Directorate Of Municipal Administration-DMA has published Tender For Express Feeder Maintenance Transformer Capacitor,Ab Switch Supplying Erecting And Repairing At Talegaon Dabhade Municipal Council.. Submission Date for this Tender is 05-04-2023. Feeder Pillar Tenders in Pune Maharashtra. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supplying and erecting porcelain disc type insulator suitable for 22kV line, complete as per specification No.OH-INS/DI |
2 | Supplying and erecting porcelain pin type insulator suitable for 22kV line, complete as per specification No. OH-INS/PN |
3 | Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394.00 kg/km) as per specification No. OHCON/ACSR |
4 | Providing and erecting Heat shrinkable outdoor termination kit for 22 kV ( E ) XLPE HT cable3x240 to 400 sq mm. with necessary material as per specification No.CB-JT/HT |
5 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT |
6 | Providing and erecting Heat shrinkable straight through joint kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CBJT/HT |
7 | Providing and erecting of Tripping coil for ACB 800 Amp to 1200 Amp |
8 | Providing and erecting of Clossing coil for ACB 800 Amp to 1200 Amp |
9 | Supplying , erecting & terminating 3 x 300 sq mm 22 kV,XLPE(E) armoured cableon wall/ceiling or laid in provided trench / pipe in an approved manner as per specification No.CB-HT |
10 | Supplying , erecting& terminating 3 x 95 sq. mm. aluminium 22 kV(E), XLPE armoured cableon wall/ceiling or laid in provided trench / pipe in an approved manneras per specification no.CB-HT |
11 | Providing and erecting Heat shrinkable straight through joint kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CBJT/HT |
12 | Providing and erecting Heat shrinkable out door termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. cable with necessary material as per specification no. CB-JT/HT |
13 | Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT |
14 | Supplying and erecting half clamps for pole made from 50 x 10 mm flat for fixing cross arms by means of 15 mm dia. bolts and nuts painted with one coat of red oxide and two coats of aluminium paint. |
15 | Supplying and erecting approved make 22 kV out door type gang operated air break, triple pole switch 200A, capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. |
16 | 11kv/22kv/33kv Cable Fault Detection for HT power underground cable from 35 sq.mm to 400 sq.mm by acoustic Method by using surge wave tester & surge wave receiver (Duophone) up to 250mtr length cable with recording results & submission of Test reports (7-1-42) |
17 | Providing cement concrete for foundation or for concrete filling in 1:3:6 ratio with 20 to 25 mm. stone metal duly plastered with necessary curing for pole muffing or any other purposes. |
18 | Supplying and erecting Rolled steel Joist (Girder) pole 152 x 152 mm (37.1 kg/m) with provided base plate in provided foundation as per specification No. OH-PL/RSJ |
19 | Supplying & erecting single pole cut pointchannel set of for 11 kV HTOH line, two channel of size 100 x 50 mm 1.6 m long having stud angle of size 50 x 50 x 6 mm 1.5 m long with top piece of size 100 x 50 mm 0.45 m long with necessary clamps, nut bolts etc. complete as per drawing |
20 | Supplying and erecting Vee cross arm for 22/ 33kV HTOH line with arrangement to fix insulator at 45mmfrom the end & horizontal distance between insulators 1530 mm bent at angle of 60 degree keeping base 310 mmand the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts,washers complete as per specification No. OHPL/VCA |
21 | Supplying, erecting & terminatingXLPE armoured cable 3½ core25 sq. mm. aluminium conductor withcontinuous5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
22 | Supplying, erecting & terminatingXLPE armoured cable 3½ core35sq. mm. aluminium conductor with continuous5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
23 | Supplying, erecting & terminatingXLPE armoured cable 3½ core50 sq. mm. aluminium conductor withcontinuous5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
24 | Supplying, erecting & terminating XLPE armoured cable 3½ core70 sq. mm. aluminium conductor with continuous8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
25 | Supplying, erecting & terminating XLPE armoured cable 3½ core95sq. mm. aluminium conductor with continuous8.35 sq. mm. (10 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
26 | Supplying, erecting & terminating XLPE armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97sq. mm. (8 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
27 | Supplying, erecting & terminating XLPE armoured cable3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
28 | Supplying, erecting & terminatingXLPE armoured cable 1100 V. 3½ core185 sq. mm. aluminiumconductor withcontinuous 12.97 sq. mm. (8 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
29 | Supplying, erecting & terminatingXLPE armoured cable 3½core 240sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
30 | Supplying, erecting & terminatingXLPE armoured cable 3½ core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
31 | Supplying, erecting & terminating XPLE armoured cable 4 core16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
32 | Supplying, erecting & terminating XLPE armoured cable 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
33 | Providing & erecting epoxy straight through jointoutdoor/ indoorfor LT XLPE armouredcable 2.5 to 16 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
34 | Providing & erecting epoxy straight through jointoutdoor/ indoor for LT XLPE armoured cable 25 to 50 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
35 | Providing & erecting epoxy straight through joint outdoor/ indoor for LT XLPE armoured cable 70 to 95 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
36 | Providing & erecting epoxystraight through jointoutdoor/indoorfor LT XLPE armouredcable 120 to 185 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
37 | Providing & erecting epoxystraight through jointoutdoor/indoorfor LT XLPE armouredcable 240 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
38 | Providing & erecting epoxystraight through jointoutdoor/indoorfor LT XLPE armouredcable 300 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
39 | Providing & erecting epoxystraight through jointoutdoor/indoorfor LT XLPE armouredcable 400 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
40 | Providing & erecting epoxyoutdoor / indoor end termination kit for LT XLPE armouredcable 2.5 to 16 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
41 | Providing & erecting epoxyoutdoor / indoor end termination kit for LT XLPE armouredcable 25 to 50 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
42 | Providing & erecting epoxyoutdoor / indoor end termination kit for LT XLPE armouredcable 70 to 120 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
43 | Providing & erecting epoxyoutdoor / indoor end termination kit for LT XLPE armouredcable 150 to 185 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
44 | Providing & erecting epoxyoutdoor / indoor end termination kit for LT XLPE armouredcable 240 to 300 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
45 | Providing & erecting epoxyoutdoor / indoor end termination kit for LT XLPE armouredcable 400 sq. mm. cable, with necessary materialas per specification no. CB-JT/LT |
46 | Supplying & laying (including excavation) 15 cm diaRCCHumepipewith coupling collar of standard thickness at required depth up to 90 cm below road / groundsurface,forenclosing providedcable&necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet). |
47 | Supplying & laying (including excavation) 15 cm dia half round RCCHumepipe of standard thickness at required depth up to 90 cms. below road / groundsurface,forenclosing providedcable&necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet). |
48 | Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. |
49 | Supplying & erecting Siemens type brass cable glands for4 core 50 sq. mm.for XLPE armoured cableas per specification no. CBGL |
50 | Supplying & erecting Siemens type brass cable glands for 3½ core 70 sq. mm.for XLPE armoured cableas per specification no. CB-GL |
51 | Supplying & erecting Siemens type brass cable glands for 3½ core 95 sq. mm. for XLPE armoured cableas per specification no. CB-GL |
52 | Supplying & erecting Siemens type brass cable glands for 3½ core 120 sq. mm. for XLPE armoured cableas per specification no. CB-GL |
53 | Supplying & erecting Siemens type brass cable glands for 3½ core 150 sq. mm. for XLPE armoured cableas per specification no. CB-GL |
54 | 7-7-10 Supplying & erecting Siemens type brass cable glands for 3½ core 185 sq. mm. for XLPE armoured cableas per specification no. CB-GL |
55 | Supplying & erecting Siemens type brass cable glands for 3½ core 240 sq. mm. for XLPE armoured cableas per specification no. CB-GL |
56 | Supplying & erecting Siemens type brass cable glands for 3½ core 300 sq. mm.for XLPE armoured cableas per specification no. CB-GL |
57 | Supplying & erecting crimping type aluminium lugs for cable up to 16 sq. mm. completeas per specification no. CB-CL/AL |
58 | Supplying & erecting crimping type aluminium lugs for cable25 sq. mm. completeas per specification no. CB-CL/AL |
59 | Supplying & erecting crimping type aluminium lugs for cable35 sq. mm. completeas per specification no. CB-CL/AL |
60 | Supplying & erecting crimping type aluminium lugs for cable50 sq. mm. completeas per specification no. CB-CL/AL |
61 | Supplying & erecting crimping type aluminium lugs for cable70 sq. mm. completeas per specification no. CB-CL/AL |
62 | Supplying & erecting crimping type aluminium lugs for cable95 sq. mm. completeas per specification no. CB-CL/AL |
63 | Supplying & erecting crimping type aluminium lugs for cable120 sq. mm. completeas per specification no. CB-CL/AL |
64 | Supplying & erecting crimping type aluminium lugs for cable150 sq. mm. completeas per specification no. CB-CL/AL |
65 | Supplying & erecting crimping type aluminium lugs for cable185 sq. mm. completeasper specification no. CB-CL/AL |
66 | Supplying & erecting crimping type aluminium lugs for cable240 sq. mm. completeasper specification no. CB-CL/AL |
67 | Supplying & erecting crimping type aluminium lugs for cable300 sq. mm. completeas per specification no. CB-CL/AL |
68 | Dismantlingtheexistingcables of all types & size up to 10 sq. mm. |
69 | Dismantlingtheexistingcables of all types & size above 10 sq mm up to 50 sq. mm. |
70 | Dismantlingtheexistingcables of all types & size above 50sq. mm. |
71 | Refilling the holes for dismantled cables with cement mortar & finishing in an approved manner etc. complete. |
72 | Dismantling the existing underground cable withoutdamagingit with glands, cable end box including refilling the trench up to ground level and making coils complete. |
73 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP |
74 | Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EAEP |
75 | Supplying and erectingaluminium strip of required sizes used for earthing on wall and/or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EAEP. |
76 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessarycopperclampsfixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. |
77 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. |
78 | Supplying and erecting Annealed bare copper wireof high purity of different sizesused forearthing onwall with necessarycopperclampsfixedon wall/cable/conduitwithscrews in an approved manner. |
79 | Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner. |
80 | Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall with insulating and non-corrosive bond in an approved manner with required joints. As per specification no. EAEP. |
81 | Supplyinganderecting22 kV fuse barrel with metal fittings complete. |
82 | Supplyinganderectingextrathick alkathene pipe 10 mm dia. erected to enclosebareconductor wires complete.. (use shall be restricted to H.T.) |
83 | Supplyinganderecting hard drawn coppersolidwire no. 0to 6SWG complete erected for connections on H.T. sides. |
84 | Supplying operating rod, suitable for 11/22 kV supply withclampsfor removing drop out fuses at 6 meters length, 4 pieces each with rain shade withhandgrip including earthling chain 1.5 m complete.(Light duty) |
85 | Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). |
86 | Providing printed instruction chart for treating persons suffering from electric shock,printedinEnglish & Marathi and duly laminated complete. |
87 | Providingpair ofdulytestedrubber hand glovesas per IS :47705suitable forworking upto 22 kV supply complete. |
88 | Providing Round bottomfire bucket of 9 Litres capacityas per IS : 2546 madeoutof 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete. |
89 | Providing Floormountingstand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with crosssupports for legs, welded with 4 hooksanddulypaintedwith one coat of red lead and two coats of silver paint complete. |
90 | Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCBEach 605486535-3-15 Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB Each 87848926 |
91 | Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB |
92 | Supplying, erecting & marking DPMCB 40A to 63A, C- series (for motor/power) in provided distribution boardas per specification no. SW-SWR/MCB |
93 | Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB |
94 | Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB |
95 | Supplying, erecting & marking SPMCB 40A to 63A C- series (for motor/power) in provided distribution boardas per specification no. SW-SWR/MCB |
96 | Supplying, erecting & marking SPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB |
97 | Providing & erecting 3 Pole MCCB upto 100A, 415V,with short circuitrating 25 kA (Ics=100% of Icu ),adjustablethermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frameas per specification no. SW-SWR/MCCB |
98 | Providing & erecting 3 Pole MCCB of 200A,415V capacity with short circuit rating 25 kA (Ics=100% of Icu)adjustablethermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frameas per specification no. SW-SWR/MCCB |
99 | Providing & erecting 3 Pole MCCB of 250A,415V capacity with short circuit rating 36 kA (Ics=100% of Icu) adjustablethermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frameas per specification no. SW-SWR/MCCB |
100 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. |
101 | Supplying and erecting 525 V 3 phase, 50 Hz., MPP type capacitor having minimum overcurrent capacity of 1.8 In,peak inrush current capacity 300 Inand minimum life 150000 hourskVAr bank of metalised polypropylenecondensers (MPP) withthe standard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVArunits ofP.F. correctionforoperationon 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and providedwithterminalcoverbox completeerected onprovidediron bracketoronfloordulytestedby licensee. |
102 | Providing maintenance of ACB of all range with ACB maintenance kit by ACB manufacturer consisting of all the essential consumables like greases, cleaning spray, dusters, scrubbers and hardware required and carrying out necessary corrective maintenance of ACB complete.(excluding required spare prices) |
103 | Supplying and erecting ON LOAD four pole automatic transfer switch suitable for 415V, 200A, 50 Hz capacity with enclosure, automatic/manual inbuilt time delay, high transfer speed, excellent breaking capacity, superior making capacity, compact & light weight, erected on provided angle iron / GI frame and connected with provided leads complete. |
104 | Supplyinganderectingminifeeder pillar triple pole with 300A FPMCCB as incomer and3 outgoing circuits with HRC fuse base and cartridge of 100Aconsists ofaluminium bus bar500V300A complete erected in 14 gauge CRCA sheet box with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP |
105 | Supplying, erecting & marking SPN MCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB |
106 | Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SW-SWR/MCB |
107 | Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB |
108 | Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB |
109 | Supplying&erectingtriplepoleand neutral distribution board (TPNDB) surface/ flushmounted SP / TPMCB of36 ways on iron / GI frame (vertical busbar type) as per specification no. SWSWR/MCBDB |
110 | Providing & erecting 3 Pole MCCB of 200A,415V capacity with short circuit rating 25 kA (Ics=100% of Icu)adjustablethermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frameas per specification no. SW-SWR/MCCB |
111 | Providing & erecting 3 Pole MCCB upto 100A, 415V,with short circuitrating 25 kA (Ics=100% of Icu ) , adjustablethermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frameas per specification no. SW-SWR/MCCB |
112 | Supplyinganderectingair circuitbreaker manually operated nondrawout type of 800A rated at 50º C without deration, 500V, 3 pole with having short circuitrating 50 kA (Ics=Icu=Icw for 1s), standard accessories and thermal magnetic release on provided iron frame as per specification no. SW-SWR/ACB |
113 | Supplyinganderectingair circuitbreaker manually operated nondrawout type of 1000A rated at 50º C without deration, 500V, 3 pole having short circuitrating 50 kA (Ics=Icu=Icw for 1s), with standard accessories and thermal magnetic release on provided iron frameasper specification no. SW-SWR/ACB |
114 | Supplyinganderectingair circuitbreaker manually operated nondrawout type of 1600A rated at 50º C without deration, 500V, 3 pole having short circuitrating 50 kA (Ics=Icu=Icw for 1s), with standard accessories and thermal magnetic release on provided iron frameas per specification no. SW-SWR/ACB |
115 | Supplyinganderectingair circuitbreaker manually operated drawout type of 800A rated at 50º C without deration, 500V, 3 pole having short circuitrating 50 kA (Ics=Icu=Icw for 1s), with standard accessories and thermal magnetic release on provided iron frameas per specification no. SW-SWR/ACB |
116 | Supplyinganderectingair circuitbreaker manually operated drawout type of 1000A rated at 50º C without deration, 500V, 3 pole having short circuitrating 50 kA (Ics=Icu=Icw for 1s), with standard accessories and thermal magnetic release on provided iron frameas per specification no.SW-SWR/ACB |
117 | Supplyinganderectingair circuitbreaker manually operated drawout type of 1250A rated at 50º C without deration, 500V, 3 pole having short circuitrating 50 kA (Ics=Icu=Icw for 1s), with standard accessories and thermal magnetic release on provided iron frameas per specification no.. SW-SWR/ACB |
118 | Supplying & erecting HRC fuse cartridge 415V 100A complete |
119 | Supplying & erecting 415V 32A porcelain base neutral link complete erected in provided MS box complete |
120 | Supplying & erecting porcelain/epoxy bus bar support complete erected in provided MS box for 200/300A complete |
121 | Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 3 pole upto 250A MCCB complete.(set of 6) |
122 | Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 3 pole630A MCCB complete. (set of 6 |
123 | Supplying and erecting earth fault module for MCCB with adjustable earth fault sensitivity selection 10% to 50% of nominal current (In) and adjustable time delay 100/200 millisecond suitable for above 200A upto 400A MCCB with inbuilt CT"s complete. |
124 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for upto 250A MCCB complete. |
125 | Supplying and erectingextended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A upto 630A MCCB complete |
126 | Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A complete as per specification no. CP-BB |
127 | Supplying and erecting bus bar chamber triple pole with neutral with four copper bars, 500V, 100A complete as per specification no. CPBB |
128 | Supplyinganderecting panelmounting type digital ammeter havingthree andhalfdigit LEDdisplay, externalCToperated,calibratedfor suitable to operate on 500V, 0 to 1000AAC supply with necessary PVC wire leads and lugs andmounting hardware on provided panel complete with calibration certificate from manufacturer. |
129 | Supplying and erecting panelmountingtypedigital voltmeter having threeandhalfdigit LED display, calibrated for 0 to 750V AC suitable to operate on 500V AC supplywithnecessaryPVCwireleadsandlugsand mountinghardwareonprovidedpanelcompletewith calibration certificate from manufacturer |
130 | Supplyinganderecting Three phase smart energy meter DLMS compliance with 3x240V 50 cycles AC supply 10-60 A, ISI mark, accuracy class 1.0 with backlit LCD display, measuring & display V, I, kW, kWh, PF, kVA,kVAr, MD,day, week, month &with communication module configurable for GSM/Wi-Fi, IrDA/Bluetooth, complete provided panel with calibration certificate from manufacturer & duly wiredwithrequired size of PVC wires |
131 | Supplying,erecting,testing,commissioning 22KVHT metering cubical (compact type) approved by MSEDCL/licenseefabricated with 2mm.(14 SWG) M.S. sheets with supporting angle and channel, painted with powder coating / epoxy paintof required shade copper bus bar size 25x6 mm electronic security lock and heavy duty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover ( CT,PT cover)interlock with meter doors, epoxy coated 3 nos CT having required ratio between 50/5 A to 100/5 A, VA10, class 0.2S, 22000/V3/110/V3 VA 50, class 0.2 epoxyterminalblocksuitablefor providedtrivectormeter,andprovisionforincomingand outgoing cables etc. complete duly tested bylicenseewith necessary test certificates and erected on provided plinth/ cc foundation |
132 | Supplying and erecting 525 V 3 phase, 50 Hz., MPP type capacitor having minimum overcurrent capacity of 1.8 In,peak inrush current capacity 300 Inand minimum life 150000 hourskVArbank of all polypropylene condensers (APP)withthestandard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVArunitsofP.F. correctionforoperationon 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and providedwithterminalcoverbox completeerected onprovidediron bracketoronfloordulytestedby licensee. |
133 | Inspection of Faulty Feeder and Fault finding and submitting test report with minor repairing work if any for each fault under supervision of municipal council engineer |
134 | Inspection of faulty distribution transformer 11kV/22kV on HV side, 415 V on LV side upto 500 kVA capacity in workshop in presence of authority by opening top cover, disconnecting HV & LVstuds, tap changer connections; taking out core along with windingfor inspection and carrying out necessary tests on HV, LV side, oil,tap-changer etc. checking breather, body condition etc. and submitting inspection report, test reports (oil, insulation, resistance, ratio,etc.) and quotation for repairs complete. |
135 | Supplying and topping up filtered transformer oil of approved make with test certificate. |
136 | Spray painting of distribution transformer upto 200 kVA capacity complete. Specification no. CW-PTG/PDT. |
137 | Spray painting of distribution transformer above 200 kVA capacity complete. Specification no. CW-PTG/PDT. |
138 | Filtration of Transformer oil on site till satisfactory test results. |
139 | Providing and maintaining distribution transformer 11kV / 22 kV on HV side 415 V on LV side up to 63 to 200 kVA Capacity for ten days on hired basis. |
140 | Providing and maintaining distribution transformer 11kV/22 kV on HV side 415 V on LV side up to 250 to 500 kVA Capacity for ten days on hired basis. |
141 | Providing and maintaining distribution transformer 11/22 kV on HV side 415Von LV side upto 500 kVA capacity on hired basis subsequent to first ten days after commissioning. |
142 | Erecting 11kv/22 kV on HV side 415 V on LV side up to 500 kVA capacity hired/provided transformer on existing plinth /DP structure, making connections on HV & LV side in approved manner, carrying out necessary tests before and after charging upto full load to satisfaction. |
143 | Inspection of faulty distribution transformer 11kV/22kV on HV side, 415 V on LV side upto 500 kVA capacity in workshop in presence of authority by opening top cover, disconnecting HV & LVstuds, tap changer connections; taking out core along with winding for inspection and carrying out necessary tests on HV, LV side, oil, tap-changer etc. checking breather, body condition etc. and submitting inspection report, test reports (oil, insulation, resistance,ratio,etc.) and quotation for repairs complete. |
144 | Supplying, installing, testing & commissioning single phase, 11 kV/V3/250V, 15 kVA, oil cooled with CSP features outdoor type,aluminium wound transformer, temperature rise should not exceed 40oC by thermometer in oil and 45oC b the resistance in winding at full load rating,with 5% continuously rated for full load with standard accessories complete with test certificate with losses should be below 82 Watts at 50% load & 224 Watts at 100 % load & first filling of oil having vector group- DYN-11 & first filling of silica gel,as per IS:1180 - 2014 energy efficieny level II with necessary permissions of Electrical Inspector, |
145 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete |
146 | Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide |
147 | Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD |
148 | Dismantling the existing distribution transformer of any capacity from the plinth / foundation safely without any damages. |
149 | Dismantling existing pole mounted distribution transformer safely without any damages. |
150 | Dismantling existing DO / AB switch set complete from D.P. structure in an approved manner. |
151 | Supplying and erecting approved make 22 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessaryclamp. |
152 | Supplying and erecting approved make 33 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator double stack per phase, mounted in horizontal position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. |
153 | Supplying and erecting 22 kV fuse barrel with metal fittings complete. A |
154 | Supplying and erecting hard drawn copper solid wire no. 0 to 6 SWG complete erected for connections on H.T. sides. A |
155 | Supplying and erecting extra thick alkathene pipe 10 mm dia. erected to enclose bare conductor wires complete.. (use shall be restricted to H.T.) |
156 | Supplying operating rod, suitable for 11/22 kV supply with clamps for removing drop out fuses at 6 meters length, 4 pieces each with rain shade with hand grip including earthling chain 1.5 m complete.(Light duty) As per electrical D.S.R. No 2017-18/10-2-12 |
157 | Supplying Heavy duty operating rod, Outer Dia 25 mm & inner dia 20 mm suitable for 22/33 kVwith brass couplings etc for removing drop out fuses at 6 m length, 4 pieces each with rain shade with hand grip including earthing chain 1.5 m |
158 | Supplying and erecting clamps, made out of 25x3 mm, copper strips to be fixed to tubular bus for connecting the bare copper wire to other equipment, with brass nuts bolts of suitable dia complete. |
159 | Supplying and erecting ant climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. |
160 | Supplying & erecting Siemens type brass cable glands for 3½ core 70 sq. mm. for XLPE armoured cable as per specification no. CB-GL |
161 | Supplying & erecting Siemens type brass cable glands for 3½ core 120 sq. mm. for XLPE armoured cable as per specification no. CB-GL |
162 | Supplying & erecting Siemens type brass cable glands for 3½ core 240 sq. mm. for XLPE armoured cable as per specification no. CB-GL |
163 | Supplying & erecting Siemens type brass cable glands for 3½ core 300 sq. mm. for XLPE armoured cable as per specification no. CB-GL As |
164 | Supplying & erecting crimping type aluminium lugs for cable 70 sq. mm. complete as per specification no. CB-CL/AL |
165 | Supplying & erecting crimping type aluminium lugs for cable 120 sq. mm. complete as per specification no. CB-CL/AL |
166 | Supplying & erecting crimping type aluminium lugs for cable 240 sq. mm. complete as per specification no. CB-CL/AL |
167 | Supplying & erecting crimping type aluminium lugs for cable 300 sq. mm. complete as per specification no.CB-CL/AL A |
168 | Supplying and erecting set of 3 pilot lamps all bakelite with colour glasses with miniature lamps 230 V/250V erected on provided CRCA box with panel type fuses and connected with PVC wires. |
169 | Supplying and erecting 525V 3 phase, 50 Hz.,MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of all polypropylene condensers (APP) with the standard capacities of 2,3, 5, 7, 10, 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.As per electric |
170 | Supplying and erecting copper tubular bus 20 mm dia 1.6 mm (16 SWG) thick for the use of high tension over head bus and erected on provided HT insulators with clamps, nuts and bolts complete. (weight per meter of bus is about 1.7 kg.) |
171 | Spray painting of distribution transformer upto 200 kVA capacity complete. |
172 | Spray painting of distribution transformer above 200 kVA capacity complete. |
173 | Disconnection of defective transformer form line by skilled electrician |
174 | Dismantling & removing of 400KVA transformer from plinth |
175 | Dismantling & removing of 500KVA transformer from plinth |
176 | Lifting of defective transformer & loading in truck by crane site & modifying at factory |
177 | Replacing of HV coil |
178 | Reinsulation of LV coil |
179 | Breather |
180 | Transformer connection & transformer testing with transformer report |
181 | Transformer bushing with connection 22KV HV.site. |
182 | Transformer lamination (CRg.o.) |
183 | Transformer bushing with connection LV site |
184 | Transformer painting & fabrication |
185 | Lifting & loding of repaired transformer of upto 500 kVA in truck by crane at factory & lifting & unloading at site. |
186 | Connection & reconnection of transformer at site by skilled electrician. With checking |
187 | Assembling reerectivity,testing & heating of upto 200KVA transformer at site |
188 | Assembling reerectivity,testing & heating of 400KVA transformer at site |
189 | Assembling reerectivity,testing & heating of 500KVA transformer at site |
190 | Transportation of above transformer at site to factory & after reparing factory & after reparing factory to site |
191 | Less Old copper |
192 | Monthly/Quarterly visit &all checkup of transformer IR, ER, BDV and acidity Report of upto 500 KVA Transformer |
193 | Removing of hires transformer |
194 | Erection of hires transformer |
195 | Removing Dismantling of defective Transformer |
196 | Replacing of HV coil 225 Kg |
197 | Reinsulation of LV coil 120KG |
198 | Transformer bushing with connection 22KV HV.site. |
199 | Transformer lamination (CRg.o.) |
200 | Transformer bushing with connection LV site |
201 | Makingtransformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete |
202 | Fencing for Transformer Station |
203 | Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete |
204 | Painting fencing of transformer substation including all supports, iron work and doors from both sides by scrapping existing paint, with one coat of red oxide & two coats of aluminium paint complete |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy