Tender For Addition Alteration To Existing Ht Network (For Conversion To Underground System) Under Ge Faridkot, faridkot-Punjab

Military Engineer Services-MES has published Tender For Addition Alteration To Existing Ht Network (For Conversion To Underground System) Under Ge Faridkot. Submission Date for this Tender is 10-06-2023. LAN Tenders in faridkot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

37045301
Corrigendum : Tender For Addition Alteration To Existing Ht Network (For Conversion To Underground System) Under Ge Faridkot
Open Tender
Indian
Punjab
faridkot
10-06-2023

Tender Details

Addition Alteration To Existing Ht Network ( For Conversion To Underground System ) Under Ge Faridkot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Apr-2023 Corrigendum 01 Date 11-05-2023
2 01-May-2023 Corrigendum 02 Date 18-05-2023
3 08-May-2023 Corrigendum 03 Date 27-05-2023
4 18-May-2023 Corrigendun 04 Date 03-06-2023
5 22-May-2023 Corrigendum 05 BOQ 03-06-2023
6 25-May-2023 Corrigendum 06 Other 03-06-2023
7 03-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-06-2023

Key Value

Document Fees
INR 2000 /-
EMD
INR 440000.0 /-
Tender Value
INR 3.65 Crore /-

BOQ Items

Name of Work : ADDN/ALTN TO EXISTING HT NETWORK (FOR CONVERSION TO UNDERGROUND SYSTEM) UNDER GE FARIDKOT (Job No 16R/AMWP/2022-23/02)
Sl. No. Item Description
1Lump sum price worked out by the tenderer for“BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
2Lump sum price worked out by the tenderer for“INTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - II (Part-I)
3Sch "A" Sec - II (Part-II), (INTERNAL ELECTRIFICATION WORKS)
4Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 60mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ).
5All as per above Srl item No. 04 but for onesocket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
6All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).
7Material and labour for concealed Point wiring for onesocket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 60mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).
8Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of "B" class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
9Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Cycle per second, size 300mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement in wall and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
10Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Cycle per second, size 450mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement in wall and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mmdrawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
11Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) TPN, 8 Way 415V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
12Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB complete all as specified and as directed by Engineer-in-charge
13Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA,fixing in DB complete all as specified and as directed by Engineer-in-charge
14Supply and fixing LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) CRI: More than70
15Supply and fixing LED complete fitting batten and rod, T-8 Retro LED tube polycarbonate housing 1 x 20Watt, appx 4 feet long, with decorative box linear LED lighting fixture with CRCA housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g) CRCA pre coated housing with coloured plastic end cap.(h) LED Driver of the same make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K(m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
16Supply and fixingLED light fitting 1 x 5Watt, appx 1 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting,complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95(e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap.(h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV.(l) CCT : Minimum 6000K(m) CRI : Minimum 80(n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
17Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
18Subtotal
19Lump sum price worked out by the tenderer for“INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III
20Lump sum price worked out by the tenderer for“ROAD, PATH & CULVERT WORK" as listed in Schedule ‘A’ Section -IV (Part-I)
21Sch "A" Sec - IV (Part-II), (ROAD, PATH & CULVERT WORK)
22Supply and laying/fixing 80 mm thick (M-40 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment,any shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.
23Supply and laying factory made kerb stone of M-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed.
24Subtotal
25Lump sum price worked out by the tenderer for“AREA DRAINAGE WORK)" as listed in Schedule ‘A’ Section -V (Part-I)
26Sch "A" Sec - V (Part-II), (AREA DRAINAGE WORK)
27Material and labour for Pre-cast factory made RCC drain of size and shape as directed by GE alongwith male and female ends for proper joining, made of 75mm thick RCC (1:1.5:3) Type B-1 using 20mm graded aggregate and reinforced with 8mm TMT bars @ 100mm c/c both ways, duly embeded two Nos socket for hoisting including form work etc, hosting and placing at site and jointed in CM (1:4) to form uniform length and fair finish to drain upto 80cm girth (width measured @ Avg of inner and outer girth) complete all as specified and as directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid separately under appropriate item of this Sch.
28Subtotal
29Lump sum price worked out by the tenderer for“SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - VI (Part-I)
30Sch "A" Sec - VI (Part-II), (SEWAGE DISPOSAL WORK)
31Supply and laying DWCPE (SN8) drain pipes 150mm nominal dia as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thhick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under appropriate item of BOQ/Sch A.
32Subtotal
33Lump sum price worked out by the tenderer for“SECURITY FENCING, COMPOUND WALL AND GATE WORKS" as listed in Schedule ‘A’ Section - VII
34Lump sum price worked out by the tenderer for“EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - VIII (Part-I)
35Sch "A" Sec - VIII (Part-II), (EXTERNAL WATER SUPPLY WORKS)
36Material and labour for drilling or Cutting of existing CI/DI pipes line any dia for taping (for making water connection with 50mm GI pipe) including jointing material as required like clamp, tapping kit, nut bolts, gasket, tee etc in trenches complete all as specified and as directed. NOTE:- (i) Necessary earth work, jointing material reqd to complete the job deemed to be included in the quoted rate. (ii) GI pipe shall be measured and paid separetly
37Material and labour for Construction of brick masonary valve pit chamber size 45 X 45 X 45 cm (internal dimension) using sub class "B" bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:4:8) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, 23cm thick brick work in cement mortar (1:4), inner plaster 15 mm thick in cm (1:4) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.
38Subtotal
39Lump sum price worked out by the tenderer for“EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)
40Sch "A" Sec - IX (Part-II), (EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION WORKS)
41Sand cushioning, with dry and clean river sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used.
42Supply and fixing jumper wire PVC bedded electric power cable (heavy duty) with aluminium conductor 11 KV (E) grade cross sectional area 50 Sqmm single core as jumper / connecting lead on section pole of OH line, GODs, HT Fuses etc complete all as specified and as directed.
43Supply and laying loose filling 40mm graded stone aggregate in, under and around the 2/4 pole structure, sub station and transformer complete all as specified and as directed.
44Material and labour for cable route indicator post of size 900x300x100mm made of precast cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate, rounded tops as directed and embeded in ground (450mm below ground and 450mm above ground level) with PCC (1:3:6) type C-1, using 20 mm graded stone aggregate block of size 350x150x450mm, including 5 mm thick plastering all round of exposed surface of post above ground with CM (1:4) and finished even and smooth without using extra cement, applying two coats of cement base paint on plastered surface including writing letters (like LT/HT UG cable, __ feeder etc.) with synthetic enamel paint in brown colour in suitable size including earth work and form work complete all as specified and as directed.
45Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. (iv) Qty 01 Nos for Sch "A" Sec - II (Part-II), (INTERNAL ELECTRIFICATION WORK) and Qty 06 Nos for Sch "A" Sec - IX (Part-II) (EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION WORKS)
46Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
47Supply, installation, testing and commissioning of maintenance free earth grid (grounding) of interconnected two earth electrode of size 85 mm dia x 3 mtr long each metal conductor of electrode shall be Copper bounded MS strip of 50x6 mm Copper bounding of MS rod/ strip should be Min 250 microns. Earth electrode of 85 mm, depth 3 mtr shall be placed augured bore hole and embedding of interconnected strip shall be cast in high purity electrically conductive granuler material having ultra-low resistive value 0.001 Ohm-m resulting in increase of the effective surface area of the earth grid to lower the earth resistance conductive earth enhancing material shall be mix with cement in the ratio 3:1 which should not leach chemicals into the adjacent soil or underground water channels and should be in pH neutral range. Earth enhancing material should permanently proted the encased metal components of the earthing system. All hardware like nuts, bolts and washers should be of stainless steel Electrode should withstand fault current upto 35 KA for 1 second, electrodes top terminal be sealed permanently packed with conductive concrete and test link of Cu bonded MS/Copper strip of size 50x6x200 mm shall be taken out to connect the equipment. Test certificate of NABL laboratory shall be submitted by the contractor, RCC pit cover including brazing of all the joints upto the test point complete all as specified and directed. No pre cast electrodes to be used. Make:- Elancrete/ Vasconite/ Electroguide / SG power Pvt Ltd Note :- (i) Test certificate of earthing certified NABL laboratory shall be submitted & verified by GE. (ii) Test reports should not be more than 5 years old. (iii) Test report for fault current ohms, compliance and resistivity value from NABL certified/ CPRI lab is must and it has to be verified by GE.
48Supply and fixing Sheet metal enclosure (DB) outdoor type made out of CRCA sheet powder coated and shall be mounted on angle iron frame and legs made from angle iron of suitable size, legs shall be grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) including earth work, frame and legs painted with 2 coats of synthetic enamel paint over a coat of red oxide primer, pre-wired circuit should be multistrand FRLSH min size of minmum 10 sq.mm copper cable, suitable size and fitted with and including the following accesories complete all as directed :- (i) MCCB 63 Amp, FP, 25KA - 01 No (ii) MCCB 25 Amp, FP, 16 KA - 01 No (iii) MCB 40 Amp, SPN, 10 KA - 02 Nos (iv)Automatic Street Light control Switch using Infrared red Sensor based three phase NATURAL SWITCH for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux level, required illuminance Level for Switching ON is = 30 Lux and for Switching OFF = 10 Lux. The Sensor should have part night operation facility of minimum 4 hrs. to max. 12 hrs. The Sensor along with suitable power contactor of 20 to 32 Amp current rating etc and circuit should also have provision for manual operation (i.e. Sensor By-pass option). (v) Multifunction meter Digital type showing Voltage, Amp , Frequency, KW , KWH, PF inbuilt selector switch with CT coils for three phase- 01 No (vi) LED Indicated Lamps
49Supply and fixing cable junction box of Size 250mm x 200mm x 105mm or any other higher size complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :- (a) The junction box shall be rated for degree ofIP 66 (ingress protection) in accordance with IEC 60529. (b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded and 63 A four pole terminal stud. (c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60670-22, IEC-60670-22, IEC 60670-2 to 5 and grey color according to RAL 7035. (d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree. (e)Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08.(g) Junction box with stud type terminal, 63A flame retardant one number 6 Amp MCB SP 10KA (h) Manufacturer should submit routine test certificate for junction box. (j) Clamps and screws for fixing of junction box shall be made of SS-304
50Supply and fixing energy efficient LED street light fitting of 60W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/Roadway luminaire, with driver, fixing the light fitting with and including bracket made out of GI tubing light grade 40mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps suitable size made out of MS Flat iron of size 25x4 mm with nuts and bolts for fixing of bracket along pole or as directed including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications,complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : Minimum IP65. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
51Supply and fixing 1100 Volt grade, PVC insulated Round/flat Sheathed, Copper Conductor (flexible) industrial cable (3x1.5 Sqmm) three core for connection to street light fitting from junction box to light fitting drawn through inside of tubular poles or along existing protection pipe of pre-stressed concrete pole complete all as specified and as directed.
52Material and labour for drilling / boring of holes (horizontally) under main road pavement, hard standing or any other situation by manual mean for accommodate 40 to 100mm bore GI tube (light grade) in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (GL pipe and cable shall be measured and paid separately)
53Supply, installation, testing and commissioning of 11 KV, 800 Amp, 26.2 KA for 1 Sec, 350 MVA HT Vacuum circuit breaker standalone incomer, outgoing panel confirming to IS 13118-1991/IEC 62271-200, to be coupled with existing 11 KV VCB panels as directed by Engr-in-Charge comprising of the following:-
54630 Amps continuous rated electrolytic copper bus bars, droppers and bus bars insulated with full system voltage sleeves.
55Trolley mounted vacuum circuit breaker having three No resin encapsulated vacuum bottles of the same manufacturer as of circuit breaker.
56Motorized spring charging mechanism with integral spring charging handle for manual spring charge.
57Inter panel epoxy barrier to restrict are propogation from one panel to other.
58Epoxy Casted current transformer 11 KV, 200-100/5A, core 1:15 VA, class 0.5, core 2: 15 VA, class 5P10.
59Accessories like local remote switch breaker control switch (T-N-C), space heater with thermostat, DC & AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF breaker in Service/Test.
60Multifunctional meter model No EM 6400 of CONSERV
61Digital Ammeter CT Sec : 5A, Flush MTG, CTR - 200 - 100/5+5A, Accuracy class : 1.0, Aux, Supply : 230V AC.
62Separate master trip relay, type of mounting on panel : flush mounting type, case size of relay : As per manufacturer, No and type of contracts : As per manufacturer, Relay flag - Flag required, Auxiliary supply AC/DC : 110V DC.
63Comprehensive numerical protection relay : Model type : CGI 14N Relay 110V DC, Designation of relay : CGI 14N, Numerical Non-communicable FP IDMTL + INST 30/C +1E/F Relay flush mounted type, over current IDMLT setting - 5% to 200% of CT secondary, Earth fault IDMTLsetting - 5% to 200% of CT secondary, instantaneous O/C setting 50-1600% in step of 1% , Having the following additional facilities : - (i) Trip check supervision(ii)Disturbance recorder(iii)Event log with date and time.
64Panel having the following additional facilities :- (i)Continuous rated closing and tripping coil. (ii)Fully internal arc type tested as per latest IEC 62271-200(iii)Vacuum bottle should be epoxy encapsulated.(iv)Racking in/out, manual closing/tripping of CB with compartment door closed.
65Breaker shall be provided with following contacts (i)Auxiliary switch with 6 No ± 6 NC mounted on the draw out protection of the switchgear.(ii)Position switch with 3 No + 1 NC contacts for each position in service and test.
66Note :-(i)All relays shall be microprocessor based.(ii)Panel height should not exceed 2300mm.(iii) Fabricating, erecting of HT copper bus bar of 630 Amps capacity of suitable length for connecting of new panel with alley of existing HT panels by necessary openings/cutting sheet of panels, incl all fixing materials like copper bus bar, nut, bolts, washers and T&P required at site to make the entire system function able. All material deemed to be included in the rate quoted and nothing extra payment on this account will be admissible to the contractor. (iv) Drawing shall be approved by GE before fabrication.
67Supply, installation, testing and commissioning of 11 KV, 400 Amp, 26.2 KA for 1 Sec, 250 MVA HT Vacuum circuit breaker standalone incomer, outgoing panel confirming to IS 13118-1991/IEC 62271-200, to be coupled with existing 11 KV VCB panels as directed by Engr-in-Charge comprising of the following.
68630 Amps continuous rated electrolytic copper bus bars, droppers and bus bars insulated with full system voltage sleeves.
69Trolley mounted vacuum circuit breaker having three No resin encapsulated vacuum bottles of the same manufacturer as of circuit breaker.
70Motorized spring charging mechanism with integral spring charging handle for manual spring charge.
71Inter panel epoxy barrier to restrict are propogation from one panel to other.
72Epoxy Casted current transformer 11 KV, 200-100/5A, core 1:15 VA, class 0.5, core 2: 15 VA, class 5P10.
73Accessories like local remote switch breaker control switch (T-N-C), space heater with thermostat, DC & AC control circuit through MCB, indicating lamps for RYB, Spring charge, DC supply healthy, breaker ON/OFF breaker in Service/Test.
74Multifunctional meter model No EM 6400 of CONSERV.
75Digital Ammeter CT Sec : 5A, Flush MTG, CTR - 200 - 100/5+5A, Accuracy class : 1.0, Aux, Supply : 230V AC.
76Separate master trip relay, type of mounting on panel : flush mounting type, case size of relay : As per manufacturer, No and type of contracts : As per manufacturer, Relay flag - Flag required, Auxiliary supply AC/DC : 110V DC.
77Comprehensive numerical protection relay : Model type : CGI 14N Relay 110V DC, Designation of relay : CGI 14N, Numerical Non-communicable FP IDMTL + INST 30/C +1E/F Relay flush mounted type, over current IDMLT setting - 5% to 200% of CT secondary, Earth fault IDMTLsetting - 5% to 200% of CT secondary, instantaneous O/C setting 50-1600% in step of 1% , Having the following additional facilities : - (i) Trip check supervision (ii)Disturbance recorder (iii)Event log with date and time.
78Panel having the following additional facilities:- (i)Continuous rated closing and tripping coil.(ii)Fully internal arc type tested as per latest IEC 62271-200 (iii)Vacuum bottle should be epoxy encapsulated.(iv)Racking in/out, manual closing/tripping of CB with compartment door closed.
79Breaker shall be provided ith following contacts (i)Auxiliary switch with 6 No ± 6 NC mounted on the draw out protection of the switchgear.(ii)Position switch with 3 No + 1 NC contacts for each position in service and test.
80Note :-(i)All relays shall be microprocessor based.(ii)Panel height should not exceed 2300mm.(iii) Fabricating, erecting of HT copper bus bar of 630 Amps capacity of suitable length for connecting of new panel with alley of existing HT panels by necessary openings/cutting sheet of panels, incl all fixing materials like copper bus bar, nut, bolts, washers and T&P required at site to make the entire system function able. All material deemed to be included in the rate quoted and nothing extra payment on this account will be admissible to the contractor. (iv) Drawing shall be approved by GE before fabrication.
81Supply, installation, testing and commissioning HT 11KV, 3PH, 50Hz, CPRI approved IP65 protection AC system outdoor type feeder pillar duly powder coated, to loop one incoming and one outgoing for 95 Sqmm XLPE 11KV cable having following specifications complete all as directed :-
82The cubical of HT feeder pillar of suitable (standard or as directed) shall be made out of 3mm thick CRCA sheet.
83The HT feeder shall have front and rear opening.
84Front compartment shall be suitable for connecting the terminals of cable and rear for cable terminals.
85Cubical shall be provided with two nos of door for front and for back side along with 3 nos of hinges on each door. A centrally operated three position locking arrangements shall be provided for the door.
86Two keys shall be supplied for each feeder pillar.
87In addition, angle cleats shall be provided for putting two nos of padlocks for each size of door.
88Enameled danger board with “DANGER 11000 VOLTS” mark shall be displayed on the left hand side of front and back door.
89Two nos of earthing bolts shall be provided with cubical, one each at front and rear side of pillar. The same shall be easily accessible.
90The cable entry shall be from rear side of the pillar alongwith removable gland plate.
91Cable chamber shall be provided with perforated metal sheet separate for each chamber.
923 nos Bus bars of 500 Amp provided shall be adequately supported on 6 Nos insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication.
93The insulating material used shall be epoxy type insulator, with uniform equally spaced rings, suitable for 22KV class insulation mounting of these insulators shall be with 4 Nos of threaded holes on the central vertical , 10 SWG MS plate.
94Foundation for the panel should be provided with PCC (1:3:6) type C2, at depth of 150mm below GL and 400mm above GL with slot openings for I/C and O/G cables. Base frame for cubical for mounting shall be made out of 40x40x6mm angle iron duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, including excavation and earth work.
95Note :-(i)All fixing materials like copper bus bar, nut, bolts, washers and T&P required at site to make the entire system function able. All material deemed to be included in the rate quoted and nothing extra payment on this account will be admissible to the contractor. (ii) Drawing shall be approved by GE before fabrication.
96Design, manufacture and supply of float cum boost SCR controlled 24 VDC, 25 amps, single phase battery charger and distribution board in a common cubical, the charger is suitable for 230 VAC input & output 24VDC, 100 Ah battery with 12 volt x 2 Nos batteries 100 AH, including heavy duty trolley completeall as directed.
97Supplying and laying synthetic rubber insulated for voltage upto 11 KV for electrical purpose as per IS 15652-2006 (superseding IS 5424) suitable for electrical shock safety of size 2 meter x 1 meter x 20 mmcomplete all as directed.
98Supply of Electric rubber hand gloves insulated voltage upto 11 KVfor electrical purpose complete all as directed.
99Supply & Fix Wooden discharge rod PVC Coated suitable for 11 KV complete all as directed.
100Subtotal
101Lump sum price worked out by the tenderer for“EXCAVATION AND EARTHWORK WORK" as listed in Schedule ‘A’ Section - X
102Lump sum price worked out by the tenderer for“DISMANTLING AND DEMOLITION WORK" as listed in Schedule ‘A’ Section - XI (Part-I)
103Sch "A" Sec - XI (Part-II), (DISMANTLING AND DEMOLITION WORK)
104Dismantling/taking out old earthing any type including all accessories and removing from site complete all as specified and as directed.
105Subtotal
106Sch "A" Sec - XII, (OUTSOURCING OF E/M INSTALLATION WORK FOR FIRST YEAR)
107Providing the services for outsourcing of E/M Installation (66/11KV Grid station) for 11 KV VCBs, Air brake Switches, HT bus coupler, battery bank ,etc.of all sub station area includinginstalled machinery & other assets, maintenance of documents, also keeping clean of the surrounding area of the grid station continuously for 24 hours per day in three shifts of eight hours duration of each shift on all days including Sunday and holidays complete all as specified in Sch "A" notes and as directed by Engineer-in-Charge by engaging the following staff for each shift :- Note :- Contractor Provide HT & LT Fuse wire as per size, HT Insulation Tape, Ladder 9 mtr & 11 Mtr, HT Gloves, DO Stick, HT Meggar, Electrician Tool Bag, Clamp Meter, Torch, Shoes, Biometric Attendance, Fault Register, Voltage Register, Earthing Test Register etc
108Skilled Electrician
109Helper
110Subtotal
111Sch "A" Sec - XIII, (OUTSOURCING OF E/M INSTALLATION WORK FOR SECOND YEAR)
112Providing the services for outsourcing of E/M Installation (66/11KV Grid station) for 11 KV VCBs, Air brake Switches, HT bus coupler, battery bank ,etc.of all sub station area includinginstalled machinery & other assets, maintenance of documents, also keeping clean of the surrounding area of the grid station continuously for 24 hours per day in three shifts of eight hours duration of each shift on all days including Sunday and holidays complete all as specified in Sch "A" notes and as directed by Engineer-in-Charge by engaging the following staff for each shift :- Note :- Contractor Provide HT & LT Fuse wire as per size, HT Insulation Tape, Ladder 9 mtr & 11 Mtr, HT Gloves, DO Stick, HT Meggar, Electrician Tool Bag, Clamp Meter, Torch, Shoes, Biometric Attendance, Fault Register, Voltage Register, Earthing Test Register etc
113Skilled Electrician
114Helper
115Subtotal
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail