Tender For Repair Maintenance Operation Electrical Installation And Fans Pump Sets Street Light Fire Fighting Dg Set Sub Station Pa System Lifts In Pwd Colony Sector Iii Dwarka New Delhi Sh Routine Operation And Maintenance Of E And M Services Including O, Delhi-Delhi

Public Works Department-PWD has published Tender For Repair Maintenance Operation Electrical Installation And Fans Pump Sets Street Light Fire Fighting Dg Set Sub Station Pa System Lifts In Pwd Colony Sector Iii Dwarka New Delhi Sh Routine Operation And Maintenance Of E And M Services Including O. Submission Date for this Tender is 01-04-2023. Passenger Lift Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

36989124
Tender For Repair Maintenance Operation Electrical Installation And Fans Pump Sets Street Light Fire Fighting Dg Set Sub Station Pa System Lifts In Pwd Colony Sector Iii Dwarka New Delhi Sh Routine Operation And Maintenance Of E And M Services Including O
Open Tender
Indian
Delhi
Delhi
01-04-2023

Tender Details

Tender For Repair Maintenance Operation Electrical Installation And Fans Pump Sets Street Light Fire Fighting Dg Set Sub Station Pa System Lifts In Pwd Colony Sector Iii Dwarka New Delhi Sh Routine Operation And Maintenance Of E And M Services Including Operation Of Lifts And Misc Electrical Works Routine Operation And Maintenance Of E And M Services Including Operation Of Lifts And Misc Electrical Works

Key Value

Document Fees
Refer document
EMD
INR 167239.0 /-
Tender Value
INR 83.61 Lakhs /-

BOQ Items

Name of Work: RMO EI and fans, pump sets, street light, fire fighting, DG set, Sub-Station, PA system lifts in PWD Colony, Sector-III, Dwarka, New Delhi. (SH : Routine operation & maintenance of E & M services i/c operation of Lifts and misc. electrical work).
Sl. No. Item Description
1SH- I-(A- Maintenance & Operation of EI & Fans)
2Maintenance & operation of various E&M services of GNCTD staff qtrs Dwarka comprising of following services on all days of the month i/c Sunday and Holidays i/c attending day to day complaint, rectification of fault, up-keeping and preventive maintenance of all electricals & mechanical installation complete etc as reqd. as per terms & conditions. The firm shall depute their trained supervisor/Engineer at the site for all the below services and for duty chart of the deployed staff.
3(i) Internal and External electical installations i/c compound lighting i/c DG Set with AMF Panel & L.T. Panel :- (a) Wireman - 3 Nos. (One No. in each shift) (b) Khallasi - 2 Nos. One no. in each shift 6 AM to 2 PM & 2 PM to 10 PM
4B - Misc. Works
5Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
6Group C
7Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling and credit of old material etc completeas required
8Group C
9Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
103 x 1.5 sq. mm
113 x 4 sq. mm
123 x 6 sq. mm
13Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1420 mm
1525 mm
1632 mm
17Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
183 Module (100mm X 75mm)
196 Module (200mm X 75mm)
208 Module (125mm X 125mm)
21Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without CB/RCCB/Isolator)
228 way , Double door
2312 way , Double door
24Supplying and fixing followingrating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25Single pole - 5 to 32 Amp
26Double pole - 63 Amp
27Providing and fixing following rating and breaking capacityand pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections i/c credit of old material i/c retrofittings of MCCB in the existing cubical paneletc. as required.
28100 Amp, 16 KA,TPMCCB
29125 Amp, 16 KA,TPMCCB
30100 Amp, 25 KA, FPMCCB
31125 Amp, 36KA, FPMCCB
32Providing laying, testing & commissioning of "C" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground / RCC including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
33150 mm. Dia
34Supplying installation, testing & commissioning of LED post top fitting of having minimum system lumens 4000 & system efficacy 100 lumens/watt, THD =10%, Power Factor=0.95, CRI=80, IP 66 made out of high pressure die cast aluminium housing with pre-wired gear tray with LEDs and driver, supply directly i/c connections with 1.5 sqmm., PVC insulated, FRLS copper conductor, single core cable on the existing pole complete with making suitable arrangement to fix on the existing pole using reducer/ enlarger if required, testing and commissioning etc. as required.
35Supplying, installation, testing & commissioning of following wattage street light LED fittings having minimum system lumens output should more than8640 & system efficacy =120 lumens/watt, IP66 protected, body made out of pressure die cast aluminium for better thermal management, power factor=0.95, THD=10%, CRI=70% & CCT 4000-6500 °Ki/c fixing on existing pole / bracket making connection etc complete as required.
36Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required
3763 mm dia (OD-63 mm & ID-51 mm nominal)
38Supplying and Laying of one number PVC insulated and PVC sheathed Aluminium conductor XLPE armoured power cable of 1.1 KV grade of following size direct in existing DWC/ Hume Pipe complete etc. as required.
394 x 10 sqmm (In ground)
404 x 25 sqmm (In ground)
41Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.
42Supplying and Laying of following size one number PVC insulated and PVC sheathed / XLPE power aluminium conductor armoured cable of 1.1 KV grade on surface of wall etc. as reqd.
434 x 25 Sq.mm
44Supplying installation, testing & commissioning of LED post top fitting of having minimum system lumens 2500 & system efficacy 100 lumens/watt, THD =10%, Power Factor=0.95, CRI=80, IP 66 made out of high pressure die cast aluminium housing with pre-wired gear tray with LEDs and driver, supply directly i/c connections with 1.5 sqmm., PVC insulated, FRLS copper conductor, single core cable on the existing pole complete with making suitable arrangement to fix on the existing pole using reducer/ enlarger if required, testing and commissioning etc. as required.
45Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/ support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
46(c) 150 mm dia
47Supply and Fixing of Pole Mounted Junction Box made up of SMC material , size 370X270X210 mm mmhaving din bar/rail , connectors, 10A c curve mcb including suitable connection ofcable/wire in boxetc as required.
48Brush/spray Painting of poles (8-10 mtr approx.) with aluminium glossy enamel paint including scrapping old paint, providing two layer of red oxide paint and then coating with two layer of enamel paint complete as required. Hiring of tower wagon numbering of pole and name of department.
49Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20 mm) of specified size and shape including form work, plastering if required, curing etc. as required. (volume of pole/ pipe not to be deducted)
50SITC of electric driven 15 HPmonoblock typepump Set TEFC type suitablefor operation on 415 volts, 3 phase 50 Hz AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class - "F" insulation conforming to IS-325 withcentrifugal pump of cast iron body, bronze impeller with stainless steel shaft, mechanical seal and flow rate 1194 to 732 LPM at 22 to 52 mtr.head suction /deleivery of 85x65 mm confirming to IS 1520, M.S. fabricatedbase plate, foundation bolts with anti vibration pads, etc. as reqd.
51Fabrication, supplying and fixing of indoor cubical type panel board, dust, damp and vermin proof, compartmentalized, free floor standing, made out of 2.0 mm thick CRCA sheet minimum 30 cm deep (NS) duly powder coated & painted (CPRI approved) complete with 4 strips alu. bus bar of 400 amps.capacity complete with solid connection, interconnections, internal wiring with copper conductor cable of suitable sizes, earthing, sellector switch for auto mannual on/off i/c testing & commissioning etc. as reqd.
52Supplying and fixing following accessories in the existing cubical type control panel for pump room etc. as reqd.
53Star delta meter starter for monoblock pump set including OverloadProtection ,Single Phasing Protection ,Phase Reversal Protection , Phase Unbalance Protection , Ruggedcontactor with moulded coil , Auto Restart (with variable 30 Sec – 5 Min ON delay), Power ON & Pump OFF indication, Dual Voltmeter & Ammeter - 5 No.s
54VAF+PF Meter CLASS 1 Accuracy - 01 Nos
55CT 300/5 Amp burden 10 VA Accuracy class 1 - 3 Nos.
56phase indicatin lamp (RYB)-01 No.s
574 pole MCCB, 200A, 36kA - 01 No.s
5832 A ratings, DP MCB, “C” curve, 10 kA breaking capacity - Nos.
59Fabrication, supplying and fixing of indoor cubical type panel board, dust, damp and vermin proof, compartmentalized, free floor standing, made out of 2.0 mm thick CRCA sheet minimum 40 cm deep (NS) duly powder coated & painted (CPRI approved) complete with 4 strips alu. bus bar of 800 amps.capacity complete with solid connection, interconnections, internal wiring with copper conductor cable of suitable sizes, earthing, sellector switch for auto mannual on/off i/c testing & commissioning etc. as reqd.
60Supplying and fixing following accessories in the existing cubical type L.T. Panel in substation etc. as reqd.
614 pole MCCB,630A, 50kA - 02No.s
624 pole MCCB,250A, 36kA-01 Nos
63VAF+PF Meter CLASS 1 Accuracy - 01 No.
64CT 1000/5 Amp burden 15 VA Accuracy class 1 - 3 Nos.
65phase indicatin lamp (RYB) - 01 No.
6632 A ratings, DP MCB, “C” curve, 10 kA breaking capacity - 1 Nos.
67C - Supply of material
68Following material shall be supply by agency and existing man power shall be used for replacement on day to day maitenance works.
69S.P. 5/6 A, one way switch, piano type ISI marked
70S.P. 5/6 A, two way switch, piano type ISI marked
71S.P. 15/16 A, one way switch, piano type ISI marked
723 pin 5/6 A socket outlet, piano type ISI marked
736 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
74Bell push, piano type
75Brass pendant holder
765 AmpModular Switch
775 AmpModular Socket
7815/16 AmpModular Switch
7915/16 AmpModular Socket
806 to 32 Amp SP MCB
8140 Amp DP MCB
8263 Amp DP MCB
8363 amp TPN MCB
841.5 Sq.mm FRLSCuwire
854Sq.mm FRLS Cuwire
866Sq.mm FRLSCu wire
872.50 mF capacitor
881200 mm ceiling fan (White)
89Heavy Duty Exhaust Fan 300 mm Sweep (900 RPM)
90Exhaust fan 380 mm sweep (1400 r.p.m)
91450 mm sweep heavy duty exhaust fans
92250 mm Air freshner /Ventilator fan
9320-22 wattsurface mounted self Ballasted LED Batten with Aluminium body with opaldiffuser having 100 lumens/watt and colour temperture of 5500-6500 kelvin and CRI of >80 andhaving power factor of >0.95, etc. Complete as reqd.
949-12 wattsurface type self Ballasted round LED downlighter with Glare free opaldiffuser having 100 lumens/watt and colour temperture of 5500-6500 kelvin and CRI of >80 andhaving power factor of >0.95, I.P. 20 Protectionetc. complete as reqd.
957-9 watt recess type self Ballasted round LED downlight for lift with Glare free opaldiffuser having 100 lumens/watt and colour temperture of 5500-6500 kelvin and CRI of >80 andhaving power factor of >0.95, I.P. 20 Protectionetc. complete as reqd.
96200 Watt flood light LED fittings on Parapet of building with energy efficient, IP66 protected, body made out of pressure die cast aluminium for better thermal management,power factor>0.95, THD<10%, CRI>70%, system efficacy =120 Lm/W & CCT 5700-6500 °Ki/c makingconnection etc complete as required.
97Call bell/ buzzer, single phase
9816 Amp. Modular Switch socket combined PVC Box
99Ceiling rose, 3 pin, 5 A ISI marked
1003 mm thick phenolic laminated sheet
101D-Credit of old dismanteled material
1021.5 / 4 / 6 Sq.mm FRLSCuwire
1035 / 15 Amp. Switch Sockets & Fan regulator
104SPMCB
105DP MCB
10663 Amp. TPN
107Exhaust fan 380/450
108ventilationfan - 250 mm & 150 mm
10920-22 wattsurface mounted self Ballasted LED Batten
1109-12 wattsurface type self Ballasted round LED downlighter
1117-9 watt recess type self Ballasted round LED downlight
112200 Watt flood light LED fittings
113SH- II-(Maintenance & Operation of FF, FA & PA system)
114Fire Fighting System, Fire Alarm System and PA system- i/c Fire Pumps, Fire Engine etc.(i)Fire fighting system, Fire alarm system and PA system (Round the clock) (a) Fire Operator - 3 Nos. (One No. in each shift) (b) Khallasi - 2 Nos. (One No. in general Shift 9 AM to 5 PM- + 1 No. 10 PM to 6 A
115Sub Head - III (Operation of Lifts)
116Operation of 12 nos. passanger lift (2 nos. in each block) i/c cleaning, sweeping of lift car at PWD colony, Sector-III, Dwarka comprising of following services on all days of the month i/c Sundays and holidays as per terms & conditions enclosed :- (a) Lift Operatpor - 4 Nos. (Two nos. in each shift) (6 AM to 2 PM & 2 PM to 10 PM) (b) Lift Operator - 2 Nos. (Night shift 10 PM to 6 AM)
117Sub Head - IV (Comprehensive maintenance of DG set)
118Comprehensive maintrenance of following silent type DG sets installed at GNCTD Staff Qtrs. at Sector-3, Dwatrka, complete with AMF panel, diesel tank, fuel pump and other associated accessories etc. i/c carrying out preventive / periodic maintenane and servicing (with 2 Nos. B ckeck kit for each DG set i/c Mobile oil, Air, fuel, oil filters, coolant, descalant, gasket, rocker lever cover etc) attending all major / minor faults and / or failure etc. complete as reqd. as per the terms and conditions attached. 320 KVA DG set Cumins :- 1 No. Model No. - NTA-855-G2