Housing Urban and Rular Development Statutory Bodies & Commissions/Committees Closing in 0 days TDR #37051976

Tender For Reconstruction Of Fish Market And Market Complex In Sy No 3 Part1 In Quepem Taluka Fire Fighting Works

Issued by Statutory Bodies & Commissions/Committees · quepem, Goa
Tender Value
47.05 Lakhs
Estimated cost
Bid Submission
21 Apr 2023
0 days left
EMD
94112
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
quepem → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Reconstruction Of Fish Market And Market Complex In Sy No 3 Part1 In Quepem Taluka Fire Fighting Works Reconstruction Of Fish Market And Market Complex In Construction Of Fish Market In Sy No 3 In Quepem Taluka Fire Fighting Works

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Apr-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-Apr-2023

BOQ

Name of Work:Construction of Fish Market and Market complex in Sy.No.3/0 of Quepem Taluka- Fire Fighting Works
Sl. No. Item Description
1Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main single stage pump, of 2400 LPM at 76 m head centrifugal type, 75 HP (55 kW) 3 phase, 415 volt, 50Hz or of suitable HP complete as per specification no. FF-MFP/SSC
2Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 56 m head, 15 HP (11 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP
3Supplying, installing, testing and commissioning with perfect aligning, proper levelling of Diesel Engine operated Fire Pump, of 2280 LPM (Litres/min.) at 76 m head, 30 BHP or suitable BHP with cast iron casing, bronze impellers, EN-8 shaft with bronze shaft sleeves directily coupled to engine complete with MS channel base plate with coupling guard. With suitable Battery, Battery starting kit, Battery charger, Fuel tank, insulated Exhaust chimney and all accessories complete as required.
4Supplying, Installating, Testing and Commissioning of - Flush mounting, free standing/wall mounting Fire Pumps Control Panel (MCC)- Flush front, compartmentalized. Cubical type with folded sheet metal construction (14/16 CRCA steel) & with concealed door hinges, gasket housed in prepared niches. The doors should have concealed latches, open able with special externally inserted tools. Totally enclosed, dust and vermin proof. With separate Chambers for busbar and cables. Provided with painted base mounting frame. Busbars :- Material : Electrolytic Aluminium as per IS 5082, Insulation: Colour coded heat shrinkable PVC Sleeves, Supports : SMC- Painting: - The panel should undergo the seven tank pre-treatment process and then powder coated with siemens grey shed.The panel will operate 1) 75 HP main pump, Auto ON, and 2) 15HP jockey pump, Auto ON & OFF. Incase of power failure this panel has a controller which will give command to start diesel engine pump complete including all wiring & cabling.The control part should have logic such that, in the event of any Hose reel or landing valve is opened, then the pressure in the line drops and the pressure switches installed on the pump manifold give the indication for the jockey pump to start. If more than one landing valves are opened then as sufficient pressure is not built up in the line by jockey pump, hence it will stop and main pump starts. Incase of power failure, diesel pump should start automatically.
5Supplying and installing cast iron foot valve Ball type/Flap type of size 80 mm dia with strainer for negative suction as perspecification No.FF-VL/FV
6Supplying and installing cast iron foot valve Ball type/Flap type of size 100 mm dia with strainer for negative suction as per specification No.FF-VL/FV
7Supplying and installing cast iron foot valve Ball type/Flap type of size 150 mm dia with strainer for negative suction as perspecification No.FF-VL/FV
8Supplying and installing 75/80 mm dia end line strainer for +ve suction as per specification No. FF-VL/ELS
9Supplying and erecting cast iron double flange sluice valve 75/80 mm dia. as per specification No. FF-VL/SV
10Supplying and erecting cast iron double flange sluice valve 100 mm dia. as per specification No. FF-VL/SV
11Supplying and erecting cast iron double flange sluice valve 160 mm dia. as per specification No. FF-VL/SV
12Supplying & erecting cast iron, double flange, butterfly valve of size 75/80 mm dia. Complete as per specification no. FF-VL/BFV.
13Supplying & erecting cast iron, double flange, butterfly valve of size 100 mm dia. Complete as per specification no. FF-VL/BFV.
14Supplying & erecting cast iron, double flange, butterfly valve of size 150 mm dia. Complete as per specification no. FF-VL/BFV.
15Supplying and erecting cast iron double flange NRV of size 75/80 mm dia. complete as per specification No. FF-VL/NRV
16Supplying and erecting cast iron double flange NRV of size 100 mm dia. complete as per specification No. FF-VL/NRV
17Supplying and erecting cast iron double flange NRV of size 150 mm dia. complete as per specification No. FF-VL/NRV
18Supplying & erecting gun metal gate valve of size 25 mm dia. compete as per specification no. FF-VL/GV
19Supplying & erecting gun metal gate valve of size 50 mm dia. Complete as per specification no. FF-VL/GV
20Supplying & Installation of 25 mm Size Ball Valve
21Supplying and erecting Stainless Steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV.
22Supplying & installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT
23Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30 meter long high pressure polypropylene (Polyhose) fitted with necessary accessories complete. As per specification no. FF-FFA/HV
24Supplying fire fighting Reinforced Rubber lined (R.R.L.) Hose pipe, 63 mm dia, 15 m in length, fitted with necessary accessories complete as pre specification no. FF-FFA/RRL
25Supplying & erecting Stainless steel branch pipe of 63 mm dia. Fitted with 20mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ
26Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FBC
27Supplying and erecting fire brigade header (siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
28Supplying and installing Air Vessel of 300 mm dia. 1.5m in height M.S. tank installed inside pump house/ on terrace complete as per specification No. FF-FFA/ACT
29Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
30Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
31Supplying and installing pressure switch with 12/15 mm dia. Isolation valve, G.I. nipple, elbow, etc. complete as per specification no. FF-FFA/PS
32Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade/ SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\"x6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
33Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\"x6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
34Supplying and erecting G.I. pipe above ground of\"C\" class ERW (Electrical Resistance Welding) of size 25 mm dia with necessary fittings complete as per specification no. FF-PP
35Supply and installing G.I. pipe above ground of \"C\" class ERW of size 32 mm dia with necessary fittings as per specification No.FF-PP
36Supply and installing G.I. pipe above ground of \"C\" class ERW of size 40 mm dia with necessary fittings as per specification No.FF-PP
37Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as per specification No. FF-PP
38Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP
39Supplying and erecting G.I. pipe above ground of \"C\" class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP.
40Supplying and erecting G.I. pipe above ground of \"C\" class ERW of size 100 mm dia with necessary fittings complete as per specification no. FF-PP.
41Supplying and erecting G.I.pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as per specification no. FF-PP
42Providing coating of Bitumen Paint & 4mm thick Wrapping for underground 100 mm Ring Main of Fire Fighting System.
43Providing coating of Bitumen Paint & 4mm thick Wrapping for underground 150 mm Ring Main of Fire Fighting System.
44Supplying, installing, testing and commissioning addressable type heat detector complete on box as per specification no. FF-FAS/HD
45Supplying, installing, testing and commissioning addressable type optical type smoke detector complete on box as per specification no. FFFAS/SD
46Supplying, installing, testing and commissioning addressable type manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP
47Supplying, installing, testing and commissioning addressable type hooters with CRCA enclosure complete as per specification no. FF-FAAS/HTR
48Supplying, installing, testing and commissioning addressable type remote response indicators complete as per specification no. FF-FAAS/RRI
49Supplying, installing, testing and commissioning of 01 Loopaddressable type fire alarm control panel (FACP) with standard accessories230V AC, standby battery & battery charger with LCD display,facility to integrated control module, monitor module, detectors like photo-electric detectors & std. facilities complete as per specification no. FF-FAAS/FACP
50Supply, installation, testing & commissioning of isolator module with back box addressable for alarm panel.
51Supplying, erecting, testing and commissioning of 15 mm (½\") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR
52Supplying, erecting testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines ofdia having following features 1) Visual Switch a)100mmActivation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure Mounting 6) Two SPDT ( Single Pole Double Track ) Synchronised Switches 7) Serviceable Without Draining Pipes a)100mm dia
53Supplying, erecting testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines ofdia having following features 1) Visual Switch a)100mmActivation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure Mounting 6) Two SPDT ( Single Pole Double Track ) Synchronised Switches 7) Serviceable Without Draining Pipes b)75/80mm dia
54Supplying, erecting testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines ofdia having following features 1) Visual Switch a)100mmActivation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure Mounting 6) Two SPDT ( Single Pole Double Track ) Synchronised Switches 7) Serviceable Without Draining Pipes c)65mm dia
55Supply, installation, testing and commissioning of Tube trace fire supression System for Main PanelSIZE: 60mx2.5mx0.5m
56Providing round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 guage G.I. sheet with extra handle at bottom duly painted white inside and red outside\" with FIRE Mark, on provided stand/ wall hook.
57Supplying and erecting Wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms Complete.
58Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
59Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 –2006 & CPRI tested having 2 mm thickness upto 3.3 kV
60Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conf. To IS 2878/ 15683 Complete erected withnecessary clamp made front 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
61Supplying and erecting ABC powder type fire extinguisher as per IS : 13849/ 15683 of 1 kg capacity with necessary clamp for erection on wall.
62Supplying and erecting ABC powder type fire extinguisher as per IS : 13849/ 15683 of 6 kg capacity with necessary clamp for erection on wall.
63Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/CU
64Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of followingsize. a) 3 1/2 Core 70 sq.mm
65Supply of3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.- 3 Core 25 sq.mm
66Supply of4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI markconforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. -4 Core 2.5 sq.mm
67Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 1) 3 1/2 x 70 Sq. mm.
68Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. 1) 3x 25 Sq. mm.
69Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. - 4 x 1.5/2.5 Sq. mm.
70Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. - Soily Strata
71Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. - Soily Strata
72Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing masonry open duct,etc.complete as required
73Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of sizeexceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonry open duct,etc.complete as required
74Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required
75Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface, etc. complete as required
76Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required
77Providing & Fixing Self luminating signages of size 100mm x 300mm (4\" x 12\") with necessary accessories all complete, indicatingExits, Fire Extinguishgers, Hose Reel, etc

AI Tender Summary

OUR REF NO 37051976
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.05 Lakhs
LAST DATE 21-04-2023
Authority
Authority Name Goa State Urban Development Agency
Work Description Reconstruction Of Fish Market And Market Complex In Sy No 3 Part1 In Quepem Taluka Fire Fighting Works Reconstruction Of Fish Market And Market Complex In Construction Of Fish Market In Sy No 3 In Quepem Taluka Fire Fighting Works
Basic Detail
Tender No 43/3/GSUDA/Etender/49/23/2750
Bidding Type Tender
Location
City quepem
State Goa
Key Dates
Publish Date 11 Apr 2023
Submission Date 21 Apr 2023
Open Date 22 Apr 2023
Finance
Tender Value 47.05 Lakhs
Tender Fee 3000
EMD 94112
Exemption Not Available
Document List
17a6076f-8646-4e82-8905-2e9e6f66a97f.html
BOQ_8252.xls
Fire.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 11, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 21, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 21, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 22, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

17a6076f-8646-4e82-8905-2e9e6f66a97f.html

xls

BOQ_8252.xls

pdf

Fire.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender