| 1 | 3.1 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-incharge.3.1.1 In cement mortar |
| 2 | 3.4 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area beyond 3 sq. metres |
| 3 | 3.6 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 4 | Carriage ofMaterials bymechanical transport including loading, unloading and stacking ::Sand, bazri,ballast, kankar |
| 5 | bricks |
| 6 | Earth work in excavation in foundation, trenches etc. includingdressing of sides and ramming of bottoms, including getting out theexcavated material, refilling after laying pipe/ foundation anddisposal of surplus excavated material at a lead upto 50m suitablesite as per direction of Engineer for following depths, below naturalground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt,clay, black cotton soil, kankar, etc.Depth upto 1.5 m |
| 7 | Random rubble dry stone Kharanja (soling) under floor. |
| 8 | Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 9 | Providing and laying damp-proof course with cement concrete grade M-15 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification 50mm thick. |
| 10 | Brick work with FPS bricks of class designation 75 in superstructureabove plinth level upto two stories in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand) |
| 12 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete |
| 13 | Distempering with dry distemper of approved brand andmanufacture (two or more coats) and of required shade on newwork, over and including priming coat of whiting to give an evenshade. |
| 14 | Providing and fixing 1st quality MAT finished ceramic tile size300x300mm confirming to IS : 13755 and IS : 15622 colour such aswhite, grey, ivory, fume red brown, light green, light blue and otherlight shades in floors, steps, pillars etc. laid on a bed of neat cementslurry finished with flush pointing in the white cement mixed withpigment to match the shade of the tile complete (including the costof cement mortar bed 1:4). |
| 15 | Stone slab roofing on ground floor with fine grained stone slab90mm average thickness from approved quarry including filling ofjoints slab in cement sand mortar 1:4 with ceiling pointing in cementsand mortar 1 : 3 complete as per specification for span: Above 3.00 metre and up to 3.30 metre |
| 16 | Structural steel work in single section fixed with or withoutconnecting plate including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete. |
| 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 |
| 18 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel :1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 19 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures completeincluding cutting and making good the walls and floors whereverrequired : White Vitreous china Orissa pattern W.C. pan of size 580x440mmwith integral type foot rests. |
| 20 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps,32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making goodthe walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 21 | P.T.M.T. Soap Dish/Holder 138x102x75mm |
| 22 | Flushing Cistern P.V.C. 10 lts capacity (low level) (White) (withfittings, accessories and flush pipe) |
| 23 | Providing and fixing C.P. brass long body bib cock of approvedquality conforming to IS standards and weighing not less than 690gms 15 mm nominal bore |
| 24 | Providing and placing on terrace (at all floor levels) polyethylenewater storage tank ISI : 12701 marked with cover and suitablelocking arrangement and making necessary holes for inlet, outletand overflow pipes but without fittings and the base support for tank |
| 25 | Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in positionand applying a priming coat of approved steel primer all complete: |
| 26 | Providing and laying in position specified grade of reinforced cementconcrete excluding the cost of centring, shuttering, finishing andreinforcement - All work upto plinth level :1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 27 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel :1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 28 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.@80 kg /cum |
| 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including allCPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and testing of joints complete as perdirection of Engineer in Charge.Internal work - Exposed on wall 25 mm nominal outer dia .Pipes. |
| 30 | Providing and fixing 1mm thick M.S. sheet door with frame of40x40x6mm angle iron and 3mm M.S. gusset plates at the junctionsand corners, all necessary fittings complete, including applying apriming coat of approved steel primerUsing M.S. angels 40x40x6 mm for diagonal braces. |
| 31 | Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators side /top /centre hung with beading and allmembers such as F7D, F4B, K11 B and K12 B etc. complete ofstandard rolled steel sections, joints mitred and flash butt weldedand sash bars tenoned and rivetted with 15x3mm lugs, 10cm long,embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominalsize) or with wooden plugs and screws or rawl plugs and screws orwith fixing clips or with bolts and nuts as required, includingproviding and fixing of hinges, pivots, float glass panes with glazingclips and special metal sash putty of approved make and a primingcoat of approved steel primer excluding the cost of metal beadingand other fittings except necessary hinges or pivots complete as perapproved design. |
| 32 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to thealuminium window by Aluminium beading 20x3mm with suitablescrews at not exceeding 150mm distance at all heights with all leadand lift with scaffolding. |
| 33 | Providing and fixing M.S. round or square bars with M.S. flats atrequired spacing in wooden frames of windows and clerestorywindows. |
| 34 | Earth work in excavation in foundation, trenches etc. includingdressing of sides and ramming of bottoms, including getting out theexcavated material, refilling after laying pipe/ foundation anddisposal of surplus excavated material at a lead upto 50m suitablesite as per direction of Engineer for following depths, below naturalground / Road top level Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.1.1 |
| 35 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size). |
| 36 | Brick work with FPS bricks of class designation 75 in superstructureabove plinth level upto two stories in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 37 | Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand) |
| 38 | Providing and laying in position specified grade of reinforced cementconcrete excluding the cost of centring, shuttering, finishing andreinforcement - All work upto plinth level : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 39 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.@80 kg /cum |
| 40 | Providing, laying and jointing glazed stoneware pipes grade ‘A’ withstiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1fine sand) including testing of joints etc. complete : 100 mm diameter |
| 41 | C.C.I.(spun) socketed soil, waste and vent pipe 1.80 metreslong:100mm dia conforming to I.S. 3989 |
| 42 | Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12mm thick. |
| 43 | Electrification cost ( 7%) |