Tender For Installation Of Iron Elimination Plant Including Construction Of Blower Room (3.60Mx3.00M) Size, Concrete Platform & Drain For Augmentation At Head Work Site Of Sannyasikata Pwss Zone-Ii Under Jalpaiguri Division, Phe Dte., jalpaiguri-West Bengal

Public Health Engineering Department-PHED has published Tender For Installation Of Iron Elimination Plant Including Construction Of Blower Room (3.60Mx3.00M) Size, Concrete Platform & Drain For Augmentation At Head Work Site Of Sannyasikata Pwss Zone-Ii Under Jalpaiguri Division, Phe Dte.. Submission Date for this Tender is 02-05-2023. Blowers Tenders in jalpaiguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

37023079
Corrigendum : Tender For Installation Of Iron Elimination Plant Including Construction Of Blower Room (3.60Mx3.00M) Size, Concrete Platform & Drain For Augmentation At Head Work Site Of Sannyasikata Pwss Zone-Ii Under Jalpaiguri Division, Phe Dte.
Open Tender
Indian
West Bengal
jalpaiguri
02-05-2023

Tender Details

Installation Of Iron Elimination Plant Including Construction Of Blower Room ( 3.60Mx3.00M ) Size, Concrete Platform & Drain For Augmentation At Head Work Site Of Sannyasikata Pwss Zone-Ii Under Jalpaiguri Division, Phe Dte.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Apr-2023 Corrigendum Notice- I Date 24-04-2023
2 24-Apr-2023 Due Date Extended - 24.04.2023 - slot 3 Admin Corrigendum Date Extend 25-04-2023
3 25-Apr-2023 Due Date Extended - 25.04.2023 - slot 5 Admin Corrigendum Date Extend 27-04-2023
4 29-Apr-2023 Due Date Extended - 27.04.2023 - slot 7 Admin Corrigendum Date Extend 02-05-2023

Key Value

Document Fees
Refer document
EMD
INR 97760.0 /-
Tender Value
INR 48.87 Lakhs /-

BOQ Items

Name of Work :- Installation of Iron Elimination Plant including construction of Blower Room (3.60MX3.00M) Size, concrete platform & drain for Augmentation at head work site of Sannyasikata PWSS Zone-II under Jalpaiguri Division, PHE Dte.
Sl. No. Item Description
1Supplying, Fabrication, Erectionon suitable RCC foundation and Commissioning with 3 (three) months Trial Run (including cost of routine testing of water sample for performance evaluation) of pressuretype Iron removal plant as per design norms of the P.H.E. Dte. with necessary accessories viz. MS fabricated shell with minimum 10 mm thick MS plate with 2 (two)coats of anticorrosive paint & minimum12 mm thick MS media supporting plate fitted with required no. of pot strainer, MS fabricated oxidation chamber with minimum 10 mm thick plate with necessary pipe connection, valves, Gauges & other instruments as required as per departmental approved design & drawing including cost of filter media, Air Compressor & Air blower with motor, starter, main switch etc. of required capacity & approved specification including power connection from main line etc. all complete. Note-1)Rate Excludes The Cost Of Concrete Platform & Drain ,And The Cost Of Blower Room 2) For More Than 50 Cum/Hr,Twin Unit Of Equal Size In Parallel Shall Be Adopted. i) 50 CuM/Hr.
2ii) 30 CuM/Hr.
3Earth work in excavation of foundation trenches or drains or septic tank soak well etc. in all sorts of soil (including mixed soilbut excluding latarite or sand stone) including removing spreading or stack- ing the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of the trenches, leveling dressing and ramming the bottom, bailing or pumping out water etc. as required complete.Depth of excavation not exceeding 1.5 mtr. but not requiring shoring
4Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 15cm. Including watering and ramming etc. layer by layer complete. (Payment to be made on basis of measurement of finished quantity of work)A. with earth obtained from Excavation of Foundation
5Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed & consolidating same by through saturation with water and ramming complete including the cost of supply of sand. (Payment to be made on the basis of measurement of finished quantity of work.)
6Oridinary Cement Concrete M-15 (Mix 1:2:4) with graded stone chips (20 mm.down) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS code 456-2000. (i) River Bazree / (Up to ground level). 12:4 proportion
7Hire and labour charges for shuttering with centreing and necy. staging upto 4m. Using approved stout props and thick hard wood planks of approved thickness with required bracing for conc. slabs, beams, columns, lintels curved or straight includg. fitting, fixing and striking out after completion of works. from foundation to 4m above GL Above 25 mm and upto 30 mm wooden Shuttering as per direction of EIC.
8Plaster (to wall floor ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints, including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor)[Excluding cost of chipping over concrete surface] For Superstructure- b) 15mm thick plaster ii) with4:1 cement mortar In Ground Floor-
9For Ceilling- a)10 mm thick plaster In Ground Floor-
10Neat cement punning about 1.5 mm thick in wall, dado, window, sills, floor, drain etc.Note-cement 0.152 cu.m. per 100 sq.m.
11Supply of CI Jeffy coupling at site. 100 mm dia.
12Labour charges for Jeffy joint of all diameter.
13Making flange joint to CIDF pipe, specials, valves etc.with supply of necessary nuts and bolts, rubber insertion of 6kg/m2 (3mm gauge) and materials required including dewatering if any tools and plants, labour cost etc. as per specification and direction of EIC (Nut and bolts shall be of TATA/GKW make) for 100 mm dia.
1480 mm dia.
15Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latest emended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R- 12/Gr-13 non-magnetic, nuts seat rings are of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS:1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2(seat test) and body tested to 15kg/cm2. 80 mm dia.
16Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] 80 mm to 150 mm dia pipe
17Supply the following materials for connection of inlet, outlet, overflow, washout of OHR as per deptt. Drawings. (A) CIDF pipe Class-B as per I.S. 7181-1986 with latest revision.
18Supply the following materials for connection of inlet, outlet, overflow, washout of OHR as per deptt. Drawings. (B) CIDF Duck foot bend as per I.S. 1538 1976 with latest revision. (C) CIDF Bell mouth pes. with puddle collar as per ISI 1538-1976 with latest revision (D) C.I.D.F 90° Bend as per I.S.1538 (Part-XXI)-1976 with latest amended.
19Construction of Blower Room (3600mm x 3000mm x 3300mm height) having plinth height 600 mm. One number door (1200mm x 2100mm), two numbers window (900mm x 1200mm) fitted with 100mm x 75mm Sal wood frame fitted with 100mm x 58mm x 1.90mm iron butt hinges. One number door and all window made of 35mm thick wooden shutters and 19mm thick panel of Sishu, Gamar, Champ, Badam, Bhola etc. fitted with all necessary fitting such as clamp, butt hinges, iron bolt, socket bolt, D-type handle, door ring etc. MS ornamental grill for window opening, providing 6 nos RCC ventilator in room for arrenging of necessary blower mationary. White washing inside and Protective and Decorative Acrylic exterior emulsion paint over a coat of primer for outside the pump house, painting the grills and wooden works over the coat of primer etc.all complete as per direction of the EIC and as per attached detailed drawing. (Any deviation in plinth height as per site, an additional rate will be add or deduct as per approved departmental analysed rate.for each 50 mm deviation of plinth including column add/deduct rate = Rs 1801.00/-)
20Add GST @ 18%
21Add Labour Wlfare Cess @1%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail