| 1 | M&L for servicing/cleaning of split type AC 1.5 /2 Ton of any capacity with suitable chemical/ acid complete all as specified and as directedand as directed by Engineer-in-charge. |
| 2 | M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Split Ac 1.5 Ton complete all as specified and as directedand as directedNote The gas required for charging shall be measured and paid separately under appropriate item of schedule of work.Make:KIRLOSKAR/EMERSON/HITACHI/SRIRAM/TECUM /SCH |
| 3 | M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Split Ac 2 Ton complete all as specified and as directedand as directedNote The gas required for charging shall be measured and paid separately under appropriate item of schedule of work.Make: KIRLOSKAR/EMERSON/HITACHI/SRIRAM/TECUMSCH |
| 4 | M&L for replacement of old unserviceable over load protector / relay package assembly for window type Airconditioner 1.5 Ton, 2.0 Ton capacity of existing make and model complete all as specified and as directedand as directed |
| 5 | S&FThermostatcompleteforSplitTypeACof1.5/2Tontakingouttheold unserviceable one . |
| 6 | S&F Capillary tube includingfilter / stainer completefor Split Type AC of 1.5/2 Ton Type ACand taking out the old unserviceable one . |
| 7 | Supply and replacement ofOutdoor unit fan motor of existing capacity and size for 1.5 Ton /2.0Ton capacitysplit type Airconditionerofany makeand model complete all as specified and as directedand as directed Make: Crompton Greeves/GE/Cool Home/AUE |
| 8 | Supply and replacement of Running capacitor 36 / 45 MFD complete all as specified and as directedand as directed |
| 9 | Supply and replacement ofRunning capacitor50 / 50+6 MFD complete all as specified and as directedand as directed |
| 10 | Supply and repalcement of Evaporator coil made out of copper tubing suitable for Split Type ACindoor unit of capacity 1.5Ton incl necessary welding/brazing and leak testing complete all as specified and as directedand as directedNote: Gas required for topping up will be measured and paid seperately |
| 11 | All as per item No 10 above but of capacity 2.0 Ton capacity complete all as specified and as directedand as directed |
| 12 | Supply and repalcement of condenser coil made out of copper tubing suitable for Split Type ACoutdoor unit of capacity 1.5Ton incl necessary welding/brazing and leak testing complete all as specified and as directedand as directedNote: Gas required for topping up will be measured and paid seperately.Note : Cost of capillary tube will be measured and paid under respective item of the schedule |
| 13 | All as per item No12 above but of capacity 2.0 Ton capacity complete all as specified and as directedand as directed |
| 14 | M&L for complete rewiring of Outdoor Split AC complete all as specified and as directedand as directed |
| 15 | Supply and replacement of Outdoor Unit stand incl removing the old rusted stand for fixing on wall complete all as specified and as directedand as directed |
| 16 | Supply and replacement of remote control unit for Split type Air Conditioner of1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed |
| 17 | Supply and replacement of only PCB circuit of disconnecting of electrical connection of from split AC and taking out the unserviceable PCB and repair ,any type and any make 1.5 Ton, 2 Ton capacity complete all as specified and as directed. |
| 18 | M&L for replacing/fixing of newPCB of Indoor Unit of Spilt Type AC of Existing capacity incl taking down. |
| 19 | Supply and replacement ofcopper capillary tube including filter/stainer complete all as specified and as directed |
| 20 | Supplyandreplacementof brassservicevalveandflurrynutcomplete all as specified and as directed |
| 21 | Supply and replacement of blower motor for Split type Air Conditioner of1.5 Ton capacity of any type and make complete all as specified and as directed |
| 22 | Supply and replacement of blower motor for Split type Air Conditioner of2.0 Ton capacity of any type and make complete all as specified and as directed |
| 23 | S& replacement of Blower fan for Split Type Air Conditioner ofupto 2.0 Ton capacity of any type and make complete all as specified and as directed |
| 24 | Supply and replacement of fan blade of existing sizefor Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed |
| 25 | Supply and replacement of Oscillator motor including blade for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed |
| 26 | S&F Air Filter for Split type AC and taking out the old unserviceable one complete all as specified and as directed |
| 27 | Supply and replacement of Room sensor for Split type Air Conditioner of1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed |
| 28 | Supply and replacement of coil sensor for Split type Air Conditioner of1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed |
| 29 | Supply and replacement of Split Type AC front side PVC grills of suitable size/make as per sample complete all as specified and as directedand as directed |
| 30 | Supply and replacement of insulation kit of copper tubing refrigerent pipe of suction and discharge including sleeves for split AC 1.5 / 2.0 Ton complete all as specified and as directed. |
| 31 | M&L for disconnecting electrical connection, removing copper line, discharge line of split type AC up to 2.0 Ton capacity including indoor and out door units and all accessories and shifting/reinstalling and testing the whole unit of split type AC in new location and making the holes in walls complete all as specified and as directedand as directed |
| 32 | M&Lfor supply and Charging of refrigerant gas for split AC 1.5 Ton AC including cost of welding, leak detection and refitting the same in entire system, including replacing defective liquid strainer and capillary tube including testing & commissioning complete to the satisfaction of Engr-in- Charge. |
| 33 | M&Lfor supply and Charging of refrigerant gas for split AC 2.0 Ton AC including cost of welding, leak detection and refitting the same in entire system, including replacing defective liquid strainer and capillary tube including testing & commissioning complete to the satisfaction of Engr-in- Charge. |
| 34 | Supply and replacement of 2 Pole/3 pole contactors of Indoor Unit for Split Type AC and removing the old Unserviceable one complete all as specified and as directed |
| 35 | Supply and replacement of Display Board of Split Type AC Indoor unit and removing the existing one complete all as specified and as directed |
| 36 | M&L forcomplete wiring kit for Split Type AC of any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing & complete all as specified and as directed |
| 37 | Supply and replacement of PVC Drain pipe 25mm for rectifying water leakage from AC Units complete all as specified and as directed |
| 38 | Supply and replacement of Copper pipe of size 1/4\"dia for connection between indoor and outdoor unit incl necessary brazing work and testing complete all as specified and as directed by Engineer in charge |
| 39 | All as per item No. 38 above but of size 1/2 \" dia complete all as specified and as directed by Engineer in charge |
| 40 | All as per item No. 38 above but of size 3/4 \" dia complete all as specified and as directed by Engineer in charge |
| 41 | All as per item No. 38 above but of size 5/8 \" dia complete all as specified and as directed by Engineer in charge |
| 42 | Supply and charge R-22 gas required for topping up of Split AC |
| 43 | Supply and charge R-32 gas required for topping up of Split AC |
| 44 | Supply and replacement of drier filter suitable for split type AC 1.5 Ton/2 Ton capacity incl necessary brazing complete all as specified and as directed by Engineer in charge |
| 45 | Supply and replacement of liquid line suitable for split type AC 1.5 Ton/2 Ton capacity incl necessary brazing complete all as specified and as directed by Engineer in charge |
| 46 | M&L for servicing/cleaning of Window type Air conditioners of capacity 1.5/2 Ton with suitable chemical acid complete all as specified and as directedand as directed by engineer-in- charge. |
| 47 | M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Window type AC 1.5/2 Ton complete all as specified and as directedand as directedNote:The rate quoted shall be inclusive of refrigerant gas,charging,testing allas directed .Make: KIRLOSKAR/EMERSON/HITACHI/SRIRAM/TECUMSCH |
| 48 | M&L for replacement of old unserviceable over load protector / relay package assembly for window type Airconditioner 1.5 Ton, 2.0 Ton capacity of existing make and model complete all as specified and as directedand as directed |
| 49 | S&F Thermostat complete for Window Type AC taking out the old unserviceable one complete all as specified and as directed |
| 50 | Supply and replacement of blower motor for Window AC upto2.0 Ton capacity of any type and make complete all as specified and as directed |
| 51 | S& replacement of Blower fan for Window AC upto2.0 Ton capacity of any type and make complete all as specified and as directed |
| 52 | S&F copper Capillary tube includingfilter / stainer complete including brazing/leak testing for Window Type AC of any capacity and taking out the old unserviceable one complete all as specified and as directed |
| 53 | S&F condensor fan motor double speed of existing capacity, 230 Volts including blades for Window Type AC and taking out the old unserviceable one.Make: Crompton Greeves/GE/Cool Home/AUE |
| 54 | S&F starting Capacitor 60 MFD complete for Window Type Ac and taking out the old unserviceable one |
| 55 | S&F Running Capacitor45MFD complete for window Type AC and taking out the old unserviceable one |
| 56 | S&F coir filter of suitable size complete for Window type AC and taking out the old unserviceable one. |
| 57 | S&F Selector switch knobfor Window type AC and taking out the old unserviceable one. |
| 58 | Supply only condensercoil/Evaporator coil made out of 25 SWG copper tubing having 30/34G Aluminum Fins per cm length for WindowType AC complete all as specified and as directedand as directed |
| 59 | S&F Air Filter for Window type AC and taking out the old unserviceable one complete all as specified and as directed |
| 60 | S&F Room Sensor for Window type AC and taking out the old unserviceable one complete all as specified and as directed |
| 61 | Supply only Window Type AC front side PVC grills of suitable size/make as per sample complete all as specified and as directedand as directed |
| 62 | M&L for removing electrical connection,shifting of Window type AC upto 2 TON capacity to new location where directed and fixing the same either on window or on wall with required opening and necessary wooden/iron frame work including making good to match with the existing surface complete all as specified and as directed |
| 63 | M&L for supply and charging of refrigerant gas including cost of welding, leak detection and refitting the same in entire system, including replacing defective liquid strainer and capillary tube including testing complete to the satisfaction of Engr-in- Charge for window type AC upto 2.0 Ton all as specified and as directed. |
| 64 | M&L for complete wiring kit for Window Type AC of any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing & complete all as specified and as directed |
| 65 | M&L for servicing/cleaning of Refrigeratorsof any capacity with suitable chemical/ acid complete all as specified and as directedand as directed by Engineer-in-charge. |
| 66 | M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Refrigerator of any capacity upto 320ltr complete including refrigerant gas and charging complete all as specified and as directedand as directedNote : 1.As per the existing make of the Refrigerator .2. The rate quoted shall be inclusive of refrigerant gas,charging,testing complete all as specified and as directed. |
| 67 | M&L for replacement of old over load protector / relay with new over load protector / relay for Refrigeratorof any Capacity complete all as specified and as directedand as directed |
| 68 | S&F Thermostat set complete for Refrigerator of any capcity including removing the old unserviceable complete all as specified and as directedand as directed |
| 69 | S&F Copper Capillary tube includingfilter / stainer with necessary brazing ,Leak testing for Refrigerator of any capacity complete all as specified and as directedand as directed |
| 70 | Supply and charging of refrigerant gas including cost of welding, leak detection and refitting the same in the entire system , testing of refrigeratorof capacity upto 320 ltrs all as specified and as directed.Note: There shall not be any duplication of gas charging for the entire period of contract. |
| 71 | S&FMagnetic door gasket for Refrigerator including removing the old unserviceable complete all as specified and as directed |
| 72 | S&F Refrigerator condensor coil of existing capacity including necessary welding/brazing/pressure testing and removing the old unserviceable one complete all as specified and as directed |
| 73 | S&F fan motor for Refrigerator of any make/capacity and removing the burnt out fan motor complete all as specified and as directed |
| 74 | S&F fan blade for refrigerator and removing the old unserviceable blade complete all as specified and as directed . |
| 75 | M&L for removing the burnt out Glass heater of frost free refrigerator and fixing with new one complete all as specified and as directed |
| 76 | S&FRefrigeratorfreezerboxwithdoorofexistingsizeincludingnecessary welding/brazing/pressure testing and taking out the ols unserviceable onecomplete all as specified and as directed |
| 77 | S&F door handles suitablefor refrigeraor of any capacity and taking out the old unserviceable one. |
| 78 | S&Fvegetable tray of suitable size for refrigerator of capacity upto 380 ltrs incl removing the old damaged item complete all as specified and as directed |
| 79 | M&L for complete wiring kit for Refrigerator of any any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing & complete all as specified and as directed |
| 80 | S&Fall kinds of PVC trays like egg tray, bottle tray etc on the outer door unit of the refrigerator incl removing the damaged u/s trays complete all as specified and as directedand as directed |
| 81 | S&F PCB for refrigerator of any capacity and taking out the old unserviceable one. |
| 82 | M&L for repairing and refixing of PCB for refrigerator of any capacity complete all as specified and as directed |
| 83 | M&L for servicing/cleaning of Deep freezer of existing capacity with suitable chemical acid complete all as specified and as directedand as directed by Engineer-in-charge. |
| 84 | M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Deep Freezerscomplete all as specified and as directedand as directedNote: 1.As per the existing make of the Refrigerator .2. The rate quoted shall be inclusive of refrigerant gas,charging,testing complete all as specified and as directed. |
| 85 | M&L for replacement of old over load protector / relay with new over load protector/relay for Deep Freezerof any Capacity complete all as specified and as directedand as directed |
| 86 | S&F Thermostat set complete for Deep Freezer of any capcity including removing the old unserviceable complete all as specified and as directedand as directed |
| 87 | S&F Copper Capillary tube includingfilter / stainer with necessary brazing ,Leak testing for Deep Freezer of existing capacity complete all as specified and as directedand as directed |
| 88 | M&L for supply and charging of refrigerant gas as per the requirement, including cost of welding, leak detection and refitting the same in the entire system , testing of Deep Freezer all as specified and as directed.Note: There shall not be any duplication of gas charging for the entire period of contract. |
| 89 | S&FMagnetic door gasket for Deep Freezer including removing the old unserviceable complete all as specified and as directed |
| 90 | S&F fan motor for Deep Freezer and removing the burnt out fan motor complete all as specified and as directed. |
| 91 | S&F fan blade for Deep Freezer and removing the old unserviceable blade complete all as specified and as directed. |
| 92 | S&F timer for Deep Freezer of any capacity and taking out the old unserviceable one complete all as specified and as directed |
| 93 | M&L for complete wiring kit for Deep Freezer of any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing & complete all as specified and as directed Note: any Accessories required for this job will be measured & paid separately and taking out the old unserviceable one. |
| 94 | S&F PCB for Deep Freezer of any capacity and taking out the old unserviceable one complete all as specified and as directed |
| 95 | Repairing and Refixing of PCB for Deep Freezer of any capacity . |
| 96 | M&L for servicing/cleaning of water Coolersof capacity upto 150/150 Ltrs with suitable chemical acid complete all as specified and as directedand as directed by Engineer-in-charge. |
| 97 | M&L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Water coolers of capacity 40/80 Ltrs complete all as specified and as directedand as directedNote :The gas required for charging shall be measured and paid separately under appropriate item of schedule of work.Note:The rate quoted shall be inclusive ofrefrigerant gas,charging,testing all as directed. Make: KIRLOSKAR/EMERSON/HITACHI/SRIRAM/TECUM SCH |
| 98 | Replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Water coolers of capacity upto 150/150Ltrs complete all as specified and as directedand as directed Note:The rate quoted shall be inclusive of refrigerant gas,charging,testingcomplete all as specified and as directed. Make: KIRLOSKAR/EMERSON/HITACHI/SRIRAM/TECUM SCH |
| 99 | M&L for replacement of Over load protector / relay package assembly with new OLP/ relay package assembly for Water Coolers upto150 Ltrs capacity complete all as specified and as directedand as directed |
| 100 | S&F Thermostat set complete for water coolers of any capcity including removing the old unserviceable complete all as specified and as directedand as directed |
| 101 | S&F copper capillary tube including strainer with necessary brazing,Leak testing complete for water coolers of any capcity including removing the old unserviceable complete all as specified and as directedand as directed |
| 102 | S&F Condensor fan motor 1/ 16 HP 230 volts including blades complete all as specified and as directedsuitable for water coolers 40/80 , 60/120 & 150/150 Ltrs capacity including removing the old unserviceable. |
| 103 | S&F PVC Ball valve high pressure with polythene float and fly nut screwed for Iron pipe 15 mm dia complete water coolers 40/80 , 60/120 & 150/150 Ltrs capacity including removing the old unserviceable . |
| 104 | S&F Magnetic door gasket for water coolers upto 150/150 Ltrs capacity including removing the old unserviceable. |
| 105 | S&F GI / Stainless steel water drain tray as per suitable size for water coolers upto 150/150 Ltrs capacity complete all as specified and as directedand as directed |
| 106 | S&F PVC Drain pipe 40mm dia for water cooler complete all as specified and as directed and taking out the old unserviceable one. |
| 107 | S&F Running Capacitor 6/10/20 MFD for water coolers as per site requirement complete all as specified and as directedand as directed |
| 108 | S&F starting Capacitor 60/80/100 MFD for water coolers as per site requirement complete all as specified and as directedand as directed |
| 109 | S&F Self closing taps, cast copper alloy, chromium plated screwed for iron pipe 15 mm dia complete all as specified and as directedand as directed suitable for up to 150/150 Ltrs capacity. |
| 110 | M&L for supply and charging of refrigerant gas including cost of welding, leak detection and refitting the same in the entire system , testing of water coolers up to 150 ltrs capacity all as specified and as directed.Note:There shall not be any duplication of gas charging for the entire period of contract. |
| 111 | M&L for spray painting with two coats of synthetic enamel paint over a coat of red oxide primer on water coolers body complete all as specified and as directed |
| 112 | M&L for servicing/cleaning of Desert Coolerany capacity with suitable chemical acid complete all as specified and as directedand as directed by Engineer-in-charge. |
| 113 | Supply and replacement of 4 MFD capacitor complete all as specified and as directedand as directed |
| 114 | Supply and replacement ofdesert cooler front side PVC grills of suitable size/make as per sample complete all as specified and as directedand as directed |
| 115 | Supply and replacement of water lifting pump , 240 V, Single phase submersible type (plastic body) suitable for Desert coolers.Make: Crompton Greeves/GE/Cool Home/AUE |
| 116 | Supply and replacement of wood wool cool pad (Khas- Khas screen 5mm thick (minimum) of required size for side & back panel of coolers (set of three) complete all as specified and as directed. |
| 117 | Supply and replacement of Fan motor 230 Volts, 50Hz, three speed of existing make and capacity including fan blade complete all as specified and as directedand directed.Make: Crompton Greeves/GE/Cool Home/AUE |
| 118 | Supply and replacement of swing motor 230 Volts, 50Hz, including blade for desert coolercomplete all as specified and as directedand directed. |
| 119 | M& L for taking out and dismantling the fan motor from desert cooler, incl cleaning the stator, rewinding with super enamelled winding wire of existing size & gauge including using high quality winding wire including necessary insulation with leathoroid sheet varnishing for winding of coil, making proper insulation etc including cleaning the rotor & the stator, overhauling lubricating with fresh grease, assembling including testing commissioning complete all as specified and as directedand directed |
| 120 | S&F andreplacement of water storage tank made of 20 SWG GI sheet suitable for existing size of desert cooler complete all as specified and as directedand directed. |
| 121 | S&F replacement of side grill (set of three for three side) made of 20 SWG GI sheet as per existing type and size suitable for existing size of desert coolers complete all as specified and as directedand directed. |
| 122 | S&F and replacement of flexible PVC pipe set complete for distribution of water of desert cooler (having droping elbow -3 Nos, distribution 3 way ) as per existing size, including clamping by screw/strip all as specified and directed. |
| 123 | Supply and fix rotary selector switch of three position to control the fan motor of desert cooler of any size/capacity complete all as specified and as directedand directed |
| 124 | Supplyandfixswitchesusedtocontrol waterpumpfordesertcoolerofany size/capacity complete all as specified and as directedand directed |
| 125 | M&L for provisionof Desert Cooler stand with MS steel of required thickness and painting with black colour all complete as specified & directed. |
| 126 | M&L for repairing of body of cooling appliances including denting,cutting worn out portion of body upto 0.5 Sqm area and replacing with MS sheet of same guage including necessary welding,painting etc complete all as specified and as directed |
| 127 | Supply and replacement of old unserviceable Rectifier unit of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed |
| 128 | Supply and replacement of old unserviceable Relay unit of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed |
| 129 | Supply and replacement of old unserviceable indication bulbs of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed |
| 130 | Supply and replacement of Transformer unit for voltage stabilizer from 3 KVA to 5 KVA complete all as specified and as directed |
| 131 | Supply and replacement of Transformer unit o for voltage stabilizerupto 2 KVAcomplete all as specified and as directed |
| 132 | S&F Switch Socket combination 15 Amps 2/3 pin complete all as specified and as directed |
| 133 | Supplyandreplacementof PVCinsulatedandPVCRoundSheathed,Copper Conductor of size three core 1.5sqmm for desert cooler complete all as specified and as directed |
| 134 | Supplyandreplacementof PVCinsulatedandPVCRoundSheathed,Copper Conductor of size three core 2.5sqmm complete all as specified and as directed |
| 135 | Supplyandreplacementof PVCinsulatedandPVCRoundSheathed,Copper Conductor of size three core 4.0 sqmm complete all as specified and as directed |
| 136 | Supply and replacement of Sheet Metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 240 Volts, 20 amps capacity complete all as specified and as directedand as directed |
| 137 | Supply and replacement of plug top 3 pin, 16 Amps complete all as specified and as directed by Engr- In Charge. |
| 138 | Supply and replacement of plug top 3 pin, 6 Amps complete all as specified and as directed by Engr-In Charge. |