Tender For Procurement Of Rtd And Thermocouples For Stage-I And Ii, Ctpp, Chhabra, chhabra-Rajasthan

Rajasthan Rajya Vidyut Utpadan Nigam Limited-RVUNL has published Tender For Procurement Of Rtd And Thermocouples For Stage-I And Ii, Ctpp, Chhabra. Submission Date for this Tender is 01-06-2023. Thermocouples Tenders in chhabra Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

37061061
Corrigendum : Tender For Procurement Of Rtd And Thermocouples For Stage-I And Ii, Ctpp, Chhabra
Open Tender
Indian
Rajasthan
chhabra
01-06-2023

Tender Details

Procurement Of Rtd And Thermocouples For Stage-I And Ii, Ctpp, Chhabra , J – Type, Duplex Ungrounded Thermocouplewith Thermowell(Specification As Per Annexure-1) , Thermowell For Above Thermocouple At Sr. No. 01 ( Specification As Per Annexure-1 ) , K – Type Duplex Ungrounded Thermocouple With Thermowell For Ms Temp At Sh Outlet. (Specification As Per Annexure-2) , K – Type Duplex Ungrounded Thermocouple With Thermowell For Aph Hot/Cold End Temp. (Specification As Per Annexure-3) , Thermowell For Above Thermocouple At Sr. No. 4 (Specification As Per Annexure-3) , K – Type Duplex Ungrounded Thermocouple With Thermowell Forcrh Stm Tmp Bfr Desh-L, Stm Tmp Lphs IL. (Specification As Per Annexure-4) , Thermowell For Above Thermocouple At Sr. No. 6 (Specification As Per Annexure-4) , R – Type Duplex Ungrounded Thermocouple With Thermowell For Fg System Temperature Measurement At Psh OL.(Specification As Per Annexure-5) , Pt-100X2, Duplex 3 Wire Rtd With Thermowell For Gsc To Lp Ft Temp. (Specification As Per Annexure-6) , Thermowell For Above Rtd At Sr. No. 9 (Specification As Per Annexure-6) , Pt-100X2, Duplex 3 Wirertd With Thermowell For Drn Cooler To Lp Flash Tank Drn Tmp (Specification As Per Annexure-7) , Thermowell For Above Rtd At Sr. No. 11 (Specification As Per Annexure-7) , Pt-100X2, Duplex 3 Wirertd With Thermowell For Aph Guide Bearing Temp (Specification As Per Annexure- 8) , Pt 100 Duplex 4 Wire Mill Bearingrtd (Specification As Per Annexure- 9) , Pt-100X2, Duplex 3 Wire Head Less Rtd For Fd, Pa, Fan Brg Temp.(Specification As Per Annexure- 10) , Pt100x2 Duplex 3 Wire Headless Rtd For Bfp Bp &Thrust Bearing Temp Rtd. (Specification As Per Annexure- 11) , K – Type Duplex Ungrounded Thermocouple With Thermowell For Fg Temp. At Fsh O/L (Specification As Per Annexure- 12) , K – Type Duplex Ungrounded Thermocouple With Thermowell For Fg Temp. At Ltsh O/L (Specification As Per Annexure- 13) , R – Typeduplex Ungrounded Thermocoupleforfg Systemtemperature Measurement At Rh OL. (Specification As Per Annexure- 14) , K – Type Duplex Ungrounded Thermocouple With Thermowell For Fire Protection Temp. (Specification As Per Annexure- 15) , Thermowell For Fire Protection Temp. (Specification As Per Annexure- 16) , Cable For Thurst Bearing Rtd: Duplex 3 Wire, 5 Mtr.Long Fep/Fep Insulated Ss Braided Flexible Cable With Sealpot. Temp Range: 0-150 °C (Specification As Per Annexure- 17) , Thermocouple For Ip Inner Casing (Specification As Per Annexure- A) , Thermocouple Forhp Exhaust (Specification As Per Annexure- B) , Thermocouple For Lp Casing (Specification As Per Annexure- C)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Apr-2023 Corrigendum I Date 03-05-2023
2 03-May-2023 Corrigendum II Date 11-05-2023
3 11-May-2023 Corrigendum III Date 24-05-2023
4 24-May-2023 Corrigendum IV Date 01-06-2023

Key Value

Document Fees
INR 590 /-
EMD
INR 48000.0 /-
Tender Value
INR 24 Lakhs /-

BOQ Items

Name of Work: Procurement of RTD and Thermocouples for Stage-I &II, CTPP, Chhabra
Sl. No. Item Description
1J – TYPE, DUPLEX UNGROUNDED THERMOCOUPLEWITH THERMOWELL(SPECIFICATION AS PER ANNEXURE-1)
2THERMOWELL FOR ABOVE THERMOCOUPLE AT SR. NO. 01 ( SPECIFICATION AS PER ANNEXURE-1 )
3K – TYPE DUPLEX UNGROUNDED THERMOCOUPLE WITH THERMOWELL FOR MS TEMP AT SH OUTLET. (SPECIFICATION AS PER ANNEXURE-2)
4K – TYPE DUPLEX UNGROUNDED THERMOCOUPLE WITH THERMOWELL FOR APH HOT/COLD END TEMP. (SPECIFICATION AS PER ANNEXURE-3)
5THERMOWELL FOR ABOVE THERMOCOUPLE AT SR. NO. 4 (SPECIFICATION AS PER ANNEXURE-3)
6K – TYPE DUPLEX UNGROUNDED THERMOCOUPLE WITH THERMOWELL FORCRH STM TMP BFR DESH-L, STM TMP LPHS I\L. (SPECIFICATION AS PER ANNEXURE-4)
7THERMOWELL FOR ABOVE THERMOCOUPLE AT SR. NO. 6 (SPECIFICATION AS PER ANNEXURE-4)
8R – TYPE DUPLEX UNGROUNDED THERMOCOUPLE WITH THERMOWELL FOR FG SYSTEM TEMPERATURE MEASUREMENT AT PSH O\L.(SPECIFICATION AS PER ANNEXURE-5)
9PT-100x2, DUPLEX 3 WIRE RTD WITH THERMOWELL FOR GSC TO LP FT TEMP. (SPECIFICATION AS PER ANNEXURE-6)
10THERMOWELL FOR ABOVE RTD AT SR. NO. 9 (SPECIFICATION AS PER ANNEXURE-6)
11PT-100x2, DUPLEX 3 WIRERTD WITH THERMOWELL FOR DRN COOLER TO LP FLASH TANK DRN TMP (SPECIFICATION AS PER ANNEXURE-7)
12THERMOWELL FOR ABOVE RTD AT SR. NO. 11 (SPECIFICATION AS PER ANNEXURE-7)
13PT-100x2, DUPLEX 3 WIRERTD WITH THERMOWELL FOR APH GUIDE BEARING TEMP (SPECIFICATION AS PER ANNEXURE- 8)
14PT 100 DUPLEX 4 WIRE Mill BEARINGRTD (SPECIFICATION AS PER ANNEXURE- 9)
15PT-100x2, DUPLEX 3 WIRE HEAD LESS RTD FOR FD, PA, FAN BRG TEMP.(SPECIFICATION AS PER ANNEXURE- 10)
16PT100X2 DUPLEX 3 WIRE HEADLESS RTD FOR BFP BP &THRUST BEARING TEMP RTD. (SPECIFICATION AS PER ANNEXURE- 11)
17K – TYPE DUPLEX UNGROUNDED THERMOCOUPLE WITH THERMOWELL FOR FG TEMP. AT FSH O/L (SPECIFICATION AS PER ANNEXURE- 12)
18K – TYPE DUPLEX UNGROUNDED THERMOCOUPLE WITH THERMOWELL FOR FG TEMP. AT LTSH O/L (SPECIFICATION AS PER ANNEXURE- 13)
19R – TYPEDUPLEX UNGROUNDED THERMOCOUPLEFORFG SYSTEMTEMPERATURE MEASUREMENT AT RH O\L. (SPECIFICATION AS PER ANNEXURE- 14)
20K – TYPE DUPLEX UNGROUNDED THERMOCOUPLE WITH THERMOWELL FOR FIRE PROTECTION TEMP. (SPECIFICATION AS PER ANNEXURE- 15)
21THERMOWELL FOR FIRE PROTECTION TEMP. (SPECIFICATION AS PER ANNEXURE- 16)
22CABLE FOR THURST BEARING RTD: DUPLEX 3 WIRE, 5 MTR.LONG FEP/FEP INSULATED SS BRAIDED FLEXIBLE CABLE WITH SEALPOT. TEMP RANGE: 0-150 °C (SPECIFICATION AS PER ANNEXURE- 17)
23THERMOCOUPLE FOR IP INNER CASING (SPECIFICATION AS PER ANNEXURE- A)
24THERMOCOUPLE FORHP EXHAUST (SPECIFICATION AS PER ANNEXURE- B)
25THERMOCOUPLE FOR LP CASING (SPECIFICATION AS PER ANNEXURE- C)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail