Rate Contract For Repair And Maintenance Of Electrical Accessories And Wiring In Nagar Nigam Buildings., bikaner-Rajasthan

Department Of Local Bodies has published Rate Contract For Repair And Maintenance Of Electrical Accessories And Wiring In Nagar Nigam Buildings.. Submission Date for this Tender is 06-04-2023. Electrification Work Tenders in bikaner Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

36994828
Rate Contract For Repair And Maintenance Of Electrical Accessories And Wiring In Nagar Nigam Buildings.
Open Tender
Indian
Rajasthan
bikaner
06-04-2023

Tender Details

Rate Contract For Repair And Maintenance Of Electrical Accessories And Wiring In Nagar Nigam Buildings.- 1 Wiring Of Light Point / Fan Point / Exhaust Fan Point / Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade ( Is:694 ) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & ItS All Accessories ( J.B. , Bends Etc. ) , Round Tiles, 18 Swg G.I. Box With Earth Terminal, 6 A Switch , 3 Pin Ceiling Rose / Lamp Holder / 3 Point Connector, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet ( Is : 2036 - 1995 ) , Al. Alloy / Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Short Point ( Up To 3 Mtr. ) 2 Medium Point ( Up To 6 Mtr. ) 3 Long Point ( Up To 10 Mtr. ) 4 Wiring Of 3 / 5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade ( Is:694 ) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & ItS All Accessories ( J.B. , Bends Etc. ) , Round Tiles, 18 Swg G.I. Box With Earth Terminal Of Required Size, 6 A Switch, 3 / 5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet ( Is : 2036 - 1995 ) , Al. Alloy / Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . On Board 5 Short Point ( Up To 3 Mtr. ) 6 Medium Point ( Up To 6 Mtr. ) 7 Long Point ( Up To 10 Mtr. ) 8 S&F Following Sizes ( Dia. ) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories ( Is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr .Mms ( Is:9537 P - Iii ) Pvc Conduit 25Mm 9 Mms ( Is:9537 P - Iii ) Pvc Conduit 32Mm 10 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc / Ms Conduit / Casing Capping Including All As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nablab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr .1 X 1.5 Sq.Mm 11 2 X 1.5 Sq.Mm 12 1 X 2.5 Sq.Mm 13 2 X 2.5 Sq.Mm 14 2 X 4.0 Sq.Mm 15 Supply & Drawing Wiring For Sub Mains As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) , 1100 Volts Grade Pvc Insulated Flat Twin Core Sheathed Solid Aluminium Conductor With 10 Swg G.I. Support Wire Duly Clipped Including All As Per Pre Approved By Engineer In Charge, Making Connections, As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 4.0 Sq.Mm 16 6.0 Sq.Mm 17 10.0 Sq.Mm 18 Supplying And Laying Isi Marked P.V.C. Insulated Submersible Cable As Per Pwd Specification For Electrical Works Confirming To Is:694 And As Per Is 8130 : 2013 Of 1.1 Kv Grade .Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4 Including Making Connection Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. All As Per Pre Approved By Engineer In Charge, Making Connections. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 2.5 Sq.Mm 3 Core Flat / Round. 19 Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load And Site Requirement ) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Single Pole Mcb 6 A To 32 A Rating 20 Double Pole Mcb6 A To 32 A Rating 21 Four Pole Mcb40 A Rating 22 Four Pole Mcb50-63 A Rating 23 Providing & Fixing Of Ik09 Recessed / Surface Mounting Heavy Duty Horizontal Type Sheet Steel Not Less Then 1.2 Mm Thick Distribution Board As Per Pwd Specification For Electrical Works Isi Marked Conforming To Is-13032 & Is-8623 / Conforming To Iec 61439-3. Phosphatised / Powder Painted Complete With Suitable Rating Insulated Copper Bus Bar, Shorting Link , Neutral Link, Earth Link , Connecting Wire Of Suitable Rating And Din Bar, Masking Sheet, Including Making Internal Db Terminations With Copper Lugs And With Detachable Gland Plate, Including Making Connections, Testing Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Ip-43 Double Door ( Single Phase ) . 8 Way ( 8 O / G +2 I / C ) 24 Ip-43 Double Door ( Three Phase ) 8 Way ( 24 O / G + 8 I / C ) 25 Providing & Fixing Of Isi Marked ( Is :3854 ) 6 Amp. Flush Type Non Modular Switch As Per Pwd Specification For Electrical Works, Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Minimum Width Of Switch Toggle ( Push Part ) Should Not Less Then 16 Mm, Brass Terminal & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 26 Providing & Fixing Of Isi Marked ( Is :3854 ) 16 Amp. Flush Type Non Modular Switch As Per Pwd Specification For Electrical Works, Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material , Minimum Width Of Switch Toggle ( Push Part ) Should Not Less Then 16 Mm, Brass Terminal & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 27 Providing & Fixing Of Of 3 Pin 6 Amp. Flush Type Non Modular Socket As Per Pwd Specification For Electrical Works, Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 28 Providing & Fixing Of 3 / 6 Pin 16 Amp Flush Type Non Modular Socket As Per Pwd Specification For Electrical Works, Made Out Fromindustrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 29 Providing & Fixing Of Isi Marked ( Is :3854 ) 6 Amp. Combined Flush Type Non Modular Socket And Switch Set As Per Pwd Specification For Electrical Works, Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Minimum Width Of Switch Toggle ( Push Part ) Should Not Less Then 18 Mm, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 30 Providing & Fixing Of Isi Marked ( Is :3854 ) 16 Amp. Combined Flush Type Non Modular Socket And Switch Set With Indicator And Fuse Set As Per Pwd Specification For Electrical Works, Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 31 Providing And Fixing Of Non Modular Power Plug Point Accessories As Per Pwd Specification For Electrical Works With 18 Swg G I Box Of Size 175 X 100 X 60 Mm With Earthing Terminal / Connector On Recessed / Surface With Suitable Size Phenolic Laminated Sheet ( Is : 2036 - 1995 ) Cover Including Cost Of 16 Amp. Switch ( Is :3854 ) And 3 / 6 Pin 16 Amp. Socket Outlet [ As Per Detailed In Respective Item In Bsr ] , Making Connection , Testing , Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 32 Providing & Fixing Of Isi Marked ( Is:1293 ) 6 Amp Unbreakable 3 Pin Plug Top With Lamp Indicator As Per Pwd Specification For Electrical Works, Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal Including Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 33 Providing & Fixing Of Isi Marked ( Is:1293 ) 16 Amp Unbreakable 3 Pin Plug Top With Lamp Indicator As Per Pwd Specification For Electrical Works, Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal Including Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 34 Providing & Fixing Of Non Modular Socket Size Flush Type 120 Watt Rotary Minimum 5 Step Fan Regulator As Per Pwd Specification For Electrical Works, Isi Marked ( Is:11037 ) Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 35 Providing & Fixing Of Isi Marked ( Is:2268-1994 ) Single / Multi Tone Electronic Call Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 36 Supply, Fixing And Testing Of Following Capacity Wall Mounted Stablisers Having Output Voltage Variation From 200V To 250V ( + / -5% ) With Input Voltage Variation From 170V To 260V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270V Complete In All Respect E074601 3 Kva 37 Providing & Fixing Of Ip51 Direct Or Ct Operated, 1X240 / 3X240 Volts, 50 Hz Static Watt-Hour Meter ( Kwh ) As Per Pwd Specification For Electrical Works, Isi Marked ( Is :13010-2002 ) Having Resolution 0.1 / 0.01 Kwh , Accuracy Class 1 As Per Is:13779, Led Indicators For Tamper Operation ( Reverse & / Or Earth Connection ) , Pulsating Led Indicator For Meterology , Lcd Display, Cover Plate For Body And Terminal Sealing , Push Button For All Standard Parameters, Including Making Connection , Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 10 A To 60 Ampere Single Phase Meter. 38 Providing & Fixing Of Iso Certified Company Made Tp&N 415 V Side Handle Operated Double Break Fuse Switch Unit In Sheet Steel Enclosure As Per Pwd Specification For Electrical Works Conforming To Is / Lec 60947-3 : 1999 ( W / O Hbc Fuses ) Including Making Connections With Suitable Lugs, Testing Etc. As Required. Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 100 A Rating 39 Providing & Fixing Of Iso Certified Company Made 240 / 415 V Porcelain Kitkat Fuse ( / Hbc Type ) As Per Pwd Specification For Electrical Works Conforming To Is:2086, 1983 On Existing Board / Sheet Including Making Connections With Lugs, Testing Etc. As Required . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 63 A , 415 V. 40 100 A , 415 V 41 Providing & Fixing Of Iso Certified Company Made Bus Bar Chamber Housed In Sheet Metal Box As Per Pwd Specification For Electrical Works Confirming To Iec-60439 / Is-8623 & Iec-60529 / Is-2147 Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Degree Of Protection Ip-31 Front Openable Bus Bar Made Out Of Aluminium Or Wrought Aluminium Alloy Suitable For 200 Amp. Capacity , Bus Bar Fixed On Porcelain / Dmc Insulators At Approved Spacing Including Making Connections Etc. As Required. Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 300 Mm Long , 4 Strip. 42 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured / Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points ( A ) , ( B ) , ( C ) , Mentioned Below:- ( A ) Material :- H4- Grade Aluminium Conductor Of Purity >99.6 % & As Per Is:1554 P-I / Is :7098 P – I ( B ) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testing Procedures. ( C ) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities For Cables . Appropriate Type Testcertificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr. E110110 Un-Armoured 16.0 Sq. Mm 4 Core. 43 Un-Armoured25.0 Sq. Mm 4 Core 44 Providing & Laying Of Double Wall Corrugated Pipe Confirming To Is : 14930 P - 1 & 2 With Hdpe Coupler At 1 Mtr. Depth Below The Ground For Laying Cable Including Making The Trench And Back Filling , Compaction Of Earth As Required ( Excavation Of Earth To Be Paid Extra As Required. ) Of Following Outer Dia. / Inner Dia As Per Is:4984:1995. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr .55 / 50 Mm. 45 Sitc Of Chemical Gel Earthing System Of Dual Pipe Technology Made Of With B Class G I Pipe As Per Is 1239 ( Part-1 ) :2004 Of Medium Duty Of Following Sizes As Per Points Mentioned ( A ) , ( B ) , [ C ) , ( D ) , ( E ) Below :- ( A ) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri / Erda Tested With Rms Capacity Of Minimum 35- 40 Ka For Withstanding 1 Second . ( B ) To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043-1987, Ieee 80-2013 ( Clause 14.5D ) , Ieee 837 & Ier 1956 With Latest Amendemnts ( C ) Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. ( D ) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. ( E ) Self Certificate For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . E140510 With Pipe In Pipe Technology ( Outer Pipe Dia. / Inner Pipe Dia. ) Minimum 100 Mm Dia Borewell Gi Pipe 2000 Mm Long, 50 / 25Mm, Terminal 40Mm X 6 Mm Gi Strip. 46 Supply & Laying Following Size Earth Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Jointing Shall Be Done By Overlapping And With 2 Set Of Brass ( For Custrip ) / Gi ( For Gi Strip ) Nut Bolt & Spring Washer Spaced At 50Cm Making Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 25Mm X 3Mm G.I. ( Hot Dipped ) Strip 47 Supply & Laying Following Size Earth Wire In Horizontal Or Verticalrun In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection With Gi / Cu Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 8 Swg Copper Wire. 48 Providing & Fixing Of Iso Certified Company Made Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan As Per Pwd Specification For Electrical Works, Conform To All The Performance Requirements Laid Down In Is:374-2019 Including All Amendments, As Applicable ; & Carry Bis Licensing ( I.E. Isi Marking ) Or Quality Certification Such As Iso - 9001 Or Above. With Down Rod Up To 30 Cm With Secondary Support. 1200 Mm Sweep Bee 2 Star Rated ( Service Value >=4.5 To < 5 ) . 49 Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor , Making Connections, Testing Etc. As Required. Oem Shall Be An Iso Certified Company. Appropriate Oem Test Certificate Shall Be Submitted By Contractor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 225 Mm Sweep 50 Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wound Double Ball Bearing 900 / 1400 Rpm Single Phase Exhaust Fan As Per Pwd Specification For Electrical Works, Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. Oem Shall Be An Iso Certified Company. Appropriate Oem Test Certificate Shall Be Submitted By Contractor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 300 Mm Sweep ( 900 / 1400 Rpm ) . 51 Providing & Fixing Of Capacitor Start, Copper Wound, Metal Body, Metal Blade Three Speed Wall Mounting Fan Of Following Sweep With The Help Of Anchor Bolts Including Making Connection Testing Etc. As Required. Oem Shall Be An Iso Certified Company. Appropriate Oem Test Certificate Shall Be Submitted By Contractor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 400 Mm Sweep ( Oscillating Type ) . 52 Providing & Fixing Of Fluorscent Tube Rod In Existing Fixtures As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Flourscent Powder Coated. 36 / 40 Watts. 53 Providing & Fixing Of Energy Efficient / Energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm / Watt Output , Pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 / Lm80 ) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . Foe Additional Technical Parameters Of Product / Work, Refer Annexure A Attacheded With This Bsr. 9 Watt 54 15 Watt 55 Rewinding Of Ceiling Fan Motor ( Starting And Running Winding ) Including All Necessary Material. The Motor Is To Be Wound Taking No. Of Coils, Turns And Pitch As It Was Originally Wound With Required Size Super Enamelled Wire With E Class Insulation Material And Making Connections Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. ( New Model Ceiling Fan ) . 900 / 1200 Mm Sweep ( New Model Ceiling Fan ) 56 Labour Charges For Removing And Refixing Of Ceiling Fan / Exaust Fan From Site 57 Charges For Oiling, Overhauling Of Ceiling Fan, Table Fan, Pedestal Fan Irrespect To The Size Of Fan Including Removing, Refixing Of Fan From Site And Testing Etc. As Required. Fans With Removing & Refixing At Suitable Location. 58 Providing And Replacement Of Ball Bearing Of Ceiling / Exhaust Fan And Refixing The Same At Suitable Location As Requiredand As Per Oem Recommendations. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 59 P & Replacement Of Cover / Bearing Seat Of Ceiling / Exhaust Fan. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 60 P & F Aluminium Blades ( A Set Of 3 Blades ) Duly Painted And Well Finished 900 / 1200 Mm. The Material Of The Fan Blade Shall Be Of Designation 31500B With Condition Hx6 Aluminium Alloy Sheet Confirming To Is 737 / 2008. 61 Servicing And Overhauling Of 20 Sweep Desert Cooler Including Oiling, Greasing, Painting Of Tank From Inside With Rubber Paint After Properly Desmantling Each Assembly And Refixing The Same As Required. 62 Painting Of Desert Cooler With Two Coats Of Rubber Paint Inside Of Water Tank And Two Coat Of Synthetic Enamelled Paint On Both Side Of Cooler Body, Fan Body, Grills Etc.After Cleaning With Sand Paper, Complete In All Respect As Required. 63 Replacement Of Cooler Pads ( Heavy ) Set Of 3 No. Of Size 25 X 27 64 P & F Aluminiun Blade For 20 Desert Cooler Fan As Required. 65 P & F Of Isi Marked Vertical Pump Suitable For 20 Desert Cooler Including Making Connection Testing Etc. As Required. Isi Marked Vertical Pump. 66 P & F Fan Motor Suitable For 20 Desert Cooler Including Making Connection Testing Etc. As Required. With Copper Winding Motor Isi Marked. 67 Rewinding Of Heavy Duty Exhaust Fan Motor Including All Necessary Material, The Motor Is To Be Wound Taking No. Of Coils, Turns And Pitch As It Was Originally Wound With Required Size Supernamelled Wire With E Class Insulation Material And Making Connections Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 300 / 380 Mm Sweep. 68 Rewinding Of Motor Of Desert Cooler Pump With Super Enamelled Copper Wire, E Class Insulation Material Including Removing, Refixing, Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 69 Rewinding Of Motor Of Desert Cooler Fan With Super Enamelled Copper Wire, E Class Insulation Material Including Removing, Refixing, Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By Thecontractor. 70 Supplying And Charging Of Fresh Refrigerant And Testing Of Performance Of Air Conditioner / Fridge / Water Cooler Of Following Capacity Including Capillary And Strainer / Filter. 1.5 Tr Window / Split A.C. 71 2.0 Tr Window / Split A.C. 72 25 / 50 / 40 / 80 Ltr. Water Cooler 73 Replacement Of Defective Compressor By Company Repaired Compressor As Per Oem Recommendations Of Following Gadgets Including Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 1.5 Tr A.C. 74 2.0 Tr A.C. 75 25 / 50 / 40 / 80 Ltr. Water Cooler 76 P & Replacement Of Condensing / Cooling Coil Of Copper Fins For Following Capacity A.C. / Water Cooler / Fridge As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 1.5 Tr A.C. 77 2.0 Tr A.C. 78 25 / 50 / 40 / 80 Ltr. Water Cooler 79 Servicing Of 1.0 / 1.5 / 2.0 Tr Capacity Split / Window Type Air Conditioner. 80 P & Replacement Of Overload Protection Of A.C. / Water Cooler As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 81 P & Replacement Of Thermostat Of A.C. / Water Cooler / Fridge As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 82 P & Replacement Of Selector Switch Of 1.0 / 1.5 / 2.0 Tr A.C Fan As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 83 P & Replacement Of Starting Relay Of A.C / Water Cooler / Fridge Compressor As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 84 S & F Of Capacitor Of 230V / 275V, 50Hz Rating Of Plastic Casing And Terminals -Lugs Or Copper Wire. Starting Capacitor.40-60 Micro Farad. 85 60-80 Micro Farad. 86 Running Capacitor 2.5 / 3.15 Micro Farad. 87 4.0 Micro Farad 88 6.0 Micro Farad 89 8.0 Micro Farad 90 10.0 Micro Farad 91 Providing & Fixing Of Ip20 Led Surface / Recessed / Suspended Mounting Mid Power Smd Type Led Light Fixture Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non - Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 2.5 Kv Internal / External Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection And In Compliance To Iec Standards ( Integral With Light Fixture ) . System Lumen Efficacy Min. 100 Lm / Watt , Thd < 10 % , P.F.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing On Housing. Oem Must Have Its Own In House Nabl Acredeated Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 / Lm80 ) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product / Work, Refer Annexure A Attacheded With This Bsr. Recessed Mounting 48W Led Light Fixture 2X2 With Acrylic / Prismatic Front Cover. 92 Gas Charging Of Vrf / Vrv System With R410a Refrigerant Gas. Before Gas Charging System Shall Be Flushed With High Purity Nitrogen Gas To Remove Carbon Content, Dirt Particles To Make Sure That There Is No Chance Of Mixing Any Impurity With Refrigerant Gas. Thereafter System Shall Be Tested With Nitrogen Gas At 1.5 Times Of Working Pressure Of R410 Refrigerant Gas To Ensure Leakproof System. Whole System Shall Be Vacuumed Up To 500-Micron Level Which Ensures The Zero-Moisture Content Level In Piping To Ensure Better Cooling Efficiency And Long Life Of The System. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr .

Key Value

Document Fees
INR 1000 /-
EMD
INR 27120.0 /-
Tender Value
INR 13.56 Lakhs /-

BOQ Items

Name of Work: Rate Contractfor repair and maintenance of Electrical accessories and wiring in Nagar Nigam buildings.
Sl. No. Item Description
1Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Short point (up to 3 mtr.)
2Medium point (up to 6 mtr.)
3Long point (up to 10 mtr.)
4Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . On board
5Short point (up to 3 mtr.)
6Medium point (up to 6 mtr.)
7Long point (up to 10 mtr.)
8S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .MMS ( IS:9537 P - III ) PVC conduit 25mm
9MMS ( IS:9537 P - III ) PVC conduit 32mm
10Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABLab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1 x 1.5 sq.mm
112 x 1.5 sq.mm
121 x 2.5 sq.mm
132 x 2.5 sq.mm
142 x 4.0 sq.mm
15Supply & drawing Wiring for sub mains as per PWD specification for electrical Works with ISI marked (IS:694) , 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped including all as per pre approved by Engineer in charge, making connections, as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 4.0 sq.mm
166.0 sq.mm
1710.0 sq.mm
18Supplying and Laying ISI marked P.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 2.5 Sq.mm 3 core flat / Round.
19Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Single pole MCB 6 A to 32 A rating
20Double pole MCB6 A to 32 A rating
21Four pole MCB40 A rating
22Four pole MCB50-63 A rating
23Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . IP-43 Double door (single phase). 8 Way (8 O/G +2 I/C )
24IP-43 Double door (Three phase) 8 Way ( 24 O/G + 8 I/C )
25Providing & Fixing of ISI marked (IS :3854) 6 amp. flush type non modular switch as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, minimum width of switch toggle ( PUSH PART ) should not less then 16 mm, brass terminal & captive screws including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
26Providing & Fixing of ISI marked (IS :3854) 16 amp. flush type non modular switch as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material , minimum width of switch toggle ( PUSH PART ) should not less then 16 mm, brass terminal & captive screws including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
27Providing & Fixing of of 3 pin 6 amp. flush type non modular socket as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
28Providing & Fixing of 3/6 pin 16 amp flush type non modular socket as per PWD specification for electrical Works, made out fromindustrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
29Providing & Fixing of ISI marked (IS :3854) 6 amp. Combined flush type non modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fire resistant ABS material, minimum width of switch toggle( PUSH PART ) should not less then 18 mm, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
30Providing & Fixing of ISI marked (IS :3854) 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
31Providing and fixing of non modular power plug point accessories as per PWD specification for electrical Works with 18 SWG G I box of size 175 x 100 x 60 mm with earthing terminal/connector on recessed/surface with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet [ as per detailed in respective item in BSR], making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
32Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top with lamp indicator as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
33Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top with lamp indicator as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
34Providing & Fixing of non modular socket size flush type 120 watt rotary minimum 5 step fan regulator as per PWD specification for electrical Works, ISI marked (IS:11037) made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
35Providing & Fixing of ISI marked (IS:2268-1994) single / multi tone electronic call bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
36Supply, Fixing and testing of following capacity wall mounted stablisers having output voltage variation from 200V to 250V(+/-5%) with input voltage variation from 170V to 260V, time delay facility from 2 to 4 minute and high cutoff at 270V complete in all respect E074601 3 kVA
37Providing & Fixing of IP51 direct or CT operated, 1x240 / 3x240 volts,50 Hz static watt-hour meter (kwh) as per PWD specification for electrical Works, ISI marked (IS :13010-2002 ) having resolution 0.1 / 0.01 kwh , accuracy class 1 as per IS:13779, LED indicators for tamper operation ( Reverse &/or earth connection) , pulsating LED indicator for meterology , LCD Display, cover plate for body and terminal sealing , push button for all standard parameters, including making connection ,testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 10 A to 60 ampere Single phase meter.
38Providing & Fixing of ISO certified company made TP&N 415 V side handle operated double break fuse switch unit in sheet steel enclosure as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 (W/O HBC fuses) including making connections with suitable lugs, testing etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 100 A rating
39Providing & Fixing of ISO certified company made 240/415 V porcelain kitkat fuse (/HBC type) as per PWD specification for electrical Works conforming to IS:2086,1983 on existing board/ sheet including making connections with lugs, testing etc. as required . Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 63 A , 415 V.
40100 A ,415 V
41Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/ IS-8623 & IEC-60529/ IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 300 mm long , 4 strip.
42Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type testcertificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. E110110 Un-armoured 16.0 Sq. mm 4 core.
43Un-armoured25.0 Sq. mm 4 core
44Providing & laying of Double wall corrugated pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required( Excavation of Earth to be paid Extra as required. ) of following Outer Dia. / Inner dia as per IS:4984:1995. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .55/50 mm.
45SITC of chemical Gel earthing system of Dual Pipe Technology made of with "B" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c),(d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second . (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . E140510 With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell GI pipe 2000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip.
46Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Custrip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 25mm x 3mm G.I. ( Hot Dipped ) Strip
47Supply & Laying following size earth wire in horizontal or verticalrun in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 8 SWG copper Wire.
48Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support. 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5).
49Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 225 mm sweep
50Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 300 mm sweep(900/1400 RPM).
51Providing & Fixing of capacitor start, copper wound, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 400 mm sweep(Oscillating type).
52Providing & Fixing of Fluorscent tube rod in existing fixtures as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Flourscent powder coated. 36/40 Watts.
53Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy =100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR. 9 Watt
5415 Watt
55Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with "E" class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. (New model ceiling fan) . 900/1200 mm sweep (New model ceiling fan)
56Labour charges for removing and refixing of Ceiling fan/ Exaust fan from site
57Charges for oiling, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required. Fans with Removing & Refixing at Suitable Location.
58Providing and Replacement of ball bearing of ceiling/ exhaust fan and refixing the same at suitable location as requiredand as per OEM recommendations. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
59P & Replacement of cover/ bearing seat of ceiling/ exhaust fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
60P & F Aluminium Blades (a set of 3 blades) duly painted and well finished 900/ 1200 mm. The material of the fan blade shall be of designation 31500B with condition HX6 aluminium alloy sheet confirming to IS 737/2008.
61Servicing and overhauling of 20" sweep desert cooler including oiling, greasing, painting of tank from inside with rubber paint after properly desmantling each assembly and refixing the same as required.
62Painting of desert cooler with two coats of rubber paint inside of water tank and two coat of synthetic enamelled paint on both side of cooler body, fan body, grills etc.after cleaning with sand paper, complete in all respect as required.
63Replacement of cooler pads (heavy) set of 3 no. of size 25" x 27"
64P & F aluminiun blade for 20"" desert cooler fan as required.
65P & F of ISI marked vertical pump suitable for 20" desert cooler including making connection testing etc. as required. ISI marked vertical pump.
66P & F fan motor suitable for 20" desert cooler including making connection testing etc. as required. with copper winding Motor ISI Marked.
67Rewinding of Heavy duty Exhaust fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size supernamelled wire with "E" class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. 300/ 380 mm sweep.
68Rewinding of motor of desert cooler pump with super enamelled copper wire, "E " class insulation material including removing,refixing,testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
69Rewinding of motor of desert cooler fan with super enamelled copper wire, "E " class insulation material including removing,refixing,testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by thecontractor.
70Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capillary and strainer/ filter. 1.5 TR Window/ Split A.C.
712.0 TR Window/ Split A.C.
7225/50 / 40/80 Ltr. Water cooler
73Replacement of defective compressor by company repaired compressor as per OEM recommendations of following gadgets including testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. 1.5 TR A.C.
742.0 TR A.C.
7525/50 / 40/80 Ltr. Water cooler
76P & Replacement of condensing/ cooling coil of copper fins for following capacity A.C./ Water cooler/ Fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. 1.5 TR A.C.
772.0 TR A.C.
7825/50 / 40/80 Ltr. Water cooler
79Servicing of 1.0/1.5/2.0 TR capacity Split/ Window type air conditioner.
80P & Replacement of overload protection of A.C./ Water cooler as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
81P & Replacement of thermostat of A.C./ Water cooler/fridge as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
82P & Replacement of selector switch of 1.0/1.5/2.0 TR A.C Fan as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
83P & Replacement of starting relay of A.C/water cooler/fridge compressor as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
84S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire. Starting capacitor.40-60 micro farad.
8560-80 micro farad.
86Running capacitor 2.5/3.15 micro farad.
874.0 micro farad
886.0 micro farad
898.0 micro farad
9010.0 micro farad
91Providing & Fixing of IP20 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System Lumen efficacy min. 100 lm/watt ,THD < 10 % , p.f.=0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR. Recessed Mounting 48W LED light fixture 2"x2" with acrylic / prismatic front cover.
92Gas charging of VRF/VRV system with R410A refrigerant gas. Before gas charging system shall be flushed with high purity Nitrogen Gas to remove carbon content, dirt particles to make sure that there is no chance of mixing any impurity with Refrigerant Gas. Thereafter System shall be tested with Nitrogen Gas at 1.5 Times of working pressure of R410 Refrigerant Gas to ensure leakproof system. Whole system shall be Vacuumed up to 500-micron level which ensures the zero-moisture content level in piping to ensure better cooling efficiency and long life of the system. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .