Tender For Various Electric Works On Turn-Key Basis For Electrification And Strengthening Of Infrastructure Due To Extension Of Nagar Nigam Area Eudd-1 Aligarh, aligarh-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Tender For Various Electric Works On Turn-Key Basis For Electrification And Strengthening Of Infrastructure Due To Extension Of Nagar Nigam Area Eudd-1 Aligarh. Submission Date for this Tender is 31-03-2023. Soldering and Welding Machinery Tenders in aligarh Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37011888
Tender For Various Electric Works On Turn-Key Basis For Electrification And Strengthening Of Infrastructure Due To Extension Of Nagar Nigam Area Eudd-1 Aligarh
Open Tender
Indian
Uttar Pradesh
aligarh
31-03-2023

Tender Details

Tender For Various Electric Works On Turn-Key Basis For Electrification And Strengthening Of Infrastructure Due To Extension Of Nagar Nigam Area Eudd-1 Aligarh-2 Supply Of 11 Mtrs. Long St Pole Is 410 Sp-55 3 Supply Of 09 Mtrs. Long St Pole 4 Supply Of 8.5 Mtrs. Long Pcc Pole 5 Supply Of Stone Pad 6 Supply Of Abc Connector 7 Supply Of Suspension Clamp With Eye Hook 8 Supply Of Dead End Clamp With Eye 9 Supply Of Distritbution Box 10 Supply Of Earthing Complete For St Pole 11 Supply Of Stay Complete ( Gi Stay Rod 16X1800mm, 5 Kgs. Stay Wire 7 / 8, Stay Clamps, Bolts, Nuts & Washers ) 12 Supply Of 11 Kv Xlpe Cable Size 3*185 Sq.Mm. 13 Supply Of Acsr Dog Conductor 14 Supply Of Heat Shrinkable Jointing Kit For 11 Kv Xlpe 3X185 Sq.Mm. Cable Outdoor Type 15 Supply Of L.T. Aeirel Bunch Cable Size 3X120+1X95+1X16 Sq.Mm. 16 Supply Of 100 Kva Distribuition Transoformer 17 Supply Of 250 Kva Distribuition Transoformer 18 Supply Of 11 Kv D.O. Fuse Set 19 Supply Of 11 Kv Tpmo 20 Supply Of Al. Lugs 240Sq.Mm. 21 Supply Of 11 Kv Pin Insulator With Pin 22 Supply Of 11 Kv Disc Insulator With Fitting 23 Supply Of M.S. Top Channel Size 125X65x6 Mm, 2240 Mm. Long With Clamp 24 Supply Of M.S. Dropper Channel Size 100X50x2028 Mm. 25 Supply Of M.S. Base Angle Size 75X75x6mm., 2028 Mm. Long With Clamp For T / F Base 26 Supply Of M.S. T-Off Channel Size 125X65x6 Mm, 2240 Mm. Long With Clamp 27 Supply Of F-Braket With Clamp 28 Supply Of Clamps For Pole 29 Supply Danger Board With Clamp 30 Supply Of Nut, Bolts & Washer 31 Supply Of Barbed Wire 32 Supply Of L.T. Pvc Cable 3.5X240 Sq.Mm. 33 Supply Of L.T. Incoming Panel With Metering Equipment 34 Erection 35 Erection Of Single Support By 11 Mtrs. St Pole Including The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. The Support Shall Be Grouted With Cement, Sand & Brick Ballast In Ratio 1:4:8 Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast Etc. As Per Resspo Manual 36 Erection Of Single Support By 09 Mtrs. St Pole Including The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. The Support Shall Be Grouted With Cement, Sand & Brick Ballast In Ratio 1:4:8 Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast Etc. As Per Resspo Manual 37 Erection Of Single Support By 8.5 Mtrs. Pcc Pole Including The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. The Support Shall Be Grouted With Cement, Sand & Brick Ballast In Ratio 1:4:8 Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast Etc. As Per Resspo Manual 38 Erection Of Double Pole Structure By 11 Mtrs. St Pole Including The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. The Support Shall Be Grouted With Cement, Sand & Brick Ballast In Ratio 1:4:8 Including The Cost Of Arrangement Of Cement, Sand, Brick Ballast Etc. As Per Resspo Manual 39 Laying Of 11 Kv Xlpe Cable 3X185 Sq.Mm. Including Making Proper Connections At Both Ends. The Work Includes The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. 40 Laying Spreading, Lifting And Final Sagging Of Aerial Bunched Cable Size 3X120+1X95+1X16 Sq.Mm. Including Fixing Of All Accessories As Per Resspo Manual And As Per Direction Of Supervising Engineer, Including The Cost Of Arrangement Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work. : 41 Laying Of Lt Pvc Cable 3.5X240 Sq.Mm. Including Making Proper Connections At Both Ends. The Work Includes The Cost Of Labour, T&P And Carrier Etc. Required For Proper Completion Of Work. 42 Laying Sagging Stringing And Jumpering Of Acsr Dog Conductor On The Newly Erected Pole As Per Respo Manual And As Per Direction Of Supervising Engineer, Including The Cost Of Arrangement Of Labour, T&P Carrier Etc. Required For Proper Completion Of Work. 43 Fixing & Connecting Of Earthing Rods As Per Resspo Manual Including The Cost Of Labour, T&P Etc. Required For Proper Completion Of Work. 44 Erection And Grouting Of Stay Set Including The Work Of Nozzling Etc. As Per Respo Manual And Also Including The Cost Of Arrangement Of All Grouting Material, Labour, T&P Etc. Required For Proper Completion Of Work As Per Resspo Manual. 45 Filling Of Heat Shrinkable Jointing Kit For 11 Kv Xlpe 3X185 Sq.Mm. Cable Indoor / Outdoor Type As Per Resspo Norms. 46 Painting Of Double Pole Structure Of St Pole In Two Coats Of Red Oxide And Two Coats Of Silver Paint With Bottom 6 Feet By Fluorescent Paint In Strips. 47 Painting Of Single Pole Structure Of St Pole In Two Coats Of Red Oxide And Two Coats Of Silver Paint With Bottom 6 Feet By Fluorescent Paint In Strips. 48 Erection Of Pin Insulator With Pin & Nuts, 11 Kv 49 Erection Of Disc Insulator With Fittings, 11 Kv 50 Erection Of Danger Board With Nuts & Bolts And Clamps 51 Erection Of M.S. Top Channel Size 125X65x6 Mm, 2240 Mm. Long With Clamp 52 Erection Of M.S. Dropper Channel Size 100X50x2028 Mm. 53 Erection Of M.S. Base Angle Size 75X75x6mm., 2028 Mm. Long With Clamp For T / F Base 54 Erection Of M.S. T-Off Channel Size 125X65x6 Mm, 2240 Mm. Long With Clamp 55 Erection Of F-Braket With Clamp 56 Neutral & Body Earthing Of 11 / 0.4 Kv Sub-Stations Installed By Digging Of Pit Upto Water Level Depth ( Approx. 125 Feet ) And Then Inserting 1-¼” Dia Gi Pipe Of ‘A’ Grade, Conforming To The Requirement Of Is Specification And Then Connecting The Top Of The Inserted Pipe And Transformer Body Through Gi Strip Of Size 40X6 Mm With The Help Of Nut And Bolt Or Through Gas Welding, As Per Direction Of Supervising Engineer. It Includes The Cost Of All Material Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. The Aforesaid Work Shall Be Carried Out As Per Resspo Norms. 57 Plinth With Fencing Of 11 / .04 Kv Sub-Stations Ass Per Resspo Norms. 58 Erection Of Stone Pad 59 Erection Of Peircing Connector 60 Erection Of H.T. / L.T. Clamps With Nuts & Bolts 61 Erection Of Eye-Hook With Suspension Clamps 62 Erection Of 11 Kv Tpmo 63 Erection Of 11 Kv Do Fuse Set 64 Laying Of Barbed Wire 65 Installation Of L.T. Incoming Panel With Metering Equipment 66 Fixing Of Lt Distribution Box Including Making Connections Of Distribution Box With Lt Mains By Piercing Clamps For Aerial Bunched Cable.The Work Will Also Include The Opening Of The Service Connection Of The Consumer And Its Connecting In Distribution Box. 67 Mounting Of 100 Kva Distribution Transformer On Double Pole / Placement On Plinth Including Proper Jumpering From 11 Kv Line To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 68 Mounting Of 250 Kva Distribution Transformer On Double Pole / Placement On Plinth Including Proper Jumpering From 11 Kv Line To The Transformer And Also Connecting The Lt Site Cables As Per Resspo Manual. 69 After Opening Of Ht & Lt Connections, Dismantalling Of25 Kva Distribution Transformer From Double Pole And Its Safe Carriage From Respective Site To Store Including Loading & Unloading At Both Ends. 70 After Opening Of Ht & Lt Connections, Dismantalling Of63 Kva Distribution Transformer From Double Pole And Its Safe Carriage From Respective Site To Store Including Loading & Unloading At Both Ends. 71 After Opening Of Ht & Lt Connections, Dismantalling Of100 Kva Distribution Transformer From Double Pole And Its Safe Carriage From Respective Site To Store Including Loading & Unloading At Both Ends. 72 Removing Of 05 Mva Power Transformer From Plinth To Switchyard As Per Resspo Manual 73 Dismantling Ofold & Used Ms Scrap Form Existing Line And Its Safe Carriage From Site To Store As Per Resspo Norms. 74 Dismantling Ofold & Used Abc Scrap Form Existing Line And Its Safe Carriage From Site To Store As Per Resspo Norms. 75 Dismantling Ofold & Used Conductor Scrap Form Existing Line And Its Safe Carriage From Site To Store As Per Resspo Norms.

Key Value

Document Fees
INR 5900 /-
EMD
INR 1100000.0 /-
Tender Value
INR 11 Crore /-

BOQ Items

Name of Work:
Sl. No. Item Description
1SUPPLY
2Supply of 11 Mtrs. Long ST Pole IS 410 SP-55
3Supply of 09 Mtrs. Long ST Pole
4Supply of 8.5 Mtrs. Long PCC Pole
5Supply of Stone Pad
6Supply of ABC connector
7Supply of suspension clamp with eye hook
8Supply of Dead End Clamp with eye
9Supply of Distritbution Box
10Supply of Earthing Complete for ST Pole
11Supply of Stay complete (GI Stay Rod 16x1800mm, 5 Kgs. Stay wire 7/8, Stay clamps, Bolts, Nuts & Washers)
12Supply of 11 KV XLPE Cable size 3*185 Sq.mm.
13Supply of ACSR Dog Conductor
14Supply of Heat Shrinkable Jointing Kit for 11 KV XLPE 3x185 Sq.mm. Cable Outdoor Type
15Supply of L.T. Aeirel Bunch Cable size 3x120+1x95+1x16 sq.mm.
16Supply of 100 KVA Distribuition Transoformer
17Supply of 250 KVA Distribuition Transoformer
18Supply of 11 KV D.O. Fuse Set
19Supply of 11 KV TPMO
20Supply of Al. Lugs 240Sq.mm.
21Supply of 11 KV Pin Insulator with pin
22Supply of 11 KV Disc Insulator with fitting
23Supply of M.S. Top Channel size 125x65x6 mm, 2240 mm. long with clamp
24Supply of M.S. Dropper Channel size 100x50x2028 mm.
25Supply of M.S. Base Angle size 75x75x6mm., 2028 mm. long with clamp for T/F Base
26Supply of M.S. T-off Channel size 125x65x6 mm, 2240 mm. long with clamp
27Supply of F-Braket with clamp
28Supply of Clamps for Pole
29Supply Danger Board with clamp
30Supply of Nut, Bolts & washer
31Supply of Barbed Wire
32Supply of L.T. PVC cable 3.5x240 Sq.mm.
33Supply of L.T. Incoming Panel with metering equipment
34ERECTION
35Erection of Single Support by 11 Mtrs. ST pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual
36Erection of Single Support by 09 Mtrs. ST pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual
37Erection of Single Support by 8.5 Mtrs. PCC pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual
38Erection of Double Pole Structure by 11 Mtrs. ST pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual
39Laying of 11 KV XLPE Cable 3x185 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work.
40Laying spreading, lifting and final sagging of Aerial Bunched Cable size 3x120+1x95+1x16 sq.mm. including fixing of all accessories as per RESSPO Manual and as per direction of supervising engineer, including the cost of arrangement of labour, T&P carrier etc. required for proper completion of work. :
41Laying of LT PVC Cable 3.5x240 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work.
42Laying sagging stringing and jumpering of ACSR Dog Conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer, including the cost of arrangement of labour, T&P carrier etc. required for proper completion of work.
43Fixing & connecting of earthing rods as per RESSPO Manual including the cost of labour, T&P etc. required for proper completion of work.
44Erection and grouting of stay set including the work of nozzling etc. as per RESPO manual and also including the cost of arrangement of all grouting material, labour, T&P etc. required for proper completion of work as per RESSPO Manual.
45Filling of Heat Shrinkable Jointing Kit for 11 KV XLPE 3x185 Sq.mm. Cable Indoor / Outdoor Type as per RESSPO Norms.
46Painting of Double Pole Structure of ST Pole in two coats of red oxide and two coats of silver paint with bottom 6 feet by fluorescent paint in strips.
47Painting of Single Pole Structure of ST Pole in two coats of red oxide and two coats of silver paint with bottom 6 feet by fluorescent paint in strips.
48Erection of Pin Insulator with Pin & Nuts, 11 KV
49Erection of Disc Insulator with fittings, 11 KV
50Erection of Danger board with Nuts & bolts and clamps
51Erection of M.S. Top Channel size 125x65x6 mm, 2240 mm. long with clamp
52Erection of M.S. Dropper Channel size 100x50x2028 mm.
53Erection of M.S. Base Angle size 75x75x6mm., 2028 mm. long with clamp for T/F Base
54Erection of M.S. T-off Channel size 125x65x6 mm, 2240 mm. long with clamp
55Erection of F-Braket with clamp
56Neutral & body earthing of 11/0.4 KV Sub-stations installed by digging of pit upto water level depth (approx. 125 feet) and then inserting 1-¼” dia GI pipe of ‘A’ grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 40x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer. It includes the cost of all material labour, T&P, carrier etc. required for proper completion of work. The aforesaid work shall be carried out as per RESSPO norms.
57Plinth with fencing of 11/.04 Kv Sub-stations ass per RESSPO Norms.
58Erection of Stone Pad
59Erection of Peircing Connector
60Erection of H.T./L.T. Clamps with Nuts & Bolts
61Erection of Eye-hook with suspension clamps
62Erection of 11 KV TPMO
63Erection of 11 KV DO Fuse Set
64Laying of Barbed wire
65Installation of L.T. Incoming Panel with metering equipment
66Fixing of LT Distribution box including making connections of distribution box with LT mains by piercing clamps for Aerial Bunched Cable.The work will also include the opening of the service connection of the consumer and its connecting in distribution box.
67Mounting of 100 KVA Distribution Transformer on Double pole/ placement on plinth including proper jumpering from 11 KV line to the transformer and also connecting the LT site cables as per RESSPO Manual.
68Mounting of 250 KVA Distribution Transformer on Double pole/ placement on plinth including proper jumpering from 11 KV line to the transformer and also connecting the LT site cables as per RESSPO Manual.
69After opening of HT & LT Connections, dismantalling of25 KVA Distribution Transformer from double pole and its safe carriage from respective site to store including loading & unloading at both ends.
70After opening of HT & LT Connections, dismantalling of63 KVA Distribution Transformer from double pole and its safe carriage from respective site to store including loading & unloading at both ends.
71After opening of HT & LT Connections, dismantalling of100 KVA Distribution Transformer from double pole and its safe carriage from respective site to store including loading & unloading at both ends.
72Removing of 05 MVA Power Transformer from plinth to switchyard as per RESSPO Manual
73Dismantling ofold & used MS Scrap form existing line and its safe carriage from site to store as per RESSPO Norms.
74Dismantling ofold & used ABC Scrap form existing line and its safe carriage from site to store as per RESSPO Norms.
75Dismantling ofold & used Conductor Scrap form existing line and its safe carriage from site to store as per RESSPO Norms.
Disclaimer :