| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-04-2023 | Date Extend | Date | 13-04-2023 |
| Sl. No. | Item Description |
| 1 | Excavation in foundation in ordinary soil (Loam clay or sand) including lift up to 1.5 M and lead upto to 30 M and including filling watering and ramming of excavated earth in to the trenches or into the space between the building and sides of the foundation Work . |
| 2 | Clearing jungle including uprooting of rank vegetations,grass, bush,wood, trees and saplings of girth upto 30cm measured at a height of 1.0m above ground level and removal of rubbish upto a distance of 50m outside the periphery of UPPCL area cleared. |
| 3 | Levelling and dressing and making proper slope including cutting and filling of earth upto a depth 100 mm if so required including all labour T&P etc. required for proper completion of the work. |
| 4 | River Bed fine Sand filling in plinth including supply of necessary quantity of fine sand from outside the UPPCL premises including watering, dressing etc. Rate to include cost of all materials, labour and T&P etc. required for proper completion of work. |
| 5 | Earth filling under floors and/or corporation area including cost of earth obtainedwith in 8 km distance outside corporation area including all taxes (if any) andits carriage including watering, ramming in 20 cm layers and dressing of earth etc. all complete. |
| 6 | Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion of the work. |
| 7 | Concrete with 4cm gaugestone ballast, coarse sand(F.M. 1.8 to 2.5) and cement in proportion of 8:4:1 in foundation & under floors including supply of all materials, labour & T&P etc. complete. |
| 8 | Cement concrete with 2cm gauge approved hard stone ballast,coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 4:2:1including supply of all materials, labour,side shuttering ifrequired and T&P etc. required for proper completion of work. |
| 9 | Concreting of 40 mm thick RCC trench covers in mild steel framework with RCC 1:1.5:3 in Cement,Chopan coarse sand(F.M. 1.8 to 2.5) and 2cm gaugegraded hard stone ballast with 3mm thick floating coat of neatcement finish on top of cover complete with all labour, materials and placing the same in proper position at required location of cable trench within the substation area. |
| 10 | Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in item no. 6 includingcost of all labour,materials, T&P etc required for proper completion of work. |
| 11 | Cement concrete with 2cm gauge approved hard stone ballast,coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 3:1.5:1including supply of all materials, labour,side shuttering ifrequired and T&P etc. required for proper completion of work |
| 12 | RCC work with cement, approved coarse sand(F.M. 1.8 to 2.5) and2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3in lintels of doors and windows, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P. |
| 13 | RCC work with cement, approved coarse sand(F.M. 1.8 to 2.5) and2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3inslab, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P |
| 14 | RCC work with cement, approved coarse sand (F.M. 1.8 to 2.5) and2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3inlighter beams i.e. having span upto6m, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P . |
| 15 | RCC work with cement, approved coarse sandand2 cm gauge graded approved hard stone ballast like granitet, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3in heavier beams i.e. having span above6m, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P . |
| 16 | RCC work with cement approved coarse sand(F.M. 1.8 to 2.5) and2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from Dalla, Jhansi or other quarries and approved coarse sand in proportion1:1.5:3 in raft foundation and footings , excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P. |
| 17 | RCC work with cement approved coarse sand (F.M. 1.8 to 2.5) and2 cm gauge graded approved hard stone ballast like grainite, quartzite etc from Dalla, Jhansi or other quarries and approved coarse sandin proportion 1:1.5:3in RCC pile caping, gantry walls/columnfoundations and RCC pedestals , excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P . |
| 18 | RCC work with cement, approved coarse sandand2 cm gauge graded approved hard stone ballast like granite, quartzite etc from Dalla, Jhansi or other quarries in proportion 1:1.5:3in RCC T beam-slab and column, excluding supply of reinforcement & its bending but including its fixing and binding the same with binding wire, including cost of all other materials labour and T&P . |
| 19 | First class brick work in 1:6 cement and coarse sand(F.M.1.8 to 2.5) mortar in foundation and plinth including supply of allmaterials, labour & T&P etc. required for proper completion of work. |
| 20 | First class brickwork in 1:4 cement and coarse sand (F.M. 1.8 to 2.5) mortor in foundation and plinth including supply of all materials, labour & T&P etc. required for proper completion of work. |
| 21 | Add to item 19 to 20 above for extra labour in super structure including necessary cutting and moulding of bricks as required and also including honeycomb brick work, thickness of wall not to be less than 1.5 brick. |
| 22 | As in item 21 above but for walls of one brick thickness.Add for extra labour to the rates of item No.21. |
| 23 | As in item 21 above but for walls of 1/2 brick (115 mm)thickness, add for extra labour to the rates of item Nos. 21. |
| 24 | Brick work in foundation & plinth with old dismantledbricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. |
| 25 | Removal of cement mortar from dismantled bricks and stacking in countable position at place as directed by the Engineer in charge, including cost of all labour and T&P required for proper completion of work. |
| 26 | Supply and filling brick bat in soak pit including all labour,material and T&P etc complete. (for 01 soak pit) |
| 27 | 2.5 cm. thick damp proof course of cement concrete consisting of 1 part cement 1.5 parts approved coarse sand (F.M.1.8 to 2.5), and3 parts approved 12 mm. graded stone grit and also including liquidwater proofing material as approved by the Engineer-Incharge in the proportions specified by the manufacturer. |
| 28 | Supply and fixing of 32 mm thick single leaf flush door shutter ( boiled water resistance, phenol maldehide resin bonded, hot pressed factory made) commercial quality to I.S.2202 part-1 (1983) ISI marked including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges,bolts.locks,handles, springs and other fittings but excluding their supply including all materials,labour & T&P etc. required for proper completion of work. |
| 29 | Fixing of Departmental doors & windows shutters including supply& fixing of hinges and other fixtures.(excluding their supply) including all materials,labour & T&P etc. required for proper completion of work. |
| 30 | P/F fully Anodized aluminium fixed glazing with HINDALCO or equivalent extruded standard sections14gauge (2.41mm thick) of various cross sections and joints mitred and jointed as shown in drawingincluding providing & fixing 5.5 mm thick toughened glass with Neoprene beading & aluminium glazing clips all around. The minimum thickness of anodizing on all aluminiumsections should be 20 microns with a (+) 2 microns tolerance . The rate should include the cost of fixing the aluminum frame on Teak wood frame or finished wall (RB/RCC/Masonry) surface by means of 80 mm long approved counter sunk screws provided at 500 mm c/c or part there of starting from 100 mm above the bottom in vertical member and 100 mm from both the ends of horizontal top and bottom member excluding cost of Teak frame but including cost of all other material, labour, tools & plants etc. complete. |
| 31 | Supply and fixing brass polished hydraulic door closure of approved make & quality its fixing and adjustment with the help of screws, nuts and bolts including supply of all labour, T & P etc. required for proper completion of the work. |
| 32 | Mild Steel or Iron work in heavy sizes such as trusses built upgates, door frames, record, racks roof work gates etc. wrought torequired form including holes rivetting or welding where necessary and also fixing in proper position and alignment including cost of all materials supplied by contractor. |
| 33 | TMT/Tor steel in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage, bend, hooks and authorised overlapping shall be measured. (steel shall be arranged by the contractor. |
| 34 | Providing barbed iron wire fencing including fixing in postafter straightening it including labour and T&P etc. requiredfor proper completion of the work but excluding supply of postsand wire.(labour rates only) . |
| 35 | Dismantling existing barbed wire fencing including making bundlesand stacking etc.complete.(labour rates only) . |
| 36 | Providing and Fixing barbed iron wire fencing including stretching, fixing into the post including all labour, materials and T&P required for proper completion of work. the weight of hot dipped GI barbed wire having 12 SWG - 2 ply wires and 4 point ordinary barbs @ 150 mm (approx) C/C should be 100 gm per Meter. |
| 37 | Supplying and fixing rolling shutters of approved make made of 80x1.25 mm. Gauge cold rolled M.S. lathes inter locked through out their inner length and joined together at the end by end lock guides & arrangements for inside and outside locking with push &pull operation complete but excluding the cost of top cover and springs. |
| 38 | P/F 27.5cm. long wire spring grades 2 forrolling shutters. |
| 39 | Providing and fixing top cover rolling shutters. |
| 40 | Providing & fixing ball bearing for rolling shutters. |
| 41 | Supply of 28 mm. dia M.S. Anchor bolts (conforming to IS 266)900 mm. long with base plate (75x75x6mm) welded with anchor boltsincluding its threading upto a length of 10cm. and also supplyof a pair of galvanized standard nuts with threading including supply of 5 mm thick washer and cost of labour, material & T&P for proper completion of work. |
| 42 | Fixing and grouting28 mm and above dia bolts in properalignment level and setout with help of a template completeincluding supply of all labour & T&P etc. required for propercompletion of the work.(labour rates only) . |
| 43 | Supplyof 25 mm dia.M.S. Anchor bolts (conforming to IS-226) 500 mmlong with base plate(50x50x6 mm)welded with anchor bolts,including its threading upto a length of 10cm. and galvanizing upto 15cm from top, also supply of a pair of galvanized standard nuts with threading including supply of 5mm thick washer and cost of labour material and T&P etc. required for proper completion of the work. |
| 44 | Fixing and grouting 25 mmand below dia M.S. Anchor bolt in proper alignment level and setout with the help of a template including supply of all labour T&P etc. reqd. for proper completion of the work. (labour rates only) . |
| 45 | Providing and fixing steel glazed window and ventilators ofstandard rolled Mann or Mahavir steel sections conforming to IS7452-1974 as per drawing joints metered & welded with 100x14x3.15 mm holdfast embedded in cement concrete block 15x10x10 cm. Size of 1:3:6 proportion i.e. 1 part of cement 3 part of approved coarse sand & 6 part of graded stone (aggregated 20mm. Nominal size) S/F of glass panes of plain pin headed 4mm. Thick nuts glazing clips and special putty of approved make complete and including a cost of red oxide paint. The fabrication should conform to I.S.1038-1975. (Aluminum beading with rubber packing included). |
| 46 | Fixing of Pale fencing alongwith horizontal runner and pales with6 mm dia. 30 mm long galvanized iron bolts and nuts with washerin true alignment and level between the vertical post alreadygrouted as per direction of I/C. |
| 47 | Supply and fixing galvanised mosquito proof jali (16x24 gauge) withM.S. flat of 20 x 3 mm. size, on both sides screwed or welded to windowor door frame. |
| 48 | Providing M.S. Frames work for R.C.C. Trench covers and edging with M.S. Angles including cutting, bending and welding ofM.S. Angle and cutting and welding of M.S. bars for reinforcementand lifting hooks as per approved design. The rate is includingcost of all labour, materials etc. as required for proper completion of the work. |
| 49 | S/F welded wire mesh size 75x25mm and rectangularmade out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labourand T&P etc. required for proper completion of work . except cost of M.S angle and flat. |
| 50 | S/F 50x50mm, 8 gauge G.I. chain link fencing 1.8 Mhigh including fixing to vertical posts, horizontal runners with 10mm dia.40mm long bolts, nuts and washers complete with all material, labour and T&P etc. required for proper completion of work. Chain link of 8 gauge shall be galvanized by hot dipped method as per relevant IS Code. (Excluding cost of vertical posts and horizontal runners) |
| 51 | As per item No 50 above but excluding the cost of G.I.chainlink ( Fixing charges only). |
| 52 | Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C (Labour rate only). |
| 53 | Grouting of vertical or inclined post of pale/chain/security fencing in truelevel, alignment and in plumb or inclination as required,including cost of all labour, materials and T&P required forproper completion of work. ( Post and concrete for grouting shall be measured separately) |
| 54 | Fixing of template in position level and alignment for groutingof Anchor bolt in main gantry (labour rate only). |
| 55 | Fixing of template in position level and alignment for groutingof Anchor bolt in auxiliary structure. (labour rate only). |
| 56 | Fabrication of template for main gantry foundation including cost of all labour, and T&P etc. required for proper completion of the work. Steel shall be arranged by contractor free of cost. This template shall be property of contractor.(Labour rate only). |
| 57 | Fabrication of template for Auxiliary gantry foundation including cost of all labour, and T&P etc. required for proper completion of the work. Steel shall be arranged by contractor free of cost. This template shall be property of contractor.(Labour rate only). |
| 58 | Providing & fixing 1 mm.thick M.S. sheet garrage door with frameof 40x40x6mm angle iron,diagonal bracings with 50x5 mm flat and 5 mm thick M.S. gusset plates at thejunctions and corners including supply and fixing of necessaryfitting, 2 no lock rail of 16 dia,375 mm long and including pintel hooks at the top and bottom, applying a priming coat of red oxide paint on all sides complete . |
| 59 | P/F Concertina coilfencing with required dia. 600 mm upto 3 M height of wall between existing angle iron ‘Y’ shaped placed 2.4 M or 3.0 M apart and with 6 horizontal R.B.T. stud tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron all complete ( No. of rounds will be 7 to 8 in one Meter length) as per direction of Engineer I/C with reinforced barbed tape (R.B.T.)/ Spring core (2.5mm thick ) wire of high tensile strength of 165 kg/Sqmm with tape ( 0.52 mm thick ) of supreme make or equivalent and weight 43.478 gm/meter ( cost of MS angle, C.C. blocks shall be paid separately). |
| 60 | Fixing of cable trench racks in proper position and alignment including cost of all labour, material and T&Petc. required for proper completion of the work (Labour rate only). |
| 61 | 12mm thick plaster with cement mortar inproportion 1:4 cement and coarse sand of 1.8 to 2.5 fineness modulus over brick work minimumthickness not to be less than 10 mm including supply of allmaterials, labour and T&P etc required for proper completion ofthe work. |
| 62 | Add for extra labour to all items of plaster if done in ceiling. |
| 63 | Add for extra labour and materials for plaster over rough face ofone brick thick wall. |
| 64 | 6 mm. thick plaster with 1:3 cement & coarse sand includinglabour, materials & T&P etc. required for proper completion ofthe work. |
| 65 | S/mixing approved water proofing compound (CICO,DR FIXIT etc) in cementmortar in plaster or concrete work in the proportion as recommended by the manufacturer. |
| 66 | Providing (12x15) mm section groove in plasterincluding all material, labour andT&P etc. required for proper completion of the work. |
| 67 | Champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & T&P etc complete. |
| 68 | Making drip coarse (25x12) mm in 1:2 cement and coarse sandincluding supply of all materials, labour and T&P etc requiredfor proper completion of work. |
| 69 | 3mm thick floating coat of neat cement finish including supply of all materials, labour and T&P etc. required for proper completion of the work. cement consumption 0.044bag/Sq.m. |
| 70 | Painting or varnishing new iron work in small areas or new woodwork with two coat of ready mixed priming paint and two coat ofapproved superior quality ready mix paint \"Luxol\" or equivalentbrand or varnish including supply of all materials, labour andT&P etc. required for proper completion of the work. Paint to beused should conform to the I.S. 103-1950. |
| 71 | As in item 70 above but for every coat on previously paintedold wood or iron work including its sand papering,rubbing andcleaning as required, for proper completion of work. |
| 72 | Painting letters & number over cable trench cover or other places with the help of stencils including painting of base of 150 mm. dia of one coat of primer and two coats of superior quality synthetic enamel paint size of letter to be 60 mm. x 10 mm. including cost of all materials labour and T&P etc. required for proper completion of the work including placing of Trench covers in required position. |
| 73 | 2.5 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specifiedand removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work.Without base cc . |
| 74 | 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work.Without base cc |
| 75 | Straight over burnt bricks on edge floor laid dry, joints sand filled,including preparation of base to proper slope and its rammingincluding supply of all material labour & T&P etc. required forproper completion of the work. |
| 76 | Providing and fixing glass strips of 3.15 mm thickness & 25mm depth in jointsof floor and skirting at the time of laying floors, flush withfloor level including supply of all materials, labour& T&P etc.required for proper completion of work. |
| 77 | Providing and laying floor of 8 mm thick vitrifiedtiles in flooring or skirting of approved brand (Bell, Johnson or equi. make)size of 600x600 mmof approved shade, colour and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cementmixed with pigment to match the shade of tile including cost of all material, labour and T&P required for proper completion of the work. |
| 78 | Same as 77 above but for providing and fixing 8 mm thick vitrifiedtiles in flooring or skirting with adhesive of approved quality on existing smooth floor including cost of all material, labour and T&P required for proper completion of the work. |
| 79 | Providing and laying of 16 mm thick granite ( black/ brown) inflooring or skirting ,of approved shade, colour,size and pattern , laid over base cement mortar 1:4 mix including finishing the joints with white cementmixed with pigment to match the shade of granite floor including cost of all material, labour and T&P required for proper completion of the work, as per direction of Engineer incharge. |
| 80 | S/F 10mm thick Group 25 acid resisting tiles of “Somany” or equivalent approved make in flooring or skirting (confirming to I.S. 4457 - 1967) in ordinary Portland cement and coarse sand in ratio 1:3 with the joints filled with acid resistant cement “Accocide” of A.C.C. or equivalent make acid resistant cement and liquid supplied with cement, mixed in 1:3 ratio to make a workable paste in G.I. Tray. The joints should be kept as 5mm and to be cured for 7 days with dilute HCL (One part acid and three parts of water). Rate should be including the cost of all materials, labour and T&P etc. required for proper completion of the work. |
| 81 | Supply of 80 mm thick I shaped mechanically compressed inter locking cement concrete paver block manufactured by high pressure & controlled vibration machine having plan dimension 200X(160+120 mm) with minimum 5 mm thick toping of O.P.Cement mixed with 25% marble powder. The compressive strength of concrete pavers blocks shall not be less than 30 MPa & 4.5 Kg/No. including cost of all material, labour, T&P etc. required for proper completion of work as directed by Engineer-in-charge but excluding G.S.T. which shall be paid extra as per rules. |
| 82 | Supply and Laying 6 mm thickglazed tiles in skirting / dado laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete,including supplyof all materials, labour and T&P etc. completion required for proper completion of the work. |
| 83 | Placing of trench cover of all size in proper position includingtransportation from different places within the S/S areaincluding all labour, T&P etc. required for proper completion ofthe work as per direction of Engineer- in-charge. |
| 84 | Applying Birla or equivalent putty on new interior or exterior surface over one coat of water based cement primer of ICI or equivalent brand for smoothening and levelling of the surface as per requirement and direction of Engineer I/C including cost of all material, labour, T & P etc required for proper completion of work. |
| 85 | Applying BIRLA PUTTY or equivalent putty on previousaly bila putty smoothen surface over one cost of water base cement primer of ICI or equivalent brand for smoothining and leveling of the surface as per requirement and direction of E/I including cost of all material , labour and T&P required for proper completion of work. |
| 86 | Painting one coat with APEX or equivalent brand weather coat paint on new wall surfaces (well prepared with Birla putty and one coat of primer ICI or equivalent which shall be paid separately) including through washing with water including cost of all materials, labour, T&P required for proper completion of work. |
| 87 | Same as in item no 86 above but for every coat of additional APEX or equivalent brand weather coat paint . |
| 88 | Dismantling brick work or stone work in lime or cement mortar andincluding stacking of materials as directed by theEngineer-in-charge within a distance of 60 metres. |
| 89 | Dismantling reinforced cement concrete or reinforced brick work,including stacking of dismantled materials as directed by theEngineer-Incharge within a distance of 60 metres. |
| 90 | Dismantling cement concrete or brick or granolithic floorsincluding base concrete and including stacking of dismantledmaterials as directed by the Engineer In-charge within a distanceof 60 metres. |
| 91 | Dismantlingstone flagged or tiled floorincluding base concrete and including stacking of dismantledmaterials as directed by the Engineer In-charge within a distanceof 60 metres. |
| 92 | Dismantling corrugated iron & asbastas roof sheet andstacking of materials as directed by Engg-in-charge within a distance of 60 mtrs. |
| 93 | Dismantling of griders, trusses and other steel works including stcking of materials as directed by Engg-in-charge within a distance of 60 mtrs. |
| 94 | Dismantling existing plaster including disposal of refuse asdirected by the Engineer-I/C within a distance of 60 M. |
| 95 | Scrapping old white or colour wash or distemper including disposal of refuseas directed by the Engineer-I/C within a distance of 60 M. |
| 96 | Dismantling of existing pale / security / chain link fencingincluding post and stacking properly as per direction of theEngineer - in - charge. Including all labour and T&P etc.required for proper completion of the work. |
| 97 | Dismantling and re-laying of dry B.O.E. floor including cost of all labour and T&P required forproper completion of work.(labour rates only) |
| 98 | Pre-Construction anti-termite treatment, by creating a barrier under and around the columns pits, foundation trenches, under floors, junctions of Walls &floors, around the external perimetre of building, expansion joints, surrounding of pipes and conduits etc. (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981))with Eldrine emulsifiable 0.2% concentration or any other approved material such as Heptachlore or chlordance will be used. The consumption of emulsion shall be (i) Foundation and masonary @ 5 Ltrs/Sqm, (ii) Back fills in immediate contact of foundation@ 7.5 Ltrs. / Sqm, (iii) Top surface of Plinth filling @ 5 Ltrs / Sqm, ( iv) Junction of walls & floors @ 7.5 Ltrs / Sqm, (v) Soil along external perimetre of building @ 7.5 Ltrs / Sqm (vi) under apron of the building @ 5 Ltrs. /Sqm. The rates includes cost of all materials, labour, equipments, T&P complete. |
| 99 | Laying cement concrete road slabconsisting of 1 part cement 1.5 part approved coarse sand and 3 part approved 20mm down graded stone aggregate over prepared sub grade after its rectification and bringing it to proper camber and shape,finishing with TRIMIX machine ,concrete hardner and making good to the satisfaction of E/I inclduing cost of all materials, labour and T&P etc. required for proper completion of the work. |
| 100 | Filling of 20 mm. wide 100/150 mm. deep joint with coarse sand and saw dust mixed with hot bitumen etc. complete including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 101 | Providing and fixing 12mm thick particle board of commercial quality 125 mm deep for making partitions of C.C. road slab as per direction of E/I. including cost of all material, labour and T&P required for proper completion of work. |
| 102 | Disposal of rubbish / debris out side the UPPCL area as per direction of Er/in- charge including cartage, labour and materials, T&P etc. required for proper completion of the work. (No. deduction for voids shall be made). |
| 103 | S/laying chicken mesh of (20 mm.)hexagonal heavy quality over roofs of joints of roof as per direction of the Engineer - in - charge. |
| 104 | S/F full way63/65 mm dia Fire hydrant Gun Metal Gate Valve heavy quality including supply of all labour , material andT & P for proper completion of work . |
| 105 | Wiring point for light with 1.5 sq. mm FRPVC insulated multistrand single core copper conductor cable in PVC Conduit with 1.5 Sq. mm. FRLSH PVC insulated multistrand copper conductor cableas earth wire drawn inside the PVC conduit pipe concealed in the wall, modular type switch and ceiling rose/ angle /batten holder on 3mm thick phenolic laminated backelite sheet etc, complete in all respects, as directed, including matching colour wash. |
| 106 | Wiring point for fan/fresh air fan with 1.5 sq. mm FRPVC insulated multistrand single corecopper conductor cable as earth wire draw inside the PVC conduit pipe concealed in the wall, complete with 14 SWG copper earth continuity wire, Modular type switch and ceiling rose/ angle/ batten holder on 3mm thick phenolic laminated backelite sheet etc,complete in all respects,as directed,including matching colour wash . |
| 107 | Wiring point for plug with 1.5 sq. mm FRPVC insulated multistrand single core copper conductor cable inside the PVC conduit pipe concealed in the wall, complete with 14 SWG copper earth continuity wire, Modular type switch and Socket etc,complete in all respects,as directed,including matching colour wash. |
| 108 | Wiring point for exhaust fan with 1.5 sq. mm FRPVC insulated multistrand single core copper conductor cableas earth wire draw inside the PVC conduit pipe concealed in the wall, complete with 14 SWG copper earth continuity wire, modular type switch and ceiling rose on 3mm thick phenolic laminated backelite sheet etc,complete in all respects,as directed,including matching colour wash. |
| 109 | Supply and fixing and concealing of 20mm dia 2 mm thick PVC conduit pipe with ISI marked embossed and with PVC accessories confirming to IS 3419 for drawing wires duly sealed at joints original resin/adhesive to make the complete piping rigid, plastering with cement sand mortor finished to the level with matching colour wash including supplyof all materials, labour and T&P etc.required for propercompletion of the work. |
| 110 | Supply and fixing of 2/3/4 ways round steel junction box confirming to ISS for 20mm dia 16 guagethick conduit concealed in wall, keeping its level upto plaster duly provided with proper size cover screwed as directed at site by Engineer-in-charge with supply of all material, labour & T&P etc. required for proper completion of work. |
| 111 | Supply and fixing of 2/3/4 ways round steel junction box confirming to ISS for 25mm dia 16 guagethickconduit concealed in wall, keeping its level upto plaster duly provided with proper size cover screwed as directed at site by Engineer-in-charge with supply of all material, labour & T&P etc. required for proper completion of work. |
| 112 | Supply and fixing of switch box 100x100x65 mm size of Approved make made up 1.0 mm thick ISI Marked G.P. Sheet All 4 corner Folded & spot welded for screw And holesplugged with PVC nylon caps.Two or more holes for pipe entry of 25.4mm on upper and lower sides of the box. Holes should be semi shuttered type And fitted with heavy brass earth piller duly Screwed & brand name shoold be embossed . Box flushed in wall including Cutting of brick work, fixing it to the level with cement sand mortar including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the E/I. |
| 113 | Supply and fixing of switch box 200x250x65 mm size of Approved make made up 1.0 mm thick ISI Marked G.P. Sheet All 4 corner Folded & spot welded for screw And holesplugged with PVC nylon caps.Two or more holes for pipe entry of 25.4mm on upper and lower sides of the box. Holes should be semi shuttered type And fitted with heavy brass earth piller duly Screwed & brand name shoold be embossed . Box flushed in wall including Cutting of brick work, fixing it to the level with cement sand mortar including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the E/I. |
| 114 | Supply and wiring of submains with 2 nos. 2.5 sq.mm & with 1 no earth wire of 1.5 sq.mm FR PVC insulated 1100V grade insulated multistrand single core copper conductor cable in existing PVC conduit pipe complete,including supplyof all materials, labour and T&P etc.required for propercompletion of the work. |
| 115 | Supply and wiring of submains with 2 nos. 4 sq.mm & with 1 no earth wire of 2.5 sq.mm FR PVC insulated 1100V grade insulated multistrand single core copper conductor cable in existing PVC conduit pipe complete,including supplyof all materials, labour and T&P etc.required for propercompletion of the work. |
| 116 | Supply and wiring of submains with 2 nos. 6 sq.mm & with 1 no earth wire of 4 sq.mm FR PVC insulated 1100V grade insulated multistrand single core copper conductor cable in existing PVC conduit pipe complete,including supplyof all materials, labour and T&P etc.required for propercompletion of the work. |
| 117 | Supply and fixing of 32 Amp.240 V DP metal clad rewireable type switch fuse unit on MDFEG/Teak wood board including making connections etc.complete all respect. |
| 118 | Supply and fixing of 63 Amp.415 Vmetal clad rewireable type switch fuse unit on angle iron bracket including making connections etc.complete all respect. |
| 119 | Supply and burying of 600 x 600 x 3 mm copper plate vertically for earthing with its top at least 3 mtr. below ground level complete with 20 mm dia G.I. Pipe and funnel for watering and one earthing lead of one no. 8 to 10 S.W.G. copper wire in 15 mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. Pipe and copper wire will be extra) 30 cm sq. C.I. frame with hinged cover masonary housing alternate layer of charcoal /coke & salt at least 150 mm thick alround etc.complete in all respects. |
| 120 | Supply and fixing of 0.5 to 5.0 Amp. SP MCB (10KA c curve) of approved make including making connections etc.complete all respect. |
| 121 | S/F of 6/10/16/20/25/32 Amp. MCB(10KA c curve) of approved make and as per sample approved by E/I (10KA c curve) |
| 122 | Supply and fixing of 40 Amp. SP MCB(10KA c curve) of approved make including making connections etc.complete all respect. |
| 123 | S/F surface/flush mounting 4 ways SPN distribution board without MCB complete in all respect as per direction of E/I. |
| 124 | S/F hexagonal/Round G.p.fan box Of Approved make made up of 1.00mm thick ISI Marked G.P. Sheet spot welded four to eight holes of 25.4mm for pipe entry of the box . holes should be semi shuttered type with 0.5mm G.P. Sheet made upper & Lower cover duly ScrewedFitted with 300mm round zink coted M.S. Bar X12 mm & brand name should be empossed.Fixing with wiring conduit laid in the R.C.C. Roof before concreting alongwith supply ofall materials labour and T&P etc. required for proper completion of work. |
| 125 | Providing and fixing 15 mm dia B-class Jindal,JTC, ISI marked G.I. pipes complete with special such as bend, tee, socket, cross, clamp etc earth work including filling the trenches etc required for proper completion of the work. the rate also includes concealed GI fitting where required, cutting and making good the walls etc and all materials, labour and T&P complete. |
| 126 | (B) Same as above but for 20 mm dia. |
| 127 | (C) Same as above but for 25 mm dia. |
| 128 | (E) Same as above but for 40 mm dia. |
| 129 | (F) Same as above but for 50 mm dia. |
| 130 | (G) Same as above but for 65 mm dia. |
| 131 | (H) Same as above but for 80 mm dia. |
| 132 | Providing & fixing half turn 25mm dia gate valve, ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. |
| 133 | Providing & fixing half turn 40mm dia gate valve, ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. |
| 134 | Providing & fixing half turn 50mm dia gate valve, ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. |
| 135 | Providing & fixing half turn 65mm dia gate valve, ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. |
| 136 | P/FBRASS BIB COCK, 15 mm dia (400 gsm) ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. |
| 137 | Supply and fixing of 15 mm dia CI/ PVC bib cock including replacing of old bibcock complete. |
| 138 | P/F BRASS STOP COCK, 15 mm dia ISI mark heavy quality including supply of all materials, labour and T&P required for proper completion of work. |
| 139 | Providing and fixing 550X400 mm wash hand basin of white glazed earthern ware first quality I.S.I. marked (Hindustan,Neycer / Cera make) including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 140 | Providing and fixing 10 litres low level PVC flushing cistern, COMPLETE WITH ALL FITTINGS including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 141 | Providing and fixing in position 32 mm. dia P.V.C. flush pipe. for W.C. with unions, bends etc. including supply of all materials,labour and T&P etc.required for proper completion of the work. |
| 142 | Providing and fixing in position 32 mm. dia P.V.C.WASTE PIPE FOR WASH BASIN. including supply of all materials,labour and T&P etc.required for proper completion of the work. |
| 143 | Supply and fixing CP Nahani Trap India make of heavy approved quality complete with CI grating,includingsupply of all materials,labour and T&P etc. required for proper completion of the work. |
| 144 | Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work.110mm dia |
| 145 | Applying two coat Tapcrete mixed with White Cement and water to proper consistany on leaky surface including supply of allmaterials, labour etc. required for proper completion of work. |
| 146 | Cleaning of existing pipe line of different dia. ranging from 4\" to 2\" dia. including digging trenches and refilling, opening of pipes, cleaning of pipes, cutting, threading, if required fixing and including making good the road, wall etc as directed by the engineer I/C. |
| 147 | Cleaning of existing water pipe line of different dia up to 2\" dia including digging trenches and refilling,opening and cleaning of pipes,cutting,threading,if required fixing and including making good the road and wall etc. as directed by the Engineer in charge. |
| 148 | Cleaning of R.C.C. over head tank up to capacity of one lac. Liters and chlorinating with bleaching power mixed to water as per direction of Engineer - in - charge complete. |
| 149 | Making water connection of GI pipe line with GI Mains ( 25 mm to 100 mm ) dia. by providing and fixing Ferrule (25 mm dia) GI union and nipple including cutting and threading the pipe, inspection, testing, cutting and making good the road, executing bond with Nagar maha palika, fixing of pipe line upto the points near the building complete work including supply of all materials, labour and T&P etc. required for proper completion of work. |
| 150 | Supply and fixing of Syntex or equivalent make water storage tank including all materials, labours, T&P etc required for proper completion of work. |
| 151 | Providing and fixing first quality white glazed \"Orissa\" pattern W.C.Pan Hindustan, Cera make. size 580 mm.(Hindustan,Cera Make) with out \"P\" trapincluding supply of all materials,labour and T&P etc.complete. |
| 152 | Providing and fixing 600 mm x 450 mm beveled edge mirror of Atul,Kiran makeglass with Indian polish 6.50 mm thick complete with back of 600 mm x 450 mm x 6 mm hard board sheet fixed to wooden cieats with C.P. brass screws and washers including supply of all materials, labour and T&P etc.required for proper completion of the work. |
| 153 | Providing and fixing soap dish chromium plated with brackets fixed to wooden cleats with brass screws including supply of all materials,labour and T&P etc.required for proper completion of the work. |
| 154 | Providing and fixing 750 mm x 20 mm size C.P. brass towel rail of approved qualityincluding bracketsincluding supply of all materials,labour and T&P etc. required for proper completion of the work and cutting and making good the wall plaster etc. required for work. |
| 155 | Providing and fixing 100 mm dia white glazed \"P\" or \"S\" trap including cement concrete and all materials, labour cartage T&P etc.required for proper completion of the work.(For W.C.) |
| 156 | Providing and fixing Stainless Steel sink 610x450x200 mm Heavy Quality( ISI MARKED ) includingall materials, labour cartage T&P etc.required for proper completion of the work. |
| 157 | Providing and fixing of 110 mm dia PVC pipe 6 Kg/ Sq.cm forwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. |
| 158 | Providing and fixing of 110 mm dia PVC pipe 4 Kg/ Sq.cm forwith special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy