Tender For Acoustics Treatment Of Hall B And Other Misc. Works At Officer Club Singrauli Ncl Hq., singrauli-Madhya Pradesh

Northern Coalfields Limited-NCL has published Tender For Acoustics Treatment Of Hall B And Other Misc. Works At Officer Club Singrauli Ncl Hq.. Submission Date for this Tender is 21-04-2023. Acoustical Work Tenders in singrauli Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37065259
Corrigendum : Tender For Acoustics Treatment Of Hall B And Other Misc. Works At Officer Club Singrauli Ncl Hq.
Open Tender
Indian
Madhya Pradesh
singrauli
21-04-2023

Tender Details

Acoustics Treatment Of Hall B And Other Misc. Works At Officer Club Singrauli Ncl Hq.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Apr-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-04-2023

Key Value

Document Fees
Refer document
EMD
INR 98900.0 /-
Tender Value
INR 79.07 Lakhs /-

BOQ Items

Name of Work: Acoustics treatment of Hall B and other misc. works at Officer"s Club Singrauli NCL HQ.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
2All kinds of soil
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
41:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
51:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
6Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
7Two or more coats on new work
8French spirit polishing :
9Two or more coats on new works including a coat of wood filler
10Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
11Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
12Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
13Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
14One coat
15Two coats
16Finishing walls with Acrylic Smooth exterior paint of required shade:
17Old work (One or more coat applied @ 0.90 ltr/10 sqm).
18Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge.
19Pre-laminated particle board with decorative lamination on both sides
20Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the "W" profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610 mm C/C with fully threaded self- tapping dry wall screws. Board is fixed to the "W" profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish.
21Gypsum board conforming to IS: 2095 Part -1.
2212.5 mm thick
23Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
2412.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
25Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
263 mm thick
27Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.
2825 mm thick
29Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with :
30Decorative veneer facings of approved manufacture
31Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :
322nd class teak wood
3350x12 mm
34Providing 50x50x50mm 2ndclass teak wood plugsincluding cuttingbrick work and fixing in cement mortar 1:3 (1 cement : 3 fine sand) and making good the walls etc.
35Providingandfixinginwallliningflatpressedthreelayer(mediumdensity)particle boardorgradedwood Pre-laminatedone side decorative laminationand otherside balancinglaminationGradeI,TypeII,IS:12823marked,includingprimingcoaton unexposed surface, with necessary fixing arrangement and screws etc. complete :
3612 mm thick
3718 mm thick
38Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
39For thickness of tiles 10 mm to 25 mm
40For thickness of tiles above 25 mm and up to 40 mm
41Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
42G.S. Sheet
43Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
4440 mm thick with 20 mm nominal size stone aggregate
45Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :
46Dark shade pigment using ordinary cement
47Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
48Size of Tile 600x600 mm
49Size of Tile 800x800 mm
50Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.
51Size of Tile 500x500 mm
52Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
531.0 mm thick
54Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.
55Demolishing cement concrete manually/by mechanical means including disposal of material within 50m lead as per direction of Engineer-in-charge
56Nominal concrete 1:3:6 or richer mix (i.e equivalent design mix)
57Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid for separately).12mm thick commercial ply conforming to IS : 1328 BWR type
58Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
59Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:G.S. Sheet
60Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundationtrenchesordrains(not exceeding1.5 min widthor 10sqm onplan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
61All kinds of soil.
62Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
63Providingandlayinginpositionspecifiedgradeofreinforcedcementconcrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
641:1.5:3(1cement:1.5coarsesand(zone-III):3gradedstoneaggregate20mm nominal size).
65Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts andstrutsetc.aboveplinthleveluptofloorfivelevel,excludingcostofcentering, shuttering, finishing and reinforcement :
661:1.5:3(1cement:1.5coarsesand(zone-III) :3gradedstoneaggregate20mm nominal size).
67Centering and shuttering including strutting, propping etc. and removal of form for:
68Foundations, footings, bases of columns, etc. for mass concrete
69Columns, Pillars, Piers, Abutments, Posts and Struts
70Lintels, beams, plinth beams, girders, bressumers and cantilevers
71Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like
72Weather shade, Chajjas, corbels etc., including edges
73Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cementconcreteworkinstringcourses,bands,copings,bedplates,anchorblocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3graded stone aggregate 20 mm nominal size).
74Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto plinth level.
75Cold twisted bars
76Brickwork with Non Modular FLAG Bricks confirming to IS 12894 , class designation 7.5 average compressive strength etc. Complete in all respect in foundation and plinth.
77In Cement mortar 1:6 ( 1 Cement : 6 Coarse sand )
78Brickwork with Non Modular FLAG Bricks confirming to IS 12894 , class designation 7.5 average compressive strength etc. Complete in superstructure above plinth level upto floor v level.
79In Cement mortar 1:6 ( 1 Cement : 6 Coarse sand )
80Brickwork with Non Modular FLAG Bricks confirming to IS 12894 , class designation 7.5 average compressive strength etc. Complete in superstructure above plinth level upto floor v level.
81In Cement mortar 1:4 ( 1 Cement : 4 Coarse sand )
8212 mm cement plaster of mix :
831:4 (1 cement: 4 fine sand)
8412 mm cement plaster of mix :
851:6 (1 cement: 6 fine sand)
86Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
8740 mm thick with 20 mm nominal size stone aggregate
88Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
89Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
90Hot finished welded type tubes
91Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
92Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
93Supplyingandfillinginplinthwithsandunderfloors,includingwatering,ramming, consolidating and dressing complete.
94Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
9525 mm thick
96Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rodswith galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
97GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
9812.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
99Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge.
100Providingandfixing18mmthickgangsawcut,mirrorpolished,premouldedand prepolished,machinecut forkitchenplatforms,vanitycounters,windowsills,facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixedwithmatchingpigment,epoxytouchups,includingrubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
101Granite of any colour and shade
102Area of slab upto 0.50 sqm
103Providingedgemouldingto18mmthickmarblestonecounters,Vanitiesetc.includingmachinepolishingtoedgetogivehighglossfinishetc.completeasper design approved by Engineer-in-Charge.
104Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
105Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in- charge.
106Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduitwith modular switch, suitable GI box & earthing the point with 1.5Sq.mm FRLS PVC insulated copper conductor single core etc. as required & as per direction of EIC.
107Supplying and fixing modular type 5/6 amps switch & socket on the existing/ seperate modular plate / switch box/ cover including connections etc.complete in all respect as required & as per direction of EIC..
108Supply of materials and Concealed / surface wiring ( as per requirement)for power point with 2.5 Sq.mm PVC insulated, 1.1KV grade copper cable/ wire (Phase & Neutral) including 16/6 Amp modular switch socket /combined, MS board / GI box /teak wood board with bakelitesheet on top as per requirement , with 1.5 SqmmPVC insulated cable/wire for earth wire which shall be run with wiring inside the PVC conduit/ casing caping. etc. complete in all respect.& direction of EIC.All materials Should be as per IS Specification
109Supply of materials and Concealed/surface circuit wiring (as per site requirement) with2.5 Sqmm PVC insulated, 1.1KV grade copper wire/ cableand wiring the same in suitable size of PVC conduit/ casing caping, inspection boxes including1.0 Sq.mm copper cable/ wire for earth wire etccomplete in all respect as per requirement & direction of EIC for light CKT wiring. All materials Should be as per IS Specification
110Supply of materials and Concealed/surface circuit wiring (as per site requirement) with4.0Sqmm PVC insulated, 1.1KV grade copper wire/ cableand wiring the same in suitable size of PVC conduit/ casing caping, inspection boxes including1.5 Sq.mm copper cable/ wire for earth wire etccomplete in all respect as per requirement & direction of EIC for power CKT wiring. All materials Should be as per IS Specification
111Supplying and fixing 20 A rating, 240/415 V, 10 KA, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioningetc.complete in all respect as required & as per direction of EIC..as required.
112Supplying and fixing 32 A rating, 240/415 V, 10 KA, miniature circuit breaker suitable for inductive load of double pole in the existing MCB DP complete with connections, testing and commissioningetc.complete in all respect as required & as per direction of EIC.
113Supplying and fixing 63Amp rating, four pole, 415 volts, isolator in the existing MCB DB complete with connection, testing and commissioningetc.complete in all respect as required & as per direction of EIC.
114Supplying and fixing 4way, double door, horizontal type, three pole & neutral , sheet steel, MCB distribution board,415Volt on surface/recessed complete with tinned copper bus bar, neutral bus bar earth bar din bar interconnections powder painted including earthing, without MCB/RCCB/Isolatoretc.complete in all respect as required & as per direction of EIC.
115Supply & laying of 4x6 sq.mm. heavy duty electric cable with copper conductor, 1.1KV Grade to IS:7098 part-1 for PVC insulated, unarmoured cable for controlling oflight & power circuit from mainto sub-main distribution board.Laying of cable shall be done as per requiement at siteetc.complete in all respect as required & as per direction of EIC..as required.
116Supplying and fixing of 200Amp, 36KA four pole MCCB, 415Volt, 50Hz AC with thermomagnatic release and terminal spreaders in cubical panel board including drilling holes in cubicle panel making of connection etc. complete in all respect as per site requirement & as per direction of EIC.
117Supply & fixing of wall mounting fan size of 400mm, bracket mounted , 230V 50Hz, AC with IS specificationetc.complete in all respect as required & as per direction of EIC.
118Supply & fixing of exhaust fan size of blade 300 mm sweep ,capacitor type ,230V, 50Hz AC ( non noisable/ magnetic ) , complete in all respectwith IS specification as required & as per direction of EIC.
119Supply & fixing of18 Watt LED panel lightfitting for indoor light purpose suitable for , 230 V, 50 Hz , AC complete in all respectwith IS specification of any standard make including connection worketc.complete in all respect as required & as per direction of EIC.
120Supply & fixing of 20 Watt LED T/L 4 feet fitting for indoor light purpose suitable for , 230 V, 50 Hz , AC complete with suitable frame & rod as required at the wall & ceiling of the room etc.complete in all respect as per site requirement & direction of EIC. All materials Should be as per IS Specification of any standard make.
121Supply & fixing of 120 watt LED street light fitting, 230 V,50 Hz , AC and as per IS specification of any standard make etc.complete with connection work etc . complete in all respect as per site requirement & direction of EIC .
122Earthing with G.I. earth pipe 3 metre long, 40 mm dia including excavation of earth (all type of soil), making of earth pit with all othersrequired materials / accessories and back filling of earth providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and saltetc.complete in all respect as per IS specification as required & as per direction of EIC.
123Supply & fixing of 10 watt LED decorative wall light (No.of souce 2/3/4 as per site requirement) fitting , 230 V,50 Hz , AC with IS specification of any standard make etc.complete includingconnection work etc . complete in all respect as per site requirement & direction of EIC .
124Supply , installation, testing & commissioning of 2tons Invertor split Air conditioner, BEE star rating, 5star rating, green AC,230 V,50 Hz , AC with IS specification of any standard make including installation, connection work etc . complete in all respect as per site requirement & direction of EIC .
125Supply & fixing of 100 watt LED luminaire for high bay lighting, round shape as per site requirement,230 V,50 Hz , AC with IS specification of any standard makeincludingconnection work etc . complete in all respect as per site requirement & direction of EIC .
126Supply & fixing of 6Amp, 230Volt AC, one way modular switch with IS specification of any standard make.
127Supply & fixing of 6Amp, 230Volt AC, 5pin modular socket with IS specification of any standard make.
128Supply & fixing of 16Amp, 230Volt AC, one way modular switch with IS specification of any standard make.
129Supply & fixing of 16Amp, 230Volt AC, 5pin modular socket with IS specification of any standard make.
130Supply & fixing of 3modules modular GI boxalongwith modular base & cover plate as per IS specification for modular switches & sockets in recess etc.complete in all respect including connection work as per site requirement & direction of EIC .
131Supply & fixing of 8modules modular GI boxalongwith modular base & cover plate as per IS specification for modular switches & sockets in recess etc.complete in all respect including connection work as per site requirement & direction of EIC.
132Supply & fixing of 12modules modular GI boxalongwith modular base & cover plate as per IS specification for modular switches & sockets in recess etc.complete in all respect including connection work as per site requirement & direction of EIC .
133Providing & erection of 3meter hight black painted galvanized decorative designer poles in diffferent section, top 60mm dia, bottom 140mm dia with gold colour painted ornamental cast aluminium ring having lockable, weather proof, flush door, junction box in bottomsection, base plate dia 290mm having 4holes of 22mm dia complete erected in an approved manner on foundation. Suitable size & type of foundation bolts 4nos. x 16mmx 450mm "J" type.
134Supply, fixing & testing of approved make globe type poly corbonate post top lantern size of 300mm, consisting of cast aluminium spigot complete with all accessories, lamp holder,15watt LED lamp, 230Volt AC including fixing on 3mtrs hight black decorative designer pole with connection work etc complete in all respect as per site requirement & as per direction of EIC.
135Supply, fixing & testing of approved make globe type poly corbonate post top lantern size of 300mm, consisting of cast aluminium spigot complete with all accessories, lamp holder,15watt, 230V LED lamp including fixing on gate pillars/ GI pipe pole with connection work etc complete in all respect as per site requirement & as per direction of EIC.
136Supply, fixing of approved make accepted standard sheet steelenclosure/ distribution box,four pole, dust protected duly powder coated paint , neutral bar, fixing & connection of MCB of rating 6A single poleetc complete in all respect as per site requirement & direction of EIC.
137Supply of 3x2.50 sq.mm. PVC insulated, unarmoured, power cable cable with copper conductor, 1.1KV Grade as per IS specificationcable for controlling oflight fitting & power circuit from distribution board/ box .Laying of cable shall be done as per requiement at siteetc.complete in all respect as required & as per direction of EIC..as required.
138Supply of 4x6 sq.mm. heavy duty electric cable with copper conductor, 1.1KV Grade as per IS specification PVC insulated, armoured cable for controlling oflight & power circuit from mainto sub-main distribution board.Laying of cable shall be done as per requiement at siteetc.complete in all respect as required & as per direction of EIC.
139Laying of PVC armoured power cable of different size 1.1KV grade direct in ground including excavation, sand cushining protective covering and refilling the trench etc. complete in all respect as per site requirement & direction of EIC
140Total impact of GST for the purpose of CTC
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail