Military Engineer Services-MES has published Tender For Providing Of Transformer And Allied Services And Spl Repair/Replacement Of Lt Cables And Lt Panels At Various Units At Hisar Mil Stn Under Ge Hisar. Submission Date for this Tender is 10-05-2023. Electrification Work Tenders in hisar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

37045475
Corrigendum : Tender For Providing Of Transformer And Allied Services And Spl Repair/Replacement Of Lt Cables And Lt Panels At Various Units At Hisar Mil Stn Under Ge Hisar
Open Tender
Indian
Haryana
hisar
10-05-2023

Tender Details

Providing Of Transformer And Allied Services And Spl Repair / Replacement Of Lt Cables And Lt Panels At Various Units At Hisar Mil Stn Under Ge Hisar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Apr-2023 CWE/HSR-48 OF 2022-23 DATE Date 03-05-2023
2 25-Apr-2023 BOQ AND OTHER AMENDMENT CWE/HSR-48 OF 2022-23 BOQ 03-05-2023
3 03-May-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-05-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 138300.0 /-
Tender Value
INR 75.51 Lakhs /-

BOQ Items

Name of Work :PROVN OF TRANSFORMER AND ALLIED SERVICES AND SPL REPAIR/REPLACEMENT OF LT CABLES AND LT PANELS AT VARIOUS UNITS AT HISAR MIL STN UNDER GE HISAR
Sl. No. Item Description
1Supply, installing, testing and commissioning outdoor type, floor mounted step downtransformer, 11 KV/433 Volts (at no load) AC 3 phase 50 Hz, 400 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural- Air Natural , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +5.0%, +2.5%, 0%, -2.5%, -5.0%, -7.5% & -10.0% on HV side to be changed by means of hand operatedoff load tap changer gear. The maximum temperature rise should not exceed 40 degree Celsius in oil and 45 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run. The transformer shall be confirming to IS-1180 (updated), level-II complete all as specified and directed and shall comprise of the following:-(i) Three Nos porcelain bushing suitable for 11 KV on HV side complete withcopper rods, nuts and washers.(ii)One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out of 400 sq mm 3.5 core , LT 1100 volts grade PVC/ XLPE insulated & sheathed, heavy duty, armoured cables including joint and jointing materials complete. (iii) Oil conservator with filter type drain valveand oil level gauge. (iv) De-hydrating breather with first fill of dehydrating agent (silica gel). (v) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs for complete transformer and as well as core and winding assembly, Oil filling hole with cap / plug with connection plate complete, Air release valve plug and four Nos plain solid cast steel detachable rollers. (vi) One No 100 mm dia, dial type thermometer, vaporpressure type, having range 0-120 degree Celsius withmetal guard having maximum perimeter temperature readingindicator with re-setting device. (vii) Two earthing terminals on tank cover to facilitate fixing of 25 x 4mmgalvanized iron earth strip forearthing ofbody and one no. HV side neutral grounding earth strip. (viii) Rating plate and terminal marking plate. (ix) Extra bushing for neutral, in the LT cable box for providing independent set ofearthing for neutral. (x)First filling of new and unused transformer oil, IS-335 marked (Make Savita /Power Link) filtered and tested upto 40 KVdielectric strength at 2.5 mmair gap between testing electrodes.(xi)One filter valve on the upper side of tank. (xii) Arcing horns for HT side (01 No per phase) Note : Poles their fixing/ errection and structural steel work shall be measured and paid for separately.
2Rationalization of transformer by dismentaling old serviceable transformer 150KVA to 300 KVA frominexisting location, removeing all connection and shift other location with in Hisar Mil Station approx 1.00KM, re-connection complete
3Supply, installation, commissioning and testing of feeder pillar boardKiosktype ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled ,outdoor type with provn of both side cable allay, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 5mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thickMS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality) over a coat of red oxide primer completemounted on angle iron 40mm x 40mm x 5 mm legs 45 cm high above GL and 15 cmembedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following.(a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bar installed on porcelain insulator of rating not less than 1.5 times the rated capacity of theincomer MCCB ,as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming :-(i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade,630 amps rating 4 pole,36 KA, Thermal Magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=100%Icu).-01 No. (ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted , with three way rotary selector switch-1 No.(iii)Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no.(iv) Three Nos CTs of suitable ratio (set of three)-01 Set (v) Indicating lamps (R,Y,B) - 01 set of three (c) Outgoing (i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade250 amps ratingand 36 KA rupturing capacity, adjustable type( Ics=100%Icu). -03 No. (d) Fine wiring with single core copper conductor for instruments / indicating lamps-01 Job. Note:-(i)All incoming/ outgoing cables shall be connected by suitable size gland plate /glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar).
4Supply, installation, commissioning and testing of feeder pillar boardKiosktype ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type,weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 5mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thickMS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality) over a coat of red oxide primer completemounted on angle iron 40mm x 40mm x 5 mm legs 45 cm high above GL and 15 cmembedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm including taking down existing LT panel and comprising of the following.(a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of theincomer MCCB ,as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.(b) Incoming :-(i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade,500 amps rating 4 pole,36 KA, Thermal Magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=100%Icu).-01 No.(ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted , with three way rotary selector switch-1 No.(iii)Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no.(iv) Three Nos CTs of suitable ratio (set of three)-01 Set(v) Indicating lamps (R,Y,B) - 01 set of three(c) Outgoing (i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade,250 amps ratingand 36 KA rupturing capacity, adjustable type( Ics=100%Icu). -02 No.(d) Fine wiring with single core copper conductor for instruments / indicating lamps-01 Job.Note:-(i)All incoming/ outgoing cables shall be connected by suitable size gland plate /glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar).
5Supply, installation, commissioning and testing of feeder pillar boardKiosktype ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type,weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 5mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thickMS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality) over a coat of red oxide primer completemounted on angle iron 40mm x 40mm x 5 mm legs 45 cm high above GL and 15 cmembedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm including taking down existing LT panel and comprising of the following.(a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of theincomer MCCB ,as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.(b) Incoming :-(i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade,320 amps rating 4 pole,36 KA, Thermal Magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=100%Icu).-01 No.(ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted , with three way rotary selector switch-1 No.(iii)Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no.(iv) Three Nos CTs of suitable ratio (set of three)-01 Set(v) Indicating lamps (R,Y,B) - 01 set of three(c) Outgoing(i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade,200 amps ratingand 36 KA rupturing capacity, adjustable type( Ics=100%Icu). -02 No.(d) Fine wiring with single core copper conductor for instruments / indicating lamps-01 Job.Note:-(i)All incoming/ outgoing cables shall be connected by suitable size gland plate /glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar).
6Taking out the old unserviceable HT underground cable 95 sqmm3core 11000 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed .
7Supplying, laying jointing testing and commissioning ofHT undergroundXLPE insulated, screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11KV grade (Earthed) of size 95 sqmm 3 coreconfirming to IS-7098 Pt-IIcable laid in trenches/walls/ducts/poles etc.complete all as specified and directed.
8Taking out the old unserviceable LT underground cable any size, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed .
9Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core
10Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core
11Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core
12Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc. and for foundation of poles, stays etc. n exc 10 sqm on plan and n exc 1.5 in depth and getting out complete all as specified and directed.
13Description all as per serial No 12 above but hard /dense soil
14Description all as per Serial item No "12" above but depth exceeding 1.5 mtr and not exceeding 3.00 mtr.
15Returning filling in incl spreading levelling watering and well ramming in layers n. exc 25cm thick of soft/loose soil intrenches/pitcomplete all as specified and as directed.
16Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and as directed. .
17M & L Sand cushioning to underground cable in tranches in layer of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed . Note : Punned thickness shall be measured and paid for.
18supply and laying un reinforced precast concrete cable cover of class HV Type -1 with flat size 300x180x40mm fixed in replacement any type bricks of PCC covers.
19Taking out existing unserviceable/servicavle bricks over UG cables, from tranches and stacking at site for re use competed all as specified and directed
20Laying only old serviceable brick cover retrieved above complete all as specified and directed.
21M & L Brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, and perpendicular to the direction of cable complete.
22Material & labourcement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed by Engineer- in-charge.
23Material & labour PCC 1: 3 : 6 type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in mass concrete including necessary form work complete all as specified and directed.
24M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles complete all as specified and directed.
25Material & labour for CrossArms bracings supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts , washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat ofaluminiumpaint complete all as specified and directed.
26Supply and fixing GI tube light grade of size 100 mm dia galvanised with all fittings fixed to walls/floors/poles or under road etc complete all as specified and directed.(Note :-The GI pipe should be fixed with pole by MS clamps if necessary.(The MS work should be measured and paid separately).
27M&L for providing 100mm PCC platform on top of brick masonry of size 6x3 mtrs (outer dimension) and 1.2 mtr hight from ground level and 0.5 mtr blow ground for placing RMU/Transformer chain-link fencing around the platform fixed to angle iron post 1.8 mtr high using angle iron for size 40x40x6mm and 1.00 m away from platform with entry gate and steps and applying a coat of black bituminous paint over a coat of red oxide primer on the steel surface comple all as specified and directed including provision as under :- (I) 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation of brick wall and fencing post including excavation & earthworm, return fillilng in and removal of surplus soil.(ii)Brick work with fly ash brick in CM 1:6 including 15mm thick plastering in CM 1:4 over exposed surfaces.(iii) 100mm thick hard core using brick bats of grade n exc 63mm (iv) 100mm thick PCC(1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base. (v) 100mm thick PCC(1:2:4) type B2 (using 40mm graded stone aggregate) as in flooring finished even and fair.(vi) Two coats of cement base paint over a coat of cement primer over plastered surfaces complete. (vii) Chain link MS galvanised fencing of mesh size 75mmx 75mm and dia of wire 3mm including 10mm dia MS round bar to support the chain link fencing complete (viii) Earth filling including watering and ramming in layers of 25cm inside the platform complete (Earth obtained from excavation shall be used for filling)
28Supply, errecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 11 mtr long , 152 mm x 152 mm at top and 152 mm x 260 mm at bottom,class 9 complete as specified & directed .
29Supply and install HT 11 KV outdoor type gang operated air break switch suitable for horizontal mounting rotating type complete with 9 insulators of rating upto 200 Amps
30Supply and installation of drop out fuse assy single pole 11KV , 25 Amps rating complete expulsion fuse element mounted on four /two pole structures all as specified and directed.
31Supply and fixing Lightning arrester suitable for 11KV expulsion type complete with all fitting , transmission class , discharge capacity 65 kilo amp.
32Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth leadirown strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion.Note: The unit rate including for protection open and GI strip 24x4mm from top of earth plate up to 7.5mtr above ground level.
33Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion. Note: The unit rate including for protection open and GI wire 4mm dia from top of earth plate up to 7.5mtr above ground level.
34M&L for cable jointing kit for 11 KV (earth) grade cable for outdoor termination hot shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 95 sqmm complete all as specified and directed.
35Taking out Unsv U/G cableof any size along with cable cover from Trenches and stacking serviceable / unserviceable bricks / PCC cover at site for re-use complete all as specified & directed.
36Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- (a) 400 Sqmm 3.5 core
37Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- (b) 300 Sqmm 3.5 core
38Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- (c) 185 Sqmm 3.5 core
39Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:-(f)70 Sqmm 3.5 core
40Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- (g) 16 Sqmm 4 core
41Supply, installation, commissioning and testing ofLT Panel, LT(415 Volts, 50 Hz3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type,weather and vermin proof (Protection Class IP-54) made out of3.15 mm(for external) and 2 mm (for internal) thickMSCRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality over a coat of red oxide primer completemounted on angle iron 40mm x 40mm x 6 mm legs 45 cm high above GL and 15 cmembedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following :- (a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of theincomer MCCB ,as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming :- i) Air Circuit Breaker 4 Pole, 415 V, Manual Drawout type with Intelligent micropro releases with communication protocol (modbus / profibus) RS485 Modular construction with most compact dimensions, High mechanical & electrical operating Life, Conforms to IS/IEC 60947-2 & IEC 60947-2 of capacity 800 Amps 65 KA -1 No (ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted , with three way rotary selector switch-1 No. (iii)Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no. (iv) Three Nos CTs of suitable ratio (set of three)-01 Set (v) Indicating lamps (R,Y,B) - 01 set of three (c) Outgoing (ii)MCCB 4 Pole, 415 V, with Microprocessor release 200 Amps with breaking capacity 36 KA -6 Nos (d) Fine wiring with single core copper conductor for instruments / indicating lamps-01 Job. Note:-(i)All incoming/ outgoing cables shall be connected by suitable size gland plate /glands and All spreader terminals of MCCBs should be connected with extension links (bus bar). (ii) Takingout of all connections from old panels, dig out loop of cables dressing andproviding new thimbles and connecting to new panel MCCB, bus bar included in unit rate of items. (iii) Removing of all old debries of old plinth/panels from site included in unit rate.
42Supply installed testing and comminsioning indoor type , outdoor type,Self standing, double door, front and back openable, APFC panelcompartmental type with APFC relay 8 stage with heavy duty MPP capacitor bank 120KVAR (5 KVAr-3Nos, 10 KVAr-03 No, 25KVAr-01 Nos, 50KVAr-01 Nos, with 7% detuned harmonics filter reactor. ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each control and MCCB TPN 250 Amp 36 KA as incomer including control CT & control wiring complete having following assessories including control wiringwith HR FRLS copper wire complete all as specified (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry (ii) Capacitor installed in removable assemblies for ease of operation and maintenance (iii) Incoming of APFC panel of MCCB TPN 250 Amps, 36 KA breaking capacity with high electrolytic grade Aluminium bus bar iof suitable rating. (iv) 120KVAR (5 KVAr-3Nos, 10 KVAr-03 No, 25KVAr-01 Nos, 50KVAr-01 Nos ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor. (v) High performance microprocessor based 3 phase APFC relay 8 stage withAuto/Manual Option. (vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter. (vii) Capacitor dutythyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors (viii) Induced air system provided with axial flow fan/ centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front
43Supply, installation, commissioning and testing ofLT Panel, LT(415 Volts, 50 Hz3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type,weather and vermin proof (Protection Class IP-54) made out of3.15 mm(for external) and 2 mm (for internal) thickMSCRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality over a coat of red oxide primer completemounted on angle iron 40mm x 40mm x 6 mm legs 45 cm high above GL and 15 cmembedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following :- (a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of theincomer MCCB ,as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming :- (i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade, 630 amps rating 4 pole,50 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=75%Icu).-01 No. (ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted , with three way rotary selector switch-1 No. (iii)Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no. (iv) Three Nos CTs of suitable ratio (set of three)-01 Set (v) Indicating lamps (R,Y,B) - 01 set of three (c) Outgoing (i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade, 250 amps rating 4 pole,36 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=100%Icu).-02 No. (ii)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade 200 amps ratingand 36 KA rupturing capacity, adjustable thermal and fixedmagnetic type( Ics=100%Icu). -01 No. (iii)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade 63 amps ratingand 25 KA rupturing capacity, adjustable thermal and fixedmagnetic type( Ics=50%Icu). -01 No. (iii)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade 40 amps ratingand 25 KA rupturing capacity, adjustable thermal and fixedmagnetic type( Ics=50%Icu). -01 No. (iv). On Load Changeover switch 400 Amp 4 pole. Make Havells cat part no:IHCNFE0400-1 Nos (d) Fine wiring with single core copper conductor for instruments / indicating lamps-01 Job. Note:-(i)All incoming/ outgoing cables shall be connected by suitable size gland plate /glands and All spreader terminals of MCCBs should be connected with extension links (bus bar). (ii) Takingout of all connections from old panels, dig out loop of cables dressing andproviding new thimbles and connecting to new panel MCCB, bus bar included in unit rate of items. (iii) Removing of all old debries of old plinth/panels from site included in unit rate.
44Supply, installation, commissioning and testing ofLT Panel, LT(415 Volts, 50 Hz3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type,weather and vermin proof (Protection Class IP-54) made out of3.15 mm(for external) and 2 mm (for internal) thickMSCRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality over a coat of red oxide primer completemounted on angle iron 40mm x 40mm x 6 mm legs 45 cm high above GL and 15 cmembedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following :- (a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of theincomer MCCB ,as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming :- (i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade, 630 amps rating 4 pole,50 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=75%Icu).-01 No. (ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted , with three way rotary selector switch-1 No. (iii)Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no. (iv) Three Nos CTs of suitable ratio (set of three)-01 Set (v) Indicating lamps (R,Y,B) - 01 set of three (c) Outgoing (ii)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade 315 amps ratingand 36 KA rupturing capacity, adjustable thermal and fixedmagnetic type( Ics=100%Icu). -02 No. (ii)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade 200 amps ratingand 36 KA rupturing capacity, adjustable thermal and fixedmagnetic type( Ics=100%Icu). -01 No. (iii)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade 63 amps ratingand 25 KA rupturing capacity, adjustable thermal and fixedmagnetic type( Ics=50%Icu). -02 No. (d) Fine wiring with single core copper conductor for instruments / indicating lamps-01 Job. Note:-(i)All incoming/ outgoing cables shall be connected by suitable size gland plate /glands and All spreader terminals of MCCBs should be connected with extension links (bus bar). (ii) Takingout of all connections from old panels, dig out loop of cables dressing andproviding new thimbles and connecting to new panel MCCB, bus bar included in unit rate of items. (iii) Removing of all old debries of old plinth/panels from site included in unit rate.
45Supply, installation, commissioning and testing ofLT Panel, LT(415 Volts, 50 Hz3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type,weather and vermin proof (Protection Class IP-54) made out of3.15 mm(for external) and 2 mm (for internal) thickMSCRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality over a coat of red oxide primer completemounted on angle iron 40mm x 40mm x 6 mm legs 45 cm high above GL and 15 cmembedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following :- (a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of theincomer MCCB ,as well as outgoings shall have aluminium TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (b) Incoming :- (i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade, 630 amps rating 4 pole,50 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=75%Icu).-01 No. (ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted , with three way rotary selector switch-1 No. (iii)Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no. (iv) Three Nos CTs of suitable ratio (set of three)-01 Set (v) Indicating lamps (R,Y,B) - 01 set of three (c) Outgoing (i)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade, 200 amps rating 4 pole,36 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=100%Icu).-04 No. (ii)MCCB 4 pole , LT 415 Volts, 50 Hz ACgrade 63 amps ratingand 25 KA rupturing capacity, adjustable thermal and fixedmagnetic type( Ics=50%Icu). -01 No. (d) Fine wiring with single core copper conductor for instruments / indicating lamps-01 Job. Note:-(i)All incoming/ outgoing cables shall be connected by suitable size gland plate /glands and All spreader terminals of MCCBs should be connected with extension links (bus bar). (ii) Takingout of all connections from old panels, dig out loop of cables dressing andproviding new thimbles and connecting to new panel MCCB, bus bar included in unit rate of items. (iii) Removing of all old debries of old plinth/panels from site included in unit rate.
46M&L for stay assembly with all accessories as shown in Electrical Plate No 1 of SSR Part I (2009) with 16 mm dia stay rod and including 7/2.24 mm size stay strand and stay clamps including loop insulator a complete all as specified and directed. Note :, excavation, earth work and concrete shall be measured and paid separately under relevant items of this schedule.
47Dismantling of ACSRconductors
48Dismantling of Earth Wireconductors
49Dismantling cross-arms of M.S. channel or angle sections etc. complete
50Dismantling insulators any type, any size
51M&L for Boring of holes under road, pavement, hard standing by trenchless technology/by drilling technique suitable to cross 40mm or 80mm pipe complete all as specified and directed by Engineer-in-charge.
52M&L for Galvanized iron tubing, 40mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
53M&L for Galvanized iron tubing, 80mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.