Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Various Electric Works On Turn-Key Basis For Electrification And Strengthening Of Infrastructure Due To Extension Of Nagar Nigam Area Eudd-3 Aligarh. Submission Date for this Tender is 31-03-2023. Soldering and Welding Machinery Tenders in aligarh Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SUPPLY |
2 | Supply of 33 KV control penal |
3 | Supply of 11 kv VCB outgoing (400/200/5A.) |
4 | Supply of Battery Charger 24volt |
5 | Supply of Battery set |
6 | Supply of 11 kv ct for vcb 600/300/5A set |
7 | Supply of 11 kv ct for vcb 400/200/5A set |
8 | Supply of 33 kv Post insulator set |
9 | Supply of Control cable 4x2.5 sqmm. |
10 | Supply of Control cable 2x2.5 sqmm. |
11 | Supply of 11 Mtrs. Long ST Pole IS 410 SP-55 |
12 | Supply of 09 Mtrs. Long ST Pole |
13 | Supply of 8.5 Mtrs. Long PCC Pole |
14 | Supply of Stone Pad |
15 | Supply of ABC connector |
16 | Supply of suspension clamp with eye hook |
17 | Supply of Dead End Clamp with eye |
18 | Supply of Distritbution Box |
19 | Supply of Earthing Complete for ST Pole |
20 | Supply of Stay complete (GI Stay Rod 16x1800mm, 5 Kgs. Stay wire 7/8, Stay clamps, Bolts, Nuts & Washers) |
21 | Supply of 11 KV XLPE Cable size 3*70 Sq.mm. |
22 | Supply of 11 KV XLPE Cable size 3*185 Sq.mm. |
23 | Supply of 33 KV XLPE Cable size 3*300 Sq.mm. |
24 | Supply of ACSR Dog Conductor |
25 | Supply of Heat Shrinkable Jointing Kit for 11 KV XLPE 3x70 Sq.mm. Cable Outdoor Type |
26 | Supply of Heat Shrinkable Jointing Kit for 11 KV XLPE 3x185 Sq.mm. Cable Outdoor Type |
27 | Supply of Heat Shrinkable Jointing Kit for 33 KV XLPE 3x300 Sq.mm. Cable Outdoor Type |
28 | Supply of L.T. Aeirel Bunch Cable size 3x95+1x35+1x16 sq.mm. |
29 | Supply of L.T. Aeirel Bunch Cable size 3x120+1x95+1x16 sq.mm. |
30 | Supply of 100 KVA Distribuition Transoformer |
31 | Supply of 250 KVA Distribuition Transoformer |
32 | Supply of 11 KV D.O. Fuse Set |
33 | Supply of 11 KV TPMO |
34 | Supply of Al. Lugs 400Sq.mm. |
35 | Supply of 11 KV Pin Insulator with pin |
36 | Supply of 11 KV Disc Insulator with fitting |
37 | Supply of M.S. Top Channel size 125x65x6 mm, 2240 mm. long with clamp |
38 | Supply of M.S. Dropper Channel size 100x50x2028 mm. |
39 | Supply of M.S. Base Angle size 75x75x6mm., 2028 mm. long with clamp for T/F Base |
40 | Supply of M.S. T-off Channel size 125x65x6 mm, 2240 mm. long with clamp |
41 | Supply of F-Braket with clamp |
42 | Supply of Clamps for Pole |
43 | Supply Danger Board with clamp |
44 | Supply of L.T. PVC cable 3.5x150 Sq.mm. |
45 | Supply of L.T. PVC cable 3.5x400 Sq.mm. |
46 | Supply of L.T. Incoming Panel with metering equipment |
47 | Supply of 33 KV Lightening Arrestor |
48 | ERECTION |
49 | Erection of Single Support by 11 Mtrs. ST pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual |
50 | Erection of Single Support by 09 Mtrs. ST pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual |
51 | Erection of Single Support by 8.5 Mtrs. PCC pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual |
52 | Erection of Double Pole Structure by 11 Mtrs. ST pole including the cost of labour, T&P and carrier etc. required for proper completion of work. The support shall be grouted with cement, sand & brick ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast etc. as per RESSPO Manual |
53 | Laying of 33 KV XLPE Cable 3x300 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work. |
54 | Laying of 11 KV XLPE Cable 3x185 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work. |
55 | Laying of 11 KV XLPE Cable 3x70 Sq.mm. including making proper connectionst both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work. |
56 | Laying spreading, lifting and final sagging of Aerial Bunched Cable size 3x120+1x95+1x16 sq.mm. including fixing of all accessories as per RESSPO Manual and as per direction of supervising engineer, including the cost of arrangement of labour, T&P carrier etc. required for proper completion of work. : |
57 | Laying of LT PVC Cable 3.5x150 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work. |
58 | Laying of LT PVC Cable 3.5x400 Sq.mm. including making proper connections at both ends. The work includes the cost of labour, T&P and carrier etc. required for proper completion of work. |
59 | Laying sagging stringing and jumpering of ACSR Dog Conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer, including the cost of arrangement of labour, T&P carrier etc. required for proper completion of work. |
60 | Fixing & connecting of earthing rods as per RESSPO Manual including the cost of labour, T&P etc. required for proper completion of work. |
61 | Erection and grouting of stay set including the work of nozzling etc. as per RESPO manual and also including the cost of arrangement of all grouting material, labour, T&P etc. required for proper completion of work as per RESSPO Manual. |
62 | Filling of Heat Shrinkable Jointing Kit for 33 KV XLPE 3x300 Sq.mm. Cable Indoor / Outdoor Type as per RESSPO Norms. |
63 | Filling of Heat Shrinkable Jointing Kit for 11 KV XLPE 3x185 Sq.mm. Cable Indoor / Outdoor Type as per RESSPO Norms. |
64 | Filling of Heat Shrinkable Jointing Kit for 11 KV XLPE 3x70 Sq.mm. Cable Indoor / Outdoor Type as per RESSPO Norms. |
65 | Installation of 33 KV control penal |
66 | Installation of 11 kv VCB outgoing (400/200/5A.) |
67 | Installation of Battery Charger 24volt |
68 | Installation of Battery set |
69 | Fixing of 11 kv ct for vcb 600/300/5A set |
70 | Fixing of 11 kv ct for vcb 400/200/5A set |
71 | Fixing of 33 kv Post insulator set |
72 | Laying of Control cable 4x2.5 sqmm. |
73 | Laying of Control cable 2x2.5 sqmm. |
74 | Painting of Double Pole Structure of ST Pole in two coats of red oxide and two coats of silver paint with bottom 6 feet by fluorescent paint in strips. |
75 | Painting of Single Pole Structure of ST Pole in two coats of red oxide and two coats of silver paint with bottom 6 feet by fluorescent paint in strips. |
76 | Erection of Pin Insulator with Pin & Nuts, 11 KV |
77 | Erection of Disc Insulator with fittings, 11 KV |
78 | Erection of Danger board with Nuts & bolts and clamps |
79 | Erection of M.S. Top Channel size 125x65x6 mm, 2240 mm. long with clamp |
80 | Erection of M.S. Dropper Channel size 100x50x2028 mm. |
81 | Erection of M.S. Base Angle size 75x75x6mm., 2028 mm. long with clamp for T/F Base |
82 | Erection of M.S. T-off Channel size 125x65x6 mm, 2240 mm. long with clamp |
83 | Erection of F-Braket with clamp |
84 | Neutral & body earthing of 11/0.4 KV Sub-stations installed by digging of pit upto water level depth (approx. 125 feet) and then inserting 1-¼” dia GI pipe of ‘A’ grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 40x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer. It includes the cost of all material labour, T&P, carrier etc. required for proper completion of work. The aforesaid work shall be carried out as per RESSPO norms. |
85 | Erection of Stone Pad |
86 | Erection of Peircing Connector |
87 | Erection of H.T./L.T. Clamps with Nuts & Bolts |
88 | Erection of Eye-hook with suspension clamps |
89 | Erection of 11 KV TPMO |
90 | Erection of 11 KV DO Fuse Set |
91 | Installation of L.T. Incoming Panel with metering equipment |
92 | Installation of 33 KV Lightening Arrestor |
93 | Fixing of LT Distribution box including making connections of distribution box with LT mains by piercing clamps for Aerial Bunched Cable.The work will also include the opening of the service connection of the consumer and its connecting in distribution box. |
94 | Installation of 100 KVA Distribution Transformer on Double pole/plinth including proper jumpering from 11 KV line to the transformer and also connecting the LT site cables as per RESSPO Manual. |
95 | Installation of 250 KVA Distribution Transformer on Double pole/ plinth including proper jumpering from 11 KV line to the transformer and also connecting the LT site cables as per RESSPO Manual. |
96 | After opening of HT & LT Connections, dismantalling of10 KVA Distribution Transformer from double pole and its safe carriage from respective site to store including loading & unloading at both ends. |
97 | After opening of HT & LT Connections, dismantalling of25 KVA Distribution Transformer from double pole and its safe carriage from respective site to store including loading & unloading at both ends. |
98 | After opening of HT & LT Connections, dismantalling of63 KVA Distribution Transformer from double pole and its safe carriage from respective site to store including loading & unloading at both ends. |
99 | After opening of HT & LT Connections, dismantalling of100 KVA Distribution Transformer from double pole and its safe carriage from respective site to store including loading & unloading at both ends. |
100 | Removing of 05 MVA Power Transformer from plinth to switchyard as per RESSPO Manual |
101 | Dismantling ofold & used ST Poles 09 Mts. and its safe carriage from site to store as per RESSPO Norms. |
102 | Dismantling ofold & used Conductor Scrap form existing line and its safe carriage from site to store as per RESSPO Norms. |
Copyright © 2023 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail