}

Tender For Improvement And Upgr. Of Markets-Streets-Roads Of Shehr-I-Khaas Area On Right Bank Of Jhelum Viz Malarata, Nowhata, Naqshband Sb, Saraf Kadal, Rajouri Kadal, Jamia Masjid Including Allied Works Of Ug Of Utilities, Footpaths, Drainage And Illumi, srinagar-Jammu And Kashmir

Smart City Development Limited has published Tender For Improvement And Upgr. Of Markets-Streets-Roads Of Shehr-I-Khaas Area On Right Bank Of Jhelum Viz Malarata, Nowhata, Naqshband Sb, Saraf Kadal, Rajouri Kadal, Jamia Masjid Including Allied Works Of Ug Of Utilities, Footpaths, Drainage And Illumi. Submission Date for this Tender is 20-04-2023. Footpath Work Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37015435
Corrigendum : Tender For Improvement And Upgr. Of Markets-Streets-Roads Of Shehr-I-Khaas Area On Right Bank Of Jhelum Viz Malarata, Nowhata, Naqshband Sb, Saraf Kadal, Rajouri Kadal, Jamia Masjid Including Allied Works Of Ug Of Utilities, Footpaths, Drainage And Illumi
Open Tender
Indian
Jammu And Kashmir
srinagar
20-04-2023

Tender Details

Tender For Improvement And Upgr. Of Markets-Streets-Roads Of Shehr-I-Khaas Area On Right Bank Of Jhelum Viz Malarata, Nowhata, Naqshband Sb, Saraf Kadal, Rajouri Kadal, Jamia Masjid Including Allied Works Of Ug Of Utilities, Footpaths, Drainage And Illumina

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Mar-2023 Corrigendum No 01 - BOQ Financial Bid 07-04-2023
2 05-Apr-2023 Corrigendum No 02 - BOQ Financial Bid 07-04-2023
3 08-Apr-2023 Extension Notice No 01 Date 15-04-2023
4 16-Apr-2023 Extension Notice No 02 Date 20-04-2023

Key Value

Document Fees
INR 10000 /-
EMD
INR 2492000.0 /-
Tender Value
INR 12.46 Crore /-

BOQ Items

Name of Work:Improvement & Upgradation of Markets/Streets/Roads of Shehri-Khaas area on Right Bank of River Jhelum namely Malaratta, Nowhatta, Naqshband Sahib, Saraaf Kadal, Rajouri Kadal, Jamia Masjid including allied works of Undergrounding of Utilities, Pedestrian Footpaths, Drainage Work, and Illumination etc (Part-A)
Sl. No. Item Description
1Civil Works:
2Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:4:8 or leaner mix (i/c equivalent design mix) including all carriages
3Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge including all carriages All kinds of soil :
4Taking out existing kerb stones of all types from footpath/ central verge,including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge including all carriages.
5Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge including all carriages.
6Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:
7Disposalof Lime, moorum, building rubbish upto 10 km Lead
8Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directedincluding all carriages.
9Providing,laying,spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm) to wet mix macadem (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts , laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density , complete as per specifications and directions of Engineer- in chargeincluding all carriages.
10Flooring with Cobble stone of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3 ( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of Engineer-in-chargeincluding all carraiges.
11Providing and laying in position specified grade of cement concrete excluding the cost of centering and, shuttering , All work up to plinth level 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate (20mm nominal size)including all carriages.
12Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc including all carriages.
13Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge including all carriages.
14Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement including all carriages.
15Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level including all carriages.
16Providing and applying 2.5mm thick road marking strips (retro-reflective) of specified shade/colour using hot thermoplastic material by fully/semiautomatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications including all carriages.
17Manufacturing supplying and fixing retro reflective overhead signage boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-III of ASTM-D-4956-01 as approved by Engineer-in-charge; letters, borders etc. as per IRC : 67-2001 in silver white with blue colour background and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class -II of ASTM-D-4956- 01 and fixing the same to the plate of structural frame work by means of suitable sized aluminum alloys, rivets or bolts and nuts @ 300mm c/c all along the periphery as well as in two vertical rows along with thef resistant measures including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminum sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawing, specification and direction of Engineer-in-charge (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment) including all carriages.
18Providing and fixing Glow studs of size 100x20mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (High impact Polystyrene) or ABS having electronically welded micro-prismatic lens with abrasion resistant coating as approved by Engineer-in-charge. The Glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro-reflective surface shall be 35 +/- 5 degrees to base. The reflective panels on both sides with at least 12cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS : 873 part 4 : 1973. The studs shall be fixed to the road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge including all carriages.
19Supplying and installation Yellow and Black Rubber Rumble Strip, onRoad
20Providing Route marker of Brass ,Including Providing, Placing and fixing with suitable mean on Site
21Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:
22Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materialAll kinds of soil :
231.5 to 3.0m
243.0 to 4.5m
25Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete
26250 mm dia. R.C.C. pipe
27300 mm dia. R.C.C. pipe
28Providing and constructingRCC manhole Size 1.2 M x 1.2 M upto a depth of 2 M excluding excavation including foundation concrete 250 mm thick and haunches and channels in C.C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 copingand fixing in position steel fibre reinforced concrete ( SFRC) Frame and cover (20 tonnes capacity) of approved make including loading, unloading, transportation, all taxes, etc complete as directed by Engineering-incharge.
29Providing and constructingRCC manhole Size 1.2 M x 1.2 M upto a depth of 3M excluding excavation including foundation concrete 250 mm thick and haunches and channels in C.C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 copingand fixing in position steel fibre reinforced concrete ( SFRC) Frame and cover (20 tonnes capacity) of approved make including loading, unloading, transportation, all taxes, etc complete as directed by Engineering-incharge.
30Providing and constructingRCC manhole Size 1.2 M x 1.2 M upto a depth of 4 M excluding excavation including foundation concrete 250 mm thick and haunches and channels in C.C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 copingand fixing in position steel fibre reinforced concrete ( SFRC) Frame and cover (20 tonnes capacity) of approved make including loading, unloading, transportation, all taxes, etc complete as directed by Engineering-incharge.
31Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete For pipes 100 to 250 mm diameter
32Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design
33uPVC pipes (working pressure 4 kg / cm2 ) Single socketed pipe metre110 mm dia
34Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
35Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in mouldings as in cornices, windows sills etc. including setting in cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and curing but excluding the cost of reinforcement with: 5.14.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
36Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete
37Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II(dia:110mm)
38Scarifying the existing bituminous road surface to a depth of 50mm and disposal of scarified material within all lifts and lead upto 1 km (by mechanical means).
39Dismantling dressed stone work ashlar face stone work, marble work orprecast concrete work manually/by mechanical means including stackingof serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:
40Providing and applying tack coat using hot straight run bitumen of grade – VG-10, including heating the bitumen, spraying the bitumen withmechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications.
41Providing and laying seal coat of premixed fine aggregate (passing 2.36mm and retained on 180 micron sieve) with bitumen using 128 kg ofbitumen of grade VG-10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling andfinishing with road all complete
42Providing and laying bituminous macadam using crushed stone aggregatesof specified grading premixed with bituminous binder, transported to siteby tippers, laid over a previously prepared surface with paver finisherequipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as perspecifications to achieve the desired compaction and density, complete asper specifications and directions of Engineer-in-Charge. 16.63.1 50 to 100 mm average compacted thickness with bitumen ofgrade VG-10 @ 3.5% (percentage by weight of total mix) prepared inBatch Type Hot Mix Plant of 100-120 TPH capacity.
43Providing and laying semi- dense Bituminous concrete using crushedstone aggregates of specified grading, premixed with bituminous binderand filler, transporting the hot mix to work site by tippers, laying withpaver finisher equipped with electronic sensor to the required grade, leveland alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. 16.64.1 25 mm compacted thickness with bitumen of grade VG- 10 @5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
44Providing, laying and making kerb channel 30cm wide and 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth etc. complete as per direction of Engineer-incharge.
45Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
46Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
47Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. LD - 2.5 Circular shape 450mm internal diameter
48Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C.horizontal grating with frame complete as per standard design: Chamber size 50x45x60 cm including precast R.C.C grating with frame 500x450 mm horizontal grating.
49Manufacturing supplying and fixing retro reflective sign boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity ncapsulated type heat activated retro reflective sheeting conforming to type-IV of ASTM-D-4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC : 67-2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminum alloy rivets @ 20cm c/c to back support frame ofM.S. angle iron of size 25x25x3mm along with theft resistant measures mounted and fixed with 2 nos. M.S. angles of size 35x35x5mm to a vertical post made upto M.S. Tee section ISMT 50x50x6mm welded with base plate of size 100x100x5mm at the bottom end and including making holes in pipes, angle flats, providing and fixing M.S. message plate of required size steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical M.S.-Tee support to be painted in black and white colours). Backside of aluminum sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coats including all leads and lifts etc. complete as per drawing, specification and direction of Engineer-in-charge.
50Mandatory/Regulatory sign boards of 900 mm diameter with part as length of 3750 mm.
51Cautionary/warning sign boards of equilateral triangular shape having each side of 900 mm support length of 3650mm.
52Providing andPlacing Stainless Steel Bollard in position 125 mm dia Bollards 1200 mm high of required shape including providing Stainless Steel125 mm dia 1200 mm long in the Bollard and stainlesssteel.long with 150x150x6 mm M.S. plate welded at bottom and embeded 150 mm in cement concrete 1: 3: 6 (1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing.
53Providing and fixing post delineators made of ABS round body fitted with 2nos. 100mm dia high reflective and reflectors and mounted on M.S. pipe of 65mm dia duly powder coated with anti-rust and anti-theft steel to be installed as per direction of Engineer-in-charge.
54Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc, including priming coat complete: Second Class Teak Wood
55Providing and fixing 20mm thick wooden planks ceiling (frame work for base to be paid for separately) with M.S. screws
56Supplying and installation Solar Traffic Blinker on Pedestrain crossing.
57Providing and fixing of Wooden Shingle roofing of first class kail wood excluding the cost of frame work which is to be paid separately complete job
58Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.
59Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing.One face dressed
60Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts,spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
61Electrical works
62Illumination
63Supplying and erecting street light Wall bracket (fancy wall bracket) made from 40 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete.job is in completer manner.
64Supplying and erecting LED street light fitting 150 W, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete
65Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete.
66Supplying, erecting & terminating XPLE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe
67Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
68Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
69Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation complete.
70Supplying and erecting Three phase smart energy meter DLMS compliance with 3x240V 50 cycles AC supply 10-60 A, ISI mark, accuracy class 1.0 with backlit LCD display, measuring & display V, I, kW, kWh, PF, kVA, kVAr, MD, day, week, month & with communication module configurable for GSM/Wi-Fi, IrDA/Bluetooth, complete provided panel with calibration certificate from manufacturer & duly wired with required size of PVC wires.
71Supplying & erecting FRP box of size 150 x 125 x 100 mm, 2.7 mm thick complete on pole/wall as per Direction.
72Cabling
73HT / LT
74Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Supply of of S.T. poles 9.0 Meter long swaged Type conforming to ST 540 SP-33,IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground levelincluding Aluminium Paint of approved brand with earthing arrangement through bolt welded on poleof 14mm diameter, provided at height of 300mm abovethe planting depth which should be 1.5ms(SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
75Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 8 Mtr. Long Pole(ST-540 SP15)IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level including Aluminium Paint of approved brandwith earthing arrangement through bolt welded on poleof 14mm diameter, provided at height of 300mm abovethe planting depth which should be 1.5ms(SP 15). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
76Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for Supplyof G.I U- clamps for LT Shackle insulators to be fixed without drilling/punching of poles on ST poles with pin.
77Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for Ch. Iron X-Arm 5"/6/7/8 Long (75*40)mm with G CLAMP and Brace including Red Oxide primer and Aluminium paint of approved brand.
78Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for Ch.IronX-arm including clamps & braces (GI) including Red Oxide primer and Aluminium paint of approved brand.
79Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. for 100 sq mm ACSR conductor with indian standard specification .
80Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of Supply of Supply of ACSR 50Sqmm conforming with the Indian Standard specification IS: 398 (PLI)-1976 and IS : 398 (PL II)- 1976 or the latest version thereof.(3 phase 4 wire).
81Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for LT Shakle Insulator with D- Clamps
82Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for PG Clamps for 0.05 ACSR Conductor, binding wire etc (1 Set=3 Nos.).
83Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for 11KV Pin insulators(Polymer Type) 12 KV ,5KN Complete with fittings..(Lighting Impluse 75 KV positive and 80 KV negative , crepage distance 320 mm) with pins.
84Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for 11KV Disc Insulators (Polymer Type) 12 KV ,45KN Complete with fittings..(Lighting Impluse 75 KV positive and 80 KV negative , crepage distance 320 mm).
85Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Galvinized Nuts and Bolts as per indian standard.
86Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Danger Plate With Clamps as per Standards wih writing in English & Urdu.
87Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Anti-Climbing Device with Clamps (GI Barbed Wire (12 SWG) for a distnce of 40 CM at hight of 3.5 meters from GL) , 3.50 Kg per pole.
88Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for Pole Earthing complete by G.I Pipe 40 mm or GI rod 20 mm , 2.5 mtr long through G.I Strip of standard size.
89Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc ofAluminiumJointing Sleves.
90Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc ofGuard Netting complete with earthingconnectionon both sides usingCradle guard wire 8 SWGGI wire and lashing of 10 SWG GI wire including GI x-armsas per REC Standards, with clamps and braces,threaded eye bolts, turn buckles and binding wire, nut boltsetc for span of 50 mtrs.
91Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete.
92Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of Extension Risers (GI) Ch. 75*40*6mm ,06 Feet long with V X-arm as per REC specifications.
93Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole.
94DT"S AND SUBSTATION
95Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Supply of of S.T. poles 9.0 Meter long swaged Type conforming to ST 410 SP-33,IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground levelincluding Aluminium Paint of approved brand with earthing arrangement through bolt welded on poleof 14mm diameter, provided at height of 300mm abovethe planting depth which should be 1.5ms(SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
96Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. for Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arrestor Set Heavy duty with Plymer Housing, Station type conforming to IEC-99-4 Capable of withstanding Maximum continuous operating voltages (M.C.O.V)
97Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. for11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) conforming: IS-2544, IS: 5340 (Part-III) and SS: 9921 (Part-I -V)
98Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of 11 KVHorn, Gap (fuse 3-phase 200A)as per Relevant IS.
99Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 1.1KV Grade PVC Insulated Stranded ConductorUn Armoured Sngle CoreXPLE FIRLS Type Cable 630mm2 Single Core.
100Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 1.1KV Grade PVC Insulated Stranded ConductorUn Armoured Sngle CoreXPLE FIRLS Type Cable 400mm2 Single Core.
101Supply, installation testing,and commissioning including labour, carriage, friegt, taxes, duties etc. ofGI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/HornGap.
102Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for 11KV Disc Insulators (Polymer Type) 12 KV ,45KN Complete with fittings..(Lighting Impluse 75 KV positive and 80 KV negative , crepage distance 320 mm).
103Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Galvinized Nuts and Bolts as per indian standard.
104Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. for TransformerPad/G.I Channel Bedding having bearing capacity 300Kg.
105Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for Earthing of Substation---Excavation of earth pit of dia 650mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm*3mm for connection of transformer body, G.O Set & lightening Arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials & earth chamber made of brick masonry with RCC slab cover.
106Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for 11KV Pin insulators(Polymer Type) 12 KV ,5KN Complete with fittings..(Lighting Impluse 75 KV positive and 80 KV negative , crepage distance 320 mm) with pins
107Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for LT Distribution Box for 630/400/250 kVA DTR with MCCB& SFU"s for Outgoing Circuits.
108Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for wedge connectors/PG Clamps.
109Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Danger Plate With Clamps as per Standards wih writing in English & Urdu.
110Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Anti-Climbing Device with Clamps (GI Barbed Wire (12 SWG) for a distnce of 40 CM at hight of 3.5 meters from GL) , 3.50 Kg per pole.
111Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of Sundry items like Aluminum lugs, Jumpers,Binding tape
112Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of Providing & Installation/ fixing of S.L. Clamps 630/400/ 300 sq mm
113Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc ofProviding & Installation/ fixingof Al. Thimbles 630/300/mm2.
114Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
115HT / LT AB CABLE
116Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 8 Mtr. Long Pole(ST-410 SP15)IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level including Aluminium Paint of approved brandwith earthing arrangement through bolt welded on poleof 14mm diameter, provided at height of 300mm abovethe planting depth which should be 1.5ms(SP 15). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
117Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of70 mm² AB (HT) Cable (3 x 70 + 95 mm²) .
118Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of120 mm² AB (HT) Cable (3 x 120 +1 x 95 mm²) .
119Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of120 mm² AB (LT) Cable ( 3 x 120 + 1 x 16 + 1 x 70 mm²) XLPE (1.1kV, 3+1 C, Al)
120Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Heat Shrinkable Outdoor Cable Termination Kit
121Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Suspension/Tension Clamp with eye hook
122Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Galvinized Nuts and Bolts as per indian standard.
123Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Danger Plate With Clamps as per Standards wih writing in English & Urdu.
124Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Anti-Climbing Device with Clamps (GI Barbed Wire (12 SWG) for a distnce of 40 CM at hight of 3.5 meters from GL) , 3.50 Kg per pole.
125Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for Pole Earthing complete by G.I Pipe 40 mm or GI rod 20 mm , 2.5 mtr long through G.I Strip of standard size.
126Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for Insulating Piercing Connectors.
127Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for PG Clamps.
128Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of Cement bottoming 1:2:4 mix as per REC standards .45cum/pole.
129Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Straight Through Joints.
130Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete.
131LT UNDERGROUNDING
132Supply,Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 400 mm² 3 1/2 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type( With 3-?, 1N, 1 Ckt spare) working voltage upto 11000 volt to be laid in cable duct complete in manner with necessary connection in an approved manner complete as required.
133Supply,Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 300 mm² 3 1/2 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type( With 3-?, 1N, 1 Ckt spare) working voltage upto 11000 volt to be laid in cable duct complete in manner with necessary connection in an approved manner complete as requried.
134Supply,Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 240 mm² 3 1/2 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type( With 3-?, 1N, 1 Ckt spare) working voltage upto 11000 volt to be laid in cable duct complete in manner with necessary connection in an approved manner complete as requried.
135Supply,Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 185 mm² 3 1/2 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type( With 3-?, 1N, 1 Ckt spare) working voltage upto 11000 volt to be laid in cable duct complete in manner with necessary connection in an approved manner complete as requried.
136Supply,Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 120 mm² 3 1/2 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type( With 3-?, 1N, 1 Ckt spare) working voltage upto 11000 volt to be laid in cable duct complete in manner with necessary connection in an approved manner complete as requried.
137Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Straight Through Joints.
138Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Route marker along the cable/cable duct bank in complete manner as per required
139Supply, Laying, Testing & Commissioning of warning Tap in complete manner asrequired
140Supply, installation testing,and commissioning including labour, carriage, friegt, taxes, duties etc. of Cable Termination Kits (indoor/outdoor). Heat Shrinkable type ( Indoor/Outdoor) termination along with necessary accessories to accommodate for single core400,300,250,185, & 120 mm2 ,3 1/2 Kv ( XLPE(E) aliuminum cable complete with all kit contents including earth continuity along with 3 Nos. crimping type aluminium lugs of suitable capacity including making joints etc. in an approved manner complete as required
141Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Earthing Complete. Earthing With G.I. Strip,G.I.earth pipe 4.5 meter long,40mm dia including accessories & providing masonry enclosure with cover plate having locking arrangment & watering pipe etc.with charcoal & salt as required.
142COMPACT SUBSTATION
143Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. Packaged Substation - 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV,400 kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with all interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3 way Non - Extensible RMU (breaking capacity 25kA for on second) with 2no. 630 A load break switch and 1 no. 200 A tee off with SF6 circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digital electronic meter, C.T"s etc. to complete as required to entire satisfaction of Engineer-in-charge. B) 1 no. 11 kV / 433V, 400 KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HT side , off lead tap, oil cooled type transformer with Cu winding an standard fittings. C) 1 No. 433V, 800A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 630A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp.each. Including 3phase 4 wire energy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves fromMain L.T Bus bar to each compartment of MCCB.
144Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties for Earthing of Substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mmx3 mm for connection of substation body as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
145Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties for wire mesh jali around the Packaged Sub-Station of size upto 8"x4" made out of wire mesh 1"x1"square including fixing in cement 1:2:4 including welding cutting etc. Complete in all respect.
146Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties for Excavation in any type of soil including hard laterite soil.
147Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties for Refilling of excavated soil.
148Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties for Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundations) icuding plastering
149FEEDER PILLAR
150Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc for 3 phase, 415V, 1no of 250 Amps incoming 3 TP MCCBs (Breaking 50KA) fitted with outgoing 03 No 100 Amps SP MCCBs, 1No.100Amps 3 pole MCCB for outgoing LT cables, Distribution feeder Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7-tank process with PU painted Busbars(6 mm thickness) 4P, Aluminium with heat shrinkable sleeves and adequate capacities complete with all accesories 12 way Distribution Feeder Pillar.
151Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 1 phase 2 wire, 415V, 1nos of 100 Amps incoming SP MCCBs fitted with outgoing 08 No 16 Amps SP MCBs for Service Connections, Distribution Service Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7-tank process with PU painted Busbars(4 mm thickness) 2P, Aluminium with heatshrinkable sleeves and adequate capacities complete with allaccesories 8 way Distribution Service Pillar with Kiosk Boxes for HousingDigital Energy Meters)for Distribution of Supply to consumers (8 way)
152Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Support Galvanised angle frame and legs (50 mm x 50 mm x 6 mm) for Distribution Feeder Pillar , leg height 1m with 0.3m in soil approx 7 m @ 4.50Kg per mtr. as per site condition in complete manner with cutting ,bending,fabrication as required in complete manner
153Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Support Galvanised angle frame and legs (50mm x 50 mm x 6 mm) for Distribution Feeder Pillar with leg height 1m with 0.3m in soil approx 7m@1.8Kg per mtr
154Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Earthing Complete Earthing With G.I. Strip,G.I.earth pipe 2.5 meter long,20mm dia including accessories & providing masonry enclosure with cover plate having locking arrangment & watering pipe etc.with charcoal & salt as required
155Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Cement grouting for support angle legs for LT fedder pillar as per approved drawing in complete manner as required
156Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 95mm² 2 Core, 1P2W Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type(1-?, 1N)
157Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 10 mm² Cable (2C) from LT Line tometer ,1.1k V Grade, Armoured, PVCInsulated Stranded Conductor FRLS type
158Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 1"/2"HDPE Conduits
159Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. ofExcavation in any type of soil including hard laterite soil
160Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of Cement grouting for HDPE Conduits
161Supply, Laying, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. ofReinstatement of Devri stones 100m*0.7m*0.5m
162DISMANTLING
163Dismantling of existing ACSR 100/50/30 SqmmLTandtransportation back to Divisional Stores. As per Instructions of Electrical Incharge.
164Dismantling of existing ACSR 100/50SqmmHTandtransportation back to Divisional Stores. As per Instructions of Electrical Incharge.
165Dismantling of existing PCC/Wooden Poleand transportation back to Divisional Stores. As per instruction of Electrical Incharge.
166Dismantling of existing ST pole 8/9 mtr and transportation back to Divisional Stores. As per instruction of Electrical Incharge.
167Dismantling of existing LT shakleInsulators with D clamps complete and transportation back to Divisional Stores. As per instruction of Electrical Incharge.
168Dismantling of existing Stone Masonary Pole Bed/Wooden Bed and transportation back to Divisional Stores. As per instruction of Electrical Incharge.
169Dismantling of existing Ch.Iron V-X arm, X-arm including clamps & braces (GI)
170Dismantling of existing 11 kV Pin Insulators complete and transportation back to Divisional Stores. As per instruction of Electrical Incharge.
171Dismantling of existing 11 Disk Set and transportation back to Divisional Stores.As per instruction of Electrical Incharge.
172Providing Air Conditioned Vehicle (Scorpio, Bolero, Innova and like) in good condition for site supervision along with driver, service, amintenance, fuel etc (max upto 1500 Km/month)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail