Military Engineer Services-MES has published Tender For Special Repair To Storm Water Drainage Lines At Mo(K), Naval Base, Kochi. Submission Date for this Tender is 04-05-2023. Drainage Tenders in kochi Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Apr-2023 | CORRIGENDUM1 | BOQ | 27-04-2023 |
2 | 27-Apr-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-05-2023 |
Sl. No. | Item Description |
1 | Demolition of precast PCC block masonry/ brick work or stone / boulder masonry including all quions, arches, pillars, etc built in cement mortar or cement lime mortar complete all as specified and directed. |
2 | M&L for RCC M30 (design mix) (with 20mm graded aggregate) in walls,retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses completee all as specified and directed. |
3 | M&L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc with rough finished surfaces of concrete in flat; vertical or to batter completee all as specified and directed. |
4 | Demolition of concrete in ground floors and pavings n exc. 15cm thick (below of above ground level) completee all as specified and directed. |
5 | M&L for cement concerete of type D2 1:4:8 (40mm graded aggregate) in surface channels and drains completee all as specified and directed. |
6 | Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth (without using extra lime or cement) completee all as specified and directed. |
7 | S&F framed work such as grills, gratings, etc with ends of bars shouldered & or riveted, or forgedinto spikes, framed guard bars etc & similar work conforming to Fe.290 Gde E-165 completee all as specified and directed. |
8 | M&L for preparation of new steel surfaces for any description & applying two coats of synthetic enamel paint over a coat of redoxide primer completee all as specified and directed. |
9 | M&L for precast cement concrete of type B1 1:2:4 (20 mm aggreagate) for cover slabs set in CM 1:4 completee all as specified and directed. |
10 | Mild steel barsTMT6mm to 8 mm diacut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookings ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips completee all as specified and directed. |
11 | Mild steel barsTMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookings ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips completee all as specified and directed. |
12 | Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation of pole and laying of underground electric cable in soft/loose soil completee all as specified and directed. |
13 | Returning filling including spreading levelling watering and well ramming in layers not exc 25cm completee all as specified and directed. |
14 | Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point completee all as specified and directed. |
15 | supply and spread river sand for cushioning and covering of UG cables in treanches Note: Punned thickness only be measured and paid. |
16 | S&Fun reinforced precast concrete cable cover class LV type I as per IS 5820 with flat size 250X150X40mm laid dry in trenches over under ground cables complete all as specified and as directed. |
17 | Cutting existing bituminous carpet road/PCC hard standing upto a depth of 30cm for laying of UG cable/GI pipe and making good the disturbed surfaces to match with the existing complete all as specified and as directed. |
18 | Supply and lay in replacement UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated screened PVC bedded steel strip or wire armoured electric power cable (Heavy duty) 1100V grade with stranded aluminium conductor of size 3.5core 50Sqmm with suitable cable gland complete all as specified and as directed. |
19 | All as per item No. 18 above but for 3.5core 35 Sqmm size complete all as specified and as directed. |
20 | All as per item No. 18 above but for 4core 16 Sqmm size complete all as specified and as directed. |
21 | All as per item No. 18 above but for 2core 10 Sqmm size complete all as specified and as directed. |
22 | S&F cable joining kit for straight through heat shrinkable type joint with jointing material and all connected accessories for XLPE armoured conductor cable 1100V grade of size 3.5core 50 Sqmm including taking down of old one all as specified and as directed. |
23 | All as per item No. 22 above but for 3.5 core 35 Sqmm complete all as specified and as directed. |
24 | All as per item No. 22 above but for 4 core 16 Sqmm complete all as specified and as directed. |
25 | Labour for removing existing LT UG cable of any size by excavating and removal of old bricks and making the cable for relaying and kept the old bricks for relaying completee all as specified and directed. |
26 | Relaying of old bricks for cable protection obtained completee all as specified and directed. |
27 | Supply and lay in trenches/fixed on walls/poles GI tubing light grade with all fittings of 50mm dia including taking down old unserviceable GI tubing completee all as specified and directed. |
28 | Shifting of LT panel/feder pillar box from the existing site to decided site after disconnecting the LT incoming and outgoing cable and refixing the same after shifting the panel and connecting the incoming and outgoing cable including necessary PCC work complete all as specified and as directed. |