Bharat Sanchar Nigam Limited-BSNL has published Tender For Melarmath Type Iii Pt Quarter Complex Agartala. Submission Date for this Tender is 11-04-2023. Drainage Tenders in West Tripura Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
2 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
3 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
4 | Cement mortar 1:4 (1 cement :4 coarse sand) |
5 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
6 | Kiln seasoned and chemically treated hollock wood. |
7 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) |
8 | Kiln seasoned and chemically treated hollock wood |
9 | 30 mm thick shutters |
10 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
11 | Float glass panes |
12 | 4 mm thick glass pane (weight not less than 10 kg/sqm) |
13 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
14 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
15 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
16 | Fixed to openings /wooden frames with rawl plugs screws etc. |
17 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
18 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
19 | 250x16 mm |
20 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
21 | 250x10 mm |
22 | 150x10 mm |
23 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
24 | 125 mm |
25 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
26 | (i)Single socketed pipes. |
27 | 110 mm diameter |
28 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
29 | Single tee with door |
30 | 110x110x110 mm |
31 | Bend 87.5° |
32 | 110 mm bend |
33 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
34 | 110 mm |
35 | 12 mm cement plaster of mix : |
36 | 1:6 (1 cement: 6 fine sand) |
37 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
38 | 1:6 (1 cement: 6 fine sand) |
39 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : |
40 | 1:4 (1 cement: 4 fine sand) |
41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
42 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
43 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
44 | Two coats. |
45 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
46 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
47 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial de-silting of manholes and de-chocking of sewer lines. De-chocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth. |
48 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
49 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
50 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
51 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
52 | W.C. pan with ISI marked white solid plastic seat and lid |
53 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
54 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
55 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
56 | Kitchen sink without drain board |
57 | 610x460 mm bowl depth 200 mm. |
58 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
59 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
60 | Semi rigid pipe |
61 | 32 mm dia |
62 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
63 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
64 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
66 | 15 mm nominal outer dia. Pipes. |
67 | 25 mm nominal outer dia .Pipes. |
68 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
69 | 25 to 40 mm nominal bore |
70 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
71 | 25 mm nominal bore |
72 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
73 | 45 cm length |
74 | 15 mm nominal bore |
75 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
76 | 100 mm diameter |
77 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
78 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
79 | 15 mm nominal bore |
80 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
81 | 15 mm nominal bore. |
82 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
83 | 15mm nominal bore |
84 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
85 | Supplying and fixing C.I. cover without frame for manholes : |
86 | 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. |
87 | P/F reqquired CPVC FBT/MBT fittings of press to fit design of sealing gasket of EPDM mateial of required dia as per direction of E.I.C. |
88 | (a) 25mm dia n/b |
89 | P/F reqquired CPVC FBT/MBT fittings of press to fit design of sealing gasket of EPDM mateial of required dia as per direction of E.I.C. |
90 | (a) 15mm |
91 | Cleaning of floor with Acid(Harpic or equivqlent) , brush etc including shifting of materials to another places in same campus as desired and broken glass lying on whole floor & encroching suface wiring except switch board all comlete & disposed to dumping ground as per direction of E.I.C.( only area of floor to be measured) |
92 | Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. Chlorination of RCC internal surface by liquid chlorine etc. as per direction of Engineer-in-Charge. |
93 | Cleaning of roof by dumping uwanted rubbish, growing tree etc and wash out whole roof as per direction of E.I.C. |
94 | Cleaning of septic tank by mechanical means and disposal of liquid/semi liquid/solid extract beyond municipal limits and flushing with water lead up to 5.00 KM etc. all complete as per direction of E.I.C.( Item includes removing super netan liquid and digested sludge with help of municipal approved vehicle and disposal the same beyond municipal limits) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy