| 1 | Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil complete all as specified and as directed. |
| 2 | Excavation in trenches n.exc. 1.5 m wide and exc. 1.5 m and n. exc. 3.0 m in depth for foundation or manholes etc., and area n.exc. 10 Sq.m on plan and getting out in hard/dense soil complete all as specified and as directed. |
| 3 | Returning, filling in with approved soil obtained from excavation including spreading levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.. |
| 4 | Removing the excavated soil to a distanceexc 250.0 m and n.exc 500 .0m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.. |
| 5 | Demolition and breaking up drain pipes(salt glazed ware,AC or reinforced concrete) set in cement mortar including concrete bedding and haunching (if necessary) complete all as specified and as directed. for 100mm dia pipe complete all as specified and as directed. . |
| 6 | Description all as per item no 5 above but 150 mm dia pipe. |
| 7 | Description all as per item no 5 above but 200 mm dia pipe. |
| 8 | M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 for 100mm dia pipe complete all as specified and as directed. |
| 9 | M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2150mm dia drain pipecomplete all as specified and as directed. |
| 10 | M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 200 mm dia drain pipecomplete all as specified and as directed. |
| 11 | M&L for SWG drain pipe grade \"A\" of100 mm internal dia laid in trenches and jointedin cement mortar 1:1 complete all as specified and as directed |
| 12 | M&L for SWG drain pipe grade \"A\" of150 mm internal dia laid in trenches and jointedin cement mortar 1:1 complete all as specified and as directed |
| 13 | M&L for SWG drain pipe grade \"A\" of200 mm internal dia laid in trenches and jointedin cement mortar 1:1 complete all as specified and as directed |
| 14 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting ou existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100 mm dia SWG pipe complete all as specified and as directed. |
| 15 | Description All as per item no 14 above but 150mm dia. |
| 16 | Description All as per item no 14 above but 200 mm dia. |
| 17 | Cleaning of Sewage line of 100mm bore including manholes, gully traps, grease traps etc. upto 1.5 m deep by removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the line free from all obstacles and testing the flow of sewer line evenly, smoothly by filling water. The cleaning operation will be carried out in suitable lengths by blocking the first and last manholes of sewage line and removing the silt/sludge & other deposits out side of MD land in covered van/trolley, all as specified & directed. |
| 18 | All as per description of serial item No. 17 here-in-before but sewage line of 150 mm bore and depth of sewage line upto 1.50m. |
| 19 | All as per description of serial item No. 17 here-in-before but sewage line of 150 mm bore and depth of sewage line upto 3.00m. |
| 20 | All as per description of serial item No. 17 here-in-before but sewage line of 200 mm bore and depth of sewage line upto 3.00 m. |
| 21 | Cleaning of manholes depth upto 1.5 mtr by removing all silt, sludge, any other materials making clean and flushing with water complete incuding removal of spoils out side MD land and taken out cover slab and reset in the same position after cleaning and testing complete all as specified and as directed. cleaning shall be done either manually or mechanically as required and directed by Engr-in-charge. |
| 22 | All as per description of serial item No. 21 here-in-before but depth exceeding 1.5 m and not exc 3 m deep complete complete all as specified and as directed. |
| 23 | Cleaningof all blockages of Nahani trap/floor trap, bottle trap, gully trap, P or S traps of WCs, 100 mm/75 mm dia CI pipe stacks upto 1st Manhole, CI/SGSW pipe between gully trap & 1st Manhole, CI Tee/Door bends etc to maintain internal sewage system in Md/OTM Accn ofthe area under AGE B/R -IISecunderabadwith and including manual/pressure cleaning pump & flexible rods and other necessary equipments complete all as specified and as directed. by Engr-in-Charge.Note : (i) Contractor or his authorised representative will collect such type of complaints from SFC Centre complaint cell of AGE B/R - II at 9.00 AM on daily basis except sunday /Holiday. No extra payment shall be made on account of collection of complaint. (ii) Complaint must be attended within 24 hours of receipt of complaint else recovery of Rs. 100/-per complaint/ per day will be Charged. |
| 24 | Demolation of Brick or stone masonry built in cement mortar complete all as specified and as directed.. |
| 25 | M/L brick work with Fly Ashbricks built in CM 1:4 straight or curved exceeding 6m mean radius complete all as specified and as directed |
| 26 | S&F in repairs galvanised two strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including scuring tying at crossing with and provision of galvanisd mild steel wire taples or steel pins complete all as specified and as directed |
| 27 | Demolition of reinforced cement concrete of any description and in any position, not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed |
| 28 | M&L Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate ) for manhole cover septic tank covers slabs etc including necessary form work and set in CM (1:4) complete all as specified and as directed.. Note:- Reinforcement will be measured and paid seperatel |
| 29 | S/F MS TMT bars 10 mmdia and over for reinforcement etc, cut to length, bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed. |
| 30 | All as per Sl item No 29 above but 6 to 8 mm dia. |
| 31 | Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in internal and external surfaces of man holes, septic tank, filter bed etc incl removing of debrie complete all as specified and as directed. |
| 32 | Supply only intergral water proofing compound complete all as specified and as directed |
| 33 | M&L for rendering 15mm thick in CM 1:4 with WPC on fair faces of brick/concrete finished even and fair without using extra cement complete all as specified and as directed. (WPC will be meausred and paid separately) |
| 34 | Cleaning and de-sludging of existing septic tanks/ deep manholes up to 3 metre deep including taking out sludge in any form alongwith all other foreign materials by mechanical equipment or manually or by way of any other suitable means including removal of sludge and other foreign materials out side the MD land by any means complete(working in foul condition) complete all as specified and as directed. |
| 35 | All as per item No 34 above but depth exe 3mtr and not exe 6 mtr |
| 36 | S&F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls bore of the pipe 110 mm complete all as specified and as directed.. |
| 37 | S&F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls bore of the pipe 75 mm. complete all as specified and as directed. |
| 38 | S&F PVC(SWR) bends 110 mm dia. |
| 39 | S&F PVC(SWR) junction double,(double T),equal or unequal. 110 mm dia with access door.complete all as specified and as directed. |
| 40 | S&F PVC (SWR) vent cowl 110 mm dia complete complete all as specified and as directed. |
| 41 | S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement in repair complete complete all as specified and as directed. |
| 42 | S&F for PVC (SWR) gully trap of I25/110 mm dia set and jointing wilh solvent cement complete complete all as specified and as directed. |
| 43 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 44 | Dismantling posts/struts (wood, steel or RCC) any section including taking out embedded portion from concrete/brick masonry etc andmaking good disturbed ground incl barbed wire complete all as specified and as directed. . |
| 45 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard or dence soil complete all as specified and as directed.. |
| 46 | M&L for cement concrete in foundation filling and mass concrete type D2 1:4:8 (40mm graded aggregate) complete all as specified and as directed.. |
| 47 | S&F for posts and struts in fencing including embedding in concrete and screwing etc. including securing bolts;cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0. complete all as specified and as directed. |
| 48 | Supply only Chain link MS galvanised fencing, of any size or type. complete all as specified and as directed. |
| 49 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire.complete all as specified and as directed. |
| 50 | M&L 5 to 10mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed. |
| 51 | S&F for mild steel TMT bars 10mm dia and over, cut to lengthcomplete all as specified and as directed. |
| 52 | Demolition of stone slabs of any description or thickness in floors, aprons, etc laid, bedded and pointed in any mortar |
| 53 | Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15cm thickness (Below or above Ground level) complete all as directed. |
| 54 | M & L 75mm thickPCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 55 | M & L 75mm thickPCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in base/flooringp/plinth protection finishing surface even and smooth without using extra cement complete all as specified and as directed. |
| 56 | M&L Chequered cement concrete tiles of size 30 cmx 30 cmx 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment and including 20mm thick screed bed with cement mortar 1:6complete all as specified & directed. |
| 57 | M & L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS 15658-2006 of 60 mm thickness, M-35 Gradeover 40 mm thick sand cushion Complete all as directed by Engineer-in-charge Make :- Ultra or Classic. |
| 58 | M&L for PCC type B1 1:2:4 (20mm graded aggregate) as in copings, plinth courses, bed plates, kerbs incl necessary formwork etc complete all as specified and as directed.. |
| 59 | M/L rendering 15mm thick in M 1:4 on fair faces of brick or concrete surfaces finished even and fair complete complete all as specified and as directed. |
| 60 | M&L for Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and as directed.. |
| 61 | M&L Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete. |
| 62 | M&L for Brick work with sub class \"B\" bricks straight or curved on plan exc 6M mean radius built in CM 1:6 as in manhole etc. complete all as specified and directed |
| 63 | All as per Sl item No 62 above but except bricks including removing the mortar & cleaning complete all as specified and directed |
| 64 | All as per SL Item No 62 but half brick work in CM 1:4 |
| 65 | Mechanically pumping out sewage water from Septic tanks/sump well where required and as directed with taking precautionary measurer including tools & plants as required and removing to place out side MD land from the site complete(working in foul condition) all as specified and directed. |
| 66 | Removal of filter media including sludge as deposited by excavating in foul position from filter beds etc any depth or width all as specified and getting out. |
| 67 | Selecting stone aggregate as filter media suitable for loose filling back in to filter beds, soak pits etc from the filter media obtained vide item No 66 after drying complete all as specified. |
| 68 | Cleaning of shurbs /bushes arround the septic tank, filter bed, manholes and along the sewage line complete all as specified and directed. |
| 69 | Supply and loose filling with broken stone aggregate of gauge 40 to 80mm as filter media in filter beds, soak pits etc complete all as specified and directed. |
| 70 | Supply and loose filling with broken stone aggregate of gauge 20mm as filter media in filter beds, soak pits etc complete all as specified and directed. |
| 71 | Dismantling old PVC (SWR) pipes any length any dia all as specified and as directed. |
| 72 | Dismantling old PVC (SWR) bends, junctiosns, T, Vet cowl, floor trap etc any any type any dia all as specified and as directed. |
| 73 | S&F PVC(SWR) bends any radius 110 mm bore without access door |
| 74 | S&F PVC(SWR) bends any radius 110 mm bore provided with access door. |
| 75 | S&F PVC(SWR) junction double, (double T), equal or unequal. 110 mm bore . |
| 76 | S & F 75 mm dia PVC (SWR) vent cowl. |
| 77 | M&L 40 mm thickPCC 1:2:4, type B1, using 20 mmgraded stone aggregate as in floors finished even and smooth with using extra cement complete all as specified and as directed. |
| 78 | M&L PCC type B1 1:2:4 (20mm graded stone aggregate) as in lintels upto 1.5 mtr clear span, cills, steps; seismic and other similar bands,copings, bed plates, kerbs etc. including necessary form work. |
| 79 | M&LPCC 1:4:8, type D2, using 40 mm graded stone aggregate as in foundations,filling and mass concrete complete. |
| 80 | M&L 14 to 16 mm thick Granite (of any type) work (table rubbed and polished) over steps, jambs, pillars, window cills, cooking platforms and the like over 15 mm thick cement screed in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including demolition of existing stone all as specified and as directed. |
| 81 | S & F in repairs vitreous china squatting pan \"Orissa pattern\" size 580 x 440mm white with integral foot rest including replacement of \"P\" or \"S\" trap lime concrete bedding and making good floors complete all as specified and directed. |
| 82 | S&F EWC Pedestal pattern WC ,any colourinclEWC seat Cover,10 ltr capacity PVC ,LLFC,32 mm dia PVC flush pipe including CP Toilet holder etc complete all as specified and directed. |
| 83 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the premises complete all as specified and directed. |
| 84 | M & L Non skid ceramic tiles 7 to 8mm thick (square/rectangluar) area of each tile exc 0.06 Sqm but n.exc 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6. complete all as specified and directed. |
| 85 | Preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified. |
| 86 | Preparation of new palstered surfaces of walls and applying three coats of white wash complete all as specified & directed |