of strip on the edges for proper fixing and provn ofhandles for lifting & fixing arrangementas shown & directed.incltaking out the old & unserviceble chequered plates all as directed. |
| 35 | Material and Labour scrapping to existing LT Panels/ Feeder pillar boxes of out side surfaces and applying two coats of synthetic enamelled paint on out side/ exposed surfaces of LT panels and LT feeder pillar boxes and including cleaning of Metering equipement system,Indication lamps,selector switches etc complete all as specified and directed by Engineer-in-Charge |
| 36 | Material and Labour for repairing of LT Panelof not exc of sizes 2.5 Mtr x 2 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge |
| 37 | Material and Labour for repairing of LT Panelof not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge |
| 38 | Material and Labour for repairing of feeder pillar boxof not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge |
| 39 | Supply in repair LED indication lamp for indication of (R,Y,B) 230 Volts includingconnections and taking out unserviceable indication Lamp complete all as specified and directed |
| 40 | Supply in repair Volt meter 0-500 Voltdigital type includingconnections and taking out unserviceable Volt meter complete all as specified and directed |
| 41 | Supply in repair Ampere meter 0-400Amps digital type includingconnections and taking out unserviceable Ampere meter complete all as specified and directed |
| 42 | Supply in repair Selector switch for Volt meter4 way Knob type (0FF, RB,RY,BY) includingconnections and taking out unserviceable selector switch complete all as specified and directed |
| 43 | Supply in repair Selector switch for Amp meter 4 way (0FF,R,Y,B) Knob type includingconnections and taking out unserviceable selector switch complete all as specified and directed |
| 44 | S&F copper cable flexiblePVC insulated 3 x 2.5 sqmm single core along with earth wire in PVC conduit from FRP box to street light fitting ,including aluminium flat clampt 25 X 4 mm -03 Nos with suitable nuts,bolts and washers etc all as specified and directed by Engr-in-Charge |
| 45 | Supply in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed by Engr in charge. |
| 46 | Supply in repair LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed by Engr in charge. |
| 47 | Supply in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.all as specified and directed by Engr in charge. |
| 48 | Checking/ Testing of resistance value of any type of earth pits by disconnecting earth continuity conductor from test terminal block and reconnecting the earth continuity conductor after testing.Note: (i) Temporary earthing connection to be provided while testing.(ii) Earth tester will be provided by MES.(iii) Contractor has to prepare sketch of earthings indicating the locations in surrounding E&M installations and purpose of earthings(iv) Earth test results shall be recorded in reference to sketch.(v) Earthing to be tested half yearly .(v) If earth test result is not satisfactory , earthing test will be carried out again after maintenance and this will be paid separately.(vi) Earth test to be signed by Rep of contractor, Rep of MES , Test reports to be submitted in triplicate.Details of number of earthing - E& M installations-45 Nos, |
| 49 | M&L for maintenance of GI Plate/copper pipeearthing to improve the earth resistance as following:-(a) Remove the earth pit carefully and kept at site for reuse. If existing pit is already damaged then new pit will be provided, measured & paid separately.(b) Excavation in any type of soil and rock 0.5 cum (approx 0.75m x 0.75m x 0.9m depth )(c) On First day recharge the earth pit with common salt, Magnisium sulphate,back fill compoundmixed with water.(Approx salt- 10 kg, Mg sulphate- 10 kg, Back fill compound - 10 kg )(d) On the next day recharge the earth pit with water 500 ltrs on next day.(e) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(f) Refill the pit with M&L for black cotton soil 0.5cum.(g) Refit the earth pit in place.(h) Testing of earth ( to be measured and paid separately)Note:-(i) Common salt, Mg sulphate, back fill compound will be measured and paid separately.. |
| 50 | M&L for maintenance ofGI plate earthing to improve the earth resistance as following:-(a) Remove the earth chamber carefully and kept at site for reuse. If existing chamber is already damaged then new chamber will be provided, new chamber will be measured & paid separately.(b) Excavation in any type of soil and rock 1 Cum(approx 0.75m x 0.75m x 2 m depth )(c)Taking outGI Earth plate , watering pipe , funnel , earth continuty GI strip, cleaning of GI earth plate and GI stripwith wire brush and polish paper , cleaning of GI pipe and funnel and renistall the the same(d) GIstrip shall be fitted with GI plate byGI nutbolts - 3 nos and in addition weldingto be caried out , weld length between GI plate and GI strip not less than 30 CMon both side of strip (e) On First day recharge the earth pit withcharcoal ,common salt, back fill compoundmixed with water and black cotton soil (Approxcharcoal- 25 KG, salt- 25 kg, Back fill compound - 25 kg, black cotton soil 0.5 Cum(f) On the next day recharge the earth pit with water 500 ltrs on next day.(g) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled (h) Refill the pit with M&L for black cotton soil 0.5cum.(j) Refit the earth chamber in place.(k) Testing of earth ( to be measured and paid separately)Note:- charcoal , Common salt,back fill compound will be measured and paid separately.. |
| 51 | M&L for maintenance of copper plate earthing to improve the earth resistance as following:-(a) Remove the earth chamber carefully and kept at site for reuse. If existing chamber is already damaged then new chmber will be provided,new chamber will bemeasured & paid separately.(b) Excavation in any type of soil and rock 1 Cum(approx 0.75m x 0.75m x 2 m depth )(c)Taking outCopper Earth plate , watering pipe , funnel , earth continuty copper strip, cleaning of copper earth plate and Copper stripwith wire brush and polish paper, cleaning of GI pipe and funnel and renistall the the same(d) copperstrip shall be fitted with copper plate bybrassnutbolts - 3 nos and in addition brazing to be caried out , brazing length between copperplate and copper strip not less than 30 CMon both side of strip (e) On First day recharge the earth pit withcharcoal ,common salt, back fill compoundmixed with water and black cotton soil (Approxcharcoal- 25 KG, salt- 25 kg, Back fill compound - 25 kg, black cotton soil 0.5 Cum(f) On the next day recharge the earth pit with water 500 ltrs on next day.(g) Excavated material to be removed from the site and deposited at the distance not exceeding 50m distance and levelled .(h) Refill the pit with M&L for black cotton soil 0.5cum.(j) Refit the earth chamber in place.(k) Testing of earth ( to be measured and paid separately)Note:- charcoal , Common salt,back fill compound will be measured and paid separately.. |
| 52 | M&L for fixing earth indicators made out of 3 mm thick MS sheet of size 200 mm x 300 mm duly fixed in MS angle iron 25 mm x 25mm of 600 mm long fixed to ground by means and including necessary cement concrete foundation and painting with one coat of synthetic enamel paint over a coat of red oxide primer complete for writing earth reading and connected plant/ panel etc. and excavation and earth work complete all as specified and as directed. |
| 53 | Material and labour for supply, installation, testing and commissioning of copper pipe electrode earthing maintenance freeearthing based on 3 mtr long copper pipe 50 mm dia(ID) with wall thickness of 2 mm, copper strip in pipe and filled with MFC for improvement of conductivity of electrodeduly fixed with connector at top connection of copper strip 25X3 mm riveted /nut bolt after 12 mm boring and further earth continuity conductor made of copper strip 25x3 mm upto 7.5 meter ,60 KGS BFCshall befilled around the copper pipe elecrode ,including providing FRP pit cover of size 250mm X 250mm X 250mm complete as per manufacturer specification and complete all as specified and directed by Engr-in-Charge.Note:- (i) Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed.(ii) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3ohm with single earthing, Any additional work and material required to achive the required result is included in the cost(iii) Earth strip beyond 7.5m shall be measured and paid separately.(iv) Rate is included for boring of earthing in any type of soil/rock,minimum dia of bore 150mm.(v) Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority. Make of Earthing electrode and BFC.(a) KP TRODES sangli or equivalent with prior approval of Accepting Officer. |
| 54 | Material and labour for supply, installation, testing and commissioning of GI pipe electrode earthing maintenance freeearthing based on 3 mtr long GI pipe 50 mm dia(ID) medium grade, GI strip in pipe and filled with MFC for improvement of conductivity of electrodeduly fixed with connector at top connection of GI strip 32X6 mm riveted /nut bolt after 12 mm boring and further earth continuity conductor made of GI strip 32x6 mm upto 7.5 meter , 60 KGS BFC shall be filled around the GI pipe electrode including providing FRP pit cover of size 250mm X 250mm X 250mm complete as per manufacturer specification and complete all as specified and directed by Engr-in-Charge.Note:- (i) Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed.(i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(iii) Earth strip beyond 7.5m shall be measured and paid separately.(iv) Rate is included for boring of earthing in any type of soil/rock,minimum dia of bore 150mm.(v) Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.Make of Earthing electrode and BFC.(a) KP TRODES sangli or equivalent with prior approval of accepting officer. |
| 55 | M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mmby means of bolts, nuts, checknuts & washers of copper and connecting to test point, providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs,including copper earth strip 20 x 3 mmwith GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified.Note-- (i) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3ohm with single earthing, Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. |
| 56 | M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.Note:-(i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. |
| 57 | Taking down old strip of any type and size complete all specified and directed |
| 58 | S & F GI earth continuity conductor or main earthing lead of size 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as directed. |
| 59 | S & F Copper earth continuity conductor or main earthing lead of size 25x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as directed. |
| 60 | S & F copper earth continuity conductor or main earthing lead of size 20x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as directed. |
| 61 | S & F GI wire 4mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as directed. |
| 62 | Taking down oldunserviceable earth copper wireof any type and size complete all specified and directed |
| 63 | S&F in repair of PVC insulated single core unsheathed multistranded cable FR, green colour with copper conductor size 6 sqmm for voltage grade upto 1100 volts. |
| 64 | S&F in repair of PVC insulated single core unsheathed multistranded cable FR, green colour with copper conductor size 10 sqmm for voltage grade upto 1100 volts. |
| 65 | Taking down old Test point of any type and size complete all specefied and directed |
| 66 | Supply and fix repairs Test point terminal box made up of gunmetal or phosphous bronze 75mmx75mmx25mm |
| 67 | Supply and fix in repair Test point Air termination, single pointed, copper rod 12 mm dia and 300 mm long complete all as specified and directed by Engineer-in-charge |
| 68 | Supply and fix in repair Test point Air termination, single pointed, Aluminium rod 12 mm dia and 300 mm long complete all as specified and directed by Engineer-in-charge |
| 69 | Porcelain insulator with nut bolt and washer suitable for fixing copper/gil/Aluminium strip on wall or ceiling |
| 70 | Supply and fix sheet steel enclosure for test terminal block of size 150x150 mm made out of 2 mm thick dully Powder Coated CRCA sheetfor fixing test terminal blockall as directed |
| 71 | Supply and fix sheet steel enclosure for test terminal block of size 150x150 mm made out of 2 mm thick dully Powder Coated CRCA sheetfor fixing test terminal blockall as directed |
| 72 | Supply of supporting GI guyed mast 10 Mtrs with mounting stand & guying wire rope U clamps etc with mountigs and fixing accessories |
| 73 | Supply of lighting strike recorder ( 6 digit Display ) of non resettable type of an IP 65 enclouser with mimimum sensitivity of 1000 A and maximum cpapcity of 220 KA (8/20microsec wave form) tested as per IEC 60 -1 :1989 Model - PP-MAP-LSR |
| 74 | M&L for periodical Servicing of Air conditioner Splittype of capacities 1.5 to 2.0 TR complete with dismantlinginternal and external units into components , cleaning of components fan motor, blower, housing, filters etc.Checking up and rectificationto wiring and connections,cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories,reallignment of the fan coil unit and replacement of drain / condense pipe , connecting up and testing, to make the unit in fully working condition complete all as specified and directed by Engineer-in-Charge.Note:1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labour Charge for on site repairs is deemed to be included in the quoted rate of the job all as specified and directed. |
| 75 | M&L for periodical Servicing of Air conditioner Splittype of capacities 1.5 to 2.0 TR complete with dismantlinginternal and external units into components , cleaning of components fan motor, blower, housing, filters etc.Checking up and rectificationto wiring and connections,cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories,reallignment of the fan coil unit and replacement of drain / condense pipe , connecting up and testing, to make the unit in fully working condition complete all as specified and directed by Engineer-in-Charge.Note:1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labour Charge for on site repairs is deemed to be included in the quoted rate of the job all as specified and directed. |
| 76 | All as per Item No,s 01 here in before but for Airconditioner window type of capacity 1.5 TR all as specified and directed. |
| 77 | Supply and fix only the followingspares incorporated during the repairs to Air conditioner Split / Window type vide Sl Item No. 1 here- in- before but Supply and fix only Capacitor for AC 1.5 TR - 2.0 TR all as specified and directed. |
| 78 | Supply and fix in repairs only Capacitor for Condensing Fan Motor all as specified and directed. |
| 79 | Supply and fix in repairs only Starting Relayall as specified and directed. |
| 80 | Supply and fix in repairs only Evaporator Fan / Blower for for WindowAC all as specified and directed. |
| 81 | Supply and fix in repairs only Printed Circuit board for inverter split AC as per sample all as specified and directed. |
| 82 | Supply and fix in repairs only Filter Drier all as specified and directed. |
| 83 | Supply and fix in repairs only Condenser Fan Motor for split AC 1.5 TR all as specified and directed. |
| 84 | Supply and fix in repairs only Condenser Fan Motor for split AC 2 .0 TR |
| 85 | Supply and fix in repairs only Compressor Sealed Unit for AC of capacity 2.0 TR all as specified and directed. |
| 86 | Supply and fix in repairs only Compressor Sealed Unit for AC of capacity 1.5 TR all as specified and directed. |
| 87 | Supply and fix in repairs only Condensor Unit for air conditioner all as specified and directed. |
| 88 | Supply and fix in repairs only Blower motor for Split type AC as per sample all as specified and directed. |
| 89 | Supply and fix in repairs only Condenser Fan Motor for Window ACAs per Sample all as specified and directed. |
| 90 | Supply and fix in repairs only Thermostat Switch all as specified and directed. |
| 91 | Supply and fix in repairs only Swing motor for Split AC all as specified and directed. |
| 92 | Supply and fix in repairs only Evaporator Fan / Blower for for Split AC all as specified and directed. |
| 93 | Supply and fix in repairs only Cooling Coil all as specified and directed. |
| 94 | Supply and fix in repairs only Over Load Protection Coil all as specified and directed. |
| 95 | Supply and fix in repairs only Copper Capillary tube of Air Conditioner all as specified and directed. |
| 96 | Supply& fix in repair including taking down old one out door unitcabinets with out compressor for split type AC ofcapacity for AC 1.5 TR all as specified and directed. |
| 97 | Supply& fix in repair including taking down old one out door unitcabinets with out compressor for split type AC ofcapacity for AC 2.0 TR all as specified and directed. |
| 98 | Supply& fix in repair including taking down old one indoor unit for split type AC ofcapacity for AC 1.5 TR all as specified and directed. |
| 99 | Supply& fix in repair including taking down old one indoor unit for split type AC ofcapacity for AC 2.0 TR all as specified and directed. |
| 100 | M&L for periodical repairs and maintenance of water cooler of cooling capacity upto40 /60 Ltrs / Hr and storage capacity upto 80 /120 Ltrs complete with disconnecting the water connection, inserting dead plug, dismantling the fan motor, taps, fan blades, condenser etc.Checking up and rectificationto wiring and connections, replacement of necessary parts and accessories, cleaning of the cold water tank, piping, refrigerant lines, reallignment of the fan coil unit and replacement of drain pipe , connecting to water mains and testing to make the unit in fully functional condition. Note: 1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labor Charge for On site repairs is deemed to be included in the quoted rate of the job.all as specified and directed. |
| 101 | Supply and fix in repairs onlythe spares incorporated during the repairs to Water Cooler vide Sl Item No.26 herein before.-Thermostatswitch with knob |
| 102 | Supply and fix in repairs only Push tap inner / outer thread chromimum plated of size 1/2 \".all as specified and directed. |
| 103 | Supply and fix in repairs only Rubber gasket with PVC sheet for Top Lid all as specified and directed. |
| 104 | Supply and fix in repairs only Condenser fan motor for water cooler.all as specified and directed. |
| 105 | Supply and fix in repairs only Capacitor for water cooler all as specified and directed. |
| 106 | Supply and fix in repairs only Starting Relay as per Sample all as specified and directed. |
| 107 | Supply and fix in repairs only PVC Hose Pipe size 3/4 \" to 1 \" all as specified and directed. |
| 108 | Supply and fix in repairs only Waste water tray as per sample all as specified and directed. |
| 109 | Supply and fix in repairs only Compressor Sealed unit for water cooler of capacity upto 120Ltrs all as specified and directed. |
| 110 | Supply and fix in repairs only Condenser unit for water cooler all as specified and directed. |
| 111 | Supply and fix in repairs only Overload protection for Water cooler all as specified and directed. |
| 112 | Supply and fix in repairs only Capillary tube of water cooler all as specified and directed. |
| 113 | S & Fix in repairs ball brass valves, high pressure with Polyethylene float and flynut complete screwed for Iron pipe on or brass ferrule and fixed of size 15 mm dia all as specified and directed. |
| 114 | Supply and fixing in repairsSheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 32 Amps 240 Volts all as specified and directed. |
| 115 | S&F in repairs stop gun metal gate or globe valves with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15 mm dia.all as specified and directed. |
| 116 | Taking down geyser of capacity 25 to 50 Ltrs from the location after disconnecting electric and water connection carefully and sealing cable ends and water pipe for repair or removing to store for safe custody & stripping down, testing of tank, and connecting up carrying out repairs complete all as directed by EIC at site.Note: 1. Equipment Shall be serviced once ina Month and no repeat maintenance shall be measured.2. Spare replaced during the process of repair shall be measured and paid separatelyas a supply only under relevant item here-in after.all as specified and directed. |
| 117 | Supply and installin repair including taking down old one water heater storage type of capacity 25 liters glass lined coated inner tank, suitable for high pressure and pressure pump installation 02 KW heating elements fire retardant cable with 3 pin plug etc complete all as specified and as directed by EIC.Make: Havells/ Bajaj |
| 118 | Supply and install in repairincluding taking down old one water heater storage type of capacity 50 liters glass lined coated inner tank, suitable for high pressure and pressure pump installatrion 02 KW heating elements fire retardant cable with 3 pin plug etc complete all as specified and as directed by EIC.Make: Havells/ Bajaj |
| 119 | Supply and fix only the sparesincorporated during the repair to geysers vide Sl Item no 46 herein before for Heating Coil 2 KW all as specified and directed. |
| 120 | Supply and fix in repairs only Heating Coil 1.5 KW all as specified and directed. |
| 121 | Supply and fix in repairs onlyThermostat all as specified and directed. |
| 122 | Supply and fix in repairs only Copper Water tank for Geyser of capacity upto 25 Ltrs all as specified and directed. |
| 123 | Supply and fix in repairs only Non return valve Brass Chromium plated 15 mm / 20 mm all as specified and directed. |
| 124 | Supply and fix in repairs only Safety valve with anti vacuum pressure reducing HPRV all as specified and directed. |
| 125 | Supply and fixing of PVC Cable entry tray of size 100 MM X 75 MM for entry of copper capillary tube and PVC hose pipe of water all as specified and directed. . Make Legrand or equivalent |
| 126 | S & F in repair ac stand outdoor unit as per sample all as directed all as specified and directed.. |
| 127 | M & L for refrigent charging /Top up to Air conditioners/water coolers complete all as directed and specified. |
| 128 | Supply and fixing in repairs of insulation over and aroundcopper tubing to be fitted across the whole length of copper tubing incl all fixing arrangements and checking for insulation leakages if any all as directed |
| 129 | M&L for periodical Servicing ofRefrigerator of any capacities complete with dismantlinginternal and external units into components , cleaning of components fan motor, blower, housing, filters etc.Checking up and rectificationto wiring and connections,cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories,reallignment of the fan coil unit and replacement of drain / condensate pipe , connecting up and testing, to make the unit in fully working condition complete all as specified and directed.Note:1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labour Charge for on site repairs is deemed to be included in the quoted rate of the job |
| 130 | S & F in repair of freezer basket as per sample all as directed. |
| 131 | S & F in repair of refrigerator locks as per sample all as directed. |
| 132 | S & F in repair of refrigerator bulb as per sample all as directed. |
| 133 | S & F in repair of handle as per sample all as directed. |
| 134 | S & F in repair of defrost heater as per sample all as directed. |
| 135 | S & F in repair of condensor coil of refrigerator as per sample.all as directed. |
| 136 | S & F in repair of evaporator of refrigerator as per sampleall as directed. |
| 137 | Supply and fix copper pipe of size 5/8 all as directed. |
| 138 | Supply and fix copper pipe of size 1/4 all as directed. |
| 139 | Supply and fix copper pipe of size 1/2 all as directed. |
| 140 | Supply and fix NRV copper of size 1/4 and 1/2 all as directed. |
| 141 | Supply and fix NRV Copper of size 5/8 all as directed. |
| 142 | Supply and fix PVC Drain pipe of suitable Size all as directed. |
| 143 | Supply and fix remote control for Splt AC all as directed. |