Tender For Rate Contact For Fire Safter Works

Issued by Government Departments · ranchi, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Mar 2023
0 days left
EMD
2.50 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Rate Contact For Fire Safter Works Fire Safter Works , Fire Fighting And Hydrant System , Supply, Installation, Testing And Commissioning Of Pressure Switches In Ms Pipe For Hydrant Electric Pump/ Sprinkler Electric Pump/ Diesel Engine Drivenpump/ Jockey Pumps, Diaphragm Type Adjustable Range From 0-10Kg/Sq. Cm And A Regulation Range Of 0.1 -1.5 Kg/Sq.Cm Direct Mounted Snap Acting Type Made From Die Cast Aluminium With Epoxy Powder Coated Finishand Ss316 Diaphragm And Other Materials Parts, Including Necessary Wiring Upto Control Panel & Materials As Required As Per Specifications. Approved Make: Indfoss/Dandfoss , Supplying & Fixing Internal And External Stainless Steel Single Headed Fire Hydrant Landing Valve With Instantaneous Stainless Steel Coupling Of 63Mm Dia With Cast Iron Wheel Isi Marked Conforming To Is:5290 (Type-A) With Blank Pvc Cap And Chain As Required Approved Make: Newage / Safex / Shah Bhogilal / Kartar , Providing & Fixing 63 Mm Dia Stainless Steel Short Branch Pipe With 20Mm With Hose Box Lockable Type Single Door (Nominal Internal Diameter) In Size Stainless Steel Nozzle Conforming To Is:903 Suitable For Instantaneous Connection Complete To Inter-Connect Hose Pipe, Coupling Etc. As Required And As Per Enclosed Specification. Approved Make: Newage /Safex / Shah Bhogilal , Providing & Fixing 63Mm Dia. 15Mtr, Long Rrl Hose Pipe (Isi Marked) With 63Mm Dia. Male And Female Stainless Steel Couplings , Duly Binded With Gi Wire, Rivets Etc. Conforming To Is-636 (Type-A) Complete As Required & As Per Enclosed Specification. Approved Mark : Newage / Crc , Providing And Fixing First-Aid Hose Reel 20Mm Dia. X 30M Long (Minimum Length) (Thermoplastic Type As Per I.S. 12585) Complete With Drum, Bracket, 25Mm Dia. Shut-Off Valve And 5Mm Gun-Metal Nozzle Conforming To Is-:884, Connection With Riser With Ms C- Class Pipe, Painting The Ms Works Complete As Required & As Per Enclosed Specification. Approved Make: Newage / Safex / Shah Bhogilal , Providing And Fixing 4 Way Gun-Metal Fire Brigade Inlet Connection Comprising Of 4 Nos. 63Mm Dia. Male Instantaneous Inlet Couplings With Cap And Chain As Required For 150Mm Dia. Flanged Conforming To Is- 904 Complete (To Be Connected To Static Tank) As Required And As Per Enclosed Specification. Approved Make : Newage / Safex / Shah Bhogilal/Kartar , Providing And Fixing Fire Brigade Suction Hose Coupling (Draw Out Connection) With Nut For Female Coupling As Per Is-902 Complete With 150Mm Dia. Suction Pipe And Foot Valve (To Be Connected To Static Tank) Complete As Required And As Per Enclosed Specification . Approved Make: Newage / Safex / Shah Bhogilal/ Kartar , Supply, Installation Testing & Commissioning Of Two-Way Gun Metal Fire Brigade Inlet Connection Consisting Of 63Mm Size Instantaneously Male Coupling And Shall Be Protected By Cap Scored With A Chain Glass Bore Etc. Complete With One Butter Fly Valve And 1 Nos Non- Return Valve.( For External Ring Main, Tower Hydrant)Approved Make: Newage/ Safex/ Shah Bhogilal , Pipes & Valves , Providing, Fixing, Jointing And Commissioning Of Following Sizes Of C- Class Heavy Duty Mild Steel Pipes Conforming To Is-1239/Is-3589, Including Cutting Welding, Threading, Hut Bolts Gasket, Fitting, Viz Bends, Ceiling/ Beam/Floor With Suitable Ms Clamps / Structural Supports/ Pcc Block And Painting Complete As Required And As Per Enclosed Specification . Approved Make: Tata/ Jindal/Apollo Note:- The Pies Size 150Mm & Below Shall Be M.S.C Class As Per Is : 1239 And Pipes Size Above 150Mm Shall Be Welded Black Steel Pipe Heavy Class As Per Is:3589, From Minimum 6.35Mm Thick M.S. Sheet For Pipes Upto 350Mm Dia. And From Minimum 7Mm Thick Ms Sheet For Pipes Of 400Mm Dia And Above. , 150 Mm Dia. , 100 Mm Dia. , 80 Mm Dia. , 50 Mm Dia. , 25 Mm Dia. , Providing Fixing Testing And Commissioning Of Following Sizes Of Gate Valve Of Rating Pn 16, Wafer Type In Cast Iron Body With Ductile Lron Disc, Epdm Seal, Ss Single Piece Shaft Conforming To Is-13095 Of The Following Sizes Complete With Cast Iron Hand Lever Companion Flanges, Bolts Nuts Washers & Inserted Rubber Gaskets, As Required And As Per Enclosed Specification. Approved Make: Leasderloto.Oto/Sant , 150 Mm Dia. , 100 Mm Dia. , Providing, Fixing, Testing And Commissioning Of Following Size Of Ci Non Return Valve Conforming To Api-594 With C.I. Body, Ss Disc, Ss Stem, Epdm Seal, Completewith Companionflanges, Bolts, Nuts, Washers & Inserted Rubber Gasket Complete As Required And As Per Enclosed Specification. (Pn-16) Approved Make: Leader/Zoloto / Sant 100 Mm Dia. , Providing & Fixing Of 25Mm Dia. Gunmetal , Air Release Valve With All Fitting And Forged Ball Valve On Header Complete As Required And As Per Enclosed Specification. Approved Make: Leader/Zoloto / Sant , Providing And Fixing Following Size Pressure Gauge (0-15 Kg/Cm2) Complete With Shut Off Valve Duly Calibrated Before Installation Complete As Required & As Per Enclosed Specification. 150Mm Dia. Approved Make: H.Guru / Feibig , Providing, Fixing & Installation Of Control Valve (Sprinkler Alarm Valve) Of Cast Iron Body And Bronze Working Parts Comprising Of Water Motor Alarm, Bronze Seat Clapper And Clapper Arm, Hydraulically Driven Mechanical Gong Bell To Sound Continuous Alarm When The Wet Riser/Sprinkler System Activates, Pressure Gauges, Emergency Releases, Strainer, Pressure Switch, Cock Valve Complete With Drain Valve And Bypass, Test Control Box, Ball Valves, Flanges, Orifice Plate, Fittings, Gasket Etc. Suitable For 150 Mm Diameter Pipe Size Complete As Required As Per Enclosed Specification. Approved Make: Hd / Newage , Automatic Sprinkler System , Providing & Fixing Of 15 Mm Dia. Sprinkler Head With Standard Response Quartzite Bulb Operate At 68 Degree C Complete With All Accessories As Required And As Per Enclosed Specification (Ul Listed) Pendent Type In Chrome Finish (Standard Coverage) Approved Make: Hd / Tyco/Vking/Newage , Providing And Fixing Electrically Operated Flow Indicating Switches Vane Type With Threaded Connection For Indicating Water Flow In Sprinkler Branch Line With Necessary Junction Box In Stalled In Accessible Place. Including Cost Of Cable Etc. Complete. (Wiring From Switches To Panel And Stair-Case Pressurisation Not Included). , Approved Make: Honeywell/ Sensotronic System/ Switzer , Providing And Fixing 25Mm Dia Inspecting & Testing Assembly With S.S. Isolation Valve S.S. Sight Glass Byepass Valve & Connected To Line Drain Complete In All Respect As Per Standard Practice Of Code Including Pressure Gauges Of Approved Make. Approved Make: Reliable /Hd/Ul/Listed , Fire Extinguisher , Supply, Installation, Testing And Commissioning Isi Marked (Is:15683) Fire Extinguisher, Carbon-Di-Oxide Type Capacity 4.5 Kg. Flat Base Including Valve, Discharge Hose Of Not Less Than 10Mm Dia, 1M Long And Complete In All Respects Including Initial Fill With Co2 Gas Conforming To Is: 307-1966 And Wall Suspensionbraket As Required As Per Specifications. Approved Make: Minimax/ Safex/ Cease Fire/ Safeguard , Blood Bank (Co2 Trolly 9 Kg) , New Building (Co2 4.5 Kg) , Red Building (Co2 Trolly 9 Kg) , C.S Office (Co2 Trolly 9 Kg) , Other Urban Health Institution Of Ranchi , Supply, Installation, Testing And Commissioning Of 6Kg Abc (Powder/Dcp Type) Fire Extinguisher , Mid Steel Cylinders Isi Marked Fitted With Pressure Indicating Gauge, Internal Tube, Squeeze Lever Type Valve Fully Charged With Abc 90 Powder (Mono Ammonium Phosphate) Pressured By Nitrogen Complete In All Respects Including Wall Suspension Bracket And Conforming To Is : 15683 As Required As Per Specifications . Approved Make: Minimax/ Safex/ Cease Fire/ Safeguard/Safepro/ Kanex , Mechanical Foam Type Fire Extinguisher In Hp Mild Steel Cylinders Isi Marked / Approved Fitted With Pressure Indicating Gauge, Internal Tube, Squeeze Lever Type Valve Fully Charged Complete In All Respects Including Wall Suspension Bracket / Trolley , Mounted And Conforming To Is:910 50 Litres (Trolley Mounted) Approved Make: Minimax / Safex / Cease Fire / Safeguard , Fireterrace Pump Type:End Suction Speed (Rpm): 2900 Capacity: 900 Ipm Head : 35Mtr. , Providing Fixing, Testing And Commissioning Of Control Panel For Terrace Booster Pumps. Incoming: Mccb 35A 1 Set Of Phase Indicating Lamps, 1 Set Of 35Al Bus Bars, 1 No Ammeter, 1 No Voltmeter Withphase Selector Switch Feeder For Booster Pumps-1No. 1 No. 32A Tp Mccb Without Releases, Dol Starter With Over Load Relay , Single Phase Preventer And Indicating Lamps With On/Off Push Buttons. 1 No . Automanual Selector Switch ,Suitable For Booster Pumps Water Reservoir 1.00L , Fire Alarm And Detection Works , Conventional Type / Addressable Type Manual Alarm System , Supply Installation Testing And Commissioning Of 24V Manual Call Point Mcp Agni/Morley/Siemens , Supply Installation , Testing & Commissioning Of 24 V Hooter Agni/Morley/Siemens , Supply Installation , Testing & Commissioning Of 6/8 Zone Control Panel Agni/Morley/Siemens , Wire 2X1.5Mm Armoud Cable Fire Proof (Anchor/Poly Cap / Havlles) , Supply Installation , Testing & Commissioning Of Smoke + Heat Detector Ionised Type With Base Agni/Morley/Siemens , Supply Installation , Testing & Commissioning Of Response Indicator 24V Agni/Morley/Siemens , Civil Work , Supply Installation& Commissioning Of 5000 Letters Of Sintex Water Container (Four Layer) For Over Head Water Storage For Fire Hydrant& Fire Sprinkler System , Construction Of Rcc Over Head Water Tank With 20,000 L Water Capacity With Superior Quality Concrete, Steel & Materials , Fire Suppression System , Supply Installation& Commissioning Of Fire Suppression System Fk5112 Specially For Fire Panal Automatic Type Life Guard / Spectra/ Novac , Supply Refilling And Maintenance Of Fire Extinguisher Cylinder Of All Building Of Sadar Hospital Ranchi , Fire Safety Mock Drill Of 100 People Of Sadar Hospital Ranchi Given Quarterly , Maintenance Of Water Reservoirof 200000 L & Repairing If Needed , General Maintenance Of Fire Fighting Amc Including, Testing , Repairing & Refilling Of Cylinder Only

BOQ

Name of Work: Rate Contract for Machine Upkaran andOthers
Sl. No. Item Description
1FIRE FIGHTING AND HYDRANT SYSTEM
2Supply, Installation, testing and commissioning of pressure switches in MS pipe for Hydrant Electric pump/ Sprinkler Electric pump/ Diesel Engine DrivenPump/ Jockey Pumps, diaphragm type adjustable range from 0-10kg/sq. cm and a regulation range of 0.1 -1.5 kg/sq.cm direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finishand SS316 diaphragm and other materials parts, including necessary wiring upto control panel &materials as required as per specifications. Approved make: INDFOSS/DANDFOSS
3Supplying & fixing Internal and External Stainless steel single headed fire hydrant landing valve with instantaneous stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS:5290 (Type-A) with blank PVC cap and chain as requiredApproved Make: NEWAGE / SAFEX / SHAH BHOGILAL / KARTAR
4Providing & fixing 63 mm dia stainless steel short Branch pipe with 20mm WITH Hose BOX Lockable type single Door (nominal internal diameter) in size stainless steel nozzle conforming to IS:903 suitable for instantaneous connection complete to inter-connect hose pipe, coupling etc. as required and as per enclosed specification.Approved Make: NEWAGE /SAFEX / SHAHBHOGILAL
5Providing & fixing 63mm dia. 15mtr, longRRL hose pipe (ISI Marked) with 63mm dia. Male and female stainless steel couplings
6duly binded with GI wire, rivets etc. conforming to IS-636 (Type-A) complete as required & as per enclosed specification.Approved Mark : NEWAGE / CRC
7Providing and fixing First-Aid Hose Reel 20mm dia. x 30m long (minimum length) (Thermoplastic Type as per I.S. 12585) complete with drum, bracket, 25mm dia. Shut-off valve and 5mm Gun-Metal nozzle conforming to IS-:884, Connection with riser with MS C- class pipe, painting the MS works complete as required & as per enclosed specification.Approved Make: NEWAGE / SAFEX / SHAHBHOGILAL
8Providing and fixing 4 way Gun-metal Fire Brigade inlet connection comprising of 4 nos. 63mm dia. Male instantaneous inlet couplings with cap and chain as required for 150mm dia. Flanged conforming to IS- 904 complete (to be connected to static tank) as required and as per enclosed specification.Approved Make : NEWAGE / SAFEX / SHAHBHOGILAL/KARTAR
9Providing and fixing fire brigade suction hose coupling (draw out connection) with nut for female coupling as per IS-902 complete with 150mm dia. Suction pipe and foot valve (to be connected to static tank) complete as required and as per enclosed specification .Approved Make: NEWAGE / SAFEX / SHAHBHOGILAL/ KARTAR
10Supply, installation testing & commissioning of two-way gun metal fire brigade inlet connection consisting of 63mm size instantaneously male coupling and shall be protected by cap scored with a chain glass bore etc. complete with one butter fly valve and 1 Nos non- return valve.( For external ring main, tower hydrant)Approved Make: NEWAGE/SAFEX/ SHAH BHOGILAL
11PIPES & VALVES
12Providing, fixing, jointing and commissioning of following sizes of C- class heavy duty Mild Steel pipes conforming to IS-1239/IS-3589, including cutting welding, threading, hut bolts gasket, fitting, viz bends, ceiling/ beam/floor with suitable MS clamps / structural supports/ PCC block and painting complete as required and as per enclosed specification .Approved Make: TATA/ JINDAL/APOLLO Note:- The Pies size 150mm & below shall be M.S.\"C\" class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS:3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350mm dia. and fromminimum 7mm thick MS Sheet for pipes of 400mm dia and above.
13150 mm dia.
14100 mm dia.
1580 mm dia.
1650 mm dia.
1725 mm dia.
18Providing fixing testing and commissioning of following sizes of Gate Valve of rating PN 16, wafer type in cast iron body with Ductile Lron disc, EPDM seal, SS single piece shaft conforming to IS-13095 of the following sizes complete with cast iron hand lever companion flanges, bolts nuts washers & inserted rubber gaskets, as required and as per enclosed specification. Approved Make: LEASDERLOTO.OTO/SANT
19150 mm dia.
20100 mm dia.
21Providing, fixing, testing and commissioning of following size of CI non return valve conforming to API-594 withC.I. body, SS Disc, SS stem, EPDM seal, completewith companionflanges, bolts, nuts, washers & inserted rubber gasket complete as required and as per enclosed specification. (PN-16)Approved Make: LEADER/ZOLOTO / SANT100 MM DIA.
22Providing & fixing of 25mm dia. Gunmetal
23air release valve with all fitting and forged ball valve on header complete as required and as per enclosed specification.Approved Make: LEADER/ZOLOTO / SANT
24Providing and fixing following size Pressure gauge (0-15 Kg/Cm2) complete with shut off valve duly calibrated before installation complete as required & as per enclosed specification.150mm dia. ApprovedMake: H.GURU / FEIBIG
25Providing, fixing & installation of control valve (Sprinkler Alarm Valve) of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, orifice plate, fittings, gasket etc. suitable for 150 mm diameter pipe size complete as required as per enclosed specification.Approved Make: HD / NEWAGE
26AUTOMATIC SPRINKLER SYSTEM
27Providing & fixing of 15 mm dia. Sprinkler head with standard response Quartzite Bulb operate at 68 degree C complete with all accessories as required and as per enclosed specification (UL Listed) Pendent type in chrome finish (Standard Coverage) Approved Make: HD /TYCO/VKING/NEWAGE
28Providing and fixing electrically operated flow indicating switches Vane type with threaded connection for indicating water flow in sprinkler branch line with necessary junction box in stalled in accessible place. including cost of Cable Etc. Complete. (Wiring from switches to panel and stair-case pressurisation notincluded).
29Approved Make: HONEYWELL/ SENSOTRONIC SYSTEM/ SWITZER
30Providing and fixing 25mm dia inspecting & testing assembly with S.S. isolation valveS.S. sight glass byepass valve & connected to line drain complete in all respect as per standard practice of code including pressure gauges of approved make.Approved Make: RELIABLE /HD/UL/LISTED
31FIRE EXTINGUISHER
32Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS: 307-1966 and wall suspensionbraket as required as per specifications.Approved Make: MINIMAX/ SAFEX/ CEASE FIRE/ SAFEGUARD
33BLOOD BANK (Co2 Trolly 9 KG)
34NEW BUILDING (Co2 4.5 KG)
35RED BUILDING (Co2 Trolly 9 KG)
36C.S OFFICE (Co2 Trolly 9 KG)
37Other urban Health institution of Ranchi
38Supply, installation, testing and commissioning of 6kg ABC (Powder/DCP Type) Fire Extinguisher , Mid Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by nitrogen complete in all respects including wall suspension bracket and conforming to IS : 15683 as required as per specifications .Approved Make: MINIMAX/ SAFEX/ CEASEFIRE/ SAFEGUARD/SAFEPRO/ KANEX
39Mechanical Foam type Fire Extinguisher in HP Mild Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respectsincluding wall suspension bracket / trolley
40mounted and conforming to IS:910 50 Litres (trolley mounted) Approved Make:MINIMAX / SAFEX / CEASE FIRE / SAFEGUARD
41FireTerrace PumpType:End suction Speed (rpm): 2900 capacity: 900 IpmHead : 35Mtr.
42Providing fixing, testing and commissioning of control panel for Terrace Booster pumps. Incoming: MCCB 35A 1 set of Phase indicating lamps, 1 set of 35Al bus bars, 1 No Ammeter, 1 No Voltmeter withphase selector switch Feeder for Booster Pumps-1No. 1 No. 32A TP MCCB without releases, DOL starter with over load relay , single phase preventer and indicating lamps with ON/OFF push buttons. 1 No . Automanual selector switch ,Suitable for boosterpumps Water Reservoir 1.00L
43FIRE ALARM AND DETECTION WORKS
44CONVENTIONAL TYPE / ADDRESSABLETYPE MANUAL ALARM SYSTEM
45Supply Installation testing and commissioning of 24V Manual call point MCPAGNI/MORLEY/SIEMENS
46Supply installation , testing & commissioning of 24 V HOOTERAGNI/MORLEY/SIEMENS
47Supply installation , testing &commissioning of 6/8 Zone control panel AGNI/MORLEY/SIEMENS
48Wire 2x1.5mm armoud cable fire proof(Anchor/Poly cap / Havlles)
49Supply installation , testing & commissioning of Smoke + Heat Detector Ionised type with BaseAGNI/MORLEY/SIEMENS
50Supply installation , testing &commissioning of response indicator 24V AGNI/MORLEY/SIEMENS
51Civil Work
52Supply installation& commissioning of 5000 letters of SINTEX water container (four Layer) for over head water storagefor fire hydrant& fire sprinkler system
53Construction of RCC over head water tank with 20,000 l water capacity with superiorquality concrete, steel & materials
54FIRE SUPPRESSION SYSTEM
55Supply installation& commissioning of Fire Suppression system FK5112 Specially for Fire Panal Automatic typeLIFE GUARD / SPECTRA/ NOVAC
56Supply refilling and Maintenance of Fire extinguisher cylinder of all building ofsadar hospital Ranchi
57Fire safety Mock Drill of 100 people of Sadar hospital Ranchi given quarterly
58Maintenance of water reservoirof200000 L & repairing if needed
59General maintenance of Fire Fighting AMCincluding, testing , repairing & refilling of cylinder only

AI Tender Summary

OUR REF NO 36976606
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 30-03-2023
Authority
Authority Name Health Department
Work Description Rate Contact For Fire Safter Works Fire Safter Works , Fire Fighting And Hydrant System , Supply, Installation, Testing And Commissioning Of Pressure Switches In Ms Pipe For Hydrant Electric Pump/ Sprinkler Electric Pump/ Diesel Engine Drivenpump/ Jockey Pumps, Diaphragm Type Adjustable Range From 0-10Kg/Sq. Cm And A Regulation Range Of 0.1 -1.5 Kg/Sq.Cm Direct Mounted Snap Acting Type Made From Die Cast Aluminium With Epoxy Powder Coated Finishand Ss316 Diaphragm And Other Materials Parts, Including Necessary Wiring Upto Control Panel & Materials As Required As Per Specifications. Approved Make: Indfoss/Dandfoss , Supplying & Fixing Internal And External Stainless Steel Single Headed Fire Hydrant Landing Valve With Instantaneous Stainless Steel Coupling Of 63Mm Dia With Cast Iron Wheel Isi Marked Conforming To Is:5290 (Type-A) With Blank Pvc Cap And Chain As Required Approved Make: Newage / Safex / Shah Bhogilal / Kartar , Providing & Fixing 63 Mm Dia Stainless Steel Short Branch Pipe With 20Mm With Hose Box Lockable Type Single Door (Nominal Internal Diameter) In Size Stainless Steel Nozzle Conforming To Is:903 Suitable For Instantaneous Connection Complete To Inter-Connect Hose Pipe, Coupling Etc. As Required And As Per Enclosed Specification. Approved Make: Newage /Safex / Shah Bhogilal , Providing & Fixing 63Mm Dia. 15Mtr, Long Rrl Hose Pipe (Isi Marked) With 63Mm Dia. Male And Female Stainless Steel Couplings , Duly Binded With Gi Wire, Rivets Etc. Conforming To Is-636 (Type-A) Complete As Required & As Per Enclosed Specification. Approved Mark : Newage / Crc , Providing And Fixing First-Aid Hose Reel 20Mm Dia. X 30M Long (Minimum Length) (Thermoplastic Type As Per I.S. 12585) Complete With Drum, Bracket, 25Mm Dia. Shut-Off Valve And 5Mm Gun-Metal Nozzle Conforming To Is-:884, Connection With Riser With Ms C- Class Pipe, Painting The Ms Works Complete As Required & As Per Enclosed Specification. Approved Make: Newage / Safex / Shah Bhogilal , Providing And Fixing 4 Way Gun-Metal Fire Brigade Inlet Connection Comprising Of 4 Nos. 63Mm Dia. Male Instantaneous Inlet Couplings With Cap And Chain As Required For 150Mm Dia. Flanged Conforming To Is- 904 Complete (To Be Connected To Static Tank) As Required And As Per Enclosed Specification. Approved Make : Newage / Safex / Shah Bhogilal/Kartar , Providing And Fixing Fire Brigade Suction Hose Coupling (Draw Out Connection) With Nut For Female Coupling As Per Is-902 Complete With 150Mm Dia. Suction Pipe And Foot Valve (To Be Connected To Static Tank) Complete As Required And As Per Enclosed Specification . Approved Make: Newage / Safex / Shah Bhogilal/ Kartar , Supply, Installation Testing & Commissioning Of Two-Way Gun Metal Fire Brigade Inlet Connection Consisting Of 63Mm Size Instantaneously Male Coupling And Shall Be Protected By Cap Scored With A Chain Glass Bore Etc. Complete With One Butter Fly Valve And 1 Nos Non- Return Valve.( For External Ring Main, Tower Hydrant)Approved Make: Newage/ Safex/ Shah Bhogilal , Pipes & Valves , Providing, Fixing, Jointing And Commissioning Of Following Sizes Of C- Class Heavy Duty Mild Steel Pipes Conforming To Is-1239/Is-3589, Including Cutting Welding, Threading, Hut Bolts Gasket, Fitting, Viz Bends, Ceiling/ Beam/Floor With Suitable Ms Clamps / Structural Supports/ Pcc Block And Painting Complete As Required And As Per Enclosed Specification . Approved Make: Tata/ Jindal/Apollo Note:- The Pies Size 150Mm & Below Shall Be M.S.C Class As Per Is : 1239 And Pipes Size Above 150Mm Shall Be Welded Black Steel Pipe Heavy Class As Per Is:3589, From Minimum 6.35Mm Thick M.S. Sheet For Pipes Upto 350Mm Dia. And From Minimum 7Mm Thick Ms Sheet For Pipes Of 400Mm Dia And Above. , 150 Mm Dia. , 100 Mm Dia. , 80 Mm Dia. , 50 Mm Dia. , 25 Mm Dia. , Providing Fixing Testing And Commissioning Of Following Sizes Of Gate Valve Of Rating Pn 16, Wafer Type In Cast Iron Body With Ductile Lron Disc, Epdm Seal, Ss Single Piece Shaft Conforming To Is-13095 Of The Following Sizes Complete With Cast Iron Hand Lever Companion Flanges, Bolts Nuts Washers & Inserted Rubber Gaskets, As Required And As Per Enclosed Specification. Approved Make: Leasderloto.Oto/Sant , 150 Mm Dia. , 100 Mm Dia. , Providing, Fixing, Testing And Commissioning Of Following Size Of Ci Non Return Valve Conforming To Api-594 With C.I. Body, Ss Disc, Ss Stem, Epdm Seal, Completewith Companionflanges, Bolts, Nuts, Washers & Inserted Rubber Gasket Complete As Required And As Per Enclosed Specification. (Pn-16) Approved Make: Leader/Zoloto / Sant 100 Mm Dia. , Providing & Fixing Of 25Mm Dia. Gunmetal , Air Release Valve With All Fitting And Forged Ball Valve On Header Complete As Required And As Per Enclosed Specification. Approved Make: Leader/Zoloto / Sant , Providing And Fixing Following Size Pressure Gauge (0-15 Kg/Cm2) Complete With Shut Off Valve Duly Calibrated Before Installation Complete As Required & As Per Enclosed Specification. 150Mm Dia. Approved Make: H.Guru / Feibig , Providing, Fixing & Installation Of Control Valve (Sprinkler Alarm Valve) Of Cast Iron Body And Bronze Working Parts Comprising Of Water Motor Alarm, Bronze Seat Clapper And Clapper Arm, Hydraulically Driven Mechanical Gong Bell To Sound Continuous Alarm When The Wet Riser/Sprinkler System Activates, Pressure Gauges, Emergency Releases, Strainer, Pressure Switch, Cock Valve Complete With Drain Valve And Bypass, Test Control Box, Ball Valves, Flanges, Orifice Plate, Fittings, Gasket Etc. Suitable For 150 Mm Diameter Pipe Size Complete As Required As Per Enclosed Specification. Approved Make: Hd / Newage , Automatic Sprinkler System , Providing & Fixing Of 15 Mm Dia. Sprinkler Head With Standard Response Quartzite Bulb Operate At 68 Degree C Complete With All Accessories As Required And As Per Enclosed Specification (Ul Listed) Pendent Type In Chrome Finish (Standard Coverage) Approved Make: Hd / Tyco/Vking/Newage , Providing And Fixing Electrically Operated Flow Indicating Switches Vane Type With Threaded Connection For Indicating Water Flow In Sprinkler Branch Line With Necessary Junction Box In Stalled In Accessible Place. Including Cost Of Cable Etc. Complete. (Wiring From Switches To Panel And Stair-Case Pressurisation Not Included). , Approved Make: Honeywell/ Sensotronic System/ Switzer , Providing And Fixing 25Mm Dia Inspecting & Testing Assembly With S.S. Isolation Valve S.S. Sight Glass Byepass Valve & Connected To Line Drain Complete In All Respect As Per Standard Practice Of Code Including Pressure Gauges Of Approved Make. Approved Make: Reliable /Hd/Ul/Listed , Fire Extinguisher , Supply, Installation, Testing And Commissioning Isi Marked (Is:15683) Fire Extinguisher, Carbon-Di-Oxide Type Capacity 4.5 Kg. Flat Base Including Valve, Discharge Hose Of Not Less Than 10Mm Dia, 1M Long And Complete In All Respects Including Initial Fill With Co2 Gas Conforming To Is: 307-1966 And Wall Suspensionbraket As Required As Per Specifications. Approved Make: Minimax/ Safex/ Cease Fire/ Safeguard , Blood Bank (Co2 Trolly 9 Kg) , New Building (Co2 4.5 Kg) , Red Building (Co2 Trolly 9 Kg) , C.S Office (Co2 Trolly 9 Kg) , Other Urban Health Institution Of Ranchi , Supply, Installation, Testing And Commissioning Of 6Kg Abc (Powder/Dcp Type) Fire Extinguisher , Mid Steel Cylinders Isi Marked Fitted With Pressure Indicating Gauge, Internal Tube, Squeeze Lever Type Valve Fully Charged With Abc 90 Powder (Mono Ammonium Phosphate) Pressured By Nitrogen Complete In All Respects Including Wall Suspension Bracket And Conforming To Is : 15683 As Required As Per Specifications . Approved Make: Minimax/ Safex/ Cease Fire/ Safeguard/Safepro/ Kanex , Mechanical Foam Type Fire Extinguisher In Hp Mild Steel Cylinders Isi Marked / Approved Fitted With Pressure Indicating Gauge, Internal Tube, Squeeze Lever Type Valve Fully Charged Complete In All Respects Including Wall Suspension Bracket / Trolley , Mounted And Conforming To Is:910 50 Litres (Trolley Mounted) Approved Make: Minimax / Safex / Cease Fire / Safeguard , Fireterrace Pump Type:End Suction Speed (Rpm): 2900 Capacity: 900 Ipm Head : 35Mtr. , Providing Fixing, Testing And Commissioning Of Control Panel For Terrace Booster Pumps. Incoming: Mccb 35A 1 Set Of Phase Indicating Lamps, 1 Set Of 35Al Bus Bars, 1 No Ammeter, 1 No Voltmeter Withphase Selector Switch Feeder For Booster Pumps-1No. 1 No. 32A Tp Mccb Without Releases, Dol Starter With Over Load Relay , Single Phase Preventer And Indicating Lamps With On/Off Push Buttons. 1 No . Automanual Selector Switch ,Suitable For Booster Pumps Water Reservoir 1.00L , Fire Alarm And Detection Works , Conventional Type / Addressable Type Manual Alarm System , Supply Installation Testing And Commissioning Of 24V Manual Call Point Mcp Agni/Morley/Siemens , Supply Installation , Testing & Commissioning Of 24 V Hooter Agni/Morley/Siemens , Supply Installation , Testing & Commissioning Of 6/8 Zone Control Panel Agni/Morley/Siemens , Wire 2X1.5Mm Armoud Cable Fire Proof (Anchor/Poly Cap / Havlles) , Supply Installation , Testing & Commissioning Of Smoke + Heat Detector Ionised Type With Base Agni/Morley/Siemens , Supply Installation , Testing & Commissioning Of Response Indicator 24V Agni/Morley/Siemens , Civil Work , Supply Installation& Commissioning Of 5000 Letters Of Sintex Water Container (Four Layer) For Over Head Water Storage For Fire Hydrant& Fire Sprinkler System , Construction Of Rcc Over Head Water Tank With 20,000 L Water Capacity With Superior Quality Concrete, Steel & Materials , Fire Suppression System , Supply Installation& Commissioning Of Fire Suppression System Fk5112 Specially For Fire Panal Automatic Type Life Guard / Spectra/ Novac , Supply Refilling And Maintenance Of Fire Extinguisher Cylinder Of All Building Of Sadar Hospital Ranchi , Fire Safety Mock Drill Of 100 People Of Sadar Hospital Ranchi Given Quarterly , Maintenance Of Water Reservoirof 200000 L & Repairing If Needed , General Maintenance Of Fire Fighting Amc Including, Testing , Repairing & Refilling Of Cylinder Only
Basic Detail
Tender No 1448(DHS)
Bidding Type Tender
Location
City ranchi
State Jharkhand
Key Dates
Publish Date 25 Mar 2023
Submission Date 30 Mar 2023
Open Date 31 Mar 2023
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 2.50 Lakhs
Exemption Not Available
Document List
5476807d-92ed-4a8b-8e53-da479cd7a906.html
BOQ_91747.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 25, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 30, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 31, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

5476807d-92ed-4a8b-8e53-da479cd7a906.html

xls

BOQ_91747.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders