}

Providing Electricity Supply According To The Prescribed Roster In Gabhana Nagar Panchayat Under The Area Of ​​Electricity Distribution Division - First, Aligarh., aligarh-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited has published Providing Electricity Supply According To The Prescribed Roster In Gabhana Nagar Panchayat Under The Area Of ​​Electricity Distribution Division - First, Aligarh.. Submission Date for this Tender is 05-04-2023. Wall Construction Tenders in aligarh Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37055512
Providing Electricity Supply According To The Prescribed Roster In Gabhana Nagar Panchayat Under The Area Of ​​Electricity Distribution Division - First, Aligarh.
Open Tender
NCB
Uttar Pradesh
Aligarh
05-04-2023

Tender Details

Providing Electricity Supply According To The Prescribed Roster In Gabhana Nagar Panchayat Under The Area Of ​​Electricity Distribution Division - First, Aligarh.- 1 Pcc Pole 8.5 Mtr. Long 2 Pcc Pole 9.0 Mtr. Long 3 St Pole 11 Mtr. Long 4 Stone Pad 5 Top Channal ( 125X65x2240mm ) With Clamp 6 Dropper Channal ( 100X50x2028mm ) With Clamp 7 T / F Base Angle ( 75X75x6x2028mm ) With Clamp 8 Ms Tee-Off Channal With Clamp And B&N 9 Holding Clamp With N&B 10 V-Type Steel Cross Arm With Clamp 11 11 Kv Pin Insulator With Pin Complete 12 11 Kv Disc Insulator With Fitting ( T&C ) 13 F-Bracket For Fitting Top Channal 14 Phase Wire Acsr Weasal Conductor 15 Danger Plate With Clamp N&B 16 Danger Board With Clamp 17 Barbed Wire Gi 18 Earthing Complete 19 Stay Complete With Concreating 20 Concreting Of Pole 21 Concreting Of Stay 22 Cable Abc 3X95+1X70+1X16 Sq.Mm. 23 Cable Abc 3X50+1X35+1X16 Sq.Mm. 24 11 Kv Xlpe Cable 3X185 Sq.Mm. 25 11 Kv Cable Jointing Kit 3X185 Sq.Mm. I / D 26 11 Kv Cable Jointing Kit 3X185 Sq.Mm. O / D 27 Gi Pipe 6 Dia 28 Ms Channel For Holding Of G.I. Pipe On Double Pole 29 160Mm Odpn-4Pe-80 Grade Uv Stabliyed Hdpe 30 Laying Hdpe Pipe 160 Mm Dia 31 Cable Jointing Kit Straigth Through 32 Cable Laying In Hdpe Pipe By Hdd Method. 33 Lt Cable 4X16 Sq.Mm. 34 Eye Hook 35 Piercing Connector 36 11 Kv Fuse Set 37 Gaurding Angle With Clamp 38 Gi Wire 6 Swg ( Main Guard Wire ) 39 Gi Wire 10 Swg For Cross Lacing 40 Distribution Box 3P With Clamp 41 Holding Clamp With N&B For D / P 42 End Clamp 43 11 / 0.4 Kv 400 Kva Transformer 44 11 / 0.4 Kv 250 Kva Transformer 45 11 / 0.4 Kv 100 Kva Transformer 46 Lt Xlpe Cable 1X240 Sq.Mm. 47 Lt Xlpe Cable 1X400 Sq.Mm. 48 Lt Cable 4X16 / 3.5X70 / 35 / 3.5 / 150 / 70 Sq.Mm. 49 Body And Neutral Earthing Of Following L.T. Distribution Transformers Installed By Digging Of Pit Up To Water Level Depth ( Approx. 100’ ) And Then Inserting1-1 / 4 Dia G.I. Pipe Of B Grade, Conforming To The Requirement Of Is Specification And Then Connecting The Top Of The Inserted Pipe And Transformer Body Through Gi Strip Of Size 50X6 Mm With The Help Of Nut And Bolt Or Through Gas Welding, As Per Direction Of Supervising Engineer Including The Cost Of Arrangement Of All Material, Labourer, T&P, Carrier Etc. Required For Proper Completion Of Work. 50 250 Kva Transformer 51 400 Kva Transformer 52 Construction Of Following Transformer Of Plinth Of Size 5’X5x4’ Above Ground Level And One Ft. Below The Ground Level Of 9”. After Excavation Of 4” Earth, Brick Ballast Shall Be Provided And Rammering Will Be Done Properly After That A Retaining Wall Of 9” Width By First Class Brick In Ratio 1:4 Of Cement And Sand Shall Be Made. The Earth Shall Be Filled Up To One Ft. Below The Top Of The Plinth. After This Brick Ballast Shall Be Provided Up To 6” From The Earth Level And Proper Rammering Shall Be Done. One No. Jall Of 12 Mm M.S. Tor Shall Be Fixed In The Hollow Of Plinth And One Ft. Thick Rcc In Ratio Of Cement, Sand And Stone Ballast Shall Be Laid On The Top Of The Plinth. The 12 Mm Thick Plastering Shall Be Done All Around The Plinth In 1:4 Ratio Of Cement And Sand. The Contractor Shall Be Responsible To Complete The Work As Per Direction Of Supervising Engineer. It Including The Cost Of All Material, Labour T&P, Carrier Etc. Required For Proper Completion Of Work. 53 250 Kva Transformer 54 Fabrication & Erection Of Fencing And Construction Of Retaining Wall Aroundfollowing Capacity T / Fthe Complete 11 / 0.4 Kv Substation Shall Be Provided With Two Meter Height Fencing And Retaining Wall Around The Substation. One No. Gate With Proper Locking Arrangement For Entry Of Personnel Shall Also Be Provided. The Fencing Shall Be Made Of 50X25 Mm X10 Swg Rectangular Welded Mesh Of Wire Mesh In Length. Wire Mesh Shall Be Fixed On Panels Made Of 50X50x6 Mm M.S. Angle. The Wire Mesh On Panels Will Be Supported By 25X3 Mm M.S. Flat On All The Bracings Diagonally And 50X6 M.S. Flat Horizontally At The Center Of The Panel. The Panel Will Be Joined By Bolts & Nuts Of Appropriate Size With Each Other And On The Main Support On Corners Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work. The Painting Of Complete Fencing Shall Also Be Done With One Coat Of Red Oxide Primer And Two Coat Of Synthetic Green Paint. For Construction Of Retaining Wall Around The Fencing, Excavation Of Earth Shall Be Done In Foundation In Ordinary Soil Including Disposal Of Surplus Earth At Some Suitable Distance. The Dimension Of Excavation Shall Be 1M Wide, 0.45 M Deep And Suitable Length As Per Wire Mesh. After Excavation Of Earth A Cement Concreted Pad Shall Be Laid In Foundation. Concreting Shall Be Done With Ist Class Brick Ballast, Coarse Sand And Cement In Proportion Of 8:4:1. First Class Brickwork Shall Also Be Done In Foundation And Super Structure In 1:6 Cement And Coarse Sand Including Necessary Cutting And Moulding Of Bricks In Foundation Depth Of Wall 0.30 M, Thickness Of Wall 0.35 M & Superstructure Brick Work Thickness Of Wall 0.23 M & Depths 0.30 M Including Supply Of All Material, Labour, Carrier And T & P Etc. Required For Proper Completion Of Work. 55 250 Kva Transformer 56 400 Kva Transformer 57 Demounting & Carriage Of Following Capacity Transformer Due To Overloaded Including The Work Of Its Loading & Unloading, Dragging Etc. And Also Including The Cost Of Labour And T&P Etc. Required For Proper Completion Of Work. 58 63Kva Transformer 59 100Kva Transformer 60 250Kva Transformer 61 Dismantling And Removal Of Existing Conductor / Cable / Gi Wire From The Various Area Preparing Their Coils And Then Stacking In The Respective Je’S ( Store ) As Per Direction Of Supervising Engineer. It Includes The Work Of Cartage, Cost Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work. 62 St Pole 9.0 Mtr.Long ( Old & Used ) 63 Gi Wire ( Scrap ) 64 Lt Abc Cable ( Damaged )

Key Value

Document Fees
INR 5900 /-
EMD
INR 144000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail